for Drinking Water Systems

Similar documents
WASTEWATER Online UV%Transmission Analyzer

Turbimax CUE21 / CUE22

Turbimax CUE21 / CUE22

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

CLARITY II TURBIDIMETER

Series 5000 Hydrazine Analyzer Model 60002

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

HYDROSENSE 3420 On-line Oil in Water Monitor. User Manual

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

AS950 PORTABLE SAMPLERS

COBRIX3 multibev. Online Beverage Analyzer. ::: Unique Density & Concentration Meters

AS950 REFRIGERATED SAMPLERS

MICRO 200 BW TURBIDIMETER RANGE OPTION NTU

Hydrazine Analyzer Series 2171 Specifications

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

OWNERS MANUAL. HF Oil Content Monitor (OCM)

OWNER S MANUAL CLX OnLine Residual Chlorine Monitor

OMA-300 Process Analyzer

Tri-Tech Medical Inc.

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Inductive Conductivity

Temperature Controllers

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

SIL 2. Ultima X Series Gas Monitors CERTIFIED

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Turbimax CUE21 / CUE22

Mark 25 Ultrapure Water Conductivity Analyzer

Signet 4150 Turbidimeter

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Specifications Wavelength Range: 190 nm to 800 nm continuous

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

HF Series R_RevB

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

Low Temperature Zirconia Oxygen Analyzer

SAMPLE MANUAL - INSTALLATION - FOR REFERENCE ONLY. ChemScan mini Analyzer. Parameter. Method #### Installation, Operation & Maintenance Manual

Freeze Dry Systems and Accessories

Guide Specification - MasterFormat 2017 Style SECTION FLOW INSTRUMENTS PART 2 PRODUCTS 2.1 SECTION INCLUDES 2.2 ACCEPTABLE MANUFACTURERS

APPLIED. OMA-406R Rackmount Process Analyzer

Med Touch Master Alarm

Signet 4150 Turbidimeter

Process Alarm Module RTA 421

I/A Series 716C 1/16 DIN Temperature Controller

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

UDC 700 Universal Digital Controllers and Indicator Specifications

SECTION Fluorescent Dissolved Oxygen Measuring System

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Altman Lighting Spectra Cyc UV 50 Specification

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Med Touch Combination Alarm Conversion Kits

PSA Series. Particle Size Analyzer

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Silica, Phosphate, Hydrazine Analyzers Series 2140 Specifications

When reliability is vital. Alemite Carbon Shield TM Systems deliver

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

VIQUA is an ISO9001:2008 registered company specializing in the design, manufacture and sale of ultraviolet systems for:

Freeze Dry Systems and Accessories

EZT Series Integra Med Touch Area Alarm & Zone Valve Box with EZ Backfeed

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

Technical Information OUSAF44

Integrated Process Solutions. Series 49. Thermal Management System

WEDECO Quadron UV System

Allure EC-Smart-Air Series Communicating sensors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Free Chlorine Measuring System

COA-2010-F Electronic CO 2

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

Multiview Monitor / Controller

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Ultraviolet (UV) Monitoring System - Open Channel Horizontal Systems Operation and Maintenance Manual

Ronan Model X96S Series Density System

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

continuous emissions monitoring Combustion & Environmental Monitoring

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

SERIES IN-2000 SINGLE AND MULTI-CHANNEL GASEOUS OZONE ANALYZERS

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Zircomat Oxygen Analyzers

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Model D12-IR. Digital Gas Transmitter...

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

Infrared Moisture Balance (FD-800)

A measured step forward

Transcription:

Water Quality Measurement Solutions Instrument Overview Online UV%Transmission Analyzer for Drinking Water Systems HF scientific developed the AccUView UV%Transmission Analyzer specif ically to f ill the need for increased drinking water UV disinfection monitoring. The AccUView is manufactured using microprocessor technology making it the most reliable and cost eff icient instrument for monitoring the % transmission of drinking water UV disinfection systems. The Auto Clean Ultrasonic Cleaning System continuously cleans the optical chamber to reduce operator maintenance time. Detailed Specifications Standard Features Range of 0-100% Transmission (Auto Ranging) Ultrasonic cleaning continuously cleans the sample cell ensuring accurate and reliable readings Fast response time and inexpensive calibration due to low ( 30 ml ) sample volume. Modular design reduces overall costs. Removeable sample cuvettes allow for easy cleaning and calibrating. 4-20 ma output or Optional RS-485 with Modbus protocol. Patent Pending Design

