14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

Similar documents
DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

14 AC x

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

2 shp 13 lc 1 36 t - 1 a

XC17. DAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology. SEER up to to 5 Tons Cooling Capacity - 21,800 to 59,000 Btuh

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

T S A 048 S 4 N 4 1 T

T P A 048 S 4 N 4 1 T

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

DAVE LENNOX SIGNATURE COLLECTION WITH SILENTCOMFORT TECHNOLOGY

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

T P A 120 S 4 S N 1 Y

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes August 2008

ELITE Series R-410A - Two-Stage Compressor

Visit us at For the latest technical information,

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes April 2008

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

SSB. S CLASS SPLIT SYSTEM R 410A Two Stage Compressor 60 HZ A I R C O N D I T I O N E R S

MERIT SERIES Up Flow / Horizontal

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

ELITE Series Variable Capacity

ELITE Series Variable Capacity

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

T-Class AC and HP Units Up to SEER and 9.0 HSPF. Commercial Air Conditioners and Heat Pumps. True performance and rugged durability

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

13 GEP A L P - 1 A

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

XC21. DAVE LENNOX SIGNATURE COLLECTION R-410A - Two-Stage Compressor - SilentComfort Technology

15CHPX. DAVE LENNOX SIGNATURE COLLECTION Residential - R-410A - Variable Speed Blower

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

True performance and rugged durability. Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 16.2 SEER

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

C22FC Bulletin # October 1993 Supersedes May 1993

Commercial High-Efficiency Condensing Units

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

RGE 13 A T - 1 A

C22 Bulletin # October 1993 Supersedes May 1993

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

MACH N-407 Heat Pump Air-Cooled Chiller

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

Ruud Achiever Series Air Conditioners

Commercial High-Efficiency Condensing Units

T-SERIES COMMERCIAL SPLIT SYSTEMS 6- TO 20-TON ELP/ELS MODELS UP TO 12.0 EER

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

PACKAGE AIR CONDITIONER

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Lennox 8 Series Single Zone - R-410A

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

WCH5**4. Product Specifications

R4H4. Product Specifications

Air Handlers and Indoor Coils Up to 20 Tons. CB* and C* Models. True performance and rugged durability

R4H4. Product Specifications

Split System Cooling Product & Performance Data

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

PRODUCT SPECIFICATIONS

CB X 32 mv

Corp L2 Revised

MAC N-407 Air-Cooled Chiller

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

Split System Heat Pump Product Data

PAJ3. Product Specifications

TECHNICAL SPECIFICATIONS

MAC-120HE-03 Air-Cooled Chiller

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

N4H4. Product Specifications

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Product Data. Split System Heat Pump B-EN. February A6H6024H1000A

Split System Heat Pump Product Data

TECHNICAL SPECIFICATIONS

HSXA15 HSXB15. IMPORTANT Operating pressures of this R410A unit are higher than pressures in R22 units. Always use service equipment rated for R410A.

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

TECHNICAL SPECIFICATIONS

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Transcription:

E N G I N E E R I N G D A T A H E A T P U M P O U T D O O R U N I T S 14HPX MERIT SERIES R 410A Bulletin No. 210492 April 2008 Supersedes April 2007 SEER up to 15.0 1.5 to 5 Tons Capacity 19,100 to 59,000 Btuh Heating Capacity 16,700 to 56,000 Btuh MODEL NUMBER IDENTIFICATION Unit Type HP = Heat Pump Outdoor Unit Refrigerant X = R 410A Nominal SEER 14 HP X 024 230 2 Minor Revision Number Voltage 230 = 208/230V 1 phase 60hz Nominal Capacity 018 = 1.5 tons 024 = 2 tons 030 = 2.5 tons 036 = 3 tons 042 = 3.5 tons 048 = 4 tons 060 = 5 tons

FEATURES CONTENTS ARI Indoor Coil / Air Handler Substitution....... Page 9 ARI Rating Tables...................... Pages 10 23 Dimensions................................. Page 8 Electrical Data.............................. Page 5 Features................................... Page 2 Field Wiring................................ Page 7 Installation Clearances....................... Page 7 Model Number Identification.................. Page 1 Optional Accessories........................ Page 5 Outdoor Sound Data......................... Page 7 Specifications............................ Pages 5 6 Warranty Compressor limited warranty for five years in residential installations and five years in non residential installations. All other covered components five years in residential installations and one year in non residential installations.. Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. Approvals Certified in Accordance with the USE certification program, which is based on ARI Standard 210/240. Sound rated in Lennox reverberant sound test room in Accordance with test conditions included in ARI Standard 270. Tested in the Lennox Research Laboratory environmental test room. Rated According to U.S. Department of Energy (DOE) test procedures. Units and components within bonded for grounding to meet safety standards for servicing required by UL, NEC and CEC. Units are UL and ULC listed. ISO 9001 Registered Manufacturing Quality System. Applications SEER up to 15.0. Heating COP up to 4.08. (Region IV) up to 9.00. 1.5 through 5 tons. Single phase power supply. Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof. Designed for applications with remotely located indoor air handler units or gas furnaces with indoor add on coils. When heat pumps are used with gas furnaces, a dual fuel control (i.e. FM21) or a control system with dual fuel capabilities (i.e. Harmony III, LZP 2 or LZP 4) must be used (ordered extra). See Indoor Coils and sections for indoor unit data. Units shipped completely factory assembled, piped and wired. Each unit is test operated at the factory insuring proper operation. Installer must set outdoor unit, connect refrigerant lines and make electrical connections to complete job. For expanded ratings, see www.lennoxdavenet.com. B C D C B G D E F I H J REFRIGERATION SYSTEM Refrigerant Non chlorine, ozone friendly, R 410A. Unit is factory pre charged with refrigerant. Total system refrigerant charge is dependant on outdoor unit size, indoor unit size and refrigerant line length. Refer to Installation Instructions for "Indoor Unit Match Up and Sub Charge Levels" to determine correct amount of charge required. See Specification table. Outdoor Coil Fan Direct drive fan moves large air volumes uniformly through entire outdoor coil for high refrigerant cooling and heating capacity. Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs. Fan motor has sleeve bearings and is inherently protected. Motor totally enclosed for maximum protection from weather, dust and corrosion. Louvered steel top fan guard furnished as standard. Fan service access accomplished by removal of top panel. Copper Tube/Enhanced Fin Coil Lennox designed and fabricated coil. Ripple-edged aluminum fins. Copper tube construction. Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer. Fin collars grip tubing for maximum contact area. Flared shoulder tubing connections/silver soldering construction. Coil is factory tested under high pressure to ensure leakproof construction. Entire coil is accessible for cleaning. PVC coated steel wire coil guard furnished as standard. 14HPX 1.5 to 5 Ton Heat Pump / Page 2

FEATURES E F REFRIGERATION SYSTEM (CONTINUED) Valve Outdoor Unit Designed and sized specifically for use in heat pump system. Sensing bulb is located on the suction line between the reversing valve and the compressor to sense evaporator suction temperature in the heat cycle. Pressure Switch Protects the system from high pressure conditions that can be a result of fan failure or a blocked/dirty coil. Automatic reset. Capacity Liquid Line Drier Factory installed in the liquid line, the drier traps moisture or dirt that could contaminate the refrigerant system. 100% molecular sieve, bead type bi flow drier. Reversing Valve 4-way interchange reversing valve effects a rapid change in direction of refrigerant flow resulting in quick changeover from cooling to heating and vice versa. Valve operates on pressure differential between outdoor unit and indoor unit of the system. Factory installed. OPTIONS Check/ Valve Kits Must be ordered extra and field installed on certain indoor units. See ARI Ratings tables. Chatleff style fitting. Loss of Charge Kit Helps protect the compressor from damage due low refrigerant charge conditions. SPST, normally closed switch, automatic reset switch. Refrigerant Line Kits Refrigerant lines (suction & liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized and sealed at factory. Suction line fully insulated. Lines are stubbed at both ends. Not available for 060 models and must be field fabricated. G Compressor Scroll Compressor Compressor features high efficiency with uniform suction flow, constant discharge flow and high volumetric efficiency and quiet operation. Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them. During compression, one scroll remains stationary while the other scroll orbits around it. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates. As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced. When pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls. During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle. Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency. Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to to be worked toward the center and discharged. gas pulses during compression reduces operational sound levels. Compressor motor is internally protected from excessive current and temperature. Muffler in discharge line reduces operating sound levels. Compressor is installed in the unit on resilient rubber mounts for vibration free operation. Compressor Crankcase Heater (Factory installed on 036 042 048 060 models) Protects against refrigerant migration that can occur during low ambient operation. OPTIONS Compressor Crankcase Heater (Optional for 018 024 030 models) Protects against refrigerant migration that can occur during low ambient operation. Compressor Sound Cover A reinforced vinyl compressor cover containing a 1 1/2 inch thick batt of fiberglass insulation. All open edges are sealed with a one inch wide hook and loop fastening tape. 14HPX 1.5 to 5 Ton Heat Pump / Page 3

