42PHW / 42PHQ 42PHQ...K

Similar documents
38GL...G / 38GLS...G 38YY...G / 38YYS...G

51AKS I S O OWNER S MANUAL

51AKB / 51 AKC OWNER S MANUAL

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

40KMC KMQ

Air Conditioner. user installation & manual manual. imagine the possibilities

53 KNL / 53 QNL OWNER S MANUAL

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

42JW 42JW INSTALLATION MANUAL

OWNER S AND INSTALLATION MANUAL RAV-480FS2B/RAV-480AS2B RAV-600FS8B/RAV-600AS8B

INSTALLATION INSTRUCTIONS

Installation Instructions

High Wall Split Air Conditioners 53QHCT KHCT

Installation Instructions

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

Air Conditioner. installation manual. imagine the possibilities

38VYX110/38VYX130 I S O INSTALLATION MANUAL

AIR CONDITIONER CONSOLE

Split Air Conditioner. Model: WMI09MH16S WMI12MH16S WMI18MH16S

SPLIT WALL-MOUNTED AIR CONDITIONER

INSTALLATION MANUAL Duct Type Series MH FECA

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

Installation manual for room air conditioner

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Installation Instructions

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1

Installer manual AG-WL10

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

Installation Instructions

Installation Instructions

ROOM AIR CONDITIONER INSTALLATION MANUAL

INVERTER SPLIT - TYPE

Installation Instructions

FDT11 FDT15 FDT18. DUCTED TYPE SPLIT SYSTEMS (3 Phase, Fixed Speed)

QUICK CONNECT INSTALLATION MANUAL DUCTLESS MINI-SPLIT SYSTEM FOR MODELS: 2PAMSHQC12 2PAMSHQC18 2PAMSHQC24 2PAMSHQC36

CENTRAL AIR CONDITIONER SPLIT SYSTEM

INSTALLATION MANUAL. System Air Conditioner (Cooling and Heating) Cassette Type Series CH070CAV1 CH105CAV CH140CAV DB A(1) ENGLISH ESPAÑOL

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

DUCTLESS MINI-SPLIT INSTALLATION MANUAL COMFORT...BUILT TO LAST

HEAT PUMP INSTALLATION MANUAL

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

Split-type Air-Conditioner

Split-type Air-Conditioner

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

Portable Air Conditioner USER MANUAL

1. BEFORE INSTALLATION

Installation Manual SPLIT-TYPE ROOM AIR CONDITIONER

SPLIT TYPE ROOM AIR CONDITIONER INSTALLATION MANUAL (PART NO )

Installation Instructions

Installation and Operation Manual. SVH Series. Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1

0RGHOV,QGRRU 8QLW MWM36Y3J 2XWGRRU 8QLW MRM36Y3J 11

MULTI TYPE ROOM AIR CONDITIONERS INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL. AIR CONDITIONER Wall Mounted Type. PART No Contents 1. SAFETY PRECAUTIONS 2. ABOUT THIS PRODUCT.

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

1. BEFORE INSTALLATION

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

INSTALLATION MANUAL. R22 Split Series. Models FTY25GXV1 FTY35GXV1. Installation manual R22 Split series

Local air conditioner

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

1. BEFORE INSTALLATION

Choosing the installation site. Installation. 07 Choosing the installation site

Installation Instructions

MULTI HEAT PUMP PANEL CONSOLE TYPE DUCTLESS INVERTER INDOOR UNIT INSTALLATION MANUAL. Models: CH09MCU230VI CH12MCU230VI CH18MCU230VI

15,000 BTU Portable Air Conditioner

Installation Instructions

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

DVC/DVH Series. Inverter Single Zone Ductless Mini-Split A-DVC/DVH 09SF A-DVC/DVH 12SF A-DVC/DVH 18SF A-DVC/DVH 24SF

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

Split-type Air-Conditioner

Installation Instructions

51AKB OWNER S MANUAL

Safety Precautions (1)

Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual

Installation Instructions

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

Safety Precautions WARNING INSTALLING THE UNIT POWER SUPPLY LINE, FUSE OR CIRCUIT BREAKER

AIR CONDITIONER FLOOR CEILING

Installation Manual Forest Series All Model Numbers

Indoor Unit Operation & Installation Manual

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

[FLARE CONNECTION TYPE] ATTENTION

Installation Manual. SYSPLIT WALL FLEXI Series SPLIT-TYPE ROOM AIR CONDITIONER

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4") ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig.

