DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

Similar documents
DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

Direct reading flowmeters type RM

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

Level gauges Series LS Level indicator, switch and transmitter for liquids

Rotameter series 250 metal tube variable area flowmeter

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

RT FLOW RATE TOTALISER

BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13

Section B Field Instruments

Flow Measurement SITRANS F C

Rosemount 3100 Series Ultrasonic Level Transmitters

Ar-Mite TM Low Flow Armored Flowmeter

Inductive Conductivity

Technical Specification VFD

The A-series Eletta Flow Monitor with local indication and analog output

TR FLEXMAG 4050 C Electromagnetic flow meter for single use processes

MT3809G Series. Data Sheet. Metal Tube Variable Area Flowmeters. Overview. Product Description. Variable Area

BA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13

Rosemount 3100 Series Ultrasonic Level Transmitters

Enraf Servo Gauge 854 XTG

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology

Flow Level Pressure Temperature. Rugged tactile response keys. Try the all new Fluidwell Configurator at:

Rosemount 2090F Hygienic Pressure Transmitter

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

Dräger Polytron 8000 Stationary gas detector (EC)

DP86 Constant Voltage with Fitting

Model 144H. Product Data Sheet , Rev DB February Content

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

Centro-Matic Automated Lubrication Systems System Controls

VersaFlow Mag 2000 FL Electromagnetic Flow Sensor Technical Datasheet. Specification. Solution with high-tech ceramics. Highlights.

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

MagMaster MFE flowmeters feature an innovative multifrequency

Sitron s CF Line of Flow Switch Monitors

Software Version 2.01 LEVEL MONITOR MODEL 220

Rosemount 3051CFC Compact Flowmeter

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Sanitary Pressure Transmitter

SP-2400 & 2410 Series Smart Valve Positioner (Linear & Rotary)

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Model 144H. Product Data Sheet , Rev DB February Content

Ultrasonic Switches. Features & Benefits

Ultrasonic Point Level Switches

OEM Sensors for HVAC manufacturers Heat recovery Chiller

LC2200 Level Controller Installation and Maintenance Instructions

Enraf Servo Gauge 854 ATG

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

Rosemount 2088 Absolute and Gage Pressure Transmitter

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Gas cylinder scale Model GCS-1

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

SILO PROTECTION SYSTEMS

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

M7100 Pressure Transducer

Absolute and Gage Pressure Transmitter

Rosemount 4500 Hygienic Pressure Transmitter

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8720 IR Detection of carbon dioxide

1. Division 23 Section "Steam and Condensate Heating Piping" for steam and condensate meters.

Electronic Flow Switches

SPECIFICATIONS - DETAILED PROVISIONS Section Magnetic Flowmeters C O N T E N T S

ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Electronics based on Smart Meter Manager TM Technology

Dräger Polytron 5720 IR Toxic Gas Detection

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

HYGROPHIL H process hygrometer

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

Level Measurement Continuous level measurement Ultrasonic transmitters

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 5720 IR Detection of carbon dioxide

VersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet. Specification

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

ANEMOMETER 4403-RF-BAT

Dissolved Oxygen Analyzers

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

Ramsey Motion Monitoring Systems

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

FCHM Hydromatic Pump Control Module

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Fill Point, Level Gauges, and Control Range

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Using the Model 1500 Portable Chilled Mirror Hygrometer

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

M5800 Pressure Transducer with Rotatable Display

Temperature Solutions Line Card

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

Hazardous Area Zirconia Oxygen Systems

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Transcription:

UK / Europe Office Tel: +44 (0)8700 434040 Fax: +44 (0)8700 434045 info@omniinstruments.co.uk www.omniinstruments.co.uk Australia / Asia Pacific Office Tel +61 (0)282 442 363 Fax +61 (0)294 751 278 info@omniinstruments.com.au www.omniinstruments.com.au USA / Canada Office Tel +1-866-849-3441 Fax +1-866-628-8055 info@omniinstruments.net www.omniinstruments.net Instrumentation for fluids Flow measurement of Gases and Liquids Metallic construction. Operates horizontally or vertically DN-80 to DN-500 Flow rate: - Water: 1.5 m 3 /h up to 1600 m 3 /h. - Air: 45 Nm 3 /h up to 48,000 Nm 3 /h. Low Pressure drop. Straight pipe requirement of 3 x DN before & after. Available with: - Local Indicator - 1 or 2 Alarm Settings - 0/4-20 ma Transmitter with 2 or 4 wire system. - Flow integrator/totalizer. - 3-15 psi transmitter. Intrinsically safe version EEx ib II T5/T6 CENELEC Assembly connections: - Between flanges (wafer) for DN-80 to DN-300 - Standard Flanges for DN-250 to DN-500 Target Flowmeter Series DP-65 DP-500 Operation The fluid flows through the meter and displaces the target disc with a force proportional to flow. The disc movement is restricted with a coil spring until a force balance is achieved between the force from the fluid and the torsion of the spring. The equilibrium position of the target disc is proportional to the flow rate and provides the measurement of flow. The position of the disc is transferred to the flow indicator through a magnetic coupling. This indirect coupling protects the measurement from any impacts on the disc.