FEATURES H CONTROLS Defrost Control Solid-state control furnished as standard. Gives a demand defrost cycle whenever system heating performance falls below optimum levels. The sensing element on coil determines when defrost cycle is required and when to terminate cycle. Anti short cycle (5 minutes) incorporated into the board. Diagnostic LED s furnished as an aid in troubleshooting. Conveniently located in control box. OPTIONS Compressor Hard Start Kit Single phase units are equipped with a PSC compressor motor. This type of motor normally doesn t need a potential relay and start capacitor. In conditions such as low voltage, this kit may be required to increase the compressor starting torque. Compressor Ambient Cut Off Non-adjustable switch (low ambient cut-out) prevents compressor operation in cooling mode, when outdoor temperature is below 35 F. Freezestat Installs on or near the vapor line of the indoor coil or on the suction line. Senses suction line temperature and cycles the compressor off when suction line temperature falls below it s setpoint. Opens at 29 F and closes at 58 F. Indoor Blower Off Delay Relay Kit Delays the indoor blower off time during the cooling cycle. See ARI Rating Tables for usage. Ambient Kit Heat pump units will operate satisfactorily in the cooling mode down to 45 F outdoor air temperature without any additional controls. Kit can be added in the field enabling unit to operate properly down to 30 F in the cooling mode. Crankcase heater and freezestat should be installed on compressors equipped with a low ambient kit. A compressor lock out thermostat should be added to terminate compressor operation below recommended operation conditions. Mild Weather Kit Heat pump units operate satisfactorily in the heating mode at outdoor air temperatures up to 75 F. Mild Weather Kit can be field installed, allowing heating operation above 75 F. Monitor Kit Service Light Contains ambient compensating thermistor and service light thermostat. For use with thermostats requiring input for indicator lights. Outdoor Thermostat Kit An outdoor thermostat can be used to lock out some of the electric heating elements on indoor units where two stage control is applicable. Outdoor thermostat maintains the heating load on the low power input as long as possible before allowing the full power load to come on the line. Thermostat kit and mounting box must be ordered extra. Thermostat Thermostat not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book. I J Cabinet Heavy gauge steel cabinet with five station metal wash process. Powder paint finish provides superior rust and corrosion protection. Painted base section. Control box is conveniently located with all controls factory wired. Corner patch plate allows access to compressor components. Drainage holes are provided in base section for moisture removal. Refrigerant Line Connections, Electrical Inlets, Service Valves Sweat connection vapor and liquid lines are located on corner of unit cabinet. Fully serviceable brass service valves prevent corrosion and provide access to refrigerant system. Vapor valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system. Refrigerant line connections and field wiring inlets are located in one central area of cabinet for easy access. See dimension drawing. OPTIONS Hail Guards Constructed of louvered heavy gauge steel painted to match cabinet. Surrounds unit on all four sides to prevent damage to the coil. Mounting Base Provides permanent foundation for outdoor units. density polyethylene structural material is lightweight, sturdy, sound absorbing and will withstand the rigors of the sun, heat, cold, moisture, oil and refrigerant. Will not mildew or rot. Can be shipped singly or in packages of 6 to a carton. Unit Stand-Off Kit Black high density polyethylene feet are available to raise unit off of mounting surface away from damaging moisture. Four feet are furnished per order number. 14HPX 1.5 to 5 Ton Heat Pump / Page 4

SPECIFICATIONS General Model No. 14HPX 018 14HPX 024 14HPX 030 6 14HPX 036 Data Nominal Tonnage 1.5 2 2.5 3 1 Sound Rating Number 76 76 76 79 Connections Liquid line o.d. in. 3/8 3/8 3/8 3/8 (sweat) Vapor line o.d. in. 3/4 3/4 3/4 7/8 2 Refrigerant R 410A charge furnished 8 lbs. 4 oz. 8 lbs. 0 oz. 7 lbs. 2 oz. 9 lbs. 12 oz. Outdoor Net face area Outer coil 13.30 13.30 15.21 19.39 Coil sq. ft. Inner coil 12.60 12.60 14.50 18.77 Tube diameter in. 5/16 5/16 5/16 5/16 No. of rows 2 2 2 2 Fins per inch 22 22 22 22 Outdoor Diameter in. 18 18 18 26 Fan No. of Blades 3 3 3 4 Motor hp 1/10 1/10 1/10 1/3 Cfm 2165 2165 2232 4090 Rpm 1015 1015 1035 844 Watts 171 171 165 299 Shipping Data lbs. 1 package 156 156 166 212 ELECTRICAL DATA Line voltage data 60 hz 1ph 208/230V 208/230V 208/230V 208/230V 3 Maximum overcurrent protection (amps) 20 30 30 30 4 Minimum circuit ampacity 11.9 17.5 17.0 19.4 Compressor Rated Load Amps 8.97 13.46 13.1 14.1 Locked Rotor Amps 48 58 64 77 Power Factor 0.96 0.97 0.98 0.98 Outdoor Full Load Amps 0.70 0.70 0.70 1.8 Fan Motor Locked Rotor Amps 1.4 1.4 1.4 2.9 OPTIONAL ACCESSORIES must be ordered extra Compressor Crankcase Heater 93M04 Factory Compressor Hard Start Kit 10J42 Compressor Ambient Cut Off 45F08 Compressor Sound Cover 69J03 Freezestat 3/8 in. tubing 93G35 5/8 in. tubing 50A93 Hail Guards 92M89 92M88 27W34 Indoor Blower Off Delay Relay 58M81 Loss of Charge Kit 84M23 5 Ambient Kit 54M89 Mild Weather Kit 33M07 Monitor Kit Service Light 76F53 Mounting Base 69J06 69J07 Outdoor Thermostat 56A87 Thermostat Kit Mounting Box 31461 Refrigerant L15 41 20 L15 41 40 Line Sets L15 41 30 L15 41 50 L15 65 30 L15 65 40 L15 65 50 Unit Stand Off Kit 94J45 NOTE Extremes of operating range are plus 10% and minus 5% of line voltage. 1 Sound Rating Number rated in accordance with test conditions included in ARI Standard 270. 2 Refrigerant charge sufficient for 15 ft. length of refrigerant lines. 3 HACR type circuit breaker or fuse. 4 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 5 Crankcase Heater and Freezestat are recommended with Ambient Kit. 6 14HPX 036 not available in Canada. 14HPX 1.5 to 5 Ton Heat Pump / Page 5

SPECIFICATIONS General Model No. 14HPX 042 14HPX 048 14HPX 060 Data Nominal Tonnage 3.5 4 5 1 Sound Rating Number 79 80 80 Connections Liquid line o.d. in. 3/8 3/8 3/8 (sweat) Vapor line o.d. in. 7/8 7/8 1-1/8 2 Refrigerant R 410A charge furnished 12 lbs. 7 oz. 12 lbs. 10 oz. 16 lbs. 0 oz. Outdoor Coil Outdoor Fan Net face area sq. ft. Outer coil 24.93 24.93 29.09 Inner coil 24.13 24.13 28.16 Tube diameter in. 5/16 5/16 5/16 No. of rows 2 2 2 Fins per inch 22 22 22 Diameter in. 26 26 26 No. of Blades 4 4 4 Motor hp 1/3 1/3 1/3 Cfm 4347 4347 4550 Rpm 843 843 830 Watts 299 299 307 Shipping Data lbs. 1 package 257 262 307 ELECTRICAL DATA Line voltage data 60 hz 1ph 208/230V 208/230V 208/230V 3 Maximum overcurrent protection (amps) 40 50 60 4 Minimum circuit ampacity 24.2 29 34.8 Compressor Rated Load Amps 17.94 21.79 26.41 Locked Rotor Amps 112 117 134 Power Factor 0.94 0.95 0.98 Outdoor Full Load Amps 1.8 1.8 1.8 Fan Motor Locked Rotor Amps 2.9 2.9 2.9 OPTIONAL ACCESSORIES must be ordered extra Compressor Crankcase Heater Factory Compressor Hard Start Kit 10J42 81J69 Compressor Ambient Cut Off 45F08 Compressor Sound Cover 69J03 Freezestat 3/8 in. tubing 93G35 5/8 in. tubing 50A93 Hail Guards 27W36 94M94 Indoor Blower Off Delay Relay 58M81 Loss of Charge Kit 84M23 5 Ambient Kit 54M89 Pressure Switch Bypass Thermostat 13W07 Mild Weather Kit 33M07 Monitor Kit Service Light 76F53 Mounting Base 69J07 Outdoor Thermostat 56A87 Thermostat t Kit Mounting Box 31461 Refrigerant Line Sets L15 65 30 L15 65 40 L15 65 50 Field Fabricate Unit Stand Off Kit 94J45 NOTE Extremes of operating range are plus 10% and minus 5% of line voltage. 1 Sound Rating Number rated in accordance with test conditions included in ARI Standard 270. 2 Refrigerant charge sufficient for 15 ft. length of refrigerant lines. 3 HACR type circuit breaker or fuse. 4 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 5 Crankcase Heater and Freezestat are recommended with Ambient Kit. 14HPX 1.5 to 5 Ton Heat Pump / Page 6

INSTALLATION CLEARANCES INCHES (MM) See NOTES NOTES: Service clearance of 30 in. (762 mm) must be maintained on one of the sides adjacent to the control box. See NOTES See NOTES Clearance to one of the other three sides must be 36 in. (914 mm ) Clearance to one of the remaining two sides may be 12 in. (305 mm) and the final side may be 6 in. (152 mm). See NOTES CONTROL BOX A clearance of 24 in. (610 mm) must be maintained between two units. 48 in. (1219 mm) clearance required on top of unit. FIELD WIRING A DISCONNECT SWITCH (By Others) OPTIONAL OUTDOOR THERMOSTAT LENNOX OUTDOOR UNIT D OPTIONAL ELECTRIC HEAT LENNOX INDOOR UNIT B DISCONNECT SWITCH (By Others) THERMOSTAT (Optional) C A Two Wire Power (see Electrical Data) B Two or Three Wire Power (size to heater capacity) C Twelve Wire Voltage 18 ga. minimum Fourteen Wire Voltage with Optional Outdoor Thermostat D Eight Wire Voltage 18 ga. minimum Ten Wire Voltage with Optional Outdoor Thermostat Field Wiring Not Furnished All wiring must conform to NEC or CEC and local electrical codes. OUTDOOR SOUND DATA Octave Band Sound Power Levels dba, re 10 1 Watts 1 Unit Sound Center Frequency HZ Model No. Rating 125 250 500 1000 2000 4000 8000 Number (db) 14HPX 018 72 70.5 68.5 68 65 59.5 53.5 76 14HPX 024 71 74.5 2.5 71.5 68 62.5 56.5 76 14HPX 030 70.5 70.5 71.5 71.5 66 62.5 59 76 14HPX 036 78.5 77.5 77.5 74.5 69.5 63.5 61.5 79 14HPX 042 76.5 78 78.5 73.5 69.5 63.5 58.5 79 14HPX 048 75.5 78 78.5 75 70 63.5 58.5 80 14HPX 060 75 77.5 77.5 75.5 70 65 65 80 NOTE the octave sound power data does not include tonal correction. 1 Tested according to ARI Standard 270 test conditions. 14HPX 1.5 to 5 Ton Heat Pump / Page 7

