INTRODUCTION. Heat Pipe Technology, Inc. The Heat Pipe Principle. Recent Heat Pipe Development

Similar documents
Controlling Wrap-Around Heat Pipes for Systems with Strict Space Humidity Requirements. By Michael O. Davis, PE, August 2015

Energy Recovery Ventilation

ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS

REFRIGERANT AND WATER HEAT PIPES D E H U M I D I F I C A T I O N

Heat Recovery Units. Heat Recovery 1

product application data PERFECT HUMIDITY DEHUMIDIFICATION SYSTEM

Enriching Environments

Our energy efficient experts and engineers have made ground breaking innovations in this field.

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

Heat pump and energy recovery systems

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

CHAPTER 4. HVAC DELIVERY SYSTEMS

100% Outdoor Air Dehumidification Methods

The ultimate fresh air solution.

HI-EDRY HI-EDRY THE HIGH-EFFICIENCY DEHUMIDIFIERS. Therma-Stor Products THE HIGH-EFFICIENCY DEHUMIDIFIER. a division of DEC International, Inc.

T H E H I G H - E F F I C I E N C Y D E H U M I D I F I E R S THE HIGH-EFFICIENCY DEHUMIDIFIER

Complete Ventilation, Heat Recovery and Dehumidification Packaged System by. Maintaining Your Climate for Indoor Pools and Waterparks

Principles of Mechanical Refrigeration

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

Adsorption Chillers Energysmart Green Cooling

Air-Cooling Evaporators

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

Air Conditioning Refrigeration Electrical Work TEL: 0(204) (254)

Commercial/Industrial Products. Partnerships beyond metals

By Thomas H. Durkin, P.E., Member ASHRAE, and James B. (Burt) Rishel, P.E., Fellow/Life Member ASHRAE

COMcheck Software Version Mechanical Compliance Certificate

Closed Circuit Cooling Towers

Product Release Summary

Heat sinks for electronic cooling applications

Trane Performance Climate Changer Air Handlers. An air handler for every need.

Heat Pump Water Heaters

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

Are uncontrollable humidity problems costing you a bundle?

FIRE SUPPRESSION SYSTEM

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Trane CDQ Desiccant Dehumidification

Daikin Blueprint: Delivering Hot Water with a Chiller

ABOUT US OUR EXPERTISE WHAT IS ENERGY RECOVERY? ERV (Energy Recovery Ventilation) AHU (Air Handling Units) PAC (Package Air Conditioning Equipment)

HEAT PIPES

Trane Performance Climate Changer Air Handlers. An air handler for every need.

REPRODUCTION/DISTRIBUTION IS PROHIBITED. Energy-Savings Strategies for. Rooftop

SAFETY AND ENVIRONMENTAL EDUCATION FOR DEVELOPMENT SEED

ASHRAE Standard 90.1 Energy Requirements Wrap-Around Heat Pipes

USER S GUIDE. For all Packaged Systems (Air Conditioners and Heat Pumps)

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

RT-OA TM Rooftop Outdoor-Air (DOAS)

healthy comfort Indoor Air Quality Solutions

Saving Energy and the Environment with the latest developments in Heat Pipe Technology

HEAT PIPE IMPACT ON DEHUMIDIFICATION, INDOOR AIR QUALITY AND ENERGY SAVINGS

Innovative and energy efficient humidity control. Peter Lau Application Manager Ingersoll Rand

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

To Keep Docs Cool, Dry and Happy

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

THERMAL ICE STORAGE: Application & Design Guide

Dehumidification: Energy Efficiency Comparisons

PPL Electric Utilities Energy Efficiency and Conservation Program

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Controlling Indoor Humidity in High Performance Homes. Danny Gough, Energy Solutions, LP

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

Custom Performance Climate Changer air handlers. Expertly designed and built to meet your specific requirements

The Energy Mist System

Heat Pumps and Public Swimming Pools, a Perfect Match

Benefits Offered by Passive Dehumidification Wheel Speed Control

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

USOO A United States Patent (19) 11 Patent Number: 5,921,315 Dinh (45) Date of Patent: *Jul. 13, 1999

PRODUCT OVERVIEW. Dehumidifiers

Review of Thermosyphon heat exchanger charged with hybrid nanofluid for waste heat recovery applications

Efficiency Vermont The American Institute of Architects Continuing Education Systems (AIA/CES) AIA/CES AIA/CES

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

2009 IECC Commercial Mechanical Requirements

Active desiccant integration with packaged rooftop HVAC equipment

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

HVAC DISTRIBUTION and DELIVERY SYSTEMS

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT HVAC MAINTENANCE TECHNOLOGY. Test Code: 5937 Version: 01

