Dirt and Air Separators

Similar documents
Weatherproof booster and tank system. Weatherproof storage tank, booster set and equipment kiosk

DISCALDIRT deaerator-dirt separator

Function. Pressure Vessel Inspector; CRN registered Sizes 2 4

DOMESTIC COMMERCIAL INDUSTRY AUTOMATIC DEAERATORS/ DIRT SEPARATORS FOR HEATING, COOLING AND PROCESS SYSTEMS

CALEFFI DISCAL. deaerator-dirt separator DISCAL series ACCREDITED 01123/17 GB. replaces dp 01123/14 GB

Zeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

DOMESTIC COMMERCIAL INDUSTRY AUTOMATIC DIRT SEPARATORS FOR HEATING, COOLING AND PROCESS SYSTEMS

Airvec. Deaerators For Heating and Cooling Systems.

NKW. Heater series HEATERS

Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation

Systems for central heating

In-Line Air Separators

CRU 200 and 500 Series Condensate Recovery Units

AIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS

.2 Section Waste Management and Disposal..5 Section Performance Verification of Mechanical Piping Systems.

The Ultimate in Distribution Efficiency. Air Eliminator Dirt Separator Low Loss Header Hydraulic Separator

DirtVec. Dirt Separators For Heating and Cooling Systems.

For commercial & industrial systems. Large volume dirt collection capacity

CALEFFI. SEP4 combination hydraulic, air, dirt and magnetic separator series 01249/13.1 NA. Replaces 01249/13 NA. Function.

DIRTCAL - DIRTMAG dirt separator

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

SXS. CIRCULATING PUMPS FOR COLLECTIVE APPLICATIONS Domestic hot water Bronze housing 2 poles 50 Hz 230 V OPERATING RANGES APPLICATIONS BENEFITS

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Threaded. Flanged. Model PSH. Primary Secondary Header A-451

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

HydroFixx The Manifold with integrated Hydraulic Separator

HYDRAULIC SEPARATION. Product Range

Installation, commissioning and servicing instructions

Lifting Plants Product Overview

High-efficiency circulating pumps Heating Air conditioning 50 Hz

SUNOCO Heat Transfer Fluids

GRUNDFOS DATA BOOKLET MTB. Centrifugal machine tool pumps 50/60 Hz

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

HYDRAULIC OIL COOLER. Installation, Operation & Maintenance Guide

MFP14 Automatic pumps for condensate and other industrial fluids

Fans and Pumps I. Dr. Sam C. M. Hui Department of Mechanical Engineering The University of Hong Kong

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

35% Ultra-efficient brazed heat exchangers for your district energy applications. Up to. Brazed Micro Plate heat exchangers

MFP14 Automatic pumps. for condensate and other industrial fluids

SPIROVENT JUNIOR. Microbubble Separators Dirt Separators Combination Air/Dirt Separators. The Ultimate in Distribution Efficiency

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

Technical data. Unilift KP. CRUNDFOS "~ ozpump.com.au Drainage pumps. Unilift KP

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3

NEW. Hydronic HVAC Systems. FloCon Watchman TM. Patent Numbers: GB , GB , GB Rev: /2015

SECTION PUMPS. 6. Section Steam and Condensate Piping and Specialties.

R146C. Adjustable magnetic dirt separator. Versions and product codes. Datasheet 0840EN 10/2018

PRODUCT OVERVIEW THE BEST WATER QUALITY FOR OPTIMUM PERFOR- MANCE IN HVAC SYSTEMS DOMESTIC COMMERCIAL INDUSTRY SPIRO EXCEPTIONAL GUARANTEE

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

Aegean Range. A new range of fan coils for heating and cooling commercial applications

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

Gasketed and brazed plate heat exchangers

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

Pumps Mixers Aeration Controls Services SCANPUMP SPLIT CASING PUMP Z22.

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

BuildingName The Description of the Project P DOCUMENTS

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

CPM, CPMSP Cascade header kits Installation, Commissioning and Maintenance Instructions

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

SINUS HYDROFIXX THE MANIFOLD WITH INTEGRATED HYDRONIC JUNCTION QUALITY THROUGH EXPERTISE.

Steam Site Guide. Steam Site Guide. Heat Exchange Applications - SI Units

TECHNICAL. Series 18. Pump Packages

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

Filtering Ideas, Making Innovations

CHILLER. Operator s & Installation Manual

STREBEL S-CB + Cascade Kits

Hydraulic Separation Moving Beyond Priamry / Secondary Piping...