DIMENSIONS INCHES (MM) INLET AIR 4-3/8 (111) 4-3/8 (111) 4-3/8 (111) 4-3/8 (111) INLET INLET OPTIONAL UNIT STAND-OFF KIT (4) (Field Installed) COMPRESSOR AIR AIR COIL DRAIN OUTLETS (Around perimeter of base) VAPOR LINE CONNECTION 6-3/8 (162) 4-3/8 (111) INLET AIR TOP VIEW LIQUID LINE CONNECTION 6-3/8 4-3/8 (162) (111) TOP VIEW BASE SECTION A CONDENSER COIL FAN DISCHARGE A AIR COMPRESSOR C B SUCTION & LIQUID LINE CONNECTIONS ELECTRICAL INLETS 2 (51) 2-3/4 (70) SIDE VIEW 3/4 (19) OPTIONAL UNIT STAND-OFF KIT (4) (Field Installed) SIDE VIEW Model No. A B C in. mm in. mm in. mm 14HPX 018 14HPX 024 24-1/4 616 29-1/4 743 28-1/2 724 14HPX 030 24-1/4 616 33-1/4 845 32-1/2 826 14HPX 036 32 1/4 819 29-1/4 743 28-1/2 724 14HPX 042 14HPX 048 32-1/4 819 37 940 36 1/4 921 14HPX 060 32 1/4 819 43-1/4 1099 42-1/2 1080 14HPX 1.5 to 5 Ton Heat Pump / Page 8

INDOOR COIL / AIR HANDLER SUBSTITUTION Substituting Coils in the ARI Tables Most R 22 and R 410A indoor coils and air handlers are the same except for the factory installed expansion device. C33 coils can be used in place of the CX34 coils, CB26UH, CB27UH, and CB30M air handlers can be used in place of the CBX26UH, CBX27UH, and CBX32M, respectively. UP FLOW COILS R 410A R 22 CX34 18/24A 6F = C33 24A 2 CX34 18/24B 6F = C33 24B 2 CX34 18/24C 6F = C33 24C 2 CX34 19A 6F = C33 19A 2 CX34 25A 6F = C33 25A 2 CX34 25B 6F = C33 25B 2 CX34 30A 6F = C33 30A 2 CX34 30B 6F = C33 30B 2 CX34 30C 6F = C33 30C 2 CX34 31A 6F = C33 31A 2 CX34 31B 6F = C33 31B 2 CX34 36A 6F = C33 36A 2 CX34 36B 6F = C33 36B 2 CX34 36C 6F = C33 36C 2 CX34 38A 6F = C33 38A 2 CX34 38B 6F = C33 38B 2 CX34 42B 6F = C33 42B 2 CX34 43B 6F = C33 43B 2 CX34 43C 6F = C33 43C 2 no equivalent C33 44C 2 CX34 44/48B 6F = C33 48B 2 CX34 44/48C 6F = C33 48C 2 CX34 49C 6F = C33 49C 2 CX34 50/60C 6F = C33 50/60C 2 CX34 60D 6F = C33 60D 2 CX34 62C 6F = C33 62C 2 CX34 62D 6F = C33 62D 2 The expansion device is based on the size of the outdoor unit. The factory installed RFC or TXV on the C33/CB26UH/CB27UH/CB30M must be replaced to correspond to the outdoor unit. The correct TXV s are: 1.5 3 ton heat pumps 49L24 3.5 ton heat pumps 49L25 4 5 ton heat pumps 91M02 Example: A four ton heat pump is being installed. The ARI table shows that CBX32M 048 is a matching air handler. A CB30M 51 with a 91M02 TXV can be used in its place. AIR HANDLERS R 410A R 22 CBX26UH 018 = CB26UH 018 R CBX26UH 024 = CB26UH 024 R CBX26UH 030 = CB26UH 030 R CBX26UH 036 = CB26UH 036 R CBX26UH 042 = CB26UH 042 R CBX26UH 048 = CB26UH 048 CBX26UH 060 = CB26UH 060 R CBX27UH 018/024 = CB27UH 018/024 CBX27UH 030 = CB27UH 030 CBX27UH 036 = CB27UH 036 CBX27UH 042 = CB27UH 042 CBX27UH 048 = CB27UH 048 CBX27UH 060 = CB27UH 060 CBX32M 018/024 = CB30M 21/26 CBX32M 030 = CB30M 31 CBX32M 036 = CB30M 41 CBX32M 042 = CB30M 46 CBX32M 048 = CB30M 51 CBX32M 060 = CB30M 65 CBX32MV all no equivalent 14HPX 1.5 to 5 Ton Heat Pump / Page 9

Heating Heating 14HPX 018 14HPX 1.5 to 5 Ton Heat Pump / Page 10 1.5 TON 19,100 16,800 10,100 14.00 12.00 7.70 6.70 1590 1450 1350 3.40 2.20 4,5 CBX32MV 018/024 (Multi Position) Factory TXV 19,400 16,700 10,000 15.00 12.50 8.00 6.70 1550 1375 1280 3.56 2.28 4 CBX27UH 018 (Up Flow / Horizontal) Factory TXV 14HPX 024 2 TON 23,000 23,400 14,900 13.00 11.00 7.70 6.70 2090 1935 1825 3.54 2.40 4 CBX32M 018/024 (Multi Position) Factory TXV 23,400 23,200 14,800 14.00 11.50 8.20 7.20 2035 1855 1755 3.66 2.46 4 CBX32MV 018/024 (Multi Position) Factory TXV 23,600 23,200 14,700 14.00 12.00 8.20 7.20 1965 1800 1720 3.78 2.50 4 CBX32MV 024/030 (Multi Position) Factory TXV 23,600 23,200 14,700 14.00 12.00 8.20 7.20 1965 1810 1730 3.76 2.48 4 CBX32M 030 (Multi Position) Factory TXV 23,600 23,200 14,700 14.00 12.00 8.20 7.20 1965 1865 1740 3.64 2.48 5 CBX26UH 024 (Up Flow / Horizontal) Factory TXV 24,200 23,000 14,400 15.00 13.00 9.00 7.50 1935 1690 1620 3.98 2.60 4 CBX27UH 024 (Up Flow / Horizontal) Factory TXV Up Flow Indoor Coils Up Flow Coils 23,200 23,200 14,800 13.00 11.00 7.70 6.70 2110 1975 1870 3.44 2.32 3 CX34 36A/B/C 6F Factory TXV 23,400 23,200 14,700 13.00 11.00 7.70 6.70 2125 1990 1940 3.42 2.22 3 CX34 25A 6F Factory TXV 23,600 23,400 15,000 13.00 11.00 7.70 6.70 2145 1920 1795 3.58 2.44 3 CX34 38A 6F Factory TXV 23,800 23,200 14,700 13.00 11.00 7.70 6.70 2165 1995 1930 3.40 2.24 3 CX34 31A 6F Factory TXV Up Flow Indoor Coils + Furnaces Up Flow Coils + Furnaces 23,800 22,600 14,300 15.00 12.50 8.20 7.20 1905 1760 1660 3.76 2.52 CX34 36B 6F 4 G60UHV 36B 090 Factory TXV 23,800 22,600 14,300 15.00 12.50 8.20 7.20 1905 1775 1665 3.74 2.52 CX34 36C 6F 4 G61MPV 36C 090 Factory TXV 23,800 22,600 14,300 15.00 12.50 8.20 7.20 1905 1775 1665 3.74 2.52 CX34 36C 6F 4 G71MPP 36C 090 Factory TXV 23,800 22,800 14,300 15.00 12.50 8.20 7.20 1905 1780 1680 3.76 2.50 CX34 36B 6F 4 G61MPV 36B 070 Factory TXV 23,800 22,800 14,300 15.00 12.50 8.20 7.20 1905 1780 1680 3.76 2.50 CX34 36B 6F 4 G71MPP 36B 070 Factory TXV 23,800 22,800 14,400 14.50 12.50 8.20 7.20 1905 1785 1685 3.74 2.50 CX34 36A 6F 4 G60UHV 36A 070 Factory TXV 23,800 22,800 14,400 14.50 12.50 8.20 7.20 1905 1785 1685 3.74 2.50 CX34 36B 6F 4 G61MPV 36B 045 Factory TXV 24,000 22,600 14,200 15.00 12.50 8.00 7.00 1920 1775 1725 3.74 2.42 CX34 25B 6F 4 G60UHV 36B 090 Factory TXV 24,000 22,600 14,200 15.00 12.50 8.20 7.00 1920 1795 1745 3.70 2.38 CX34 25B 6F 4 G61MPV 36B 070 Factory TXV 24,000 22,600 14,200 15.00 12.50 8.20 7.00 1920 1795 1745 3.70 2.38 CX34 25B 6F 4 G71MPP 36B 070 Factory TXV 24,000 22,800 14,300 14.50 12.50 8.00 7.00 1920 1820 1775 3.68 2.36 CX34 25A 6F 4 G60UHV 36A 070 Factory TXV 24,000 22,800 14,300 15.00 12.50 8.20 7.00 1920 1800 1755 3.72 2.38 CX34 25B 6F 4 G61MPV 36B 045 Factory TXV 24,200 22,800 14,400 15.00 13.00 9.00 7.50 1935 1710 1590 3.90 2.66 CX34 38B 6F 4 G60UHV 36B 090 Factory TXV 24,200 23,000 14,500 15.00 12.50 8.20 7.50 1935 1735 1615 3.88 2.62 CX34 38A 6F 4 G60UHV 36A 070 Factory TXV 24,200 23,000 14,500 15.00 12.50 8.50 7.50 1935 1735 1615 3.88 2.62 CX34 38B 6F 4 G61MPV 36B 045 Factory TXV 24,200 23,000 14,500 15.00 13.00 9.00 7.50 1935 1725 1610 3.90 2.64 CX34 38B 6F 4 G61MPV 36B 070 Factory TXV 24,200 23,000 14,500 15.00 13.00 9.00 7.50 1935 1725 1610 3.90 2.64 CX34 38B 6F 4 G71MPP 36B 070 Factory TXV 24,400 22,600 14,200 15.00 12.50 8.20 7.00 1950 1800 1750 3.68 2.38 CX34 31A 6F 4 G60UHV 36A 070 Factory TXV 24,400 22,600 14,200 15.00 12.50 8.20 7.00 1950 1780 1725 3.72 2.42 CX34 31B 6F 4 G60UHV 36B 090 Factory TXV 24,400 22,600 14,200 15.00 12.50 8.20 7.00 1950 1795 1745 3.70 2.38 CX34 31B 6F 4 G61MPV 36B 070 Factory TXV 24,400 22,600 14,200 15.00 12.50 8.20 7.00 1950 1795 1745 3.70 2.38 CX34 31B 6F 4 G71MPP 36B 070 Factory TXV 24,400 22,800 14,300 15.00 12.50 8.20 7.00 1950 1795 1755 3.72 2.38 CX34 31B 6F 4 G61MPV 36B 045 Factory TXV Down Flow Indoor Coils Down Flow Coils 23,600 23,400 15,000 13.00 11.00 7.70 6.70 2145 1900 1770 3.60 2.48 3 CR33 30/36A/B/C F 2 49L24 Ratings 95 F outdoor air temperature and 80 F db/67 F wb entering indoor coil air. Temperature Heating Ratings 47 F db/43 F wb outdoor air temperature and 70 F db entering indoor coil air. Temperature Heating Ratings 17 F db/15 F wb outdoor air temperature and 70 F db entering indoor coil air. 5 Most popular air handler combination.

