INSTALLATION AND CARE INSTRUCTIONS

Similar documents
INSTALLATION AND CARE INSTRUCTIONS

INSTALLATION AND CARE INSTRUCTIONS

1. Description - THIS UNIT IS FOR DOMESTIC USE ONLY

Sanipack is a compact pump/macerator specially designed to take the waste from a wall hung or back to wall WC pan.

1. Description. 2. List of Accessories included

Please also see 10 golden rules for correct Saniflo installation on

Smarter. Easier. Faster. Product Guide

Intelligent plumbing solutions that allow you to add the luxury of extra facilities almost anywhere you choose. Smarter. Easier. Faster.

WC2 & WC3 Installation & Maintenance Instructions

Smarter. Easier. Faster. Product Guide

Greenleaf 600 Macerator Toilet Waste Pump

Greenleaf 400 Macerator Toilet Waste Pump Instruction Manual

USA CDN. SANIMARIN Macerator Toilet Owner s Manual SANIMARIN 31C SANIMARIN 35 SANIMARIN 48

Quartz. Thermo. Concealed shower valve with adjustable head. Quartz Thermo installation guide page 1

HW3 Handwash Installation and Operating Instructions

2. Sanitary Plumbing General Installation Requirements

Macerator Pumps & Lifting Station. Technical presentation Part 1

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

DOMESTIC & COMMERCIAL PLUMBING SYSTEMS FURTHER INFOMATION

POWER SHOWERS Models 4500M 5002M 4500T 5002T

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

The Collection Chamber

SOLOLIFT2. Grundfos bring you a macerator that is the most powerful, reliable and service friendly on the market, delivered by a name you can trust

STUDENT NOTES Plan, size and layout sanitary pipe work and fixtures

NEWS 2017 SANIFLO. Pumps and pumping stations

Issue 4 Oct Panamatic Top loading Maxi & Optima 3 Installation

INSTANTANEOUS ELECTRIC SHOWER

Cinnamon Kitchen Sink Tap

Monza Easyfit Kitchen Sink Mixer

GUH52SD 52 cm GUH75 75 cm Canopy Hood

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

Add the luxury of extra facilities almost anywhere you choose

TH100 Three in One Instant Hot Water Tap

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Blueberry Kitchen Sink Tap

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

BATHROOM FURNITURE FITTING GUIDE

Silent Venus SVP100. **Visit for how to install instruction videos**

Pear Kitchen Sink Tap

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

Oblo Basin and Bidet Monobloc Installation and User Guide

HOME INSPECTION CHECKLIST

Dove Eco thermostatic bar mixer shower

Aquamixa. Thermo. Thermostatic shower valve with manual bath fill

Aqua & Instantaneous Electric Shower Installation Instructions SERVICE POLICY

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 11: Sanitary Appliances Phase 2

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

The new SOLOLIFT2 means goodbye to dirty hands

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions

60cm Chimney Extractor

VADA - Rain2Main Automatic Rainwater Controller

INSTALLATION MANUAL GUTHD2. Universal Two Way Digital Thermostatic Valve for Shower Systems

REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER ANSWER SCHEDULE

GRUNDFOS SOLOLIFT2 GRUNDFOS SOLOLIFT2 ENGINEERED BY THE WORLD S LEADING PUMP COMPANY FOR PERFORMANCE, RELIABILITY AND EASY FITTING FROM THE OUTSET.

Singulier Spout Tube Basin Mixer Installation and User Guide

INSTALLATION INSTRUCTIONS

Sanitary Drainage Systems

Thermostatic bar mixer valve with adjustable head Installation guide

air pump 2700/4500 ? 2YEAR GUARANTEE UK AIRPUMP _33435 CASC /10/ :16 Page 1

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

REMOTE COOLER AIR COOLED & WATER COOLED

Decade Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

FREELANCE ORDERING INFORMATION NOTES T01-D

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT

PRESSURE SEWER SYSTEMS GUIDE FOR HOME OWNERS AND BUILDERS

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

Lucci Designer Hi Flow Exhaust Fan

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

Panamatic. Midi & Mini. Installation instructions.

