communicall connect solutions sheet What is Communicall Connect? Who is it for? What does it consist of?

Similar documents
Solution Sheet. Communicall Vi. Leading housing technology solutions for supported living

Solution Sheet. Communicall Vi. Leading housing technology solutions for supported living

Smart Hub. Connecting people, connected care. What is it? Who is it for? How does it work?

Installation and user guide

Lifeline Vi Clever, not complicated

Lifeline 400 user guide q6 18/2/04 10:56 am Page 2. Lifeline 400. installation and user guide. Part Number D B

Total Housing Solutions. Communication systems for grouped dwellings Fire systems Door entry and access control Service and maintenance

Communicall Vi IP. Unleashing the power of digital communications

Quick set-up guide. [Simple plug and play system]

ADVENT xt WARDEN CALL SYSTEM V2.0 OPERATORS MANUAL

TYNETEC. Telecare for independent living THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES MOBILE NETWORK

Telecare Equipment Guide

DISABLED TOILET / EMERGENCY ASSISTANCE ALARMS

Your Lifeline Vi+ home unit. Your MyAmie pendant

D C. Caresse GSM Installation and Programming Guide

Operators Guide ENGENIUS EP800 CORDLESS TELEPHONE

EMERGENCY ASSISTANCE ALARMS

Smart Hub. User & Installation Guide

Telecare User Guidance

issue 23 Portfolio telehealthcare solutions Issue number 23

CALL FOR A FREE SURVEY

Connectivity: This is a stand-alone product; no Wi-Fi or other wireless connectivity.

USER & INSTALLATION GUIDE

NON-MONITORED EMERGENCY CALL SYSTEMS

SeCom Combining communication and security in retirement- and nursing homes

Security Alarm Systems

The following equipment is included in your Tunstall Home box t :

Tunstall Vi+ User Guide

GX-Cubic1 Smart Care Medical Alarm Solutionon. Caring for Your Health and Personal Safety

arm wire free solutions nurse call personal security fire alarms

ezone Alert System ezone is a UK designed and manufactured care alerting system unlike any other comparably priced system.

GX-Cubic1 Smart Care Medical Alarm Solutionon. Caring for Your Health and Personal Safety

Session VI Smart safety systems

Connect your panel to any local area network

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

Programming the Vi+ using a Series Telephone. Tunstall Vi+

Vibby. Installation Guide. t: f: e: w: uk.tunstall.com Version: V3.9

ACP10 & ACP50 Security Systems

Digital Door Entry System. Specification

169MHz Telecare Devices Deaf Smoke Alarm Kit

Lone Worker Duress Security Hazard Zone Remote Area Health Care DURESS & SAFETY TECHNOLOGIES I N T E R N A T I O N A L

Elderly Care Alarm System

User Guide. Contents. About this guide. i-on Style Security System

Universal Sensor. Installation Guide. t: f: e: w: uk.tunstall.com Version: V2.97 (421V0R1.

3800 Quick Hill Road, Austin, Texas 78728

SERENITY. Crow s Passion for Smart Residential Security.

Technology Enabled Care Solutions Guide from Chubb Community Care Connecting people with care.

EURO 46 V10 User Manual

Howler Go-Link Evacuation Alarm

GMS GRAPHICAL MANAGEMENT SYSTEM

SilentMAlert. ClofieldMLimited. ProductMDataMSheetsM. PagingMSystem. Silent

Clofield Limited. Product Data Sheets. Paging System. Care Call. Preventative monitoring for homecare... Wireless alerting system for Carers

SECURIT 703 USER MANUAL

Home Automation. Product info. Marketed By: BlueSilica Technologies For further details write to

USER & INSTALLATION GUIDE

Now Compa ble With. VL Touchscreen Alarm. Crafted Touchscreen Security System that Revolutionizes Your World. illi tl C

Installation Manual Premier 412/816/832. Issue 10

GUIDE TO LONE WORKER SAFETY. Which lone worker alarm devices are right for your environment and how to distribute alarm messages

English. Doro CareIP Mobile. User Guide

A Beginners Guide to Inner Range Systems

SeCom. Combining communication and security in retirement- and nursing homes

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

169MHz Telecare Devices Universal Transmitter

USER MANUAL CEF AP28 CONTROL PANEL

Web Services are based on Apache and Tomcat servers. The html/jsp (tags, beans) are fully customisable and extendable.