Heating Heating 14HPX 024 Down Flow Indoor Coils + Furnaces Down Flow Coils + Furnaces 24,200 22,800 14,400 15.00 13.00 9.00 7.70 1935 1700 1570 3.94 2.68 CR33 30/36C F 4 G61MPV 36C 090 2 49L24 24,200 22,800 14,400 15.00 13.00 9.00 7.70 1935 1700 1570 3.94 2.68 CR33 30/36C F 4 G71MPP 36C 090 2 49L24 24,200 23,000 14,500 15.00 13.00 9.00 7.70 1935 1705 1585 3.96 2.68 CR33 30/36B F 4 G61MPV 36B 070 2 49L24 24,200 23,000 14,500 15.00 13.00 9.00 7.70 1935 1705 1585 3.96 2.68 CR33 30/36B F 4 G71MPP 36B 070 2 49L24 24,200 23,000 14,600 15.00 13.00 9.00 7.70 1935 1715 1595 3.94 2.68 CR33 30/36B F 4 G61MPV 36B 045 2 49L24 24,200 23,200 14,700 14.50 12.50 8.50 7.70 1935 1730 1615 3.94 2.66 CR33 30/36A F 4 G60DFV 36A 070 2 49L24 24,600 23,200 14,600 15.00 13.00 9.00 7.70 1970 1670 1565 4.08 2.74 CR33 30/36B F 4 G60DFV 36B 090 2 49L24 Horizontal Indoor Coils Horizontal Coils 23,200 23,200 14,700 13.00 11.00 7.70 6.70 2110 2010 1940 3.38 2.22 3 CH33 36A 2F 2 49L24 23,400 23,200 14,700 13.00 11.00 7.70 6.70 2125 1985 1940 3.42 2.22 3 CH33 25A 2F 2 49L24 23,400 23,200 14,900 13.00 11.00 7.70 6.70 2125 1970 1840 3.46 2.38 3 CH23 41 2 49L24 23,400 23,400 14,900 13.00 11.00 7.70 6.70 2125 1930 1850 3.56 2.36 3 CH33 36C 2F 2 49L24 23,600 23,200 14,700 13.00 11.00 7.70 6.70 2145 1990 1935 3.42 2.22 3 CH33 42B 2F 2 49L24 23,800 23,200 14,700 13.00 11.00 7.70 6.70 2165 1960 1945 3.46 2.22 3 CH33 31A 2F 2 49L24 23,800 23,200 14,700 13.00 11.00 7.70 6.70 2165 1975 1940 3.44 2.22 3 CH33 31B 2F 2 49L24 Horizontal Indoor Coils + Furnaces Horizontal Coils + Furnaces 23,800 22,800 14,300 14.50 12.00 7.70 6.70 1985 1830 1775 3.66 2.36 CH33 36A 2F 4 G60UHV 36A 070 2 49L24 24,000 22,400 14,200 15.00 13.00 9.00 7.70 1920 1715 1590 3.82 2.62 CH23 41 4 G61MPV 36C 090 2 49L24 24,000 22,400 14,200 15.00 13.00 9.00 7.70 1920 1715 1590 3.82 2.62 CH23 41 4 G71MPP 36C 090 2 49L24 24,000 22,600 14,200 15.00 12.50 8.20 7.50 1920 1720 1600 3.86 2.60 CH23 41 4 G60UHV 36A 070 2 49L24 24,000 22,600 14,200 15.00 12.50 8.20 7.50 1920 1720 1600 3.86 2.60 CH23 41 4 G61MPV 36B 070 2 49L24 24,000 22,600 14,200 15.00 12.50 8.20 7.50 1920 1720 1600 3.86 2.60 CH23 41 4 G71MPP 36B 070 2 49L24 24,000 22,600 14,200 15.00 12.50 8.20 7.50 1920 1720 1600 3.86 2.60 CH23 41 4 G61MPV 36B 071 2 49L24 24,000 22,800 14,300 14.50 12.50 8.00 6.70 1920 1810 1775 3.70 2.36 CH33 25A 2F 4 G60UHV 36A 070 2 49L24 24,000 22,800 14,300 15.00 12.50 8.20 7.00 1920 1730 1655 3.86 2.54 CH33 36C 2F 4 G61MPV 36C 090 2 49L24 24,000 22,800 14,300 15.00 12.50 8.20 7.00 1920 1730 1655 3.86 2.54 CH33 36C 2F 4 G71MPP 36C 090 2 49L24 24,200 22,400 14,100 15.00 13.00 9.00 7.70 1935 1690 1570 3.88 2.62 CH23 41 4 G60UHV 36B 090 2 49L24 24,200 22,600 14,300 15.00 12.50 8.20 7.50 1935 1725 1605 3.84 2.60 CH23 41 4 G61MPV 36B 045 2 49L24 24,400 22,400 14,000 15.00 12.50 8.20 7.00 1950 1710 1660 3.84 2.46 CH33 42B 2F 4 G60UHV 36B 090 2 49L24 24,400 22,600 14,100 15.00 12.50 8.20 7.00 1950 1740 1690 3.80 2.44 CH33 42B 2F 4 G61MPV 36B 070 2 49L24 24,400 22,600 14,100 15.00 12.50 8.20 7.00 1950 1740 1690 3.80 2.44 CH33 42B 2F 4 G71MPP 36B 070 2 49L24 24,400 22,600 14,100 15.00 12.50 8.20 7.00 1950 1740 1695 3.80 2.44 CH33 42B 2F 4 G61MPV 36B 045 2 49L24 24,400 22,600 14,100 15.00 12.50 8.20 7.00 1950 1740 1690 3.80 2.44 CH33 42B 2F 4 G61MPV 36B 071 2 49L24 24,400 22,600 14,200 15.00 12.50 8.20 7.00 1950 1760 1730 3.76 2.40 CH33 31B 2F 4 G60UHV 36B 090 2 49L24 24,400 22,800 14,200 15.00 12.50 8.00 7.00 1950 1780 1745 3.76 2.38 CH33 31B 2F 4 G61MPV 36B 070 2 49L24 24,400 22,800 14,200 15.00 12.50 8.00 7.00 1950 1780 1745 3.76 2.38 CH33 31B 2F 4 G71MPP 36B 070 2 49L24 24,400 22,800 14,200 15.00 12.50 8.00 7.00 1950 1780 1745 3.76 2.38 CH33 31B 2F 4 G61MPV 36B 071 2 49L24 24,400 22,800 14,300 15.00 12.50 8.00 6.70 1950 1790 1780 3.74 2.36 CH33 31A 2F 4 G60UHV 36A 070 2 49L24 24,400 22,800 14,300 15.00 12.50 8.00 7.00 1950 1785 1755 3.74 2.38 CH33 31B 2F 4 G61MPV 36B 045 2 49L24 2 TON Ratings 95 F outdoor air temperature and 80 F db/67 F wb entering indoor coil air. Temperature Heating Ratings 47 F db/43 F wb outdoor air temperature and 70 F db entering indoor coil air. Temperature Heating Ratings 17 F db/15 F wb outdoor air temperature and 70 F db entering indoor coil air. 14HPX 1.5 to 5 Ton Heat Pump / Page 11