INSTALLATION INSTRUCTIONS

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

MODELS DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL FTXN50KV1B FTXN60KV1B. R410A Split Series

Installation Manual. KSIF Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

BEFORE USING THE APPLIANCE SAFETY PRECAUTIONS AIR CONDITIONER PRECAUTIONS

Installation Instructions

Split Air Conditioner

Installation Manual. WAS / WYS Series. For 9,000-36,000 BTU/hr Systems. Inverter+ and Inverter++ Models

Mini-Split Air Conditioner

Transcription:

42PHW / 42PHQ 42PHQ...K INSTALLATION MANUAL

Split system Hi-Wall indoor unit For operation and maintenance instructions of this unit, as well as installation instructions of the outdoor unit, refer to the relevant manuals. Contents Page Dimensions and weight... 2 Nominal data... 2 Operating limits... 2 Minimum clearances... 3 Material supplied... 3 General information... 4 Warnings: avoid... 5 ENGLISH Installation... 6/7 Refrigerant connections... 8 Check... 9 Electrical connection... 10/11 Operating test... 12 Address switch... 12 Guide for the owner... 12 Accessories... 12 AC models HP models HP models Power supply (R410A) (R410A) (R22) 42PHW007 42PHQ007 42PHQ007K 42PHW009 42PHQ009 42PHQ009K 42PHW012 42PHQ012 42PHQ012K 42PHW014 42PHQ014 42PHQ014K 42PHW018 42PHQ018 42PHQ018K 42PHW024 42PHQ024 42PHQ024K 230V ~ 50Hz AC Cooling only HP Heat pump GB - 1

Dimensions and weight A C B Mod. 42PHW/42PHQ007 42PHW/42PHQ009-012 - 014 42PHW/42PHQ 018-024 42PHQ007K 42PHQ009K - 012K - 014K 42PHQ018K - 024K A mm 790 790 1080 B mm 260 260 295 C mm 186 186 185 kg 8 8.6 14 ELECTRIC POWER INPUT Cooling only unit Cooling W Heating W Table I: Nominal data Unit is not suitable for operation in laundry premises. For sizing of power supply wires and delay type fuses, refer to the outdoor unit installation instructions. 42PHW007 32-42PHW009 43-42PHW012 43-42PHW014 43-42PHW018 53-42PHW024 53 - Heat pump 42PHQ007 / 42PHQ007K 32 32 42PHQ009 / 42PHQ009K 43 43 42PHQ012 / 42PHQ012K 43 43 42PHQ014 / 42PHQ014K 43 43 42PHQ018 / 42PHQ018K 53 53 42PHQ024 / 42PHQ024K 53 53 Table II: Operating limits Cooling/Heating Mains power supply Refer to outdoor unit installation manual. Nominal single-phase voltage Operating voltage limits 230V ~ 50Hz min. 198V max. 264V GB - 2

