Performance Characteristics of a Refrigerator- Freezer with Parallel Evaporators using a Linear Compressor

Similar documents
The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Control Method Of Circulating Refrigerant Amount For Heat Pump System

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Performance Evaluation of a Plug-In Refrigeration System Running Under the Simultaneous Control of Compressor Speed and Expansion Valve Opening

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Purdue e-pubs. Purdue University

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Analysis of Oil Pumping in the Hermetic Reciprocating Compressor for Household Refrigerators

Hunting Phenomena Of Automotive Air Conditioning Systems With Variable Displacement Compressor

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

High Efficiency R-134a Compressor for Domestic Refrigerator

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Experimental Study on the Thermal Behavior of a Domestic Refrigeration Compressor during Transient Operation in a Small Capacity Cooling System

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

Mini Vapour Cycle System For High Density Electronic Cooling Applications

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Performance Characteristic and Optimization of a Simultaneous Heating and Cooling Multi Heat Pump

The Design Of A New Generation Of Twin Screw Refrigeration Compressors

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

A study of Transient Performance of A Cascade Heat Pump System

DEEPAK PALIWAL, S.P.S.RAJPUT

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Comparison Of Hermetic Scroll And Reciprocating Compressors Operating Under Varying Refrigerant Charge And Load

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

Sub-Critical Operation of the CO2 Expander/ Compressor

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

Low Global Warming Refrigerants For Commercial Refrigeration Systems

REVIEW ON HOT GAS DEFROSTING SYSTEM FOR VAPOR COMPRESSION REFRIGERATION SYSTEM

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Comparison of Performance of a Residential Air- Conditioning System Using Microchannel and Finand-Tube

Performance Comparison of R32, R410A and R290 Refrigerant in Inverter Heat Pumps Application

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

Low GWP Refrigerants for Air Conditioning Applications

Exploring the Performance Characteristics of CO2 Cycles in a Breadboard-Type Test Facility

Performance of CO2 Cycles with a Two-Stage Compressor

Experimental Investigation of a New High Temperature Heat Pump Using Water as Refrigerant for Industrial Heat Recovery

Numerical Evaluation of Performance Curves of a High Frequency Microcompressor

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

Performance of an Improved Household Refrigerator/Freezer

Study of R161 Refrigerant for Residential Airconditioning

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

Optimization of Compressors used in Air Conditioning Units

Experimental Study of Fouling Performance of Air Conditioning System with Microchannel Heat Exchanger

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

R32 Compressor for Air conditioning and Refrigeration applications in China

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Dynamic Simulation of Liquid Chillers

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles

Real Time Upright Freezer Evaporator Performance Under Frosted Conditions

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

An Experimental Study of the Air-Side Particulate Fouling in Fin-and-Tube Heat Exchangers of Air Conditioners

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Two-Step Capacity Modulation of a Single Cylinder Compressor

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

Heat Exchanger Shelves For Better Temperature Control Of Food In Open-Type Display Cases

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Compressor Capacity Control: A New Direction

Experimental Study on the Performance of Twisted Capillary Tube

Department of MCE, Islamic University of Technology 2. Abstract

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

Systematic Study of the Solution Properties of Low Global Warming Potential R-404A Replacement Refrigerant Blends with Various Polyol Ester Lubricants

Experimental and Numerical Study on the Performance of R410A Liquid Recirculation Cycles with and without Ejectors

Theoretical and Experimental Analysis of the Superheating in Heat Pump Compressors. * Corresponding Author ABSTRACT 1.