OnLine UV%Transmission Analyzer Features Optical Design New optical design allows consistant readings with laboratory %T analyzers. Bubble Rejection System The optical chamber has been designed to eliminate air in the sample while simultaneously creating a vortex cleaning action throughout the optical chamber. Certified Traceable Standards HF scientif ic inc. certif ies the 100%T Calibration Standard is prepared as outlined in Standard Methods for the Examination of Water and Wastewater, 20th Edition, Method 1080 A-C, Methods for Preparation of Reagent Water. New Design One-piece mounted design allows for simple mounting and minimal use of space. New optical design increases accuracy and provides more consistent readings with online and laboratory %T Analyzers. Response Time Adjustable response times allow User to program readings to be taken between 4 to 60 seconds. Backlight Display User adjustable Backlight Display allows viewing in low light conditions. Certification Listed or Certif ied to CE, UL, CSA (ETL,ETLc) Sample Specifications The continuous monitoring system shall include a single modular unit with power supply, display and sensor as one single mounted unit. The %T Analyzer shall have consistent readings with laboratory %T Analyzers. The %T Analyzer shall be Modbus compatible and have a full time automatic ultrasonic cleaning system for f inished or raw water applications. Resolution will be 0.1 %T. Repeatability shall be plus or minus 0.1%. The sensor shall consist of a rotational flow through assembly with a 30ml cuvette. The specially designed flow head bubble rejection system eliminates the need for a bubble trap and ensures an immediate response time. The sensor shall be able to accommodate grab samples. Calibration and standardization will be accomplished using a small volume (30ml) cuvette. The lamp source and detector shall not come in contact with the sample. The %T Analyzer shall use menu driven software for ease of use. The %T Analyzer enclosure shall be NEMA 4X (IP66). The OnLine %T Analyzer shall be HF scientif ic AccUView OnLine %T Analyzer. Ultrasonic Cleaning System Keeps the optical chamber clean in f inished or raw water applications. 22

Specifications for OnLineUV%T Analyzer Range 0-100% Transmission Repeatability ± 0.1% T Resolution 0.1% T Accuracy ± 1.0 % T Wavelength Ultraviolet 253.7nm Response Time User Selectable Updates from 4-60 seconds Pressure/Flow Rate Maximum 200 psi/1000ml per minute Built in Regulation Provided Standard Outputs 4-20 ma with isolator Optional Output RS-485 with Modbus Protocol User Alarms 2 User Selectable High / Low Alarms Calibration * 100% T Standard Certif ied Display Multiline Custom LCD with Backlight Security Code Prevents unauthorized access Built in Diagnostics Yes Storage Temperature -4 F to 140 F (-20 C to 60 C) Operating Temperature 0-50 C (32 to 122 F) Wetted Surfaces Nylon, Quartz, Silicon, Polypropylene, Stainless Steel Enclosure NEMA 4X, IP66 Outdoor Installation 32 F to 122 F (0 C to 50 C) (Protective Enclosure Required) Certif ications CE, ETL (UL), ETLC (CSA) Dimensions 14 " x 12" x 12" ( 35 cm x 30 cm x 30 cm ) Shipping Weight 2.72 kg ( 6 lbs. ) Electrical 90-250 Volts, 50/60 CPS, 80VA Specifications subject to change without notice. *ASTM, 20th Edition, method 1080 A-C Ordering Information Catalog No. Description 19577 AccUView OnLine UV%Transmission Analyzer, 100-240 VAC, 50/60 CPS Accessories 24232S Quartz Cuvette with Ultrasonic Transducer 19609 Remote Display for an additional digital readout up to 500 feet away 19323 Primary Calibration Standard, 100%T, NIST Traceable 500mL 70908 Primary Calibration Standard, 100%T, NIST Traceable 1 gallon 19851A RS-485 output with Modbus Protocol (factory installed option) 3

Dimensions for All Dimensions are in Millimeters (inches). OnLine UV%T Analyzer Provide at least 200 MM (8 inches) of free space above the sensor for easy removal of the flow head and insertion of the calibration standards. 207.65 (8.175) 90.17 (3.550) 50.80 (2.000) These 2 holes will accept up to 4.5 MM (3/16 inch) hardware. (Holes are inside case) 87.33 (3.438) Inside of Case 30.17 147.66 (1.188) (5.813) 131.16 (5.164) These 4 holes will accept up to 7 MM (1/4 inch) hardware 347.16 (13.668) 61.77 (2.432) 196.85 (7.750) 44

Dimensions for Shutoff Clamp allows for shutoff of the intake flow during cuvette cleanings and replacements. OnLine UV%T Analyzer Backpressure Valve allows adjustment of the amount of back pressure, which will help to control flow rate and eliminate small bubbles. Inline Pressure Regulator Max. Input 1380 kpa (200psi) Factory set to 103.5 kpa (15 psi) Intake Tubing Connection 4.75 mm (3/16 inch) I.D., 8 mm (5/16 inch) O.D. tubing should be connected here to supply the sensor with a dependable sample flow. 3170 Metro Parkway Ft. Myers, FL 33916-7597 Phone: (239) 337-2116 Fax: (239) 332-7643 Email: hfinfo@watts.com www.hfscientific.com Drain Tubing Connection 4.75 mm (3/16 inch) I.D., 8 mm (5/16 inch) O.D. tubing should be connected here to route the sensor drain tubing to a suitable site drain. SOLTECH Ltda. Calle 76 No. 20B - 24 Of. 302. Bogotá D.C. Tel: +1-347 5141. Fax: +1-347 5170. E-mail: infotecnica@soltechltda.com www.soltechltda.com 3170 Metro Parkway, Ft. Myers FL 33916 Phone: (239) 337-2116 Fax: (239) 332-7643 Revised 07/02/08 5