WIRELESS ALARM SYSTEM CR200 >SMART GPRS INTRUSION DETECTION PLUG & PLAY FUNCTIONS SELF-LEARNING, SMART FEATURES TEXT ZONE NAMING

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Secure Your Way of Life. Now Compa ble With. Vesta Smart Security Solution ML Series

Sintony 60 security meets design

Security System. User s Guide for the Text Command Center

Integrated Security Solutions

169MHz Telecare Devices Heat Detector

User Guide. HTM Nurse Call. In the event of requiring assistance, please contact your Installer/Supplier.

2G & 3G GSM Door Contact Alarm

Technical Bulletin Bulletin Number: 2012_02 Released: 1 st May 2012

D B Version 9.9. Lifeline Vi/Vi+ Installation and Programming Guide

Control Panel User Guide

USER GUIDE HARDWIRED CONTROL PANELS

Operation - the PIR internal movement sensor. Operation - the tilt sensor. Operation - awning light. Operation - marker / tail lights

Memcom Emergency Telephone

i on Compact Security System

2G & 3G GSM Portable PIR Alarm

Galaxy Flex V3. User Guide. Honeywell Security. This user manual is located at

Secure Your Way of Life. Now Compa ble With. Vesta Smart Security Solution - MZ Series

All tested. Easy Series Intrusion Control Panel Making security easy featuring wlsn* * wireless Local SecurityNetwork

REPEATER FS5200R OPERATION MANUAL

DATAssure. Laboratory wireless alarm & monitoring system

Wireless security products

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

Introducing Sentry Interactive

Maintaining your independence with 24/7 technology support. A wide range of assistive technologies to support independence and well-being

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Entrotec DESIGNERS AND MANUFACTURERS OF DOOR ENTRY, ACCESS CONTROL AND TELECARE SOLUTIONS FOR SOCIAL, PRIVATE AND INDEPENDENT LIVING ENVIRONMENTS

NextGen Home Security. Quick Reference Guide

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

GSM RFID VOICE Alarm System

Transcription:

solutions sheet communicall connect What is Communicall Connect? Communicall Connect is Tunstall s most advanced grouped housing communication system. Its innovative design builds upon the success of Tunstall s established Communicall range whilst ensuring that simplicity of use and reliability are the most important assets. Its unique use of the internet will allow your facilities to be tailored to different care applications by providing a flexible telecare enabled communication system, utilising the very latest technology. It will also provide a number of new benefits to both your staff and residents and support the process of remodelling care using telecare technology. Who is it for? Communicall Connect is a communication system that meets the needs of today whilst providing the ability to adapt to resident s changing telecare needs over time by allowing care staff to easily change individual resident settings remotely over the web. It therefore offers a future proofed system for care providers who may wish to remodel care provision through the use of telecare. It can quickly and simply transform care provision through the implementation of the most flexible telecare system on the market today. Its key new features include: Individual telecare settings per resident Easy configuration via web browser or system control panel Improved resident speech module What does it consist of? Communicall Connect utilises a new control unit and modern speech module to create a system capable of remodelling care provision through the use of individually tailored telecare. The combination of the two provides enhanced features to support both the care provider and resident. Innovative new web browser allows settings to be quickly changed

It can help transform your facilities into true extra care facilities by replacing your existing communication system with a flexible telecare enabled system utilising the very latest technology. Effectively meeting the challenges The key to Communicall Connect is its ability to provide an integrated approach to telecare that is completely flexible and can be set for each individual resident rather than the system as a whole. Its enhanced telecare features make it an ideal solution for a range of care models by: Supporting residents to maximise their independence Providing a 24 hours a day communications system for residents and staff Enabling flexibility so that the solution that can evolve to meet the changing needs of individual residents Providing additional support to residents that allows them to be discharged earlier from hospital Providing a single source of supply and service for call systems with combined door entry (including Concierge facility), fire alarm, emergency lighting, security systems and telecare sensors Tailored solutions can also make life easier for residents with reduced mobility. A remote door entry controller allows control of entry without having to leave your chair and pictures of the visitor can be shown on the resident s television if required. Similarly, additional lights, sounders or pagers can be supplied to provide further reassurance for users with hearing or visual impairments. Latest features Modern Speech Module - designed to complement the modern home environment, the new speech module offers the following features; - Message waiting - the new speech module encompasses an LED that flashes when a message has been left on the system for the resident from the scheme manager. - Simple to use - unobtrusive with integral alarm button, pullcord and privacy button and optional door entry buttons which are simple to use. - High quality two-way speech - handsfree voice switching (HVS) speech provides a more natural form of communication than either push to talk or VOX based systems. - Test Mode - enables scheme managers to substantially reduce the time taken to test pullcords and any other wired devices so freeing up time for more productive tasks. - Easy to upgrade - can be easily and economically upgraded to add functions later such as door entry and/or an intruder system. - Intruder function - provides the ability to set up a simple to use intruder system within resident s homes.