Minimum clearances (mm) ENGLISH 90 min. 200 min. 100 min. 1900 min. Obstacle Table lil: Material supplied The following installation accessories are supplied with unit. Use them as required. NAME and shape Q.ty Use Wall hanging bracket 1 For indoor unit installation. Screws 4xL10 2 For fixing unit and hanging bracket Screws anchors and screws 6xL25 Washers Ø 12 4 + 4 + 4 For wall hanging bracket installation. Screws anchors and screws 6xL20 2 + 2 For cordless remote control mounting bracket installation Cordless remote control mounting bracket 1 For cordless remote control installation. The following field-supplied items are required to complete the installation. Name Specification 42PHW007, 009 / 42PHQ007,007K, 009, 009K: Ø (3/8 ) 9.52 mm (Gas) / Ø (1/4 ) 6.35 mm (Liquid) 42PHW012, 014, 018, 024 / 42PHQ012, 012K, 014, 014K, 018, 018K, 024: Connection pipe Ø (1/2 ) 12.70 mm (Gas) / Ø (1/4 ) 6.35 mm (Liquid) 42PHQ024K: Ø (5/8 ) 15.87 mm (Gas) / Ø (1/4 ) 6.35 mm (Liquid) Wall sleeve Wall cap Finishing tape PVC film Fastening tape Pipe insulation Drain hose I.D. 16-17 mm Sealer putty - Power supply cable H07RN-F or higher - Electrical connecting cable Cable type: A07 RN-F, synthetic rubber insulation with Neoprene coating, between indoor and outdoor unit according to EN (IEC) 60335-2-40 and HD277.S1 standards. GB - 3

General information Unit installation Read this instruction manual thoroughly before starting the installation. This unit complies with low-voltage (EEC/73/23) and electromagnetic compatibility (EEC/89/336) directives. The installation must be carried out by a qualified installer. Follow all current national safety code requirements. In particular ensure that a properly sized and connected ground wire is in place. Check that voltage and frequency of the mains power supply are those required for the unit to be installed; the available power must be adequate to operate any other possible appliances connected to the same line. Also ensure that national safety code requirements have been followed for the mains supply circuit. The mains supply must be connected as follows: sizes 007-009 - 012-014: to the indoor unit; sizes 018-024: to the outdoor unit. Connect indoor and outdoor units with field-supplied copper pipes by means of flare connections. Use insulated seamless refrigeration grade pipe only, (Cu DHP type according to ISO1337), degreased and deoxidized, suitable for operating pressures of at least 4200 kpa and for burst pressure of at least 20700 kpa. Under no circumstances must sanitary type copper pipe be used. Where necessary, use field-supplied 16-17 mm I.D. PVC pipe of appropriate length and with the correct thermal insulation for the condensate drain extension. After the installation thoroughly test system operation and explain all system functions to the owner. Leave this manual with the owner for consultation during future periodic maintenance. Use this unit only for factory approved applications: the unit cannot be used in laundry or steam pressing premises. IMPORTANT: During the unit installation make first refrigerant connections and then electrical connections. If unit is uninstalled first disconnect electrical cables, then refrigerant connections. WARNING: Disconnect the mains power supply switch before servicing the system or handling any internal parts of the unit. Do not open the remote control to avoid possible damage. In case of malfunctioning contact a qualified service engineer. Control batteries contain polluting elements. When exhausted they must be disposed of according to local requirements. This installation manual describes the installation procedures of the indoor unit of a residential split system consisting of two units manufactured by Carrier. Consult the factory or a qualified system engineer prior to connecting this unit to any other manufacturer's outdoor unit. Coupling units which have different control systems, may cause irreversible damage and void the warranty protection. The manufacturer declines any liability for system malfunction resulting from unapproved coupling. The manufacturer declines any liability for damage resulting from modifications or errors in the electrical or refrigerant connections. Failure to observe the installation instructions or use of the unit under conditions other than those indicated in Table II (operating limits), will immediately void the unit warranty. Failure to observe electric safety codes may cause a fire hazard in case of short circuits. Inspect equipment for damage due to improper transportation or handling: file an immediate claim with the shipping company. Do not install or use damaged units. In case of any malfunctioning turn the unit off, disconnect the mains power supply and contact a qualified service engineer. Maintenance of the refrigerant circuit must only be carried out by qualified personnel. All of the manufacturing and packaging materials used for your new appliance are compatible with the environment and can be recycled. Dispose of the packaging material in accordance with local requirements. This equipment contains refrigerant that must be disposed of in the proper manner. When disposing of the unit after its operational life, remove it carefully. The unit must then be delivered to an appropriate disposal centre or to the original equipment dealer for proper environmentally compatible disposal. Choosing the installation site Positions to avoid: Exposed to direct sun. Too close to heat sources. On humid walls or positions with water hazard, e.g. laundry premises. Where curtains or furniture may obstruct free air circulation. Recommendations: Choose an area free from obstructions which may cause irregular air distribution and/or return. Check that the wall surface is flat enough to allow easy and safe installation. The wall structure should be strong enough to carry the unit weight and avoid deformation, rupture or vibration during operation. Consider using an area where installation is easy. Choose a position that allows for the clearances required (see drawing). Look for a position in the room which assures the best possible air distribution. Install unit in a position where condensate can easily be piped to an appropriate drain. GB - 4

