Input module, input/output module

Similar documents
Input module, input/output modules

Multi line separator module

Output module (230 V)

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

FDCIO223 (ES 45) Transponder

Mimic display driver, LED ribbon cable

Interbases. Sinteso FDSB221, FDSB228, FDSB229

FDCL221-M Multi line separator module

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

OH720, OP720, HI720, HI722

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

FDOOT221, FDO221, FDT221

ASA linear smoke detector

FDOOT241-9, FDOOT241-A, FDO241, FDT241

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

DM1131 / DM1133 / DM1134 Manual call points

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

FDOOT241-A9-Ex Multisensor fire detector

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

FDCL221-Ex Line adapter (Ex)

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

FDBZ290 Air sampling smoke detection kit

FDBZ290 Air sampling smoke detection kit

Fire control panels FC360

FC2040. Fire control panel. Sinteso. FS20 series, MP6

SWING radio fire detection system

FDCW241 Radio gateway Mounting

Fire control panel for modernization

FDCI221, FDCIO221 Input module, input/output module Technical Manual

OOH740-A9-Ex Multisensor fire detector

OOH740, OOHC740 Automatic fire detectors

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

FC724 Fire control panel

FC724 Fire control panel

FC722 Fire control panel

Fire control panels FC726 FC726-XA

OOH740-A9-Ex Multi-sensor fire detector

FC723 Fire control panel

DC1192 Input /Output module

DF1101-Ex Infrared flame detector

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

Radio fire detection system

FC722 Fire control panel

FC2020 Fire control panel

DT1101A / DT1102A / DO110xA Automatic fire detectors

FP120-Z1 Power supply kit A (70 W) Technical Manual

FDCL221 Line separator

FT2080 Fire terminal (Touch) Mounting Installation

FT2080 Fire terminal (Touch) Mounting Installation

Room thermostat with 24-hour time switch and large LCD

Test units and accessories

Sinteso TM product catalog.

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

FS20 Fire detection system

Test units and accessories

Electronic timeswitch

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Synova TM product catalog.

FDM273 Radio manual call point Mounting

Call stations and extensions

FDL241-9 Linear smoke detector Mounting Commissioning

Frost Protection Thermostat

Room Temperature Controllers

RVL479. Heating Controller. for use with a partner unit

1592P01. for liquids in piping DN

XC10 Extinguishing control panels

FDA241, FDA221 Siemens ASD

Flush-mounted room thermostat

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

2015 NEW. Cerberus ECO. enjoy protecting. Product Brouchure. siemens.com/buildingtechnologies

DF1151-Ex Infrared flame detector

FDBZ290 Air sampling smoke detection kit Technical Manual

Duct Temperature Sensors

Room Temperature Controller

FDCIO223 Input/output module (transponder)

DOW1171 / DCW1151 Radio fire detection system

Test units and accessories

Room Temperature Sensors

FDCIO223 Input / output module (transponder)

Fire safety products and accessories siemens.com/cerberus

Room thermostats with LCD RDD100..

FS720 Fire detection system (marine) Technical Manual

Wall-mounted room thermostat with LCD

Use. For 2-pipe fan coils

FDA241, FDA221 Siemens ASD

Semi flush-mount room thermostats

FDS229 Alarm sounder with supplementary optical indication Technical Manual

Wireless room thermostat with LCD

Frost Units for air temperature monitoring

OH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual

Flush-mounted room thermostats

Room thermostat with independent DHW control

Transcription:

Sinteso / Cerberus PRO Input module, input/output module FDCI221, FDCIO221 Input module and input/output module for the automatically addressed detector line Input module FDCI221: Monitorable contact input for reporting technical statuses or activating an alarm Input/output module FDCIO221: Control output with potential-free relay contact for activation of alarming devices, fans, air conditioning systems, lift controls, etc. Monitorable contact input for reporting technical statuses or activating an alarm Use as a monitored output with a separate power supply, e.g., for operating acoustic signal transmitters LED indicator for input/output statuses and for fault, test, localization Power supply and communication via (addressed individually) Address automatically issued during commissioning Two-wire installation for all cable types 2018-06-15 Control Products and Systems

Properties Functions Features Transparent housing, ensuring that indicators are easy to see Protected electronics Integrated line separator Chronological status monitoring Supply via, auxiliary supply only required if the output is configured as monitored (FDCIO221) Microprocessor-controlled signal processing Different mounting options For dry areas In humid environments, use additional housing FDCH221 Eco-friendly Environmentally friendly processing Reusable materials Electronic parts and synthetic materials can be easily separated FDCI221 input module Input for potential-free detector contact Monitoring the input line for open line and short-circuit with terminating resistors The input for status or alarm messages can be configured using the fire control panel. Status indicator by means of LED Fields of application: To activate a potential-free normally open or normally closed contact in order to report technical statuses (e.g., door or fan control) or to activate an alarm (e.g., sprinkler alarm) 2 1 3 1 Potential-free detector contact 3 Connections for the detector line 2 Connections for the input 2