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Effect of the Use Pattern on Performance of Heat Pump Water Heater

Noise Reduction Technology With Porous Metal for Refrigerant Two-Phase Flow Through the Expansion Valve

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

A Study on Compression Characteristic of Wet Vapor Refrigerant

Thermal Modelling for the Motor in Semi-hermetic Screw Refrigeration Compressor under Part-load Conditions

A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2016 Performance Characteristics of a Refrigerator- Freezer with Parallel Evaporators using a Linear Compressor Byungchae Min Graduate School of Mechanical Engineering, Pusan National University, Korea, Republic of (South Korea), bcmin@pusan.ac.kr Sangjin Song Graduate School of Mechanical Engineering, Pusan National University, Korea, Republic of (South Korea), songsj@pusan.ac.kr Kiyoul Noh Graduate School of Mechanical Engineering, Pusan National University, Korea, Republic of (South Korea), nky0317@pusan.ac.kr Geonwoo Kim Graduate School of Mechanical Engineering, Pusan National University, Korea, Republic of (South Korea), kwkim@pusan.ac.kr Teaseung Yoon Graduate School of Mechanical Engineering, Pusan National University, Korea, Republic of (South Korea), tsluv89@pusan.ac.kr Min, Byungchae; Song, Sangjin; Noh, Kiyoul; Kim, Geonwoo; Yoon, Teaseung; Na, Sangkyung; Song, Sanghoon; Yang, Jangsik; Choi, Gyungmin; and Kim, Duckjool, "Performance Characteristics of a Refrigerator-Freezer with Parallel Evaporators using a Linear Compressor" (2016). International Refrigeration and Air Conditioning Conference. Paper 1777. http://docs.lib.purdue.edu/iracc/1777 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

See next page for additional authors Follow this and additional works at: http://docs.lib.purdue.edu/iracc

Authors Byungchae Min, Sangjin Song, Kiyoul Noh, Geonwoo Kim, Teaseung Yoon, Sangkyung Na, Sanghoon Song, Jangsik Yang, Gyungmin Choi, and Duckjool Kim This article is available at Purdue e-pubs: http://docs.lib.purdue.edu/iracc/1777

2500, Page 1 Performance Characteristics of a Refrigerator-Freezer with Parallel Evaporators using a Linear Compressor ` Byung-chae Min 1a, Sang-jin Song 1b, Ki-youl Noh 1c, Geon-woo Kim 1d, Tea-seung Yoon 1e, Sang-kyung Na 1f, Sang-hoon Song 2, Jang-sik Yang 3, Gyung-min Choi 4a*, Duck-jool Kim 4b 1 Graduate School of Mechanical Engineering, Pusan National University, Busan, South Korea (Phone: +82-51-510-3072, E-mail : a bcmin@pusan.ac.kr, b songsj@pusan.ac.kr, c nky0317@pusan.ac.kr, d kwkim@pusan.ac.kr, e tsluv89@pusan.ac.kr, f naskng@pusan.ac.kr ) 2 Engineering Design Department, Refrigeration, LG Electronics Changwon, Gyeongsangnam-do, South Korea (Phone : +82-55-260-3367,,E-mail: sanghun.song@lge.com) 3 Rolls-Royce University Technology Centre, Pusan National University Busan, South Korea (Phone: +82-51-510-3239 E-mail: yangjs@pusan.ac.kr) 4 Department of Mechanical Engineering, Pusan National University, Busan, South Korea (Phone: +82-51-510-2476 E-mail: a* choigm@pusan.ac.kr, b djkim@pusan.ac.kr) * Corresponding Author ABSTRACT A linear compressor for a domestic refrigerator-freezer has energy saving potential compared with a reciprocating compressor because of a low friction loss and free piston system. A linear compressor can control the piston stroke since it does not have mechanical restriction of piston movement. Therefore, the energy consumption of a domestic refrigerator-freezer using a linear compressor can be reduced by changing the cooling capacity of the compressor. In order to investigate the performance of a refrigerator-freezer with parallel evaporators using a linear compressor and the relation between cooling capacity of the linear compressor and cooling load, experimental simulation is conducted with variation of the capacity of a linear compressor, an ambient temperature, and cooling load. In addition, the power consumption of a linear compressor is compared to that of an inverter reciprocating compressor in a refrigerator-freezer. The performance of a linear compressor is measured with variation of the capacity of a linear compressor from 60% to 100% of the maximum capacity in a refrigerator-freezer. Based on the experimental data, the power consumption of a linear compressor is reduced by 22.4% with 70% capacity compared to 100% but on-time ratio is increased by 12.8%. 1. INTRODUCTION Recently, a linear compressor has been adopted for domestic refrigerator-freezers due to its potential to reduce the energy consumption with some refrigerator manufacturers. However, in many refrigerator manufacturers, a reciprocating compressor is used for a domestic refrigerator-freezer. The mechanical loss of conventional reciprocating compressors is higher than that of a linear compressor because of four friction regions to generate friction loss by a crank-driven mechanism. On the contrary, a linear compressor has one friction region between a piston and a cylinder. Therefore, a liner compressor is the most efficient compressor due to its low friction loss, simple refrigerant flow path and highly efficient linear motor (Kim and Jeing, 2013). In addition, the noise level of linear compressors is lower than that of conventional reciprocating compressors due to the small number of friction regions. The linear compressor does not have mechanical restriction to piston movement. Hence, the cooling capacity of a linear compressor can be modulated by a piston position controller in accordance with the variation of