Warnings: avoid ENGLISH Any obstruction of the unit air outlet or return. Exposure to direct sunshine, when unit is operating in cooling mode; always use shutters or shades. Positions too close to heating sources which may damage the unit. Exposure to oil vapours. Connecting condensate piping to sewage system drain without appropriate trap. Trap height must be calculated according to the unit discharge head in order to allow sufficient and continuous water evacuation. Installation in areas with high-frequency waves. Only partial insulation of the piping. Installation not correctly leveled which will cause condensate dripping. Any rise in the condensate drain piping. Horizontal condensate drain piping with less than 2% slope. Flattening or kinking the refrigerant pipes or condensate pipes. Excessive height difference between outdoor and indoor units (see installation manual of outdoor unit). Slack on electrical connections. Disconnecting refrigerant connections after installation: this will cause refrigerant leaks. Unnecessary turns and bends in interconnecting tubing. Excessive interconnecting tube length (see installation manual of outdoor unit). GB - 5

Installation The piping can be connected in the four ways indicated by,, and. When the piping is connected to points, or, remove the knock-out either at the side or at the bottom of the unit. Marking the wall penetration for the connection piping Rear piping It is best for the piping to go through the wall behind the unit, so that the unit hides the pipes. For this method of installation, make a 65 mm diameter hole in the wall at point A. 450 110 23 180 40 260 51 56 IMPORTANT NOTE: This unit has no refrigerant expansion device. Installing the wall hanging bracket Install the wall hanging bracket so that it is level. Use a plumb line if necessary. Be sure to leave the clearance spaces. (Refer to page 3). If the wall hanging bracket is not level, water may drip onto the floor. Install the wall hanging bracket with a fixing that is strong enough to withstand the weight of the unit. 120 min. 25 53 245 110 42PHW007-009 - 012-014 42PHQ007-007K - 009-009K - 012-012K - 014-014K 899 90 71 379 71 196 300 min. 450 min. 350 155 53 A Plumb line 42PHW018-024 42PHQ018-018K - 024-024K Drill a 65 mm diameter hole at a slope so that the outside end is lower (5-10 mm) than the inside end. This will ensure good drainage. Cut the wall sleeve to match the wall thickness and pass the pipe through the hole. Remove screw Before installing the wall hanging bracket, remove it from the unit by pushing at the indicated parts at the bottom of the body. Fasten the wall hanging bracket to the wall with 4 or more screw anchors through the holes near the outer edge of the bracket. Install the wall hanging bracket so that there is no gap between the bracket and the wall. Check that the wall hanging bracket does not move. This can cause noise during operation. If the unit is removed from the wall hanging bracket after installing it onto the wall, remove it by pushing up the indicated MARKS ( ) at the bottom of the body. (Refer to page 7). Side or bottom piping Remove the knock-out in the unit and pass the pipes through the wall. The pipe should slope downward and away from the unit to ensure good drainage. Indoor side Outdoor side 5 ~ 10 mm lower GB - 6