Heating Heating 14HPX 030 2.5 TON 27,600 28,000 17,000 13.0 11.50 8.20 7.00 2350 2250 2070 3.64 2.40 4 CBX32M 030 (Multi Position) Factory TXV 28,000 28,200 17,000 14.0 12.00 8.20 7.00 2330 2200 2035 3.76 2.44 4 CBX32MV 024/030 (Multi Position) Factory TXV 28,200 28,200 17,100 14.0 12.00 8.20 7.00 2340 2185 2010 3.78 2.50 5 CBX26UH 030 (Up Flow / Horizontal) Factory TXV 28,400 28,000 16,800 14.5 12.00 8.20 7.00 2280 2135 1990 3.84 2.48 4 CBX32MV 036 (Multi Position) Factory TXV 28,400 28,200 17,100 14.0 12.00 8.20 7.00 2345 2180 2045 3.80 2.44 4 CBX32M 036 (Multi Position) Factory TXV 28,600 27,800 16,600 15.0 12.50 8.50 7.00 2225 2080 1930 3.92 2.52 4 CBX27UH 030 (Up Flow / Horizontal) Factory TXV Up Flow Indoor Coils Up Flow Coils 26,800 27,000 17,100 13.0 11.00 7.70 6.70 2420 2355 2080 3.36 2.40 3 CX34 44/48C 6F 2 49L24 26,800 27,400 17,200 13.0 11.00 7.70 6.70 2420 2255 2035 3.56 2.48 3 CX34 38A/B 6F Factory TXV 27,000 27,200 17,100 13.0 11.00 7.70 6.70 2420 2305 2060 3.46 2.44 3 CX34 31B 6F Factory TXV 27,200 27,200 17,200 13.0 11.00 7.70 6.70 2420 2295 2050 3.48 2.46 3 CX34 43B/C 6F 2 49L24 Up Flow Indoor Coils + Furnaces Up Flow Coils + Furnaces 27,200 27,000 16,800 14.0 11.50 8.20 7.20 2330 2210 1965 3.58 2.50 CX34 31B 6F 4 G61MPV 36B 045 Factory TXV 27,200 27,200 17,100 14.0 11.50 8.20 7.20 2330 2160 1945 3.70 2.58 CX34 38B 6F 4 G61MPV 36B 045 Factory TXV 27,400 26,800 16,600 14.0 11.50 8.20 7.20 2260 2135 1890 3.68 2.58 CX34 31A 6F 4 G60UHV 36A 070 Factory TXV 27,400 26,800 16,600 14.0 11.50 8.20 7.20 2275 2150 1905 3.66 2.56 CX34 31B 6F 4 G61MPV 36B 070 Factory TXV 27,400 26,800 16,600 14.0 11.50 8.20 7.20 2275 2150 1905 3.66 2.56 CX34 31B 6F 4 G71MPP 36B 070 Factory TXV 27,400 26,800 16,600 14.0 11.50 8.20 7.20 2275 2150 1905 3.66 2.56 CX34 31B 6F 4 G61MPV 36B 071 Factory TXV 27,400 26,800 16,600 14.5 12.00 8.50 7.50 2225 2050 1825 3.84 2.66 CX34 38B 6F 4 G60UHV 36B 090 Factory TXV 27,400 27,000 16,700 14.0 11.50 8.20 7.20 2260 2085 1865 3.80 2.62 CX34 38A 6F 4 G60UHV 36A 070 Factory TXV 27,400 27,000 16,700 14.0 11.50 8.20 7.50 2275 2095 1880 3.78 2.60 CX34 38B 6F 4 G61MPV 36B 070 Factory TXV 27,400 27,000 16,700 14.0 11.50 8.20 7.50 2275 2095 1880 3.78 2.60 CX34 38B 6F 4 G71MPP 36B 070 Factory TXV 27,400 27,000 16,700 14.0 11.50 8.20 7.50 2275 2095 1880 3.78 2.60 CX34 38B 6F 4 G61MPV 36B 071 Factory TXV 27,400 27,000 17,000 14.0 11.50 8.20 7.20 2330 2195 1970 3.60 2.52 CX34 43B 6F 4 G61MPV 36B 045 2 49L24 27,600 26,600 16,500 14.5 12.00 8.50 7.50 2225 2100 1855 3.72 2.60 CX34 31B 6F 4 G60UHV 36B 090 Factory TXV 27,800 26,600 16,600 15.0 12.00 8.50 7.50 2225 2090 1860 3.74 2.62 CX34 43B 6F 4 G60UHV 36B 090 2 49L24 27,600 26,800 16,700 14.5 11.50 8.20 7.20 2275 2135 1895 3.68 2.58 CX34 43B 6F 4 G61MPV 36B 070 2 49L24 27,600 26,800 16,700 14.5 11.50 8.20 7.20 2275 2135 1895 3.68 2.58 CX34 43B 6F 4 G71MPP 36B 070 2 49L24 27,600 26,800 16,700 14.5 11.50 8.20 7.20 2275 2135 1895 3.68 2.58 CX34 43B 6F 4 G61MPV 36B 071 2 49L24 27,800 26,200 16,100 15.0 13.00 9.00 7.50 2140 2050 1785 3.74 2.64 CX34 44/48C 6F 4 G61MPV 36C 090 2 49L24 27,800 26,200 16,100 15.0 13.00 9.00 7.50 2140 2050 1785 3.74 2.64 CX34 44/48C 6F 4 G71MPP 36C 090 2 49L24 27,800 26,600 16,500 15.0 12.00 8.50 7.50 2220 2075 1835 3.76 2.64 CX34 43C 6F 4 G61MPV 36C 090 2 49L24 27,800 26,600 16,500 15.0 12.00 8.50 7.50 2220 2075 1835 3.76 2.64 CX34 43C 6F 4 G71MPP 36C 090 2 49L24 Down Flow Indoor Coils Down Flow Coils 27,600 28,600 17,400 13.0 11.00 7.70 6.70 2410 2235 2060 3.76 2.48 3 CR33 30/36A/B/C F 2 49L24 Ratings 95 F outdoor air temperature and 80 F db/67 F wb entering indoor coil air. Temperature Heating Ratings 47 F db/43 F wb outdoor air temperature and 70 F db entering indoor coil air. Temperature Heating Ratings 17 F db/15 F wb outdoor air temperature and 70 F db entering indoor coil air. 5 Most popular air handler combination. 14HPX 1.5 to 5 Ton Heat Pump / Page 12

Heating Heating 14HPX 030 Down Flow Indoor Coils + Furnaces Down Flow Coils + Furnaces 28,000 28,200 17,100 14.0 11.50 8.20 7.20 2320 2145 1970 3.86 2.54 CR33 30/36B F 4 G61MPV 36B 045 2 49L24 28,200 28,000 16,900 14.5 11.50 8.20 7.20 2265 2085 1915 3.94 2.58 CR33 30/36B F 4 G61MPV 36B 070 2 49L24 28,200 28,000 16,900 14.5 11.50 8.20 7.20 2265 2085 1915 3.94 2.58 CR33 30/36B F 4 G71MPP 36B 070 2 49L24 28,200 28,200 17,000 14.0 12.00 8.20 7.20 2275 2095 1925 3.94 2.58 CR33 30/36A F 4 G60DFV 36A 070 2 49L24 28,400 28,000 16,800 14.5 12.00 8.20 7.20 2230 2050 1880 4.00 2.62 CR33 30/36C F 4 G61MPV 36C 090 2 49L24 28,400 28,000 16,800 14.5 12.00 8.20 7.20 2230 2050 1880 4.00 2.62 CR33 30/36C F 4 G71MPP 36C 090 2 49L24 28,600 28,000 16,800 15.0 12.50 8.50 7.20 2220 2030 1865 4.04 2.64 CR33 30/36B F 4 G60DFV 36B 090 2 49L24 2.5 TON Horizontal Indoor Coils Horizontal Coils 26,400 27,200 17,100 13.0 11.00 7.70 6.70 2400 2330 2080 3.42 2.40 3 CH23 41 2 49L24 26,400 27,200 17,100 13.0 11.00 7.70 6.70 2400 2310 2065 3.46 2.42 3 CH23 51 2 49L24 26,400 27,400 17,200 13.0 11.00 7.70 6.70 2400 2285 2045 3.52 2.46 3 CH33 36C 2F 2 49L24 26,800 27,200 17,100 13.0 11.00 7.70 6.70 2420 2305 2060 3.46 2.44 3 CH33 42B 2F 2 49L24 27,000 27,400 17,300 13.0 11.00 7.70 6.70 2420 2235 2010 3.60 2.52 3 CH33 31A 2F 2 49L24 27,200 27,400 17,200 13.0 11.00 7.70 6.70 2420 2280 2045 3.52 2.46 3 CH33 31B 2F 2 49L24 Horizontal Indoor Coils + Furnaces Horizontal Coils + Furnaces 27,000 26,600 16,400 14.5 11.50 8.20 7.50 2220 2095 1855 3.72 2.58 CH23 41 4 G61MPV 36B 045 2 49L24 27,000 26,600 16,500 14.5 11.50 8.20 7.50 2220 2070 1840 3.76 2.62 CH23 51 4 G61MPV 36B 045 2 49L24 27,200 26,400 16,200 15.0 12.00 8.50 7.50 2155 2025 1785 3.82 2.66 CH23 41 4 G60UHV 36A 070 2 49L24 27,200 26,400 16,300 15.0 12.00 8.50 7.50 2180 2045 1810 3.78 2.64 CH23 41 4 G61MPV 36B 070 2 49L24 27,200 26,400 16,300 15.0 12.00 8.50 7.50 2180 2045 1810 3.78 2.64 CH23 41 4 G71MPP 36B 070 2 49L24 27,200 26,400 16,300 15.0 12.00 8.50 7.50 2180 2045 1810 3.78 2.64 CH23 41 4 G61MPV 36B 071 2 49L24 27,200 26,400 16,300 15.0 12.00 8.50 7.50 2155 2005 1770 3.86 2.70 CH23 51 4 G60UHV 36A 070 2 49L24 27,200 26,600 16,400 15.0 12.00 8.50 7.70 2180 2020 1795 3.86 2.68 CH23 51 4 G61MPV 36B 070 2 49L24 27,200 26,600 16,400 15.0 12.00 8.50 7.70 2180 2020 1795 3.86 2.68 CH23 51 4 G71MPP 36B 070 2 49L24 27,200 26,600 16,400 15.0 12.00 8.50 7.70 2180 2020 1795 3.86 2.68 CH23 51 4 G61MPV 36B 071 2 49L24 27,200 26,800 16,600 14.5 11.50 8.20 7.50 2240 2060 1840 3.82 2.64 CH33 36C 2F 4 G61MPV 36C 090 2 49L24 27,200 26,800 16,600 14.5 11.50 8.20 7.50 2240 2060 1840 3.82 2.64 CH33 36C 2F 4 G71MPP 36C 090 2 49L24 27,200 27,000 16,900 14.0 11.50 8.20 7.20 2330 2205 1975 3.58 2.50 CH33 42B 2F 4 G61MPV 36B 045 2 49L24 27,400 26,200 16,100 15.0 12.00 8.50 7.70 2130 2000 1760 3.84 2.68 CH23 41 4 G60UHV 36B 090 2 49L24 27,400 26,400 16,100 15.0 12.00 8.50 7.50 2140 2005 1770 3.86 2.66 CH23 41 4 G71MPP 36C 090 2 49L24 27,400 26,400 16,100 15.0 12.00 8.50 7.50 2140 2005 1770 3.86 2.66 CH23 41 4 G61MPV 36C 090 2 49L24 27,400 26,400 16,200 15.0 12.00 8.50 7.70 2130 1975 1745 3.92 2.72 CH23 51 4 G60UHV 36B 090 2 49L24 27,400 26,400 16,200 15.0 12.00 8.50 7.70 2140 1980 1750 3.90 2.72 CH23 51 4 G61MPV 36C 090 2 49L24 27,400 26,400 16,200 15.0 12.00 8.50 7.70 2140 1980 1750 3.90 2.72 CH23 51 4 G71MPP 36C 090 2 49L24 27,400 26,600 16,500 14.5 11.50 8.20 7.20 2225 2095 1850 3.72 2.62 CH33 42B 2F 4 G60UHV 36B 090 2 49L24 27,400 26,800 16,600 14.0 11.50 8.20 7.20 2275 2140 1900 3.68 2.56 CH33 42B 2F 4 G61MPV 36B 070 2 49L24 27,400 26,800 16,600 14.0 11.50 8.20 7.20 2275 2140 1900 3.68 2.56 CH33 42B 2F 4 G71MPP 36B 070 2 49L24 27,400 26,800 16,600 14.0 11.50 8.20 7.20 2275 2140 1900 3.68 2.56 CH33 42B 2F 4 G61MPV 36B 071 2 49L24 27,400 27,000 16,800 14.0 11.50 8.20 7.50 2280 2085 1865 3.80 2.64 CH33 31A 2F 4 G60UHV 36A 070 2 49L24 27,400 27,000 16,900 14.0 11.50 8.20 7.20 2330 2185 1950 3.62 2.54 CH33 31B 2F 4 G61MPV 36B 045 2 49L24 27,600 26,800 16,500 15.0 12.00 8.50 7.50 2225 2075 1840 3.78 2.62 CH33 31B 2F 4 G60UHV 36B 090 2 49L24 27,600 26,800 16,700 14.5 11.50 8.20 7.20 2275 2120 1890 3.70 2.58 CH33 31B 2F 4 G61MPV 36B 070 2 49L24 27,600 26,800 16,700 14.5 11.50 8.20 7.20 2275 2120 1890 3.70 2.58 CH33 31B 2F 4 G71MPP 36B 070 2 49L24 27,600 26,800 16,700 14.5 11.50 8.20 7.20 2275 2120 1890 3.70 2.58 CH33 31B 2F 4 G61MPV 36B 071 2 49L24 Ratings 95 F outdoor air temperature and 80 F db/67 F wb entering indoor coil air. Temperature Heating Ratings 47 F db/43 F wb outdoor air temperature and 70 F db entering indoor coil air. Temperature Heating Ratings 17 F db/15 F wb outdoor air temperature and 70 F db entering indoor coil air. 14HPX 1.5 to 5 Ton Heat Pump / Page 13

