Heat Recovery Units. Heat Recovery 1

Similar documents
Heat pump and energy recovery systems

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

CHAPTER 4. HVAC DELIVERY SYSTEMS

Review on Waste Heat Recovery Techniques in Air Conditioning Application

White Paper. Executive Summary. Overview of Membrane Exchangers CLCH-PRB063A-EN. June 2017

Section 4 of 6 DOAS Core Technologies

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

AHRI Guideline W (I-P) 2014 Guideline for Selecting, Sizing, & Specifying Packaged Air-to-Air Energy Recovery Ventilation Equipment

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

EU Air Handling Units with SEMCO EXCLU-SIEVE

A according to their application as (1) process-to-process, (2)

AIR HANDLING THERMAL CONDITIONS

COMMERCIAL HVAC EQUIPMENT Coils: Direct Expansion, Chilled Water, and Heating

Climate Control System

Bill McCullough. Director ERV Products. Dallas, TX

ASHRAE Standard 90.1 Energy Requirements Wrap-Around Heat Pipes

Energy Recovery Ventilation

Technical college/ Baghdad 4th Year Week No. :- 11. The objectives of this lesson are to: Introduction:

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

15. Heat Pipes in Electronics (1)

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

1998 Expedition/Navigator Workshop Manual

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Adding More Fan Power Can Be a Good Thing

Principles of Active Desiccant Operation. Presented by Tom Peterson, CEO and Founder. Climate by Design International

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Service Step by Step Trouble-Shooting Check-List

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

B. Unit shall be shipped as a single package unless the unit is too large to fit on a standard tractor-trailer.

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

Tech to Tech May 07 HRV s & ERV s

RT-OA TM Rooftop Outdoor-Air (DOAS)

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

By MIKE WEST, PHD, PE Advantek Consulting Inc. Melbourne, Fla.

... DF / IDF Gas fired combined heating and ventilation ...

Submittal Data Performance Data Electrical Data

DF-IDF air handling units

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

RSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

DES CHAMPS PRODUCTS 85% 4,400 CFM

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

100% Outdoor Air Dehumidification Methods

WORKSHOP VENTILATION- PSYCHROMETRICS-AHU

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS

Summary Comparison of Simulation Program Features

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

Enthalpy Wheel and its Application in Air Conditioning

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

HEAT PIPES DEHUMIDIFICATION &

Appendix 13. Categories of Cooling and Heating systems

Benefits Offered by Passive Dehumidification Wheel Speed Control

Technical Development Program

Oxyvap Evaporative Cooling Applications

College of Technological Studies Department of Power & Refrigeration Technology. Course Contents

INTRODUCTION. Heat Pipe Technology, Inc. The Heat Pipe Principle. Recent Heat Pipe Development

Pharmaceutical Facility Design

COMcheck Software Version Mechanical Compliance Certificate

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

Moisture can be very disruptive to a dust. Preventing moisture problems in your dust collector

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

Chilled beams. TRACE 700 incorporates two chilled beam strategies: passive and active.

SEQUENCE OF OPERATIONS

REFRIGERANT AND WATER HEAT PIPES D E H U M I D I F I C A T I O N

The ultimate fresh air solution.

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

b.) Technical Information:

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

CTI Sponsored Educational Program

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Series VENTS VUT R WH ЕС

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

VERSO Air Handling Units

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Trane CDQ Desiccant Dehumidification

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Air is our element. energy recovery our passion. Rotors overview. Quick guide GOST VDI 6022

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

Air Conditioning Clinic

ENCLOSURE COOLING. Glossary

Wall Mounted Air Conditioners with Gas Heat Models AVGA

HEAT EXCHANGERS. Heat exchangers are broadly classified based on the following considerations.

Energy Recovery with Cooling and Heating Model ERCH

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SECTION (15733) - DEDICATED OUTDOOR AIR UNITS

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

AHU Air Handling Unit Fundamentals. j.ilangumaran

Product Release Summary

ENERGY MANAGEMENT IN MILK POWDER PLANTS

Energy Recovery with Cooling and Heating

Transcription:

Heat Recovery Units Heat Recovery 1

Heat Recovery Unit Why? A heat recovery unit (HRU) can help make mechanical ventilation more cost effective by reclaiming energy from exhaust airflows. HRUs use air-to-air heat exchangers to heat or cool incoming fresh air, recapturing 40 to 85 percent of the conditioned temperatures and/or that would otherwise be lost.