Installation Routing the drain hose and refrigerant piping Tie together the refrigerant pipe, the drain hose, and the electrical connection cord. Route the refrigerant piping in the required direction, and bind the drain hose and the electrical connection cord together with fastening tape. The drain hose should be at the bottom. ENGLISH Wall hanging bracket Hook Hole Indoor unit piping Left-hand piping Bind with fastening tape Drain hose For left-hand piping, fit the pipes and the wiring into the recess at the back of the unit. Indoor unit piping Drain hose Connection cord 42PHW007-009 42PHQ007-007K - 009-009K 42PHW012-014 42PHQ012-012K - 014-014K 42PHW018-024 42PHQ018-018K - 024-024K [mm] A B 300 220 300 220 270 195 NOTE: Do not crush or kink the indoor piping. Avoid sharp bends with a bend radius of less than 100 mm. Do not bend the same part of the pipe too often. Do not remove the flare nut from the indoor unit pipe until the piping is connected. The recommended bending of the drain hose is shown. Installing the indoor unit body to the wall hanging bracket Pass the pipes through the wall sleeve and then hook the indoor unit body on top of the wall hanging bracket. For left-hand piping, hang the unit on top of the wall hanging bracket and incline the unit using a tool such as a screwdriver set between the middle area of the body and bottom right of the wall hanging bracket. Connecting the pipe can be done more easily if the unit is inclined. Fix the bottom part of the unit to the wall hanging bracket, by pushing it carefully unit the two bracket hooks fit into the marked places at the base of the unit (a click will be heard). GB - 7

Refrigerant connections Refer to the outdoor unit installation manual for tube sizing, and limitations (slope, length, number of bends allowed, refrigerant charge, etc.). Model For refrigerant tubes use seamless, insulated refrigeration grade tube, (Cu DHP type according to ISO1337), degreased and deoxidized, suitable for operating pressures of at least 4200 kpa and for burst pressure of at least 20700 kpa. Under no circumstances must sanitary type copper pipe be used. Flaring the end of the tubing Tubing diameter Gas Liquid (Suction) (Discharge) mm (inches) mm (inches) 42PHW007-009 42PHQ007-007K 9.52 (3/8") 6.35 (1/4") 42PHQ009-009K 42PHW012-014 42PHW018-024 42PHQ012-012K 12.70 (1/2") 6.35 (1/4") 42PHQ014-014K 42PHQ018-018K-024 42PHQ024K 15.87 (5/8") 6.35 (1/4") Lubricate the tube end and thread of the flare fitting with antifreeze oil. Finger-tighten the fitting several turns, then tighten it fully with two wrenches by applying the tightening torque indicated in the table. Connection to the unit Insufficient tightening torque will cause gas leaks. Overtightening the fittings will damage the tube flaring and cause gas leaks. 1 3 Adjustable wrench or torque wrench Outdoor end Indoor end 2 Remove protective caps from the copper tube ends. Position tube end downward, cut the tube to the required length and remove the burrs with a reamer. Tubing diameter Torque mm (inches) Nm 6.35 (1/4") 18 9.52 (3/8") 42 12.70 (1/2") 55 15.87 (5/8") 65 Remove flare nuts from the unit connections and place them on the tube end. Flare the tube with the flaring tool. 4 5 L L Tube Tube insulation Fastening tape 6 Flare end must not have any burrs or imperfections. The length of the flared walls must be uniform. Once all connections have been completed, check for leaks by applying soapy water to them. Finally wrap connections with anti-condensate insulation and tighten with tape, without exerting great pressure on the insulation. Repair and cover any possible cracks in the insulation. Connection pipes and electric cables between indoor and outdoor units must be fixed to the wall with appropriate conduits. GB - 8

Check ENGLISH 300 mm min. Next, check the unit drain system by pouring some water into the unit drain pan and ensuring that it flows freely through the drain hose and that there is no leakage from any other part. Remote control bracket Use of additional screws After installation, if there is a significant gap between the unit and wall, it can be adjusted by securing the body to the wall hanging bracket using 2 screws. Screw holes can be only seen after removing the frame grille. Installing the remote control bracket Fix the bracket onto the wall using double sided adhesive tape or 2 screws. Install the batteries in the remote control and position it in the bracket. Grille Front panel GB - 9