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

NON-CYCLING REFRIGERATED AIR DRYERS. RNC Series

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Technical Data Manual Model Nos. and pricing: see Price List

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

2018 PLUMBING AND HYDRONICS CATALOG

EHH SERIES DRAW THROUGH FAN COILS CFM

Manhardt Lindel / ERHARD-Armaturen VALVE & PIPELINE CAVITATION

HYDRAULIC OIL COOLER Installation, Operation & Maintenance Guide

Specially Designed Waste Water & Sewage Pumps

Components for solar heating systems

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Commercial product range

Valves, controls + systems. Innovation + Quality. Stations for solar energy and solid fuel boilers Product range

ANNEX 6. Refinery No. 1 New Area. Problems Existing in the Current Condensate Return System of the New Area of Refinery No.1

Ecolibrium. Law. and order Dramatically reimagining a heritage classic. AIRAH AWARDS ANNUAL DECEMBER 2018 VOLUME SPECIAL RRP $14.

STOURFLEX. Technically Advanced Flexible Solutions. A Guide to the Selection of STOURFLEX Pump Connectors

New ways of balancing two-pipe systems

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS

CALEFFI. dirt separator series 01137/16 NA. Replaces 01137/15 NA. Product range. Technical specifications

9. Cooling Water System

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

Thermostatic mixing valves with interchangeable cartridges

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions

Transcription:

CX Dirt and Air Separators

CX Product Overview Dutypoint CX The Dutypoint CX range of separators are designed to automatically remove dirt and air from heating, cooling and process systems, ensuring optimum performance of your equipment at all times. These should be installed in all new buildings and can be retro-fitted into existing systems to provide economic and environmental benefits. Separators should be installed in any sizeable open or closed loop system, including chilled water systems, condenser water systems, and process water systems. We offer six different standard configurations in a multitude of sizes to ensure we can provide the best solution for your application: CXC Dirt and Air Separator Combined units used in pipelines to efficiently remove air, micro bubbles and particles. See pages 3 and 4. CXC-RE Dirt and Air Separator with removable element As the CXC but with a removable flange to facilitate easy cleaning and maintenance. See pages 3 and 4. CXA Air Separator Used in pipelines to remove air and micro bubbles. See pages 7 and 8. CXP Dirt Separator Used in pipelines to remove impurities and particles. See pages 5 and 6. CXP-RE Dirt Separator with removable element As the CXP but with a removable flange to facilitate easy cleaning and maintenance. See pages 5 and 6. CXX Balancing Tank with Dirt and Air Separator A combination of the above units, plus facilitating proper mixing to keep the flow in the boiler and distribution circuits the same, providing optimum hydraulic balance. See pages 9 and 10. Separator Specification Body Carbon Steel - ST 37 Connections PN16 Max. Working Temperature 110 C Max. Working Pressure 10 Bar Internal Element AISI 304 Stainless Steel Air Vent Specification Body Brass Connections Screwed Max. Working Temperature 110 C Max. Working Pressure 10 Bar Float Polypropylene All units are designed and manufactured in accordance with Pressure Equipment Directive 97/23/EC, 1997. Larger units up to DN600 are available to order. 2

Product Overview CX Sizing Guide Dirt and air separators should be used in both heating and cooling systems. For optimum results, the flow velocity should be less than 1.5m/s. If the flow velocity is above 1.5m/s, efficiency will be reduced. Size (DN) 400 350 300 250 200 E 150 D 125 100 80 65 50 Figure 1: Sizing Graph C 7 8 9 10 15 20 30 40 50 60 70 80 100 150 200 300 500 700 A Flow (m3/h) 3 B Velocity V=1 m/s V = 1.5 m/s The following two installation examples may help in selecting the correct size unit (Figure 1): If the separator is installed in a low pressure, high temperature situation, the velocity should be 1.5m/s. On the Flow axis at point A (70m 3 /h), move vertically to point B on the 1.5m/s water velocity curve. Move left from point B to point D on the Dimensions axis. Choose the nearest dimension that is higher than point D. In this example you would select DN125. If the separator is installed in a high pressure, high temperature situation, the velocity should be 1m/s. On the Flow axis at point A (70m 3 /h), move vertically to point C on the 1m/s water velocity curve Move left from point C to point E on the Dimensions axis. Choose the nearest dimension that is higher than point E. In this example you would select DN150. Pressure Loss Use the chart below to determine the pressure loss across your chosen separator: Figure 2: Pressure Loss Graph 10 Separator Connection Size 50 65 80 100 125 150 200 250 Pressure Loss (kpa) C 1 B 0.1 1 10 Flow (m 3 /h) Pressure Loss Example: When the water flow is 70m 3 /h, the pressure loss for the DN150 dirt and air separator is 1kPa. 70 A 100 1000 On the Flow axis at point A (70m 3 /h), move vertically to point B on the DN150 line. Move left from point B to point C on the pressure loss axis. In this example the pressure loss would be 1 kpa. 3