Applications The construction of the flowmeter is simple and robust. It is suitable for gases and liquids and provides a good measurement for fluids containing suspended mater. The DP-65 & 500 are used in many industries, including: - Water treatment & distribution. - Pharmaceutical industry. - General Chemical Industries. - Paper industry. - Heating and cooling circuits. - Swimming pools. - Fire protection systems. Flow Directions ED Technical Data DP-65 for pipe sizes from DN-80 to DN-300. DP-500 for pipe sizes from DN-250 to DN-500. Mounting Length: DES DP-65 DN-80..DN-300, Length = 65mm Installation between flanges (Flange not supplied) DP-500 DN-250..DN-300, Length = 500mm DN-350..DN-400, Length = 600mm DN-500, Length = 700mm Flange type DIN 2501 as standard. Accuracy: +2.5% of Full Scale. +1.5% of Full Scale (Special version). Scales: - Direct in engineering units or in % Temperature of fluid: -20 o C to +130 o C Steel/Polyamide 11-20 o C to +180 o C Steel -20 o C to +180 o C AISI-316 Special versions: -20 o C to +250 o C AISI-316-20 o C to +120 o C PTFE 0 o C to + 50 o C PVC Ambient temperature: -20 o C to + 80 o C Working pressure: PN-40 DN-80 PN-16 DN-100...DN-200 PN-10 DN-250...DN-500 DAB BD 2

Operation Vertical: Rising and falling flows. Horizontal: Flow from Left to Right and Right to Left. Indicator box: IP-65 in Polyamide 11 coated aluminium. Models DP-65 & DP-500 Body material: Steel coated in Polyamide 11. Disk, axis and spring in AISI-316. DP-65/SS & DP-500/SS All wetted parts in AISI-316. DP-65/PVC & DP-500/PVC. Body in PVC; disk, axis and spring lever in Hastelloy. DP-65/PTFE & DP-500/PTFE. Body in PTFE; disc, axis and spring lever in Hastelloy. DP-65 & DP-500/AMM alarm. DP-65 & DP-500/AMD (and relay WE77) DP-65 & DP-500/TEH with adjustable micro switch with inductive alarm, with 0...4-20 ma transmitter, (4 wire) DP-65 & DP-500/TOTH with flow totalizer. DP-65 & DP-500/TTEH volume totalizer + analog output DP-65 & DP-500/TK with 0...4-20 ma transmitter, (2 wire). DP-65 & DP-500/TKEX with 0...4-20 ma instrinsically safe transmitter. DP-65 & DP-500/1200 with pneumatic transmitter, (3-15 psi/0,2-1 bar). Metallic Target Flowmeter Series DP-65/DP-500 Materials Item Description DP-65 DP-65/SS 1 Mask/Scale Aluminium Aluminium 2 Indicator Aluminium Aluminium 3 Window Metracrylate Metracrylate 4 Screw AISI-316 AISI-316 5 Spacer Brass Brass 6 Bridge Aluminium Aluminium 7 Bearing housing Brass Brass 8 Axis AISI-316 AISI-316 9 Magnetic Brake Aluminium Aluminium 10 Disk Brake Aluminium Aluminium 11 Magnet housing Aluminium Aluminium 12 Magnet -Supernialco - 13 Ball Bearing AISI-316 AISI-316 14 Locking Piece AISI-316 AISI-316 15 Gasket Acrilo-nitrile Acrilo-Nitrite 16 Disk Spring AISI-316 AISI-316 17 Stop pin AISI-316 AISI-316 18 Spring AISI-316 AISI-316 19 End bush PTFE PTFE 20 Axis AISI-316 AISI-316 21 Disk AISI-316 AISI-316 22 Body Steel AISI-316 23 Coating Polyamide 11 24 Lid Aluminium Aluminium 25 Enclosure Aluminium Aluminium 26 Washer Nylon Nylon 3

Series DP-65/DN-80 to DN-300 DN Standard Flow Rates Dimensions & Weight m 3 /h Water 20 o C g B A Wt (Kg) 80 2-16 3-25 5-40 138 50 245 8 100 5-40 8-60 10-80 158 60 245 10 125 8-60 15-100 15-120 188 70 275 12 150 15-100 20-160 25-200 212 78 275 14 200 20-160 30-250 40-350 268 90 315 20 250 25-200 50-400 60-500 320 102 345 29 300 30-250 50-400 80-600 370 115 363 35 Equivalent scale in Nm 3 /h Air @ 20 o C & 1.013 mbar Abs. = Water m 3 /h x Factor of 30. 4

Series DP-500/DN-250 to DN-500 DN Standard Flow Rates Dimensions & Weights m 3 /h Water 20 o C L A B D K g B 1xn o Wt (Kg) 250 25-200 50-400 60-500 500 325 90 395 350 320 26 23x12 70 300 30-250 50-400 80-600 500 325 115 445 400 370 26 23x12 78 350 40-300 60-500 100-800 600 345 124 505 460 430 26 23x16 86 400 50-400 80-600 120-1000 600 345 142 565 515 482 26 27x16 97 500 80-600 120-1000 200-1600 700 425 160 670 620 585 28 27x20 115 Equivalent scale in Nm 3 /h Air @ 20 o C & 1.013m Bar Abs = Water m 3 /h x Factor of 30. 5