Installation and User Instructions

NON-SUBMERSIBLE WATER PUMP

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Distinction. D4000 & D4000/EURO Water Still. Assembly and Operating Instructions. 1 Issue 2

Installation Instructions

8707T Includes seat. 8745T Includes Bowl

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

INTA ION MODERN BAR / BATH SHOWER MIXER CP

Manual and Thermostatic Power Shower Units

INSTRUCTION MANUAL (English version) Water still

ART cm Island Curved Glass

Thermostatic Shower Tower Installation and Operating Instructions

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

PLUMBING INSTALLATIONS

INSTALLATION INSTRUCTIONS

FRANKE MINERVA 3-IN-1 HOT WATER TAP HEATING TANK INSTALLATION GUIDE

SAFETY AND OPERATING MANUAL

HS&S Alert No: 103 Date: 9 March 2017

Ambassador. Installation guide & user instructions. Please ensure that this document is handed to the user after installation is completed

Flue Installation Manual

ODEON BEFORE YOU BEGIN ORDERING INFORMATION T01-C , 2006 Copyright Kohler China Ltd.,

Installation & Operating Guide

Zip Econoboil 1.5 litre White Zip Econoboil 3.0 litre White Zip Econoboil 5.0 litre White Zip Econoboil 7.

INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS BG 2000-S (V13) RU PL DE IT ES NL EN 1 662Y0600 A

100cm Chimney Hood GB IE

Installation guide Sahara & Sahara Plus

SHOWER PUMPS. Installation Manual. 1.5 bar and 2.0 bar

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

INSTALLATION INSTRUCTIONS

Manual / Handbuch Spare parts list / Ersatzteilliste

Transcription:

INSTALLATION AND CARE INSTRUCTIONS THESE INSTRUCTIONS MUST E READ EFORE INSTALLATION IS ATTEMPTED. FAILURE TO DO SO MAY COMPROMISE WARRANTY. FOLLOWING INSTALLATION PLEASE LEAvE ALL PAPERWORK WITH CLIENT AS IT CONTAINS IMPORTANT INFORMATION ON HOW TO UNDERTAKE ONGOING CARE FOR YOUR SANIPLUS PUMP TOGETHER WITH WARRANTY PAPERS. 1. Description - THIS UNIT IS FOR DOMESTIC USE ONLY The Saniplus is a compact macerator pump designed to receive and pump away sewage waste and water from one standard P-trap WC pan, shower, vanity, a bidet and bath. The Saniplus will activate automatically following the flush of your WC or inflow from either of vanity fixtures attached. Please pay particular attention to the following: Possible danger to personnel Warning of possible electrical hazard ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit. This pump benefits from the latest technological innovations concerning soundproofing. To benefit fully from the advantages provided by this new generation of appliances, it is important to comply with the installation instructions in section 5, 6 and 7. 2. List of Accessories included A x4 C D Discharge elbow Hose clip 32 x 55 Hose clip 25 x 40 Hose clip 20 x 32 E F G x2 H x4 Smaller diameter towards pump casing 100mm 90 x 110 Inlet Connector Hose clip Floor mounting bracket Foam feet I J Smaller diameter towards pump casing lanking off inlet cap Pan Collar and Cable Tie SANIPLUS PAGE 1

3. Dimensions and overall measurements 40 180 4. Performance curve USE ONLY Ø 20MM PRESSURE PIPE FOR vertical LIFT 6 HEIGHT (m) 4 2 0 0 10 20 30 40 50 60 70 80 90 100 110 OUTPUT (litres/min) 5. vertical and horizontal pumping parameters All elbows must be 2 x 45 5m max 4m 3m 1:100 2m 1m All horizontal pipework requires a minimum of 1:100 fall Install Isolation Valve at beginning of pipe run 10 20 40 60 80 100 metres Following vertical lift, increase discharge pipe diameter by one size on the Horizontal run to Sewer or vent connection. N.. vertical LIFT MUST PRECEDE HORIZONTAL RUN SANIPLUS PAGE 2