Heat Recovery Unit Classifying by energy and material transport HRU Recuperative Regenerative Only heat energy transport (sensible heat) Heat energy and moisture transport (Total energy recovergy: sensible + latent energy) - Fixed-plate heat exchanger (cross flow) - Heat pipe - Coil energy recovery loop - Rotary heat exchnager (also known as sensible-energy wheel or heat wheel ) - Rotary Exchanger (also known as total-energy wheel or enthaly wheel )

Heat Recovery Unit Classifying by system bulid-up HRU Air To Air transport Transmitting medium - Fixed-plate heat exchanger (cross flow) - Coil Energy Recovery Loop - Heatpipe - Rotary Exchanger

Heat Recovery 5

Heat Recovery 6

Procedure for determination of energy recovered in air-to-air energy recovery applications: Heat Recovery 7

FIXED-PLATE EXCHANGERS Heat Recovery 8

Heat Recovery Unit Plate, cross-flow heat exchanger - Separated airstreams, no leakage between airstreams The heat exchanger package consists of aluminium plates provided with spacers and arranged at right angles to one another. This produces a large numbers of air passages. Frosting can be controlled by: - preheating incoming supply air - bypassing part of the incoming air - temporarily interrupting supply air

FIXED-PLATE EXCHANGERS Fixed surface plate exchangers have no moving parts. Alternate layers of plates, separated and sealed (I.e. the heat exchanger core), form the exhaust and supply airstream passages. Plate spacings range from 2.5 to 12.5 mm Heat is transferred directly from the warm airstreams through the separating plates into the cool airstreams. Heat Recovery 10

FIXED-PLATE EXCHANGERS Design and construction restrictions cross-flow heat transfer Additional effective heat transfer surface arranged properly into counter flow patterns can increase heat transfer effectiveness. Latent heat of condensation = moisture condensed as the temperature of the warm (exhaust) air stream drops below its dew point Latent heat of condensation and sensible heat are conducted through the separating plates into the cool (supply) air stream. Outside air Moisture is not transferred. Counter flow Heat Exchanger Recovering min. 80% of available waste exhaust. Heat Recovery 11

FIXED-PLATE EXCHANGERS Capacity Control Face-and-bypass dampers for control the capacity of a fixed-plate heat exchanger Face dampers closed + Linked bypass dampers open to reduce airflow Face-and-bypass dampers avoid overheating the supply air by reducing the amount of heat transfer that occurs in the heat exchanger. Heat Recovery 12

FIXED-PLATE EXCHANGERS Frost Prevention Frost is most likely to develop in the corner of the heat exchanger Cold entering outdoor air recovers heat from the exhaust air on the leaving edge of the heat exchanger. In this corner, exhaust air is in contact with the coldest surface of the heat exchanger, which approximates the entering outdoor-air condition. This means that frost will form when the outdoor air drops below 0 C. Heat Recovery 13

Heat Recovery 14

ROTARY AIR-TO-AIR ENERGY EXCHANGERS A rotary air-to-air energy exchanger, or rotary enthalpy wheel, has a revolving cylinder filled with an air-permeable medium having a large internal surface area. Adjacent supply and exhaust airstreams each flow through one-half the exchanger in a counterflow pattern. Heat transfer media may be selected to recover sensible heat only or total heat (sensible heat plus latent heat). A desiccant film coating on wheel surfaces absorbs moisture (wheel at more humid airstream). Moist desorbed from film less humid airstream. Heat Recovery 15

Sensible heat The medium picks up and stores heat from the hot air stream and releases it to the cold on. Latent heat 1. The medium condenses moisture from the airstream with the higher humidity ratio (medium temperature <dew point or by desiccants ) 2. Releases the moisture through evaporation (and heat pickup) into the air stream with the lower humidity ratio. Heat Recovery 16

Cross-Contamination Carryover Air entrained within the volume of the rotation medium is carried into the other air stream. Leakage Differential static pressure across two airstreams drives air from a higher to a lower static pressure region. A purge section can be installed on the heat exchanger to reduce cross-contamination. Heat Recovery 17

