TRACENET TM TN SERIES

Similar documents
TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

CONTROL AND MONITORIN

TraceNet TM TCM2 CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

RAYCHEM NGC-30 COMPONENTS

TraceNet ECM Series Control System

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

NGC-40 Advanced Heat-Tracing Control System

ACCS-30. Multipoint commercial heat-tracing control system

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

HTC-915-CONT. Heat-Trace Control system

TRACENET TM GENESIS. Installation, Operation & Maintenance Guide CONTROL AND MONITORING SYSTEM

920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS).

APPLICATION DATA SHEET

Heating Cable. Description

DigiTrace NGC-family

Process Alarm Solutions

SUPREMATouch. Modular Fire & Gas Detection System

ITAS / ITAS-EXT / ITLS / ITLS-EXT

SUPREMATouch. Modular Fire & Gas Detection System

Industrial Grade Gas Detection Detecting The Difference

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

GasGard 100 Control System

910 Series Single-point heat-tracing control system

Dual-point heat-tracing control system

APPLICATION DATA SHEET

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

API MARINE BMS4 REMOTE SOUNDING SYSTEM FOR BALLAST AND SERVICE TANKS

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

For Complete Fire and Gas Solutions

Arc Fault Protection System D1000

/8 DIN Level Indicator

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

D1000 Arc-fault Protection System

C910 Series. Single-point heat-tracing control system

Fire and Gas Monitoring Panel ST7-HV

IntesisBox BACnet/IP Server - Notifier ID3000 series

Intelligent addressable fire alarm control panel

Temperature Controllers

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

TraceNet TC Series Control System

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

NGC-20 LOCAL CONTROL CENTRAL MONITORING

Y-Plant Alert. Alarm Annunciator and Sequence of Event Recording System. BU 04M01A02-01E-A

Touchpoint Pro Flexible Gas Control System

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

AmpLight group management

AmpLight Lighting Management System

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

Heating Cable. Description

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM

VTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL

Nov 08 PRODUCT SPECIFICATION SHEET

Temperature Solutions Line Card

EC-BOS-602/616 AX Security

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Annunciation, Remote Monitoring, Control Industrial Control Panels

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

ITC 1 & 2 Circuit Heat Trace Controller Line or Ambient Sensing

UDC 700 Universal Digital Controllers and Indicator Specifications

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

When reliability is vital. Alemite Carbon Shield TM Systems deliver

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Temperature Control Systems

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

PLSRR Heat Trace Cable Data Sheet

ITC 1 & 2 Circuit Heat Trace Controller Line or Ambient Sensing

Ronan Model X90 Series Point Level Monitor

X11CA COMPUTER ANNUNCIATORS

Sintrol Snifter A2 EX. Manual. Version 1.2.3

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Specification for On-Line UPS Battery Monitoring and Data Management System

Across-the-Line SERIES MP300 Combined Manual and Automatic

OPENING AN ENCLOSURE and blowing a fan on heat sensitive components

IGD.CO.UK

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Gas Controller Module GC-06

RADIOLOGICAL SURVEILLANCE & ALARM MANAGEMENT SYSTEMS

Process & TeMPerATUre UniversAl input DigiTAl MeTers

I/A Series 716C 1/16 DIN Temperature Controller

LORAIN CIP 4890/48120 DC Power System

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

- Data Brochure Universal Reset Module 422

Transcription:

TRACENET TM TN SERIES CONTROL AND MONITORING SYSTEM INTRODUCTION Heat trace has become increasingly important for efficient and reliable operation of industrial process plants. This is true for both freeze protection (winterization) systems and those maintaining higher process temperatures. Process specifications call for increased heat tracing surveillance with high reliability, increased safety, more efficient energy management and lower operating costs. ENVIRONMENTALLY TOUGH The world s appetite for oil and gas continues to grow, and there are challenges for systems to operate in harsh arctic environments. Likewise, the demands on electrical heat trace controls and monitoring systems for refineries and chemical plants in harsh desert climates are increasing. TraceNet systems are proven to operate in ambient temperatures as low as -40 C or as high as +60 C. THERMON S SOLUTION The NEW TraceNet system is an extension of the proven Thermon TC101, TC202, and TC1818 control and monitoring systems. TraceNet introduces modular construction that provides: REDUCED FIELD WIRING To reduce field wiring, RTD Sensors can be multiplexed via CAN bus back to a central panel. Repeaters can be located in the "RTD POD" to extend the ranges beyond the standard 300 m. Remote "RTD POD s" can be employed to maximize multiple RTD sensors. LOWER TOTAL COSTS For some companies the issue is design simplicity; for others lower installation costs. Owners continue to call for preventive maintenance to reduce downtime, provide efficient energy management, and lower operating costs. TraceNet accomplishes all of these objectives! Design Versatility Reduced Assembly Times Reduced Fabrication Cost Easy Expansion for the Future. Resistance to Vibration and Shock 1