CX Product Details CXC - Combined Dutypoint CXC combined dirt and air separators can be used instead of individual deaerators and dirt separators. These combined units are very efficient and extremely cost effective, becoming the preferred standard option throughout the industry. In heating systems, the units should be installed in the flow loop, situated immediately after the boiler and prior to the pump. In a chilled water system the unit must be located in the return loop close to the chiller. Standard Technical Features Efficient removal of air and micro bubbles in pipework Effective removal of impurities and particles Stainless steel element Designed and manufactured in accordance with the Options Removable element Larger units up to DN600 available on request Non-standard connections Note Pressure Equipment Directive 97/23/EC The static head must not exceed 15m for a heating system and 5m for a cooling system. CX-C HiVENT Max 15m The efficiency of the unit will be reduced if the system static head exceeds 15m of system flow velocity exceeds 3m/s Boiler PUMP Heating System HiVENT Visit dutypoint.com for full product listings, specifications and more CX-C Chiller Max 5m Cooling System 4

Drawing and Dimensions CX Dutypoint CXC Variants Model No. Flow Rate (m 3 /h) Volume (L) Weight (kg) Dimensions DN (mm) OD (mm) A (mm) B (mm) C H (mm) CXC Combined CX50C 8 7 17 50 60 265 350 1" 632 CX65C 15 7 18 65 76 265 350 1" 632 CX80C 20 25 38 80 88 345 470 1" 791 CX100C 30 25 40 100 114 345 475 1" 791 CX125C 50 75 62 125 139 480 635 1" 1064 CX150C 75 75 67 150 168 480 635 1" 1064 CX200C 125 150 150 200 219 615 775 1" 1307 CX250C 200 300 300 250 273 815 890 2" 1568 CX300C 275 500 545 300 323 970 1005 2" 1892 CXC-RE Combined with Removable Element CX50C-RE 8 7 37 50 60 265 350 1" 632 CX65C-RE 15 7 38 65 76 265 350 1" 632 CX80C-RE 20 25 61 80 88 345 470 1" 791 CX100C-RE 30 25 63 100 114 345 475 1" 791 CX125C-RE 50 75 102 125 139 480 635 1" 1064 CX150C-RE 75 75 107 150 168 480 635 1" 1064 CX200C-RE 125 150 207 200 219 615 775 1" 1307 CX250C-RE 200 300 373 250 273 815 890 2" 1568 CX300C-RE 275 500 624 300 323 970 1005 2" 1892 R 2½" B R ½" O.D. DN A H (PN16 FLANGED) C 5

CX Product Details CXP - Dirt Separators Dutypoint CXP Dirt Separators are designed to remove impurities and particles. These units should always be installed in systems before equipment that requires protection from dirt and sludge, such as boilers, chillers, control valves and pumps. In heating systems this should be in the return loop close to the boiler. In a chilled water system the unit should be located in the return loop close to the chiller. Periodic draining of the CXP will keep the system free of impurities, prolonging the life of other installed equipment. Standard Technical Features Efficient removal of air and micro bubbles in pipework Stainless steel element Designed and manufactured in accordance with the Pressure Equipment Directive 97/23/EC Options Removable element Larger units up to DN600 available on request Non-standard connections HiVENT CX-P Max 15m PUMP Boiler Heating System HiVENT CX-P Max 5m Chiller Cooling System 6

Drawing and Dimensions CX Dutypoint CXP Variants Model No. Flow Rate (m 3 /h) Volume (L) Weight (kg) Dimensions DN (mm) OD (mm) A (mm) B (mm) C H (mm) CXP Dirt/Particle Separators CX50P 8 5 15 50 60 267 350 1" 385 CX65P 15 5 16 65 76 265 350 1" 385 CX80P 20 17 28 80 88 390 470 1" 570 CX100P 30 17 30 100 114 353 475 1" 570 CX125P 50 50 62 125 139 454 635 1" 701 CX150P 75 50 65 150 168 454 635 1" 701 CX200P 125 100 120 200 219 623 775 1" 900 CX250P 200 200 230 250 273 840 890 2" 1130 CX300P 275 363 400 300 323 655 1005 2" 1150 CXP-RE Dirt/Particle Separators with Removable Element CX50P-RE 8 5 35 50 60 267 350 1" 385 CX65P-RE 15 5 36 65 76 265 350 1" 385 CX80P-RE 20 17 51 80 88 390 470 1" 570 CX100P-RE 30 17 53 100 114 353 475 1" 570 CX125P-RE 50 50 102 125 139 454 635 1" 701 CX150P-RE 75 50 105 150 168 454 635 1" 701 CX200P-RE 125 100 177 200 219 623 775 1" 900 CX250P-RE 200 200 303 250 273 840 890 2" 1130 CX300P-RE 275 363 479 300 323 655 1005 2" 1150 DN (PN16 FLANGED) A H O.D. B C 7