Latest features TT21 protocol - the web-based configuration interface protocol is a simple to use programming panel specifically designed to offer complete support for modern telecare services by allowing event and location information to be provided for all telecare sensors and by supporting encryption to enable exchange of health information to be sent in the future. 21CN compliant - system supports BT s 21CN network ensuring all alarm information will continue to be presented correctly to the monitoring centre after the roll out of BT s 21CN network. Simple to set up - settings can easily be changed both locally and remotely using the easy to use System Control Panel (SCP) or over the internet via a web browser. The SCP provides a simple way for scheme managers to add/remove telecare sensors whilst the web browser allows scheme managers to remotely carry out more in depth programming. Text messaging to scheme manager - upon activation of an alarm the scheme manager is provided with details of the alarm via a text message on their DECT or GSM handsets. Remote door control - a special radio trigger can be used to provide cost effective remote door control. Personalised alarm call messages - the system enables the scheme manager to locally record alarm messages specific to an individual resident e.g. alarm call from Mrs Smith. Enhanced call routing - the system has a local off site mode which provides the scheme manager with the ability to temporarily divert alarm calls to their mobile phone rather than offsite to the monitoring centre. Built in Check-It functionality - a cost effective method of providing continuous telephone line checking to provide additional safety and protection to residents.

Main features Class one radio receivers - radio receivers meet the Class One requirements, for safety critical systems, of EN300 220. The use of non class one receivers can mean that alarm calls from personal triggers or other radio devices may not be received reliably. Choice of personal radio trigger - option of a choice of personal radio trigger (Amie+ or Gem+) with a variety of wearing options can be provided to meet individual resident requirements. Telecare easily tailored to individual needs - transforms your system into a fully integrated telecare platform with enhanced features designed specifically for telecare users including; - Individual settings per flat/user - ensures care provision is completely flexible and designed to meet individual needs. - Cancel at source - can be set individually per resident to ensure a response to the source of alarm calls by care staff. - Locatability of personal trigger alarms - on activation of a resident s personal trigger the system automatically provides location information to the scheme manager to help them respond quicker. Easy to use system configuration - setting up individual telecare settings per resident is simple via a web browser or simplified system control panel Interactive voice response - the fully customisable voice messaging system provides a simple way for scheme managers to alter scheme settings and respond to alarm calls. Recordable messages - Upon activation of an alarm the scheme manager will receive a voice message to their handset saying the resident s name that generated the call and the sensor/trigger that was activated. Smart call management - alarm calls can be grouped by type or time and can be directed to the appropriate person/monitoring centre eg auto battery low alarms can be directed to a maintenance team or high dependent residents can be directed to a specific care team. Multiple call destinations are available which can include a combination of DECT, mobile (GSM) or monitoring centre numbers. Enhanced system integrity & reliability - a large number of additional safety features have been added including: - Continual system monitoring - the system automatically self-checks and generates the appropriate fault reports. - Backing up of system settings - all system settings including telecare settings per resident are automatically backed up and stored on a Multi Media Card (MMC) to ensure the settings are quickly transferable. Logging of events - all events generated on the system are stored on the MMC for audit purposes. Future proofed - the system is Ethernet enabled to allow for future developments using internet technologies. Smoke Detector Flood Detector Sounder Beacon PIR (Movement Detector)