Heating Heating 14HPX 036 34,400 35,400 21,400 14.0 12.00 8.20 7.20 2865 2790 2570 3.72 2.44 4 CBX32M 042 (Multi Position) 2 49L25 3 TON 34,400 35,600 21,400 14.0 12.00 8.20 7.20 2865 2785 2575 3.74 2.44 4 CBX32M 036 (Multi Position) Factory TXV 34,600 35,200 21,400 14.0 12.00 8.20 7.20 2885 2830 2595 3.64 2.42 5 CBX26UH 037 (Up Flow / Horizontal) Factory TXV 34,600 35,400 21,400 14.0 12.00 8.20 7.20 2885 2760 2550 3.76 2.46 4 CBX32MV 036 (Multi Position) Factory TXV 34,800 35,000 21,000 15.0 12.50 8.50 7.20 2785 2670 2450 3.84 2.50 4 CBX27UH 036 (Up Flow / Horizontal) Factory TXV 35,800 35,200 21,200 15.0 12.50 8.50 7.20 2865 2685 2485 3.84 2.50 4 CBX32MV 048 (Multi Position) 2 49L25 Up Flow Indoor Coils Up Flow Coils 34,400 35,400 21,600 13.0 11.00 7.70 6.70 3125 2950 2705 3.52 2.34 3 CX34 38A/B 6F 2 49L25 34,600 34,800 21,200 13.0 11.00 7.70 6.70 3145 3130 2855 3.26 2.18 3 CX34 44/48B/C 6F Factory TXV 35,000 35,000 21,200 13.0 11.00 7.70 6.70 3180 3065 2820 3.34 2.20 3 CX34 50/60C 6F 2 49L25 35,200 35,000 21,200 13.0 11.00 7.70 6.70 3200 3055 2815 3.36 2.20 3 CX34 43B/C 6F Factory TXV 35,400 35,000 21,200 13.0 11.00 7.70 6.70 3220 3045 2805 3.36 2.22 3 CX34 49C 6F 2 49L25 Up Flow Indoor Coils + Furnaces Up Flow Coils + Furnaces 34,600 35,000 21,200 14.0 12.00 8.20 7.20 2885 2825 2575 3.64 2.42 CX34 38B 6F 4 G61MPV 36B 070 2 49L25 34,600 35,000 21,200 14.0 12.00 8.20 7.20 2885 2825 2575 3.64 2.42 CX34 38B 6F 4 G71MPP 36B 070 2 49L25 34,600 35,000 21,200 14.0 12.00 8.20 7.20 2885 2825 2575 3.64 2.42 CX34 38B 6F 4 G61MPV 36B 071 2 49L25 34,800 34,400 20,800 14.0 12.00 7.70 6.70 2900 3010 2735 3.34 2.22 CX34 44/48B 6F 4 G61MPV 36B 045 Factory TXV 34,800 35,200 21,200 14.0 12.00 8.20 7.20 2900 2835 2595 3.64 2.40 CX34 38A 6F 4 G60UHV 36A 070 2 49L25 34,800 35,200 21,200 14.0 12.00 8.20 7.20 2900 2835 2595 3.64 2.40 CX34 38A 6F 4 G60UHV 36A 070 2 49L25 34,800 35,200 21,400 14.0 12.00 8.20 7.20 2900 2850 2610 3.62 2.40 CX34 38B 6F 4 G61MPV 36B 045 2 49L25 35,000 34,200 20,600 15.0 12.50 8.00 6.70 2800 2930 2655 3.42 2.28 CX34 44/48C 6F 4 G61MPV 36C 090 Factory TXV 35,000 34,200 20,600 15.0 12.50 8.00 6.70 2800 2930 2655 3.42 2.28 CX34 44/48C 6F 4 G71MPP 36C 090 Factory TXV 35,000 34,400 20,800 14.5 12.00 8.00 6.70 2915 3005 2725 3.36 2.24 CX34 44/48B 6F 4 G61MPV 36B 070 Factory TXV 35,000 34,400 20,800 14.5 12.00 8.00 6.70 2915 3005 2725 3.36 2.24 CX34 44/48B 6F 4 G71MPP 36B 070 Factory TXV 35,000 34,400 20,800 14.5 12.00 8.00 6.70 2915 3005 2725 3.36 2.24 CX34 44/48B 6F 4 G61MPV 36B 071 Factory TXV 35,000 34,800 21,000 15.0 12.50 8.50 7.20 2800 2735 2495 3.72 2.46 CX34 38B 6F 4 G60UHV 36B 090 2 49L25 35,200 34,000 20,400 15.0 12.50 8.00 6.70 2815 2875 2595 3.46 2.30 CX34 43B 6F 4 G60UHV 36B 090 Factory TXV 35,200 34,200 20,600 15.0 12.50 8.00 6.70 2815 2910 2645 3.44 2.28 CX34 44/48B 6F 4 G60UHV 36B 090 Factory TXV 35,400 34,400 20,600 15.0 12.50 8.20 6.70 2830 2865 2620 3.52 2.30 CX34 50/60C 6F 4 G61MPV 36C 090 Factory TXV 35,400 34,400 20,600 15.0 12.50 8.20 6.70 2830 2865 2620 3.52 2.30 CX34 50/60C 6F 4 G71MPP 36C 090 Factory TXV 35,400 34,400 20,800 15.0 12.50 8.00 6.70 2830 2910 2655 3.46 2.30 CX34 44/48C 6F 4 G61MPV 60C 090 Factory TXV 35,400 34,400 20,800 15.0 12.50 8.00 6.70 2830 2910 2655 3.46 2.30 CX34 44/48C 6F 4 G71MPP 60C 090 Factory TXV 35,400 34,600 20,800 14.5 12.50 8.00 6.70 2830 2935 2695 3.46 2.26 CX34 43B 6F 4 G61MPV 36B 045 Factory TXV 35,400 34,600 20,800 14.5 12.50 8.00 6.70 2830 2925 2685 3.46 2.26 CX34 43B 6F 4 G61MPV 36B 070 Factory TXV 35,400 34,600 20,800 14.5 12.50 8.00 6.70 2830 2925 2685 3.46 2.26 CX34 43B 6F 4 G71MPP 36B 070 Factory TXV Up Flow Indoor Coils + Furnaces Continued on Next Page Ratings 95 F outdoor air temperature and 80 F db/67 F wb entering indoor coil air. Temperature Heating Ratings 47 F db/43 F wb outdoor air temperature and 70 F db entering indoor coil air. Temperature Heating Ratings 17 F db/15 F wb outdoor air temperature and 70 F db entering indoor coil air. 5 Most popular air handler combination. 14HPX 1.5 to 5 Ton Heat Pump / Page 14