Regulation of wheel energy recovery: Supply air bypass control An air bypass damper, controlled by a wheel supply air discharge temperature sensor, regulates the proportion of supply air bypassing exchanger. Varying wheel rotational speed - variable- speed drives (1) A silicon controlled rectifier (SCR) with variable-speed dc motor, (2) A constant speed ac motor with hysteresis coupling, (3) An ac frequency inverter with an ac induction motor. Comparison - Exhaust Air Bypass preferred Exhaust-air bypass a more linear unloading characteristic than a VFD (stable control) Exhaust-air bypass wider range of capacity control. Heat Recovery 18

Coil Loops Heat Recovery 19

Coil Loops Heat Recovery 20

Coil Loop Construction and properties of a Coil Loop Heat Recovery System: Two or more finned-tube coils that are piped together in a closed loop A small pump circulates the working fluid through the two coils Working fluid - a solution of inhibited glycol and water through the two coils An expansion tank in the system Modulating capacity (three-way mixing valve or a variable-speed drive on the pump) The most flexible - transfer energy between air streams that are physically separated by some distance Recover energy from multiple exhaust-air streams (using multiple exhaust-side coils) Multiple coils - requires additional coils, more piping and glycol (against frosting), and a larger pump. Heat Recovery 21

Coil Loop Typical Performance Coil-loop selections: Sensible effectiveness of 45% to 65 %, balanced airflow, and airside static-pressure loss of 75-250 Pa per coil. Varies number of rows, spacing and type of fins, face velocity, and fluid flow rate for a specific application. Adding more rows and fins to the coils: increases the sensible effectiveness of the coil loop the fan(s) to consume more energy Net energy saved = Energy recovered - additional fan and pump energy. Heat Recovery 22

Coil loop Precondition outdoor air application Coil selections on the lowest possible fluid flow rate and face velocity Higher fluid flow rate increase the sensible effectiveness of the coil loop a larger, more expensive pump and larger piping increase the energy consumption of the pump Heat Recovery 23

Coil Loop Frost Prevention Three-way mixing valve or variable-speed drive to prevent frost formation on the exhaust-side coil. If a temperature sensor detects a fluid temperature that is colder than 0 C, Three-way mixing valve redirects the warm fluid leaving the exhaust-side coil into the fluid returning from the supply-side coil. A variable-speed pump reduce the fluid flow rate through the entire loop. Heat Recovery 24

Heat Recovery 25

Heat Recovery 27

HEAT PIPE HEAT EXCHANGERS A passive energy recovery device With appearance of an ordinary plate-finned water coil Tubes not interconnected Pipe heat exchanger divided into evaporator and condenser by a partition plate. Sensible heat transfer devices Condensation on the fins allow latent heat transfer Heat Recovery 28

Heat pipe tubes are fabricated with an integral capillary wick structure, evacuated, filled with a suitable working fluid and permanently sealed. The working fluid is normally a refrigerant. Fin designs include continuous corrugated plate fin, continuous plain fin, and spiral fins. Modifying fin design and tube spacing changes pressure drop at a given face velocity. Heat Recovery 29

Principle of Operation Hot air flowing over the evaporator end of the heat pipe vaporizes the working fluid. A vapor pressure gradient drives the vapor to the condenser end of the heat pipe tube Vapor condenses at condenser releasing the latent energy of vaporization. The condensed fluid is wicked or flows back to the evaporator, where it is re-vaporized, thus completing the cycle. Heat Recovery 30

Controls Changing the slope (tilt) of a heat pipe controls the amount of heat it transfers. Operating the heat pipe on a slope with the hot end below (or above) the horizontal improves (or retards) the condensate flow back to the evaporator end of the heat pipe. This feature for regulating the effectiveness of the heat pipe heat exchanger. Heat Recovery 31

Cross-Contamination Zero cross-contamination for pressure differentials between airstreams of up to 12 kpa. A vented double-wall partition between the airstreams additional protection against cross-contamination. Exhaust duct attached to the partition space for exhaust of leakage at space between two ducts. Heat Recovery 32

pivot Heat pipes A temperature-controlled actuator to one end of the exchanger for control In practice, tilt control is effected by pivoting the exchanger about the center of its base. Heat Recovery 33

Thank you for your attention!