6. Installation TO E UNDERTAKEN Y A REGISTERED PLUMER IN CONJUNCTION WITH: AS3500 10:10 G G H The Saniplus should be installed to allow full access in the event that servicing and or removal is necessary. The Saniplus is supplied with floor mounting lugs and foam feet to minimise vibration and to prevent possible movement during operation. The Saniplus must be coupled directly to the spigot (outlet) of the P-trap WC pan. The Saniplus must be located on the same ground or floor level to that of the WC pan, do not locate in a pit or in-ground opening Connections - Incoming waste water All pipework (32/40mm ) from a vanity fixture running into the Saniplus must have a constant grade of 1:40. The inlet port for a Vanity basin connection is located on top of the Saniplus lid. If using the lid port use a stanley blade or hack-saw to remove the very top of the port to allow connection. Use rubber connectors and pipe clips (supplied) to make secure connections. Ensure connectors are facing in the right direction before securing. See diagram E on page 1. 1 20mm 2 G Position the pump so that it is not in contact with a partition or wall of the room. Place the Saniplus on a level surface to ensure that the foam feet are attached to the underside of the pump. Apply soapy water to the WC spigot and position the pan to the pump, ensuring that there is a 20mm gap between them. The reason for this is two-fold 1. If in contact with the pump sound vibration occurs, and 2. the pump can be removed if service is needed. Locate pan collar onto front of the pump, ensuring small diameter opening is secured to the pump using plastic cable tie provided. The other end of the pan collar has a larger opening to allow easier fitting to WC pan outlet (spigot). Pull the pan collar over the pan spigot Position the metal hose clip (G) over the end of the pan collar and tighten with a screwdriver. Once the pump has been positioned, use 2 screws through the floor mounting brackets to fix it to the floor. (optional) SANIPLUS PAGE 3

Connections - Extra bathroom fixtures E Plugging side inlet J Closed 1 2 E See figs 1 and 2 for connections that may be required for extra fixtures. SANIPLUS PAGE 4

Connections - Discharge outgoing waste water Select discharge pipework as follows:- Vertical lifts must occur prior to any horizontal runs, except for the initial short run at the pump connection, this should be NO MORE than 300mm in length. Only ONE vertical lift is permitted in the discharge line, all changes of direction in the discharge line MUST be made with 45deg bends rather than 90deg bends. For vertical pipework USE ONLY 20mm upvc (pressure pipe) Horizontal pipework ( following initial vertical lift ) can be upgraded by one size to 25mm. If manifolding more than one pump, sizing should be in line with fixture loading requirements. Once selection has been made, insert discharge elbow (supplied) into the rubber discharge pipe protruding from lid of the Saniplus, trim rubber connector to size and make connection between discharge elbow and upvc discharge pipe. efore securing all connections connect a PVC all Valve in the upvc pipework as near to the beginning of the discharge line as possible. Do NOT install a Non Return Valve ( NRV) in the discharge line as the discharge elbow (supplied) incorporates an inbuilt nrv. All horizontal pipework that follows initial Vertical Lift must run with a constant Downhill gradient of 1:100 MIN ( or better ) to eventual sewer or vent connection. Connection to sewer or vent stack can be made via a 45deg junction or boss-strap fitting. If running your discharge pipe-work below the floor level on which the pump is located ensure you install an Air Admitance Valve (AAV) at the highest point of the pipework, this will eliminate the effect of Syphonage. 1 2 3 ø 20mm A D 1 Insert the elbow (A) into the rubber discharge pipe that rises up through the lid and turn it clockwise to the direction required and secure with steel hose clip (). 2 Attach the rubber step down reducer to the discharge elbow and secure with steel hose clip (E). 3 Connect to the other end to 2Omm upvc pressure pipe, using steel hose clip (C). SANIPLUS PAGE 5

