Legislation, Standards and Technology. Figure 1: 1897 Approved Electrical Fittings

Similar documents
Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

Setting the Standard in Third-party Certification

Annubar Flowmeter Series

Explosive atmospheres. IECEx. International Electrotechnical Commission

HazLoc Essential Guides:

Overview of Standards for CO Detection Products

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

FM Approvals & Water Mist Systems. Paul Bardsley Engineer, FM Approvals

Guide to Intrinsically Safe Portable Radios

1. Which national directives/laws control the placing on the market of equipment for explosive atmospheres?

Guide to Hazardous Location Approvals:

Understanding Hazardous and Explosion-Protection Environments

CURTIS-STRAUS LLC A BUREAU VERITAS COMPANY NRTL/SCC SOLUTION

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Compilation of regulatory approaches used in various countries. Information received by the Secretariat through a survey in 2009

Session Eight: It s Not Rocket Science Unless You Do It Wrong

Why manufacturers prefer the IECEx System

Meeting NFPA standards for

UL Listings & FM Approvals Their Impact on Fire Sprinkler System Performance/Design

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

The ATEX Directive 94/9/EC

International Product Compliance and Certifications. Product Safety Consulting, Inc.

International IECEx Certification Scheme as seen by an Oil & Gas Operator. The TOTAL E&P company viewpoint. Eric MEYER

Executive Summary. Shell Offshore Inc. BY: Keith M. Gonzales Sr., P.E. Regulatory Requirements for Hazardous Locations

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

IECEx Certificate of Conformity

EMIRATES CONFORMITY ASSESSMENT SCHEME (ECAS): ECASEx COMPLIANCE

(German speaking trainers with English written slides)

Changes to Certification and its Impact on Manufacturers. Des McDonell CSE-Ex Pty Ltd

EEHA CERTIFICATION FPSO S FOR INTERNATIONAL OPERATIONS


Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Intrinsically Safe Transmitters, Option Code 2n

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

Rosemount 702 Wireless Discrete Transmitter

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

Drive systems for the chemical, oil and gas industry. Electric drives and systems

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Rosemount 4500 Hygienic Pressure Transmitter. Start

Report on the activities of the ATEX consultant. Xavier Lefebvre. Contract : CENELEC/NA Consultant/2013-1

A COMPARISON OF FIRE ALARM SYSTEM REQUIREMENTS IN THE US AND UK. James R. Lugar Jr., P.E. Rolf Jensen & Associates, Inc. SFPE 2012 Savannah, GA

An Introduction to the IECEx System and IECEx Scheme Certification Processes IECEx Secretariat January 2018

UL HAZARDOUS LOCATIONS SERVICES

August Process Industry Practices Electrical. PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

ATEX Explained A brief Introduction

distributing & controlling system solutions

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

ORDINANCE NO

IEC SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR USE IN EXPLOSIVE ATMOSPHERES (IECEx SCHEME) INTRODUCTION

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

Hazardous Area Classifications and Protections

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

SMB/4676/R STRATEGIC BUSINESS PLAN (SBP) Title of TC TC 62: Electrical equipment in medical practice

A Guide to Safe Electronic Weighing in Hazardous Locations

The Worldwide Use of Fire Sprinklers

CERTIFICATION BODY ACCREDITATION PROGRAM (CBAP) Scope of Accreditation

SYSTEMS PRODUCT OVERVIEW

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

S T R I T T & P R I E B E I N C.

50 years of Eriez Magnetics Europe Limited

Understanding Hazardous Locations Concepts

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

specifically for explosion prone areas can substantially reduce the risk of combustion.