WITH OVER 50 YEARS OF EXPERIENCE THERMON HAS THE SOLUTION FOR YOUR HEAT TRACING NEEDS CONTROL TraceNet allows each six-circuit control module to operate independently and provides several different control options: On/Off Control On/Off Control with Soft Start Proportional Control and/or APC (Ambient Proportional Control) LOAD SHED TraceNet systems provide load shedding to reduce facility energy consumption with one of five different priority levels assigned for each controlled heat trace circuit. TraceNet load shed functions can be scheduled routinely during periods of peak energy demand or can be manually activated on an event-by-event basis. TraceNet controls up to 180 circuits operating from 100 to 600 Vac MONITORING Low & High Temperature Alarms (including independent high temp trip function) Up to 6 RTD sensors per heat trace circuit Low & High Heater Current Alarms (with high current trip function), and High Ground / Earth Leakage Current Alarm (with separate trip function) Up to 6 RTD sensors per heater or 540 sensors from a single TraceNet touch screen monitor. Reduced Energy Consumption = Lower Operating Costs Electrical heat trace is designed based on heat losses during the coldest ambient conditions expected. In some cases this may represent miles of pipe in an arctic environment requiring several hundred kilowatts of electrical power. Conventional ambient control uses one or two sensors to energize contactors for all connected heat trace Ambient Proportional Control (APC) whenever ambient temperatures fall to the thermostat set-point. This commonly accepted method of control delivers at or nearly 100% of the total heating capacity, even if it s only a few degrees below the control set point. Ambient Proportional Control (APC) provides the logic to deliver 100% of the power only at the lowest possible ambient temperature. Realistically this might only occur once every few years. At other times the power delivery is proportional to the actual ambient temperature, thereby reducing the average energy consumed. 100% Power Delivery at the Coldest Ambient Ambient Proportional Control (APC) reduces operating costs up to 50% when compared to conventional ambient control. Power 0% T a-min Ambient Savings T p 20%* Higher process temperatures can also be controlled with APC with reasonable accuracy. This approach may not reduce operating cost, but it significantly reduces the number of temperature sensors and control circuits. T p = Pipe Maintain Temperature T a-min = Minimum Ambient Temperature * Note: No less than 20% power delivery when energized to maintain electrical current monitoring functions. Ambient Proportional Control (APC) lowers installed costs when compared to line sensing control for each process flow path. THERMON The Heat Tracing Specialists 2

3 Phase Power S TRACENET TM TN SERIES CONTROL AND MONITORING SYSTEM COMMUNICATIONS Ethernet Direct to DCS Modbus RTU Ordinary (Non-Hazardous) Area TRACEVIEW NETWORK EXPLORER (HOST PC) Heat Trace Panels With or Without Power Distribution and/or Control Relays (in MCC) TSM 1 Touch Screen Ambient Sensing RTD RTD Leads CAN Bus Heat Trace Circuits 3