CX Product Details CXA - Air Separators Dutypoint CXA air separator units are installed to efficiently remove air and micro bubbles from the system. In heating systems, an air separator should be installed in the flow loop where the system experiences the highest temperature (next to the heat source) and lowest pressure. Air separators should ideally be installed immediately after the boiler and prior to the pump suction port as this is where the formation of micro bubbles is greatest. In a chilled water system the unit must be located in the return loop just prior to the chiller. Standard Technical Features Efficient removal of air and micro bubbles in pipework Stainless steel element Designed and manufactured in accordance with the Pressure Equipment Directive 97/23/EC Options Larger units up to DN600 available on request Non-standard connections HiVENT CX-A Max 15m PUMP Boiler Heating System HiVENT CX-A Max 5m Chiller Cooling System 8

Drawing and Dimensions CX Dutypoint CXA Variants Model No. Flow Rate (m 3 /h) Volume (L) Weight (kg) Dimensions DN (mm) OD (mm) A (mm) B (mm) C H (mm) CXA Air Separators CX50A 8 5 15 50 60 138 350 ½" 482 CX65A 15 5 16 65 76 138 350 ½" 482 CX80A 20 17 28 80 88 177 470 ½" 607 CX100A 30 17 30 100 114 177 475 ½" 607 CX125A 50 50 62 125 139 267 635 ½" 797 CX150A 75 50 65 150 168 267 635 ½" 797 CX200A 125 100 120 200 219 297 775 1" 996 CX250A 200 210 230 250 273 347 890 1" 1227 CX300A 275 360 400 300 323 385 1005 1" 1247 B R 2½" R ½" H O.D. DN A (PN16 FLANGED) C 9

CX Product Details CXX - Combined Dirt/Air Separator and Balancing Tank The Dutypoint CXX combines the benefits of a deaerator, a dirt separator and a hydraulic balancing tank in one unit. This can be used instead of an individual deaerator and dirt separator, with the added advantage of creating a perfect hydraulic balance between the primary and secondary circuits. The importance of having a well-balanced system cannot be overemphasised, as this greatly reduces energy consumption and increases boiler or chiller efficiency. It is vastly more cost effective to purchase this combined unit rather than individual items - saving both initial cost and installation time. Standard Technical Features Efficient removal of air and micro bubbles in pipework Effective removal of impurities and particles Stainless steel element Designed and manufactured in accordance with the Pressure Equipment Directive 97/23/EC Enables perfect hydraulic balance between primary and secondary circuits Options Non-standard connections Larger units up to DN600 available on request BOILERS HEATING ZONE DOMESTIC HOT WATER ZONE LOW TEMPERATURE HEATING ZONE CX-X Visit dutypoint.com for full product listings, specifications and more PRIMARY SECONDARY 10

Drawing and Dimensions CX Dutypoint CXX Variants Model No. Flow Rate (m 3 /h) Volume (L) Weight (kg) Dimensions DN (mm) OD (mm) A (mm) B (mm) C (mm) H (mm) CXX Combined Dirt/Air Separator and Balancing Tank CX50X 8 7 17 50 60 248 350 240 812 CX65X 15 7 18 65 76 273 350 305 927 CX80X 20 25 38 80 88 273 470 360 982 CX100X 30 25 40 100 114 348 475 462 1232 CX125X 50 75 62 125 139 448 635 560 1532 CX150X 75 75 67 150 168 543 635 670 1832 CX200X 125 150 150 200 219 695 775 870 2336 CX250X 200 300 300 250 273 850 890 1100 2876 CX300X 275 500 545 300 323 1010 1005 1295 3392 B DN (PN16 FLANGED) H O.D. 11

Shepherd Road, Gloucester, GL2 5EL T: +44 (0)1452 300592 F: +44 (0)1452 303691 E: sales@dutypoint.com www.dutypoint.com