2500, Page 2 Figure 1 Schematic diagram of a linear compressor cooling demand. Lee et al. (2000) applied Triac, which control the AC voltage in order to control piston stroke. Chun and Ahn (2008) applied a PWM(Pulse Width Modulation) inverter to the compressor. However, stroke controllers such as Triac and PWM inverter need costs to be applied to the compressors and power to run. The control logic is complicated because the piston stroke is influenced by many operating conditions. Kim et al. (2011) investigated an inherent capacity modulated(icm) linear compressor without using stroke controllers. This compressor without a drive has a great advantage to reduce power consumption and cost and enhance compatibility with various types of refrigerators. In this paper, the possibility of self-modulation for cooling capacity is presented. The stroke increases with reduction of the gap between TDC and the piston. The smaller this distance is, the greater capacity the compressor can produce. The linear compressor has several advantages such as potential to reduce energy consumption and self-modulation. However, there is hardly any study on the performance characteristics of a refrigerator-freezer using a linear compressor in the literature. The objective of this work is to investigate the performance of the refrigerator-freezer with using a linear compressor. The operating characteristics of the linear compressor are figured out with variation of the ambient temperature and compressor cooling capacity in a refrigerator-freezer with parallel evaporators. In addition, the power consumption of a linear compressor in a refrigerator-freezer is compared to that of an inverter reciprocating compressor in order to find advantages of the linear compressor. 2. RELATED THEORIES FOR A LINEAR COMPRESSOR Fig.1 shows a simple schematic diagram of a linear compressor. A linear compressor consists of a piston, a mechanical spring, a suction and a discharge valve and a linear motor. The piston is driven by the linear motor and moved from the top dead center(tdc) to bottom dead volume(bdc). An oscillating motion is generated by the moving magnet of the linear motor in linear fashion. The stroke of the piston can change due to no mechanical restriction of movement. The discharge pressure increases with an increase of ambient temperature because pressure of discharge and condenser are directly influenced by the ambient temperature. The gas force and the gas spring acting on the piston are increased with rising discharge pressure. The gas spring under rising discharge pressure increases with an increase of the ambient temperature. The average gas spring, K gas,ave is expressed by Eq.(1). (1) where is the average value of the gas spring, is the discharge pressure, and is suction pressure. Eq.(2) can be formulated with combination of the mechanical, electrical and thermodynamic system.