Consumer Protection: Standardized International Product Labels: 2. Scope of Labelling

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017

PROCESS AUTOMATION PEPPERL+FUCHS BEBCO EPS 6000 SERIES PURGE AND PRESSURIZATION SYSTEM

Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services

CertAlarm and its progress on a pan-european certification scheme

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

BUSINESS PLAN CEN/TC 10 LIFTS, ESCALATORS AND MOVING WALKS EXECUTIVE SUMMARY

NFPA Talking Points on NFPA 1 Fire Code update to the 2015 Edition:

Explosion-protected actuator Page 259 of 292

OVERVIEW OF INDIAN HAZARDOUS LOCATION SYSTEM. By B K Gupta

An Overview of Applicable ISA Standards to the Water and Wastewater Sectors

Crouse-Hinds Enclosures. High performance, high reliability enclosures for global applications

BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION EXECUTIVE SUMMARY

Demystifying Power Tap Use in Healthcare Settings John Garbarino Sr. Marketing Manager, Commercial/Industrial Leviton Manufacturing Co.

DUST EXPLOSION CODES AND STANDARDS: Ensuring Regional Compliance and Global Consistency

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

AUGUST 2016 CONTENTS:

Intrinsically Safe or Explosionproof? Understanding the technology

Global Conformity Assessment of Photovoltaic systems

The Process of making European Standards. Frank Moore Chairman CEN TC/248 Textiles

IECEx Certificate of Conformity

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction

BUSINESS PLAN CEN/TC 197 PUMPS EXECUTIVE SUMMARY

Combustible Dusts What do I do???

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas

ESSENTIAL EXPLOSION PROTECTION

polar zone components and systems for extreme temperatures

Overview of Hazardous Locations as They Relate to Solenoid Valves

Specifying Temperature Sensors for Hazardous Areas

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward

Training, Assessment, Consultants for Hazardous & Industrial Areas

Transcription:

Legislation, Standards and Technology FM Approvals Roots in the industrial revolution 1835 and the development to present by John Rennie and Bill Lawrence Figure 1: 1897 Approved Electrical Fittings In the beginning The Factory Mutual Fire Insurance Companies (known as the Factory Mutuals), can trace their roots back to 1835 when a New England mill owner pioneered the concept of highly protected risk for industrial textile manufacturing occupancies. The concept of shared risk based on sound property protection and engineering was inherent, even at the birth of the Factory Mutuals. In the 1800 s, engineers began testing products. These tests were to determine which cutting oils represented the best lubricant to reduce the potential of fire. The use of kerosene for illumination caused additional concern, until the Factory Mutuals, through a series of experiments published in the 1862 annual report of the Smithsonian Institute, showed that in industrial occupancies kerosene for illumination was no more dangerous than the use of candles or animal fat. The 1880 s brought important advances for the Factory Mutuals in the area of automatic sprinklers. In 1886, FM Laboratories was established as a wholly owned subsidiary of the Factory Mutuals. They were pioneers in their fields and established the first permanent laboratories in the United States dedicated to the testing of fire protection devices; this distinction may even apply worldwide. In 1897, the Inspection Department of the Factory Mutuals published a book titled Approved Electrical Fittings containing products they had tested, such as lamp sockets, receptacles, flexible cord fuses, conduit circuit breakers, arc switches, and lighting arrestors (Figure 1). Electrical product testing actually predated the aforementioned book, and historical records reflect concern for electrical installation and products since 1882. This book reflected 9 pages of products and related manufacturing organizations. Over the years, elements of the Inspection Department have transitioned to the organization known today as FM Approvals. Workload in numbers and complexity has increased immensely since the first electrical product approvals in 1897. The product approvals publication became known as the Approval Guide and now contains more than 45,000 certified products. While FM Approvals is involved in the certification of dozens of categories of product and services, the main focus is on electrical equipment for use in hazardous locations, building materials, and fire protection products, such as automatic sprinklers, and alarm and signaling equipment.