Optional features Auto Line Isolation Unit (ALIU) ALIU provides added protection for residents by ensuring that the scheme continues to operate despite damage to part of the system. For example, if the scheme suffers from lightning damage then the affected area can be isolated enabling the rest of the scheme to continue working whilst the damage is repaired. Combined door entry and video Door entry can be easily and cost effectively fitted to Communicall Connect. Resident speech modules have additional buttons added including door entry privacy. The door panel will allow visitors to call either residents or on- site staff. When in off-site mode the monitoring centre also has the option to be able to view and speak to the visitor before releasing the lock, using the same workstation. DDA door panel An enhanced DDA door panel also provides HVS speech and an LCD display to allow visitors with hearing or visual impairments to gain access to the scheme. Features include audible user instructions, illuminated visual display, door open indicator, raised pip on central button 5 and dedicated trades button. Remote door controller Residents with limited mobility can use the remote door controller to control their door entry system without needing to leave their chair. Remote release safe Alarm calls received, when the scheme is monitored remotely, may result in emergency services requiring a means of accessing a master key to enable access to a resident s dwelling. The remote release safe can hold the master key securely and be opened by the monitoring centre when required. Door open alert Typically used to protect fire exits and the main front door, the door open alert generates an alarm if the door is left open and therefore vulnerable to unauthorised people entering the scheme. Link to fire alarm panel When the fire panel is activated it may also raise a call on the system. This ensures that the monitoring centre is aware of the situation on site and can take appropriate action. Suitable outputs from other equipment may also be linked to the system eg boiler fail alarm. Fireman s switch Usually located externally near the door panel, the switch enables the fire services to release the lock on the main front door. Call panel Where combined door entry may not be required, then a means for visitors to be able to call the manager from an external point is often required. The call panel is a single button panel designed to meet this need. It may also be used as a call point from a lift. Key fob system The management of keys to the main scheme door can become an issue. The key fob system provides a fob for every resident and staff as required. Fobs can be easily added or deleted on-site so aiding the overall security of the site. In addition, residents with limited dexterity often prefer the usability of a fob over a key. Mobile phone/pda with mobile phone With the reducing costs of mobile phones and increased coverage they are increasingly being used as an alternative to DECT systems. They are particularly useful on sites that are quite dispersed or those consisting mainly of disparate bungalows. The mobile phone provides all the same functions as the DECT handset but alarm calls from a resident to the mobile will be charged to the scheme phone line. On a whole of life basis the costs may be lower than a DECT system. Broadcast speech Messages that need to be communicated to all residents immediately can be broadcast from either the DECT handset, a mobile phone or from a PNC monitoring centre.

Technical details Speech module: Includes integral alarm button, pullcord and privacy button System capacity: Dimensions: Weight: Options include: DECT infrastructure: Handset: Weight: Batteries: Frequency band: RF output power: Maximum handsets: Maximum number of bases: 16 Maximum number of speech channels: Control equipment: Batteries (typical system): 204 standard, 459 expanded 110 x 175 x 55mm (WxHxD) 310 g Basic, with door entry, away, broadcast speech 48 x 143 x 26mm (WxHxD) 121 g 1 nickel metal hydride rechargeable pack with 12 hours talk time or 120 hours standby 1880-1900MHz 250mW max 7 (more dependent on PBX) 4 per base 2x12v 12AH Lead acid battery support for 8 hours Optional support for DECT infrastructure 220/240 V ac 50Hz 40V Power supply: System voltage: Number of radio devices per scheme: 500 Receiver radio frequency: 869.2125Mhz. Compliant with the dedicated social alarm frequency Optional door entry: Panel dimensions: 236 x 366 x 40mm (WxHxD) Back box dimensions: 212 x 342 x 70mm (WxHxD) Door panels: Maximum 8 Standards: LVD: EN 60950 EMC: EN55022, EN61000-3-2, EN61000-3-3, EN50130-4 Radio triggers: EN300 220-3, EN300 683 Radio receivers: ETSI EN300 220-2 (2007) Class 1 System: EN50134-3 CE: Compliant Design, manufacture, installation and Service ISO9001:2000 Class 1 Please Note: A Class 1 receiver is necessary for Safety Critical SRD (Short Range Device) communications media where failure my result in a physical risk to a person. Some photographs are for illustration only. Actual product may vary. www.tunstallgroup.com Tunstall is a founder member of the Continua Health Alliance Our policy of continual development means that product specification and appearance may change without notice. Tunstall does not accept responsibility for any errors and omissions contained within this document. 2008 Tunstall Group Ltd. TUNSTALL, COMMUNICALL and LIFELINE are registered trademarks. Tunstall Group Limited, Whitley Lodge, Whitley Bridge, Yorkshire DN14 0HR Tel: 01977 661234 Fax: 01977 662450 Email: enquiries@tunstall.co.uk 0123/4/08