2011 Manitoba Energy Code for Buildings (MECB) PART 5, Heating, Ventilating and Air-conditioning Systems

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

Heat Pipe Applications Introduce

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

healthy comfort Indoor Air Quality Solutions

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

Welcome to the World of Aavid Heat Pipes

Greensource iseries Water Source Heat Pumps. SV Model. Made in Florida boschheatingandcooling.com

Commercial and Industrial Applications

Energy recovery from exhaust gases using Heat Pipe technology

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

Energy Recovery with Cooling and Heating Model ERCH

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

DES CHAMPS PRODUCTS 85% 4,400 CFM

High Efficiency Heating and Cooling Systems for Community Colleges Kirk Mescher, PE, LEED AP Principal ICCCFO

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

CAIRfricostar CAU Controller with Remote Control SUPPLEMENT TO OPERATION MANUAL

Transcription:

INTRODUCTION Heat Pipe Technology, Inc. Heat Pipe Technology, Inc. (HPT) was founded in 1983. With funding from private investors, and a grant from the Department of Energy. HPT began research on a new use for heat pipes, a passive heat transfer device previously used in many various applications ranging from orbiting satellites to the Alaskan Pipeline ground spikes. By applying heat pipes to standard air conditioning coil systems, the dehumidification performance and efficiency was greatly enhanced, with no increase in energy use. Projects to follow proved the technology could be applied on any scale, while being commercially viable and practical to implement. While humidity control became a widely recognized requirement for indoor air quality in all modern buildings, heat pipes were proving to be one of the most cost effective and efficient methods of dehumidification in the world. With a staff of talented mechanical engineers and a specialized team of installation experts, HPT began installing patented HPT Dehumidifier Heat Pipes at thousands of locations around the world. The client list grew to include many high profile locations such as Walt Disney World, The Kennedy Space Center and the Salvador Dali Museum, as well as data centers, numerous restaurant chains, premier hotels, and many prestigious universities. Applications have ranged from 2 to 500 ton systems. Today, HPT manufactures heat pipes for dehumidification and energy recovery for many diverse HVAC applications in addition to the custom and retrofit designs. As of January 2017, HPT is represented worldwide by 56 independent representatives in over 100 locations, (many representatives have multiple offices). Call for the name of a representative in your area: (813) 470-4250, or log on to our website at www.heatpipe.com. The Heat Pipe Principle Having first been invented near the turn of the 20 th century, the heat pipe is not in itself a new invention. Early heat pipes were constructed out of hollow metal tubes that were sealed at both ends, vacuumed, and charged with a small quantity of evaporative fluid. They contained a "wick" to transport the fluid from one end of the heat pipe to the other. Relying on the energy absorbed and released from the phase change of the fluid, the hollow heat pipe allowed an extremely fast heat transfer. Heat applied to one end of the pipe would almost instantaneously evaporate the fluid inside. This vapor would then move to the other, colder end of the pipe where it quickly condensed back into a liquid, releasing the heat absorbed during the evaporation. Recent Heat Pipe Development Modern heat pipes are able to transfer heat several hundred times faster than a solid copper rod. However, the applications for heat pipes have been limited in the past due to their construction expense. The requirement for separate pipes and interior capillary wicks has traditionally kept the cost of heat pipes too high for all but the most exotic applications. Additionally, wick materials did not last very long. INTR-1

Heat Pipe Technology, Inc., revolutionized the construction of heat pipes in the early 1980's and HPT was granted the first of several heat pipe patents in 1986. The methods that were developed brought the cost of the company's patented heat pipes down to a commercially affordable level. The patent also disclosed a new and previously undiscovered use for heat pipes, namely, using them to increase the efficiency and dehumidification capability of air conditioning systems. The Discovery of Heat Pipe Dehumidification In 1983, HPT research engineers conceived a method for applying heat pipes to an air conditioning system. A prototype was built, which included a heat pipe arrangement that would later become the company's patented dehumidification heat pipe technology. The initial testing indicated that the heat pipe dramatically improved the performance of the cooling coil for dehumidification. This research led to a Technology Utilization contract with NASA. The potential of the technology was also recognized by the Department of Energy's (DOE) award in 1991 through a grant for bringing the heat pipe technology to public awareness. Heat Pipes for Dehumidification & Energy Recovery In an air conditioning system, the colder the air becomes as it passes over the cooling coil, the more moisture is condensed out. HPT heat-pipes wrap around the cooling coil, with one part of the heat pipe in the return air stream and the other part in the supply air stream. Warm incoming air is precooled by the evaporator (precool) section of the heat pipes. The air is then cooled further (overcooled) by the cooling coil for more moisture extraction. Next, air is passively heated back up by the condenser (reheat) section of the heat pipes to lower the relative humidity. The leaving air from the heat pipe system now has much lower moisture content and lower relative humidity. While consuming no energy, except for the small static pressure increase, the heat pipe precooling effect allows the cooling coil to operate at a lower temperature, considerably increasing the moisture removal capabilities of the system. With lower humidity, the indoor air becomes more comfortable at higher thermostat settings, resulting in net energy savings. Heat pipes are also used to recover energy as heat exchanger between supply and exhaust air streams. With no moving parts and no tilt mechanism needed, HPT energy recovery modules have a distinct advantage over the competitors and other technologies. INTR-2