TRACENET REMOTE "RTD-PODS" - REDUCE INSTALLA- TION COSTS: Can multiplex up to thirty-six RTD sensors to two-wire CAN bus for distances up to 300 m. Distance can be extended via CAN for greater distances where required. CAN Interface Module: CIM1 isolates CAN network and extends the network link. Temperature Sensor Module: TM6 module for up to six (6) RTD sensors per heat trace circuit for additional monitoring points. Power Supply: 24 Vdc, input from 100-240 Vac. TraceNet RTD Pod Hazardous (Classified) Area 1. Multiple RTD Heater 2. Ambient Proportional Control (APC) 3. Line Sensed Circuit Control (1 RTD per Ckt) APC TRACENET SUPPORTS ALL RTD TEMPERATURE SENSOR CONFIGURATIONS 1. Up to six (6) RTD s per Heater 2. APC (Ambient Proportional Control) Eliminates Sensors and Reduces Cost. * 3. Conventional Process Control with a Dedicated RTD Sensor per Heater * APC reduces operating cost on average of 50% over conventional ambient sensing control. Alternately APC reduces installed costs for process maintenance systems when compared to line-sensing control. Heat Trace Circuit Voltage Supply TraceNet RTD Pod upply Hazardous Rated Distribution / Switching Panel Heat Trace Control Area Network (CAN) (Connects Modules for Scanning Rates up to 125kB / Second) THERMON The Heat Tracing Specialists 4

TRACENET TM TN SERIES CONTROL AND MONITORING SYSTEM TRACENET COMPONENT CONFIGURATION The new TraceNet system offers design simplicity and versatility. The components have been designed for easy installation, maintenance, and system expansion over the life of each installation. The various modules described below are connected by CAN (Control Area Network) and can be separated by significant distances. Approved for installation in most every environment, TraceNet modules can be located in a control room, a motor control center (MCC), or in an industrial process unit. Touch Screen TSM1 User Interface and Communications Module The touch screen interface for data entry or information retrieval is simple to use. Three (3) USB ports are provided to quickly import/export large amounts of data, change control configurations, connect to a notebook PC, remote mouse or pointer device. Heater Control Power Modules Optimize switching life and current ratings with nonarcing solid state relays mounted on external heat sinks. Internal heat sinks, hybrid mechanical relays and sealed mechanical relays are also available. (Each PM6 includes six 1 or 2-pole relays, and also provides self-test for earth-leakage current.) RTD to CANBUS connections DIN rail mounted RTB6 for (6) RTD terminations Control Module Each PCM6 control module independently controls up to six (6) heaters, and can be either DIN-rail (PCM6DR) or rack mounted (PDM6RM). Temperature Sensor Module TM6 module for up to six (6) RTD sensors, and can be either DIN-rail (TM6DR) or rack mounted (TM6RM). (Note: The PCM6 and TM6 Modules shown here are rack mounted in the BPM Back Plane Module.) Power Supply Provides 24 Vdc from 100-240 Vac supply voltage. Power Distribution All power distribution designs are compatible with TraceNet control and monitoring systems for electrical heat trace. Sealed breakers can be installed in IP65 or NEMA 4/4X cabinets for hazardous (classified) area installations. Alternatively, standard open frame main and branch breakers can be installed in IP65 or NEMA 4/4X cabinets with purge for hazardous (classified) areas. 5

OPERATOR ACCESS The TraceNet touch-screen monitor can be located almost anywhere to serve as the interface and central communications point for multiple systems. The operator can view real time temperature and current conditions and access control & monitoring set-points throughout the CAN Control Area Network. Up to (180) heat trace circuits can be accessed from a single TraceNet touch screen monitor. (TSM1 shown at right.) ACCESS IN YOUR LANGUAGE The Windows CE operating system provides for user-selected languages whenever entering data or monitoring of heat trace circuits. Almost every language can be supported. TSM1 Touch Screen Monitor REMOTE COMMUNICATIONS The TraceNet TSM1 supports communications via Ethernet directly to a DCS via Modbus RTU protocol and to a PC with TraceView Network Explorer (TVNE) installed. TVNE can interface with TraceNet and other Thermon TC controllers (i.e. TC101,TC202, and TC1818 units) through different communicationschannel(s). In this way, existing plant RS 485 data highway networks are integrated seamlessly with the new TraceNet networks forming a unified and integrated supervisory control and data acquisition system (SCADA). THERMON The Heat Tracing Specialists 6

Corporate Headquarters 100 Thermon Dr. PO Box 609 San Marcos, TX 78667-0609 USAPhone: +1 512-396-5801 Form TEP0116-0314 Thermon Manufacturing Co. Printed in U.S.A. Information subject to change.