Vertical before horizontal 1:100 Air Admittance Valve 100/110mm Isolation valve 25mm 32mm 40mm 1% Ø 25mm max. 5m Ø 20mm 2nd possibility for connection of wash basin 3% Connections - venting Where possible venting should always be made in a manner consistent with common plumbing practice venting requirements referred to in Australian Standards AS 3500 10:10 & 6:7:4. You can use suitable pvc pipe or plastic hose to run the vent, either to the open atmosphere or to an existing vent stack located nearby. However if this is not possible, the Saniplus is supplied with a carbon filter pod and covering cap, periodical replacement of this filter pod is recommended approximately every 12 months.. SANIPLUS PAGE 6

7. Electrical connection TO E UNDERTAKEN Y A REGISTERED ELECTRICAL CONTRACTOR IN CONJUNCTION WITH : AS/NZS 3000.2007 The electrical installation should be carried out by a registered electrician. The Saniplus pump is equiped with a 3 core electrical cable which contains Earth Active and Neutral wires, it has a three pin moulded plug attachment. All wires in this cable are colour coded in accordance with International colour coding ie ROWN - ACTIVE ( LIVE), LUE - NEUTRAL, GREEN / YELLOW - EARTH. All wiring connections and GPO locations must conform to AS/NZS 3000:2007 requirements. Supply must be protected via a 30mA RCD rated at 16amps, located at the switchboard. The Saniplus requires a 240V single phase 50 Hz AC power supply If a decision is made to hard wire, then cost to disconnect and re-connect will be at consumers expense. 8. Commissioning the Saniplus pump EFORE COMMISSIONING THE PUMP MAKE SURE ALL CONNECTIONS ARE SECURE AND WATER-TIGHT Once ALL connections are secure and before you switch the power on, press the Full Flush button on your cistern and allow water to enter the pump, this allows the pump to prime. Once flush is complete switch the power to the pump ON. Your pump should immediately activate and begin discharging into the discharge pipe system. Initial run time is normally between 5-10 secs. Duration of run time is generally determined by the length of travel in the pump-out line and type of waste, Pump operation will shut down after this time. Should the pump continue running for longer than the recommended time, an installation or manufacturing problem may exist, immediately contact SANIFLO on 03 9543 3891 and speak with a Tech. support person, they will be only too happy to assist. 9. Approvals The Saniplus conforms to Australian and New Zealand standards AS/NZS Water Mark Approvals. A lifting plant for waste water containing faecal matter for limited applications and the European directives and standards concerning electrical safety and electromagnetic compatibility. Saniplus Société Française d Assainissement EN 12050-3 LA03-p30 220-240 V - 50 Hz - 400 W - IP44 1.9A - - 6.5 KG ATS 5200.101 Certificate No. 23048 Manufacturer: SFA rand: Saniflo 10. Care and use DO NOT... dispose of sanitary materials, plastics, wood, solvents, paints, turps, caustic acid, or other corrosive acids or cleaners. DO NOT... dispose of hot water in excess of 40º C. DO NOT... use lu Loo or similar products with your Saniplus as this may cause the pump to cavitate. Cavitation occurs when there is an excessive build of of Foam or Froth from detergents; this may cause motor damage. DO... dispose of Organic matter ie faeces and WC paper (with a full flush) and waste water ONLY. DO... periodically clean the Saniplus with a basic household detergent cleaner ie domestos, pine o clean or actizyme. DO... consider calling a Service agent, if you experience operational problems at any time, eg pump sounds different than it did during previous operation, sooner rather than later. Noise Levels All Sani pumps (domestic rated) conform to the National Code of Practice for Noise Management and Protection of Hearing in a workplace or domestic environs (NOHSC 2004-2009) All Saniflo grey water and macerator pumps are not in themselves very noisy and the sound of operation is generally not invasive. However, noise levels can be increased/amplified due to sympathetic resonance from stud partitions, some floors and tight locations. Example - decibel comparison People conversation (normal) 60-70 db Sanipumps (domestic) Max 65 db Toilet cistern flushing 75 db Vacuum cleaner 80 db SANIPLUS PAGE 7