2500, Page 3 (2) where X is the stroke amplitude, α is a motor parameter and increases as the gas spring rises like expressed in Eq.(2) is the friction damping coefficient. The current The stroke amplitude is decided by the design of the electrical impedance with a given voltage and frequency like Eq.(3) and Eq.(4). (3) When is less than 0, the stroke of the piston increases with increasing current. The details of the ICM linear compressor can be found in a literature (Kim et al. 2011). As described above, the linear compressor has an ability of self-modulation with variation of cooling demand. 3. EXPERIMENTAL SET-UP AND TEST PROCEDURE 3.1. Experimental set-up In this experiment, parallel evaporator cycle is adopted with internal volume of 0.87. Figure 2 shows schematic diagram of the experimental apparatus. The experimental apparatus consist of a linear compressor, a condenser, two evaporators, two capillary tubes and SLHX(Suction Line Heat Exchanger) with a 3-way valve and a check valve. The specifications of the experimental set-up are shown in Table 1. In parallel evaporator cycle, R- and F-cycles operate independently for each compartment cooling load with a compressor. Therefore, a 3-way valve should be installed at inlet of R- and F-capillary tube to separate refrigerant flow path into R- and F-evaporators. A check valve is also installed at outlet of F-evaporator to prevent back flow into F-evaporator during off-time because pressure in a F-evaporator is lower than a R-evaporator. The compressor capacity is controlled with a compressor driver from full capacity of the linear compressor to 60% of the full capacity, which change the piston stroke. A condenser is installed in a duct in order to assess an effect of the flow rate on the condensing temperature. The flow rate for a condenser is controlled with a blow fan and an orifice flow meter. Hot-line is connected between the outlet of condenser and the inlet of capillary tube. This is attached inside front surface of the refrigerator case in order to defrost between door gasket and refrigerator case and obtain sub-cooling degree in a refrigerator. The refrigerant mass flow rate is measured with a coriolis mass flow meter(oval engineering, CA001, Accuracy 0.2%). The mass flow meter is installed at outlet of hot-line because the accuracy of the mass flow meter is higher at liquid state of the operating fluid. K-type Thermocouples and pressure transducers are installed at inlet and outlet of each component. The pressure transducers have an accuracy of 1.0%. In addition, the experimental apparatus is installed in a constant temperature and humidity room to maintain constant ambient temperature and relative humidity. (4) Figure 2 Schematic diagram of experimental apparatus

2500, Page 4 Table1 Specifications of each component Specifications Compressor Linear compressor,(displace volume : 16.5cc) Condenser Spiral 10(R) Width (mm) Depth (mm) Height (mm) 200 180 180 F-room Evaporator 3(R) 6(C) 707 60 180 R-room 3(R) 4(C) 736 90 120 Capillary Freezer Capillary Tube 0.75mm(D) tube Refrigerator Capillary Tube 0.85mm(D) 3.2. Test procedure The performance of the refrigerator cycle with a linear compressor is measured by varying an ambient temperature, cooling capacity of the linear compressor, and cooling load in a R-compartment. The ambient temperature changes from 15 C to 30 C with relative humidity of 60%. The variation of the ambient temperature affects the cooling load for the each compartment. In this test, total power of a compressor and on-time ratio are measured and integrated for four hours after the variation of temperatures at every measured point and input power of a linear compressor is almost constant. In addition, refrigerant mass flow rate and piston stroke of a linear compressor are measured by a coriolis mass flow meter and driver software for a linear compressor. During this test, setting temperatures of F- compartment and R-compartment are -18 0.5 C and 3 1.5 C, respectively. The temperatures of each compartment for a cyclic operation are measured at center of compartments. In addition, the compressor frequency is constant, which yields 100% of the full capacity but the stroke of a piston changes owing to increasing condensing pressure. The performance of the refrigerator is measured with variation of compressor cooling capacity from 60% to full capacity at an ambient temperature of 25 C and a relative humidity of 60% (ISO 15502, N-class condition).. In this test, cooling time for the F-compartment temperature to reach setting temperature from the ambient temperature is measured. The heat of 100W is suddenly put in R-compartment by a heater under cyclic steady condition. This heat is internal cooling load as door opening and putting foods. In cooling load test, compressor power consumption and time for the R-compartment temperature to reach setting temperature of 3 1.5 C are measured in the R/F simultaneous operation. In the parallel cycle, refrigerant is trapped in a F-evaporator because pressure in a F-evaporator in lower than that in a R-evaporator. Hence, refrigerant recovery operation should be carried out after F-operation. In refrigerant recovery operation, the 3way-valve closes all refrigerant flow paths and a compressor operates simultaneously. The optimum charge amount of the refrigerant is selected based on the test result to yield lowest power consumption. Figure 3 shows the power consumption and cooling time to reach the setting temperature in a F-compartment with Figure 3 Power consumption and cooling time with refrigerant charge