Heating Heating 14HPX 036 Up Flow Indoor Coils + Furnaces Continued from Previous Page 3 TON 35,400 34,600 20,800 14.5 12.50 8.00 6.70 2830 2925 2685 3.46 2.26 CX34 43B 6F 4 G61MPV 36B 071 Factory TXV 35,600 34,400 20,600 15.0 12.50 8.00 6.70 2850 2855 2610 3.54 2.32 CX34 43C 6F 4 G61MPV 36C 090 Factory TXV 35,600 34,400 20,600 15.0 12.50 8.00 6.70 2850 2855 2610 3.54 2.32 CX34 43C 6F 4 G71MPP 36C 090 Factory TXV 35,800 34,600 20,800 15.0 12.50 8.00 7.00 2865 2845 2620 3.56 2.32 CX34 50/60C 6F 4 G61MPV 60C 090 2 49L25 35,800 34,600 20,800 15.0 12.50 8.00 7.00 2865 2845 2620 3.56 2.32 CX34 50/60C 6F 4 G71MPP 60C 090 2 49L25 36,000 34,400 20,600 15.0 12.50 8.20 7.00 2880 2845 2605 3.54 2.32 CX34 49C 6F 4 G61MPV 36C 090 2 49L25 36,000 34,400 20,600 15.0 12.50 8.20 7.00 2880 2845 2605 3.54 2.32 CX34 49C 6F 4 G71MPP 36C 090 2 49L25 36,000 34,600 20,800 15.0 12.50 8.20 7.00 2880 2845 2615 3.56 2.32 CX34 43C 6F 4 G61MPV 60C 090 Factory TXV 36,000 34,600 20,800 15.0 12.50 8.20 7.00 2880 2845 2615 3.56 2.32 CX34 43C 6F 4 G71MPP 60C 090 Factory TXV 36,400 34,600 20,800 15.0 12.50 8.20 7.00 2910 2825 2610 3.58 2.34 CX34 49C 6F 4 G61MPV 60C 090 2 49L25 36,400 34,600 20,800 15.0 12.50 8.20 7.00 2910 2825 2610 3.58 2.34 CX34 49C 6F 4 G71MPP 60C 090 2 49L25 Down Flow Indoor Coils Down Flow Coils 33,800 35,200 21,400 13.0 11.00 7.70 6.70 3075 2980 2730 3.46 2.30 3 CR33 48B/C F 2 49L25 34,800 35,600 21,600 13.0 11.00 7.70 6.70 3165 2875 2655 3.62 2.38 3 CR33 50/60C F 2 49L25 Down Flow Indoor Coils + Furnaces Down Flow Coils + Furnaces 34,200 34,800 21,000 14.0 12.00 8.20 7.00 2850 2860 2605 3.56 2.36 CR33 48B F 4 G61MPV 36B 045 2 49L25 34,200 34,800 21,000 14.0 12.00 8.20 7.00 2850 2855 2600 3.58 2.36 CR33 48B F 4 G61MPV 36B 070 2 49L25 34,200 34,800 21,000 14.0 12.00 8.20 7.00 2850 2855 2600 3.58 2.36 CR33 48B F 4 G71MPP 36B 070 2 49L25 34,200 34,800 21,000 14.0 12.00 8.20 7.00 2850 2855 2600 3.58 2.36 CR33 48B F 4 G61MPV 36B 071 2 49L25 34,400 34,600 20,800 14.5 12.00 8.20 7.00 2865 2780 2525 3.64 2.42 CR33 48C F 4 G61MPV 36C 090 2 49L25 34,400 34,600 20,800 14.5 12.00 8.20 7.00 2865 2780 2525 3.64 2.42 CR33 48C F 4 G71MPP 36C 090 2 49L25 34,400 34,600 20,800 14.5 12.50 8.20 7.00 2750 2765 2515 3.66 2.42 CR33 48B F 4 G60DFV 36B 090 2 49L25 34,600 34,800 21,000 14.5 12.00 8.20 7.20 2885 2770 2535 3.68 2.42 CR33 48C F 4 G61MPV 60C 090 2 49L25 34,600 34,800 21,000 14.5 12.00 8.20 7.20 2885 2770 2535 3.68 2.42 CR33 48C F 4 G71MPP 60C 090 2 49L25 35,600 34,600 20,600 15.0 13.00 9.00 7.50 2850 2545 2330 3.98 2.58 CR33 50/60C F 4 G61MPV 36C 090 2 49L25 35,600 34,600 20,600 15.0 13.00 9.00 7.50 2850 2545 2330 3.98 2.58 CR33 50/60C F 4 G71MPP 36C 090 2 49L25 36,000 35,000 20,800 15.0 13.00 9.00 7.50 2880 2545 2340 4.04 2.60 CR33 50/60C F 4 G61MPV 60C 090 2 49L25 36,000 35,000 20,800 15.0 13.00 9.00 7.50 2880 2545 2340 4.04 2.60 CR33 50/60C F 4 G71MPP 60C 090 2 49L25 Horizontal Indoor Coils Horizontal Coils 35,000 35,200 21,400 13.0 11.00 7.70 6.70 3180 3015 2795 3.42 2.24 3 CH33 44/48B 2F 2 49L25 35,200 35,000 21,200 13.0 11.00 7.70 6.70 3200 3050 2815 3.36 2.20 3 CH33 43C 2F 2 49L25 35,400 35,200 21,400 13.0 11.00 7.70 6.70 3220 3020 2800 3.42 2.24 3 CH33 50/60C 2F 2 49L25 35,600 35,200 21,400 13.0 11.00 7.70 6.70 3235 2995 2770 3.44 2.26 3 CH33 43B 2F 2 49L25 35,600 35,200 21,400 13.0 11.00 7.70 6.70 3235 3020 2800 3.42 2.24 3 CH33 49C 2F 2 49L25 Ratings 95 F outdoor air temperature and 80 F db/67 F wb entering indoor coil air. Temperature Heating Ratings 47 F db/43 F wb outdoor air temperature and 70 F db entering indoor coil air. Temperature Heating Ratings 17 F db/15 F wb outdoor air temperature and 70 F db entering indoor coil air. 14HPX 1.5 to 5 Ton Heat Pump / Page 15

Heating Heating 14HPX 036 Horizontal Indoor Coils + Furnaces Horizontal Coils + Furnaces 35,200 34,800 21,000 14.0 12.00 8.20 6.70 2935 2930 2705 3.48 2.28 CH33 44/48B 2F 4 G61MPV 36B 045 2 49L25 35,200 34,800 21,000 14.0 12.00 8.20 6.70 2935 2920 2700 3.50 2.28 CH33 44/48B 2F 4 G61MPV 36B 070 2 49L25 35,200 34,800 21,000 14.0 12.00 8.20 6.70 2935 2920 2700 3.50 2.28 CH33 44/48B 2F 4 G71MPP 36B 070 2 49L25 35,200 34,800 21,000 14.0 12.00 8.20 6.70 2935 2920 2700 3.50 2.28 CH33 44/48B 2F 4 G61MPV 36B 071 2 49L25 35,400 34,600 20,800 15.0 12.50 8.20 7.00 2830 2835 2625 3.58 2.32 CH33 44/48B 2F 4 G60UHV 36B 090 2 49L25 35,600 34,600 20,800 14.5 12.50 8.00 6.70 2850 2925 2685 3.46 2.26 CH33 43C 2F 4 G61MPV 36B 071 2 49L25 35,800 35,000 21,200 14.5 12.00 8.20 6.70 2985 2910 2680 3.52 2.32 CH33 43B 2F 4 G61MPV 36B 045 2 49L25 36,000 34,400 20,600 15.0 12.50 8.20 7.00 2880 2820 2595 3.58 2.32 CH33 50/60C 2F 4 G61MPV 36C 090 2 49L25 36,000 34,400 20,600 15.0 12.50 8.20 7.00 2880 2820 2595 3.58 2.32 CH33 50/60C 2F 4 G71MPP 36C 090 2 49L25 36,000 34,600 20,600 15.0 12.50 8.20 7.00 2880 2820 2600 3.60 2.32 CH33 49C 2F 4 G61MPV 36C 090 2 49L25 36,000 34,600 20,600 15.0 12.50 8.20 7.00 2880 2820 2600 3.60 2.32 CH33 49C 2F 4 G71MPP 36C 090 2 49L25 36,000 35,000 21,000 14.5 12.50 8.20 7.00 2880 2900 2670 3.54 2.30 CH33 43B 2F 4 G61MPV 36B 070 2 49L25 36,000 35,000 21,000 14.5 12.50 8.20 7.00 2880 2900 2670 3.54 2.30 CH33 43B 2F 4 G71MPP 36B 070 2 49L25 36,200 34,800 20,800 15.0 12.50 8.20 7.00 2895 2805 2600 3.64 2.34 CH33 50/60C 2F 4 G61MPV 60C 090 2 49L25 36,200 34,800 20,800 15.0 12.50 8.20 7.00 2895 2805 2600 3.64 2.34 CH33 50/60C 2F 4 G71MPP 60C 090 2 49L25 36,200 34,800 21,000 15.0 12.50 8.20 7.00 2895 2815 2595 3.62 2.36 CH33 43B 2F 4 G60UHV 36B 090 2 49L25 36,400 34,800 20,800 15.0 12.50 8.20 7.00 2910 2800 2600 3.64 2.34 CH33 49C 2F 4 G61MPV 60C 090 2 49L25 36,400 34,800 20,800 15.0 12.50 8.20 7.00 2910 2800 2600 3.64 2.34 CH33 49C 2F 4 G71MPP 60C 090 2 49L25 14HPX 042 42,500 45,000 27,800 14.0 12.00 8.00 7.20 3540 3890 3540 3.40 2.30 4 CBX32M 048 (Multi Position) 2 49L25 3 TON 3.5 TON 42,500 45,500 28,200 14.0 12.00 8.20 7.20 3540 3650 3320 3.66 2.48 5 CBX26UH 042 (Up Flow / Horizontal) Factory TXV 43,500 44,500 27,400 15.0 12.50 8.20 7.20 3480 3735 3405 3.50 2.36 4 CBX27UH 042 (Up Flow / Horizontal) Factory TXV 43,500 44,500 27,600 14.5 12.50 8.20 7.20 3480 3785 3465 3.44 2.34 4 CBX32MV 048 (Multi Position) 2 49L25 Up Flow Indoor Coils Up Flow Coils 41,500 42,000 27,000 13.0 11.00 7.70 6.70 3775 3440 3145 3.58 2.52 3 CX34 60D 6F 2 49L25 42,000 42,000 26,800 13.0 11.00 7.70 6.70 3820 3475 3165 3.54 2.48 3 CX34 49C 6F 2 49L25 42,000 42,000 27,000 13.0 11.00 7.70 6.70 3820 3435 3120 3.58 2.54 3 CX34 62D 6F 2 49L25 42,500 42,500 27,200 13.0 11.00 7.70 6.70 3865 3350 3060 3.72 2.60 3 CX34 62C 6F 2 49L25 Up Flow Indoor Coils + Furnaces Up Flow Coils + Furnaces 42,000 41,000 26,000 15.0 12.50 8.50 7.70 3360 3230 2915 3.72 2.62 CX34 49C 6F 4 G60UHV 60C 090 2 49L25 42,000 41,000 26,000 15.0 13.00 9.00 7.70 3360 3165 2865 3.80 2.66 CX34 60D 6F 4 G60UHV 60D 135 2 49L25 42,000 41,000 26,200 14.5 12.00 8.20 7.50 3500 3310 2990 3.64 2.56 CX34 49C 6F 4 G61MPV 60C 091 2 49L25 42,000 41,500 26,200 14.5 12.00 8.20 7.50 3500 3285 2975 3.70 2.58 CX34 49C 6F 4 G61MPV 60C 090 2 49L25 42,000 41,500 26,200 14.5 12.00 8.20 7.50 3500 3285 2975 3.70 2.58 CX34 49C 6F 4 G71MPP 60C 090 2 49L25 Up Flow Indoor Coils + Furnaces Continued on Next Page Ratings 95 F outdoor air temperature and 80 F db/67 F wb entering indoor coil air. Temperature Heating Ratings 47 F db/43 F wb outdoor air temperature and 70 F db entering indoor coil air. Temperature Heating Ratings 17 F db/15 F wb outdoor air temperature and 70 F db entering indoor coil air. 5 Most popular air handler combination. 14HPX 1.5 to 5 Ton Heat Pump / Page 16