Alarm Options Adjustable Micro Alarm, Series DP-AMM Micro-switch bi-stable contact mounted in the indicator enclosure of the flow meter. DP-AMM1: 1 adjustable alarm contact. DP-AMM2: 2 adjustable alarm contacts. Load: 3 Amp @ 220Vac/50Hz. Temperature: -25 o C to +80 o C. Hysteresis: + 10% of full scale. Mechanical life: 20 x 10 6 Operations. Contact speed: 0.01 to 1 msec. Adjustable Inductive Alarm, Series DP-AMD Inductive proximity sensor, 3.5 mm, according to standard NAMUR DIN 19234, mounted in the indicator enclosure of the flow meter. SC-AMD1...2: 1... 2 adjustable alarm contacts. (+ amplifier WE77/Ex1 or ExEx2). Power Supply: 8 Vdc. Temperature: -25 o C to +70 o C. Relay for Inductive Proximity Sensor Model WE77/EX 1: Model WE77/EX 2: For 1 inductive alarm contact. For 2 inductive alarm contacts. Power Supply: 220Vac +15%, 50-60Hz. (other ac & dc voltages are also available) Intrinsic Safety Standard: EEx ia II C (Zone 0) Output: for 1 or 2 contacts. Load: 4 Amp @ 220Vac/250VA Temperature: -25 to +70 o C. 6

Transmitters Electric Transmitter DP-TK-Ex The electric transmitter TK-Ex is a two wire angular position converter. It provides a 4-20 ma output signal directly proportional to the measured flow rate. Certified intrinsically safe to Cenelec EExibIIC T5/T6. Power supply: Load: Output signal: Electrical connection: 12.7 to 36Vdc 4mA + Output current 4-20 ma 2 wire Internal capacitance: Cp <15F Ambient temperature: EEx ib CT4 70 o C Max. CT5 65 o C Max. CT6 50 o C Max. Electric Transmitter DP-TEH Halltec Transducer based on a half effect pickup with zero friction on the indicating mechanism. Output signal directly proportional to the measured flow rate. Accurancy: 1,5% of the reading value Analog output available: 0...4-20 ma 0-5v, 0-10v, 1-5v, 2-10v Power supplies: 24, 110, 220, 240 Vac, 50/60 Hz 24 Vdc Powerconsumption: < 3 w Ambient Temperature: -10 to +60 o C Electric conection: 4 wires Pneumatic Transmitter DP-TP1200 The pneumatic transmitter DP-TP1200 provides a 3-15 psi or 0.2-1Bar pneumatic signal directly proportional to the measured flow rate. Air supply: Consumption: Output signal: Air 1.4 Bar + 0.1 Bar 460 Nl/h Air 3-15 psi (0.2-1Bar on request) Linearity: + 0.4% Hysteresis: + 0.25% Temperature: -10 o C to +70 o C 7

Totalizers Halltec Transducer DP-TOTH/DP-TTEH Based on a Hall effect pickup with zero friction on the indicating mechanism. Totalizer DP-TOTH/DP-TTEH The output signal 4-20 ma (or 0-20 ma) from the transmitters can be connected to an electronic counter either built into the indicator enclosure or mounted remotely. DP-TOTH (Volume Totalizer) Electronic LCD counter 8 digits with reset. Digit height: 8 mm Accurancy: 1,5% of the reading value Pulse Output: TTL & open collector DP-TTEH (Volume Totalizer + Analog Output) Electronic LCD counter 8 digits with reset. Digit height: 8 mm Accurancy: 1,5% of the reading value Analog Output Available: 0...4-20 ma 0-5v, 0-10v, 1-5v, 2-10v Pulse output: TTL & open collector General Characteristics: Power Supplies: 24, 110, 220, 240 vac, 50/6 DH2 24 Vdc Power Consumption: < 3w Ambient Temperature: -10 o C to + 60 o C We are at your service, please consult us. TECFLUID develops and manufactures instruments for gases and liquids, using the most advanced techniques. FLOWMETERS - Variable area with Glass metering tubes. - Variable area with Metal metering tubes, and indication via magnetic transmision. - Target disk and indication via magnetic transmission. - Orifice disk. - Electromagnetic. In preparation: - VORTEK COUNTERS - COVOL (Oscillating piston) - TM-44 (Turbine) LEVELS - Limit switches - Indicators - Transmitters ELECTRONIC EQUIPMENT - Converters - Batching Counters - Flow rate indicators - Transmitters UK / Europe Office Tel: +44 (0)8700 434040 Fax: +44 (0)8700 434045 info@omniinstruments.co.uk www.omniinstruments.co.uk Australia / Asia Pacific Office Tel +61 (0)282 442 363 Fax +61 (0)294 751 278 info@omniinstruments.com.au www.omniinstruments.com.au USA / Canada Office Tel +1-866-849-3441 Fax +1-866-628-8055 info@omniinstruments.net www.omniinstruments.net