Electrical connection IMPORTANT: Make refrigerant connections before electrical connections. When disconnecting, disconnect electrical connections before refrigerant connections. For sizes 007-009 - 012-014 make ground connection prior to any other electrical connections. The mains supply must be connected as follows: sizes 007-009 - 012-014: to the indoor unit; sizes 018-024: to the outdoor init. Make electrical connections between units prior to proceeding to mains supply unit connection. Before proceeding with the connection to the mains supply locate live L and neutral N, then make connections as shown in the wiring diagram. Ensure that mains supply connection is made through a switch that disconnects all poles, with contact gap of a least 3 mm. The indoor - outdoor unit connecting wires must be A07 RN-F type (or higher), with synthetic rubber insulation with Neoprene coating, according to EN 60335-2-40 and HD277.S1 codes. The mains supply connecting cable must be H07 RN-F type (or higher), with synthetic rubber insulation with neoprene coating, according to EN 60335-2-40 and HD277.S1 codes. Ground connection between indoor and outdoor units is made via the refrigerant pipes. Notes: All field electrical connections are the responsibility of the installer. Indoor unit wiring Lift the front panel up to the top of the unit; in this way the front panel will be separated from the unit. Remove the plastic cover of the terminal board. Make the electrical connections to the terminal board as per the wiring diagram. When the electrical connections are completed, refit the terminal board cover and fix the cables with the special cable holders. Fix the front panel to the latch of the frame grille. Cooling only (42PHW 007, 009, 012, 014) 230V ~ 50Hz L N N Y N Y Cooling only (42PHW 018, 024) R C Y 230V ~ 50Hz L N R C Y GB - 10

Electrical connection ENGLISH Heat pump (42PHQ007,007K, 009, 009K) Heat pump (42PHQ012, 012K, 014, 014K) 1 2 L N N Y O W2 1 2 230V ~ 50Hz N Y O W2 Heat pump (42PHQ 018, 018K, 024, 024K) R C Y O W2 S 230V ~ 50Hz 2 2 L N R C Y O W2 S Minimum connection wire size (mm 2 ) Model L N N Y O W2 42PHW007, 009 2.5 2.5 1.5 1.5 42PHW012, 014 2.5 2.5 2.5 2.5 42PHQ007,007K, 009, 009K 2.5 2.5 1.5 1.5 1.5 1.5 42PHQ012, 012K, 014, 014K 2.5 2.5 2.5 2.5 2.5 2.5 Model R C Y O W2 S 42PHW018, 024 1.5 1.5 1.5 42PHQ018, 018K, 024, 024K 1.5 1.5 1.5 1.5 1.5 1.5 Terminal box legend, all models L Live power supply N Neutral power supply R Live connection indoor/outdoor unit. C Neutral connection indoor/outdoor unit. Y Compressor contact. O Reversing valve control W2 Outdoor fan S Outdoor coil sensor Power supply Connecting wire, indoor-outdoor units. Indoor unit Outdoor unit Main switch Time-delay fuse or circuit breaker (see outdoor unit installation manual) GB - 11