Heating Heating 14HPX 042 Up Flow Indoor Coils + Furnaces (Continued) Up Flow Coils + Furnaces 42,000 41,500 26,400 14.0 12.00 8.20 7.50 3500 3315 3010 3.66 2.56 CX34 49C 6F 4 G61MPV 36C 090 2 49L25 42,000 41,500 26,400 14.0 12.00 8.20 7.50 3500 3315 3010 3.66 2.56 CX34 49C 6F 4 G71MPP 36C 090 2 49L25 42,500 41,000 26,200 14.5 12.00 8.50 7.70 3540 3250 2945 3.70 2.60 CX34 49C 6F 4 G60UHV 60C 110 2 49L25 42,500 41,000 26,200 15.0 13.00 9.00 7.70 3400 3160 2875 3.80 2.66 CX34 62D 6F 4 G60UHV 60D 135 2 49L25 42,500 41,500 26,200 14.5 12.00 8.50 7.70 3540 3195 2920 3.80 2.62 CX34 60D 6F 4 G61MPV 60D 135 2 49L25 42,500 41,500 26,200 14.5 12.00 8.50 7.70 3540 3195 2920 3.80 2.62 CX34 60D 6F 4 G71MPP 60D 135 2 49L25 42,500 41,500 26,200 15.0 13.00 9.00 7.70 3400 3190 2915 3.82 2.64 CX34 62D 6F 4 G61MPV 60D 135 2 49L25 42,500 41,500 26,200 15.0 13.00 9.00 7.70 3400 3190 2915 3.82 2.64 CX34 62D 6F 4 G71MPP 60D 135 2 49L25 42,500 41,500 26,200 14.5 12.00 8.20 7.50 3540 3265 2960 3.72 2.60 CX34 49C 6F 4 G61MPV 60C 110 2 49L25 42,500 41,500 26,200 14.5 12.00 8.20 7.50 3540 3265 2960 3.72 2.60 CX34 49C 6F 4 G71MPP 60C 110 2 49L25 42,500 41,500 26,200 14.5 12.00 8.20 7.50 3540 3275 2970 3.72 2.58 CX34 49C 6F 4 G61MPV 60C 111 2 49L25 42,500 41,500 26,400 14.5 12.00 8.50 7.70 3540 3180 2885 3.82 2.68 CX34 62C 6F 4 G61MPV 60C 091 2 49L25 43,000 41,500 26,200 15.0 13.00 9.00 8.00 3440 3105 2810 3.92 2.74 CX34 62C 6F 4 G60UHV 60C 090 2 49L25 43,000 41,500 26,400 15.0 13.00 9.00 7.70 3440 3130 2840 3.88 2.72 CX34 62C 6F 4 G60UHV 60C 110 2 49L25 43,000 42,000 26,600 15.0 12.50 8.50 8.00 3440 3140 2880 3.92 2.70 CX34 62C 6F 4 G61MPV 60C 110 2 49L25 43,000 42,000 26,600 15.0 12.50 8.50 8.00 3440 3140 2880 3.92 2.70 CX34 62C 6F 4 G71MPP 60C 110 2 49L25 43,000 42,000 26,600 14.5 12.00 8.50 7.70 3585 3190 2905 3.86 2.68 CX34 62C 6F 4 G61MPV 36C 090 2 49L25 43,000 42,000 26,600 14.5 12.00 8.50 7.70 3585 3190 2905 3.86 2.68 CX34 62C 6F 4 G71MPP 36C 090 2 49L25 43,000 42,000 26,400 14.5 12.00 8.50 7.70 3585 3160 2870 3.90 2.70 CX34 62C 6F 4 G61MPV 60C 090 2 49L25 43,000 42,000 26,400 14.5 12.00 8.50 7.70 3585 3160 2870 3.90 2.70 CX34 62C 6F 4 G71MPP 60C 090 2 49L25 43,000 42,000 26,600 15.0 12.50 8.50 8.00 3440 3150 2895 3.90 2.70 CX34 62C 6F 4 G61MPV 60C 111 2 49L25 Down Flow Indoor Coils Down Flow Coils 41,500 42,500 27,200 13.0 11.00 7.70 6.70 3775 3340 3055 3.72 2.60 3 CR33 50/60C F 2 49L25 41,500 42,500 27,200 13.0 11.00 7.70 6.70 3775 3340 3055 3.72 2.60 3 CR33 60D F 2 49L25 Down Flow Indoor Coils + Furnaces Down Flow Coils + Furnaces 41,500 41,500 26,200 14.5 12.00 8.50 8.00 3460 3100 2805 3.92 2.74 CR33 50/60C F 4 G60DFV 60C 110 2 49L25 41,500 41,500 26,200 14.5 12.00 8.50 8.00 3460 3085 2790 3.94 2.74 CR33 60D F 4 G60DFV 60D 135 2 49L25 41,500 41,500 26,400 14.0 12.00 8.50 7.70 3460 3170 2875 3.84 2.68 CR33 50/60C F 4 G61MPV 60C 091 2 49L25 41,500 42,000 26,400 14.5 12.00 8.50 7.70 3460 3150 2860 3.90 2.70 CR33 50/60C F 4 G61MPV 60C 090 2 49L25 41,500 42,000 26,400 14.5 12.00 8.50 7.70 3460 3150 2860 3.90 2.70 CR33 50/60C F 4 G71MPP 60C 090 2 49L25 41,500 42,000 26,600 14.0 12.00 8.50 7.70 3460 3180 2895 3.88 2.70 CR33 50/60C F 4 G61MPV 36C 090 2 49L25 41,500 42,000 26,600 14.0 12.00 8.50 7.70 3460 3180 2895 3.88 2.70 CR33 50/60C F 4 G71MPP 36C 090 2 49L25 42,000 41,500 26,200 14.5 12.00 8.50 8.00 3500 3080 2795 3.94 2.74 CR33 50/60C F 4 G60DFV 60C 090 2 49L25 42,000 41,500 26,400 14.5 12.00 8.50 8.00 3500 3095 2815 3.92 2.74 CR33 60D F 4 G61MPV 60D 135 2 49L25 42,000 41,500 26,400 14.5 12.00 8.50 8.00 3500 3095 2815 3.92 2.74 CR33 60D F 4 G71MPP 60D 135 2 49L25 42,000 42,000 26,400 14.5 12.00 8.50 8.00 3500 3125 2845 3.94 2.72 CR33 50/60C F 4 G61MPV 60C 110 2 49L25 42,000 42,000 26,400 14.5 12.00 8.50 8.00 3500 3125 2845 3.94 2.72 CR33 50/60C F 4 G71MPP 60C 110 2 49L25 42,000 42,000 26,600 14.5 12.00 8.50 8.00 3500 3140 2860 3.92 2.72 CR33 50/60C F 4 G61MPV 60C 111 2 49L25 3.5 TON Ratings 95 F outdoor air temperature and 80 F db/67 F wb entering indoor coil air. Temperature Heating Ratings 47 F db/43 F wb outdoor air temperature and 70 F db entering indoor coil air. Temperature Heating Ratings 17 F db/15 F wb outdoor air temperature and 70 F db entering indoor coil air. 14HPX 1.5 to 5 Ton Heat Pump / Page 17