The Markets for Heat Pipe Technology HPT's advances in heat pipes have opened many large markets with a wide variety of applications. The commercial and industrial applications include, but are not limited to, medical and health facilities, data centers, schools, supermarkets, restaurants, libraries and archives, warehouses, hotels, public and commercial buildings, and high-tech facilities. In 1989, the company began designing and installing commercial heat pipe systems used for dehumidification and passive cooling. Early installations included cooling systems for government radar and satellite tracking stations, heat recovery for buildings using outside air, and resolution of building humidity problems. By 1990, the company had discovered the huge market that exists for commercial HVAC dehumidification systems. The company began performing market research and working closely with a number of utility companies, specifying engineers, and national restaurant chains to install, test and monitor the heat pipes. The results were very favorable and the technology became the centerfold of numerous presentations at workshops and seminars. Since then, the growth of heat pipe acceptance has become apparent with numerous installations. After 2009, HPT s major market moves to health care, education, and data centers applications.. Opportunities in Commercial Applications There are many applications for the company's patented technology. Commercial markets are extremely receptive to the dehumidification products and heat recovery products. Below is a listing of some the commercial applications for HPT Dehumidifier and Heat Recovery Heat Pipes. Cleanrooms Data Centers Educational Facilities Electronics Assembly Pharmaceutical Manufacturing Food Manufacturers Museums/Archives Office Buildings Supermarkets Swimming Pool Enclosures Textile Manufactures Warehouses Hospitals Hotel/Motel Laboratories Libraries Airport Facilities Bus Garages INTR-3

HEAT PIPES FOR DEHUMIDIFICATION and HEAT RECOVERY Overview Heat pipes are the most effective passive method of transferring heat available today. In their simplest form, a heat pipe is a sealed tube containing a phase-change fluid. The heat pipes for HVAC applications are usually made of copper tubes, aluminum fins.. Different working fluids are used to suit various temperature ranges. In the case of heat pipes for HVAC applications, commercially available refrigerants are normally used as the working fluid. When there is temperature difference in two air streams of each end of the heat pipes, hot air stream applied to one end of the heat pipe, heat boils the inside fluid causing it to change phase from liquid to gas. This vaporization process absorbs large amounts of heat from hot the air stream. Vapor then travels to the other end of the heat pipe, where another air stream with the lower temperature causes the working fluid to condense and release the heat to the cold airflow. Fluid return is normally accomplished by gravity. The constant circulation of evaporating and condensing of the working fluid is the principle of heat pipes heat transfer. Heat pipes can transfer heat with minimal temperature difference between one end and the other. Passive HPT heat pipes do not need a circulating pump to operate and have no operating cost except for a nominal increase in static pressure. They have no moving parts to malfunction or to be maintained. Basic Heat Pipe Structure Diagram C A traditional heat pipe is a hollow cylinder filled with a vaporizable liquid. D A. Heat is absorbed in the evaporating section. B. Fluid boils to vapor phase. C. Heat is released from the upper part of cylinder to the environment; vapor condenses to liquid phase. B D. Liquid returns by gravity or capillarity to the evaporating section. A INTR-4

HEAT PIPES AND AIR CONDITIONING Below illustrations show how wrap around heat pipes replace the old overcool then reheat method used to extract more moisture from an air stream. Current ASHRAE standard 90.1 does not allow simultaneous cooling and heating unless 75% of the energy used for reheat is a site recovered energy. In the case of the wrap around heat pipes, all reheat energy is site recovered. Moreover, the reheat is captured from incoming air stream, thus reducing the load on the cooling coil. Current ASHRAE standards refer to wrap around heat pipes as energy recovery in series. Air Conditioning in a Hot and Humid Climate Standard Hot and Humid Air Saturated Air Some Moisture Overcooling to Remove Excess Humidity Over Sized Hot and Humid Air Over-Cooled Air More Moisture Reheating Overcooled Air to Comfortable Condition Over Sized Heater Hot and Humid Air Over-Cooled Drier and Comfortable Air More Moisture INTR-5

Using Heat Pipes to Improve Efficiency / Moisture Removal Capacity Drier and Comfortable Air Over-Cooled Air Standard Hot and Very Humid Air Heat Pipe More Moisture Dehumidifier Heat Pipe Principle INTR-6

Heat Pipe Dehumidification Precool Reheat 80 F/70%RH 70 F 50 F/95%RH 60 F/65%RH Increased Condensate Note: The above diagram shows only one circuit. Typically heat pipe systems are comprised of multiple circuits. Actual heat pipe installations may differ from the above. INTR-7