11. Servicing Periodical servicing may be required, depending on your usage cycle. On average we would recommend that a service be undertaken every 2 years or alternatively if you believe that your Saniplus is not functioning as it has been, then give our Technical department a call to obtain details of your nearest Service Agent. Saniflo Technical support can be contacted on 03 9543 3891 General Servicing Line Assistance 0400 592 642 12. Warranty A 2 Yr Manufacturers Warranty applies to your Saniplus pump this commences from the date of purchase and is subject to CORRECT INSTALLATION and CORRECT USAGE. Any failure or motor burn-out attributed to incorrect installation or consumer misuse is NOT covered under this Warranty. 13. Fault Finding / Remedies For the most part, any inconsistencies in the operation of the unit will be minor and easily rectified. Please refer to the chart below. If the problem cannot be easily remedied in this way, please call our office on (03) 9543 3891 or National Service line on 0400 592 642. IN ALL CASES, YOU MUST DISCONNECT THE MACERATOR FROM THE POWER SUPPLY ALL WORK INVOLVING DISMANTLING OF THE APPLIANCE MUST E CARRIED OUT Y AN APPROVED REPAIR AGENT SYMPTOMS PROALE CAUSES REMEDIES The unit stops The motor intermittently activates An object is blocking the blades The unit has been running for too long and the (self re-setting) thermal cut out has engaged The connected fixtures are dripping The non-return valve is faulty Cistern is leaking Call approved service engineer. The unit will reset itself. Check the installation upstream Clean or replace the non-return valve (externally mounted) Call plumber to replace flush pipe seal The water in the WC pan goes down very slowly and is pumped away in bursts The air vent (under carbon filter) is clogged up The WC pan is partially blocked Clear the air vent. Clear the WC pan The motor operates normally, but continues to run for a long time The length or height of the installation is over the specification, or there are too many bends/elbows The pump chamber is blocked An electrical component has failed Check the installation Call approved service engineer The motor does not activate The electrical power supply is not active The motor or the control system is defective Restore the electrical supply Call approved service engineer The motor emits a rattling or crunching sound, hums, but does not run Foreign object in the pump Problem with the motor or the control system Call approved service engineer SANIPLUS PAGE 8

SANIPLUS PAGE 9 14. Parts 26a 26b 62 61 7 8 2a 35 34 1 5 11 38 39 18 48 14 41 15 17 63 10 3 50 40 4 24 20 31 37 2b 32 21e 21d 21c 21a 36 20b 28c 28a 12 31 31 White casing

15. Ten golden rules for correct installation 1 2 1:100 PVC all Value All horizontal pipes should have a minimum fall of 1:100. Discharge pipework should be solvent UPVC. Do not pushfit pipework/fittings. If a vertical rise is needed, this should be at the start of the run (within 30cm of the unit). 3 4 2 x 45 Offset Plastic Elbows ends should be smooth/long radius, not tight elbows. Examples of upvc Pressure Pipe and fittings shown. Waste Pipes entering the Saniflo unit should have a gravity fall of 1:40 Air admittance 5 6 valve Where the pipework falls below floor level, fit an air admittance valve at the highest point capable of withstanding 10psi neg pressure, or upsize pipe coming down to break syphonage. Each Saniflo discharge pipe should run separately to the sewer/vent pipe. If wastes are combined, it can only be connected to a larger pipe. This pipe must gravity fall to connection point. Easily 7 removable 8 panels The unit should be easily accessible and removable in the event of service or maintenance being required. If boxed in, the boxing should be easily removed. Any extension between the WC pan spigot and wall should not exceed 150mm and have a 1.40 fall. As close coupled cistern dimensions vary it may be necessary with certain designs to utilise a spacer between cistern and wall. 9 10 ELECTRICAL CLASS 1 PRODUCT Position the Saniflo unit directly behind the toilet pan, not underneath it. Connect to power according AS/NZS 3000: 2007 Electrical Regulation as rules apply depending on location. In ALL CASES supply must be protected by a 30mA RCD rated at 16A. After sales contact information: info@saniflo.com.au SANIPLUS PAGE 10