2500, Page 5 Figure 4 Power consumption with compressor capacity Figure 5 On-time ratio with compressor capacity varying charge amount. As shown in Fig.3, the lowest power consumption is observed at the refrigerant charge of 100g but the cooling time to reach setting temperature of the F-compartment is relatively longer than other cases of 105g, 110g and 115g. When the charge amount of the refrigerant is over 120g, a suction temperature of the compressor decreases sharply below 0 C in F-operation mode. If a suction temperature is too low compared to ambient temperature, the compressors may be damaged. Hence, the refrigerant charge of 115g is selected as the optimum amount for the experimental apparatus. 4. RESULTS AND DISCUSSION 4.1 Reciprocating compressor vs linear compressor The performance of a linear compressor is compared to that of a reciprocating compressor with variation of compressor capacity in the ambient temperature of 25 C and relative humidity of 60%. Figure 4 and 5 show power consumption and on-time ratio for two compressors with change of compressor cooling capacity. The power consumption of a linear compressor is lower than that of a reciprocating compressor with 41.7% and 31.1% for two cases although on-time ratio is almost same in two compressor tests. 4.2 Effects of the ambient temperature The refrigerator performance is compared with variation of the ambient temperature with using a linear compressor. Figure 6 shows power consumption of a linear compressor in the refrigerator. Power consumption increases linearly Figure 6 Power consumption with ambient temperature Figure 7

2500, Page 6 Figure 8 Refrigerant mass flow rate Figure 9 Piston stroke with condensing temperature with increasing the ambient temperature from 15 C to 25 C. However, the power consumption increases sharply at 30 C of ambient temperature. This is because the saturated pressure of R600a is not linear function with the saturated temperature. Hence, the ratio of suction pressure to discharge pressure increases with increasing condensing temperature, causing high compression work. Figure 7 shows variation of a temperature at F-evaporator inlet and temperature difference between inlet and outlet of a F-evaporator during only F-operation. As shown in Figure 7, temperature difference of F-evaporator decreases with increasing the ambient temperature while inlet temperature of F-evaporator maintains almost constant temperature. Figure 8 shows the refrigerant mass flow rate measured at outlet of hot-line. As shown in Figure 8, the refrigerant mass flow rate increases with an increase of ambient temperature. This is because piston stroke increases according to an increase of ambient temperature. As described in chapter 2, piston stroke increases with a rise of ambient temperature. Figure 9 shows variation of piston stroke with change of condensing temperature in calorimeter tests for a linear compressor. The piston stroke increases with an increase of condensing temperatures, which means an increase of the cooling capacity of the compressor. 4.3 Effects of cooling capacity of a linear compressor. The cooling capacity of a linear compressor can change with variation of a piston stroke. The compressor should be operated with consideration for cooling loads such as ambient temperature, putting the foods and door opening. In this test, cooling time and power consumption of a linear compressor are measured with variation of cooling capacity of the compressor at ambient temperature of 25 and relative humidity of 60%. As shown in Figure 10, cooling times to reach setting temperature of -18 in freezer compartment with compressor cooling capacity of 100, 90, 80, 70, 60% are 73, 91, 105, 115 and 138min, respectively. Figure 11 shows the power consumption and on-time Figure 10 Temperature in F-compartment Figure 11 Power consumption and on-time ratio