Operating test and address switch - Guide for the owner and accessories Operating test This procedure is used to check the operation after unit installation. Press the EMER. button continuously for 5~10 seconds. The unit will now be in Test Mode. Press the EMER. button once more after checking, to activate the remote control. If there is any input signal (remote control signal or EMER. button press) during test operation, the TEST mode will change to the input signal mode. The setting conditions of the test operation are as follows: - Operating mode: COOL - Fan speed: HIGH - Timer mode: Disabled - Discharge air direction: SWING I /O MODE EMER. SLEEP TEMP. FAN FLAP NOTE: Indoor fan speed will be "HIGH" in Test operation. The swing motor will operate when the indoor fan is operated. Operate the unit in accordance with the Owner's Manual and check the following: a. Indoor unit. - Do all switches operate normally? - Does each light come on normally? - Do the horizontal louvres operate normally? - Is the drain correct? b. Outdoor unit. - Is there any abnormal noise or vibration during operation? - Is there any gas leakage? A B CLOCK EVERYDAY HOUR MINUTE TIMER ON OFF SET CANCEL Address switch RST TA If you are installing two indoor units in the same room, it is necessary for you to assign each unit its own address so each can be operated by its own remote control. One address switch is on the back of remote control, and the other is in the PCB side. The address switch is set to A when you purchase the unit. Guide for the owner Guide for the owner When installation and tests are completed explain the Operation and Maintenance Manual to the owner, with particular attention to the main operating modes of the air conditioner, such as: Turning the unit on and off. Address switch Remote control - Remove the lid of the battery case. - Assign the address switch of one remote control to B. - Press the RST button with a sharp object. Indoor unit - Turn off the unit and pull out the power plug. - Remove the front panel and terminal block cover. - Assign the address switch of one indoor unit to B. Functions of the remote control. Removal and cleaning of the air filters. Leave the two installation manuals for the indoor and outdoor units with the owner for future use during maintenance operations or for any other needs. Table IV : Accessories Description Active carbon filter and electrostatic filter Photocatalytic filter and electrostatic filter Part number 42PHW9100 42PHW9101 42PHW9102 42PHW9103 42PHW / 42PHQ / 42PHQ...K 007 009 012 014 018 024 GB - 12

42PHQ...N The General Information For Multi or T-kit model The configuration setting by remote controller Entering Configuration Mode Press the MODE (2) button together with the FLAP (3)button for 7 continuous seconds while remote is in OFF mode. 2) Step: Unit configuration Display : CFG Default Value : HP Available Value : HP Heat Pump AC Cool Only 3) Step: Transmit and Go to next step Press FLAP button and then MODE button. 4) Step: Application selection Display : GFd Default Value : 1 Available Value : 1 238 : Mono (1x1) 239 : T-Kit 240 : Multi 5) Step: Transmit and Exit configuration mode LCD will display the following message: Press FLAP button and then I/O button. In case of first use or after battery change, default values will be displayed. [CFG/HP] Once user has changed configuration, the new stored values will be displayed. 6) Step: System reset After changing configuration by remote, TURN OFF AND THEN ON ELECTRIC POWER SUPPLY to the system to make configuration effective. Configuration Procedure MODE (2) Button - Selects the different configuration items: AC HP and Mono T-Kit Multi application (please refer to Example). and (4) Buttons Increase or decrease the displayed value. Once a value is changed, it flashes until the FLAP (3) button is pressed. FLAP (3) Button - Transmits a configuration message for the parameter that is displayed. If user wants to configure more than one parameter, the FLAP (3) button must be pressed step by step until each parameter is being displayed. I/O (1) Button - To exit Configuration Mode, and return the LCD display back to its previous operating condition (OFF mode). If there is no key-in during 30 continuous seconds, the remote will exit automatically the Configuration mode. The parameter is set back to its latest transmitted value. Example : 1) Step: Enter configuration mode Press MODE and FLAP buttons together for 7 seconds. The Operating Test for Multi or T-kit model This procedure is used to check the operation after unit installation. Press the EMER. button continuously for 5-10 seconds. The unit will now be in TEST mode. Press the EMER. button once more after checking, to return to normal operation. If there is any input signal (remote control signal or EMER. button press) during test operation, the TEST mode will return to normal operation. The setting conditions of the TEST operation for Multi or T-kit model are as follows. - Operation LED : ON - Timer LED : Blink ON for 0.5 seconds and OFF for 0.5 seconds four(for T-kit model) and three times(for Multi model) - Operating mode : Cool mode for 3 minutes, firstly and then Heat mode for 2 minutes and Cool mode until test mode is exited - Fan speed : High - Timer mode : Disabled - Discharge air direction : SWING Carrier Korea Operation

42PQ5E5440 Via R. Sanzio, 9-20058 Villasanta (MI) Italy - Tel. 039/3636.1 The manufacturer reserves the right to change any product specifications without notice. Order No. 14487, November 2001. Supersedes Order No. (new). Printed in Korea