FDCIO221 input/output module Input for potential-free detector contact Monitoring the input line for open line and short-circuit with terminating resistors The input for status or alarm messages can be configured using the fire control panel. Output which can be configured via jumper: Not monitorable: Potential-free relay contact (AC 22 V, 2 A or DC 30 V, 2 A) Monitorable: Relay contact (DC 30 V, 2 A) Status indicator by means of LED Fields of application: To activate a potential-free normally open or normally closed contact in order to report technical statuses (e.g., fan control) or to activate an alarm (e.g., sprinkler alarm) For decentralized activation of alarming devices, fans, air conditioning systems, lift controls, etc. 2 1 4 3 1 Potential-free detector contact 3 Connections for the detector line 2 Connections for the input 4 Connections for the output 3

Type Overview Type Designation Order number Weight [kg] FDCI221 FDCIO221 Input module incl. 2 resistors, 2 mounting feet Input/output module incl. 2 resistors, 2 mounting feet S54312-F1-A1 0.060 S54312-F2-A1 0.066 Accessories for input module FDCI221, input/output module FDCIO221 Type Designation Order number Weight [kg] FDCH221 Housing with cover, seal, and screws S54312-F3-A1 0.282 M20 x 1.5 metal cable gland A5Q00004478 0.036 M20 metal counter nut A5Q00004479 0.006 DBZ1190-AB 0.5 2.5 mm 2 (3-pin) connection terminal BPZ:4942340001 0.001 Replacement material for input module FDCI221, input/output module FDCIO221 Type Designation Order number Weight [kg] FDCM291 Mounting foot A5Q00003855 0.001 Product documentation Document ID Name 008164 Equipment overview Sinteso Detector system FD20 008331 List of compatibility (for 'Sinteso ' product line) A6V10229261 List of compatibility (for 'Cerberus PRO' product line) A6V10211122 Technical Manual Input module FDCI221, input/output module FDCIO221 A6V10212086 Installation Input module FDCI221, Input/Output module FDCIO221, Housing FDCH221 Related documents such as environmental declarations, CE declarations, etc., can be downloaded at the following Internet address: http://siemens.com/bt/download 4

Notes Mounting Mounting options Directly on the mounting surface Series mounting on a U-rail TS35 Surface-mounted or recess-mounted cable entry In housing FDCH221 (accessory) with cover, seal, and screws for wet areas 1 3 2 1 Series mounting using mounting feet supplied, on U-rail TS35 2 Mounting in housing FDCH221 (accessory) 3 Use auxiliary terminals DBZ1190-AB for shielded cables Disposal The device is considered an electronic device for disposal in accordance with the European Guidelines and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. 5

Technical data Operating voltage FDCI221 FDCIO221 DC 12 33 V Operating current (quiescent) Max. 0.3 ma Max. 0.4 ma Relay output (ohmic) - AC 22 V, 2 A, max. 44 VA DC 30 V, 2 A, max. 60 W Line resistance (input) Max. 20 Operating temperature -25 +70 C Storage temperature -30 +75 C Air humidity (non-condensing) Communication protocol Connection terminals Color Housing Cover Housing FDCH221 Protection category (IEC 60529) When mounted on a U-rail in a fire control panel With housing FDCH221 95 % rel. 0.2 2.5 mm² ~RAL 9010, pure white Transparent matt ~RAL 9010, pure white Standards EN 54-17, EN 54-18 Approvals VdS LPCB FM DNV GL (Marine) System compatibility FDnet C-NET G209066 531h/01 3038448 IP30 IP65 MEDB00003UU FS20 FS720 G209067 531h/02 3038448 10 10 0786 FDCI221 Siemens Schweiz AG; Theilerstrasse 1a CH-6300 Zug Technical data: see doc. A6V10211122 FDCI221 - Input/output device incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-17 / EN 54-18 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or https://siemens.com/bt/download DoP No.: 0786-CPR-20709; DoC No.: CED-FDCI221 0786 FDCIO221 Siemens Schweiz AG; Theilerstrasse 1a CH-6300 Zug Technical data: see doc. A6V10211122 FDCIO221 -Iinput/output device incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-17 / EN 54-18 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or https://siemens.com/bt/download DoP No.: 0786-CPR-20710; DoC No.: CED-FDCIO221 6

Dimensional drawings Input module FDCI221 71 24 95 91 Input/output module FDCIO221 71 24 95 91 Housing FDCH221 119 50 207 7

Issued by Siemens Switzerland Ltd Division International Headquarters Theilerstrasse 1a CH-6300 Zug Tel. +41 58 724 2424 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2009 Technical specifications and availability subject to change without notice. 8 Document ID Manual FD20/FD720 Edition 2018-06-15 Register 5