2500, Page 7 Figure 12 Discharge temperatures with compressor capacity Figure 13 Cooling time with cooling load Figure 14 Total power consumption with cooling load ratio of a linear compressor. On-time ratio decreases with an increase of compressor cooling capacity and power consumption increase from 70% to 100%. However, power consumption at 60% cooling capacity is larger than that at 70% cooling capacity because cooling capacity of a linear compressor is not sufficient compare to the cooling load. Also, the power consumption of a compressor is sharply increased at 100% cooling capacity compared to 90%. Figure 12 shows discharge temperatures of a linear compressor with variation of compressor cooling capacity. The discharge temperature is sharply increased at 100% cooling capacity due to increasing compression work and friction loss and low efficiency of a compressor at full capacity. As shown in Figure 11, the power consumption of a linear compressor was reduced by 22.4% with 70% capacity compared to 100% but on-time ratio was increased by 12.8%. As shown in Figure 11, power consumption and on-time ratio are in trade-off relationship. Therefore, the refrigerator must be designed with consideration of this relationship between power consumption and on-time ratio. In the tests on effects of cooling capacity of a linear compressor, internal cooling load of 100W for 12min. is inputted by a heater installed in a R-compartment under the steady operating condition. Figure 13 and 14 show cooling time and total power consumption to remove the cooling load. As shown in Figure 13 and 14, total power consumption decreases with increase of compressor cooling capacity from 70% to 90%. However, the total power consumption at 100% increases while cooling time decreases. 5. CONCLUSIONS The experimental simulation of a refrigerator-freezer using a linear compressor is conducted with R600a. As results of the experimental simulation, the power consumption of a linear compressor is 41.7% and 31.1% lower than that of an inverter reciprocating compressor for cooling capacity of 70% and 100% of full capacity of both compressors.

2500, Page 8 The cooling capacity of a linear compressor increases with an increase of ambient temperature owing to an increase of piston stroke. Also, the power consumption can be reduced by controlling cooling capacity of a linear compressor. The power consumption and on-time ratio are in trade-off relationship. Therefore, a linear compressor should be operated with consideration for this relationship. NUMENCLATURE A p area of piston ( friction damping coefficient (Nm/s) gas damping coefficient (Nm/s) i current (A) average gas spring (N/m) gas spring constant (N/m) resonant spring constant (N/m) L inductance (mh) nth pressure in cylinder (Pa) discharge pressure (Pa) suction pressure (Pa) R resistance (Ω) V input voltage (V) piston s bottom position (m) initial displacement (m) piston s top position (m) α motor constant (N/A) ω angular velocity (rad/s) REFERENCES Kim, J. K., & Jeong, J. H.,(2013). Performance characteristics of a capacity modulated linear compressor for home refrigerators. Int. J. Refrig., 36, 776-785. Lee, H.K., Song, G.Y., Park, J. S. Hong, E. P., Jung, W. H. & Park, K. B., (2000), Development of the Linear Compressor for a Household Refrigerator, International Compressor Engineering Conference., paper. 1364. Chun, T.W., Ahn, J.R., Lee, H.H., Kim, H.G., Nho, E.C., (2008), A Novel Strategy of Efficiency Control for a Linear Compressor System Driven by a PWM Inverter., IEEE transaction on industrial electronics 55, 296-301. Kim, J.K., Roh, C. G., Kim, H., & Jeong, J. H., (2011), An experimental and numerical study on an inherent capacity modulated linear compressor for home refrigerators. Int. J. Refrig, 34, 1415-1423. M., Mohanraj, S., Jayaraj, C., Muraleedharan, P., Chandrasekar., (2009), Experimental investigation of R290/R600a mixture as an alternative to R134a in a domestic refrigerator. International Journal of Thermal Sciences 48, 1036-1042. B.O. Bolaji., (2010), Experimental study of R152a and R32 to replace R134a in a domestic refrigerator. Journal of Energy, 35, 3793-3798. ACKNOWLEDGEMENT This work was supported by the Human Resources Development program(no. 20144010200780 ) of the Korea Institute of Energy Technology Evaluation and Planning(KETEP) grant funded by the Korea government Ministry of Trade, Industry and Energy.