Ex-Magazine 2007 36 37 The first hazardous location products The year was 1922, and FM Laboratories had moved its fire testing facility from its first home in Woburn, Massachusetts (MA) (Figure 2) to Everett, MA. The engineers were in the process of conducting a series of tests to study explosions of flammable dusts and vapors in special enclosures. It was also the year that marked the first certification of electrical equipment for use in hazardous locations. Testing was completed on vapor-proof enclosures manufactured by Appleton Electric, Benjamin Electric, Crouse-Hinds and V.V. Fitting Company. Some of these names are still familiar to the market today. FM Laboratories has always understood the need for standards from both the product and the installation point of view. The Factory Mutuals worked with others in the insurance industry to establish an electrical installation code in 1894, which in 1897 became the major source for the first U.S. National Electrical Code (NEC) (Figure 3). While electrical codes came into existence in 1894, the first installation rules specific to electrical equipment for use in hazardous locations, were not reflected in the NEC until 1923 the year following the first certifications. In 1924 FM Laboratories established a fee-for-service program. Previously, this work had been done free of charge. In 1941, the FM Laboratories changed their name to the Factory Mutual Research Corporation (FMRC). FMRC was incorporated as a nonprofit corporation and continued with its testing and research work, which was primarily related to the war effort. The 1940 s and 1950 s were significant for FMRC as they moved test operations from Everett to Norwood, MA (Figure 4) where they constructed a full scale fire test center. Figure 2: Woburn Fire Text Facility 1886 Years of expansion The early 1960 s brought an invitation to join a new committee on an emerging hazardous location electrical protection method for the US called intrinsic safety. The committee was being formed by the Instrument Society of America (now ISA). FMRC accepted the invitation and subsequently took part in other ISA hazardous location committees. FMRC and its successors now have more than 40 years of association with ISA. In fact, FMRC has the distinction of having four of its engineers receive the ISA Standards and Practices Award for outstanding contribution in the field of instrumentation, systems, and automation. Over the years, FMRC has played a leading role in the development of hazardous location protection techniques through, not only ISA, but also the National Fire Ë Figure 3: 1923 National Electrical Code

FM Approvals Roots in the industrial revolution 1835 and the development to present Figure 4: Norwood Fire Test Facility 1947 Protection Association (NFPA) and the International Electrotechnical Commission (IEC). The 60 s saw the FMRC reach another milestone with the construction of the world s largest fire test and research building in West Gloucester, Rhode Island (RI). The test building exceeded 4,000 m2 in size and sat on 6 km2 of land. If the 1960 s were busy for hazardous location testing, they paled in comparison to the coming decade. In 1971, the US Department of Labor enacted the Occupational Safety and Health Act (Title 29), which for all practical purposes empowered OSHA (the Occupational Safety and Health Administration) to demand that hazardous location electrical equipment be approved or certified by specific testing labs like FMRC (Figure 5). The work grew exponentially while the engineering staff struggled to maintain pace with industry demands for product approvals. Not only did the manufacturing work grow but committee demands also increased. FMRC continued to serve on the executive committee of the United States National Committee of the IEC and as the Technical Advisor to the US IEC TC 31 committee. The committee work also included leadership positions such as, secretary and chair of various ISA committees and subcommittees, and as an active member of the NFPA Committee on Electrical Equipment in Chemical Atmospheres. FMRC was also active in the NFPA National Electrical Code Committee, particularly in the panel dealing with the installation rules for Hazardous Location Electrical equipment. Outside the US Work continued to escalate in the 1980 s, with US manufacturers continuing to look overseas for new and expanding markets. To help meet their demand for supporting international certification, FMRC began to look at opportunities outside the US. In 1982, FMRC was accepted by the Standards Association of Australia as one of the first overseas test labs supporting Australian Certification of hazardous location equipment. In 1986, the first Mutual Recognition Agreement was signed with the Physikalisch-Technische Bundesanstalt (PTB) in Germany, followed by agreements with other well-known labs in Europe, Canada, South America, Asia, and Australia (Figure 6). In 1988, OSHA formalized the US test laboratory recognition system by instituting the Nationally Recognized Testing Laboratory (NRTL) program. FMRC has been accredited under this program since its inception. Regardless of US or world economy, the workload continued to increase at dramatic rates through the rest of the 80 s and 90 s. In 1996, the US joined the rest of the world with the recognition of the three-zone area classification system and the associated types of protection. This was the culmination of a 25 year struggle within the US to agree on a way to accept the IEC system into the long-established and well-developed US system for hazardous location electrical equipment. FMRC was at the forefront of various committee activities to develop acceptable product and installation standards. By 1999, the 42 companies that once made up the Factory Mutuals had combined and merged over the years into three companies, Arkwright Mutual Insurance Company, Allendale Mutual Insurance Company, and Protection Mutual Insurance Company. These three then merged one last time into a single entity, the Factory Mutual Insurance Company, doing business as FM Global. The merger of the three parent insurance companies resulted in a series of major changes to FMRC. Figure 5: FM Approvals Certification Mark

Ex-Magazine 2007 38 39 Figure 6: Mutual Recognition Agreements In 2002, FMRC became FM Global Technologies LLC. One of its Divisions, FM Approvals, was responsible for continuing the activities in product testing and certification. Preparing for the future In late 2003, the 60 million Euro upgrade and expansion of the West Glocester, RI Test Center was completed and dedicated as the FM Global Research Campus (Figure 7). As part of the expansion, the hazardous lo cation (explosive atmospheres) testing was relocated from Norwood, MA to the Research Campus. New computerized gas mixing and explosion pressure measurement systems have been implemented in the control room at the new facility to expedite the testing and improve the data consistency (Figure 8). Also included is the ability to test much larger samples in the large (160 m2) test bay with a 6 m ceiling (Figure 9). Global Reach In 2004, ongoing efforts to expand global certification solutions beyond the Mutual Recognition Agreements, led towards new accreditations by IECEx, Canada, and Europe. In 2004, FM Approvals (a Division of FM Global Technologies) was accredited as an ExCB (Certification Body) and ExTL (Test Laboratory) under the IECEx Certification Scheme allowing for the preparation of Ex- TRs (Test Reports) QARs (Quality Assessment Reports) and CoCs (Certificates of Conformity). In 2005, FM Approvals (a Division of FM Global Technologies) was accredited by the Standards Council of Canada (SCC) as a Certification Body and Testing Organization for Canada for all electrical products. Although many jurisdictions, nationally and internationally, had accepted the work of FM Approvals, this was the first time the FM Approvals mark was formally recognized outside of the United States. Ë

FM Approvals Roots in the industrial revolution 1835 and the development to present Figure 8: Control Room Figure 7: Research Campus (West Glocester/RI) Figure 9: Explosive Gas Test Facility (West Glocester/RI) Also in 2005, to support the growing business in China, FM Approvals opened its first office outside the United States; in Beijing, China. In January 2006, FM Global Technologies LLC became FM Approvals LLC, the current legal name of the certification operation that had been doing business under the communicative name of FM Approvals since 2002. In 2006, to support the continued growth of business in Asia, FM Approvals opened a second office outside of the United States, in Singapore. Also in 2006, in a major expansion to Europe, FM Approvals Ltd was established and appointed by the Government of the United Kingdom as an European Notified Body for the Explosive Atmospheres (ATEX) Directive (EG Directive 94/9/EG regarding to explosion protection). The FM Approvals office in Windsor, United Kingdom, works closely with the test facilities in Norwood and West Glocester in the US to support the ATEX Certification effort. FM Approvals was now in a position to issue US, Canadian, and European Certifications as a single source provider. This provides manufacturers with a fast, economical, path to global markets. In early 2007, FM Approvals Ltd received accreditation as a Product Certification Body by the United Kingdom Accreditation Service (UKAS). With UKAS accreditation now in place, FM Approvals Ltd is expected to soon be recognized by IECEx as an ExCB. What makes FM Approvals different? FM Approvals interests parallel those of FM Global. FM Global, as the world s largest industrial and commercial property insurer, has a major interest in property loss prevention aspects of the products certified by FM Approvals. FM Global engineers, more than 1500 world wide, operating out of 55 offices, conduct more than 600,000 property inspections per year in 110 countries, and recommend the use of FM Approved products. This provides an opportunity to promote the use of FM Approved products and monitor the product s loss prevention performance over its lifetime.

Ex-Magazine 2007 40 41 Figure 10: Canadian Certification Marks Figure 11: EG Conformity mark and ATEX Certification mark of explosion protection The future The 172 year history had numerous high points, which will be matched or exceeded in the future. FM Approvals will continue to expand its global presence and product certifications. Such an expansion will improve the availability of quality loss prevention products and services, which will also benefit industry in general. www.fmapprovals.com