VORTEX TUBE REFRIGERATION SYSTEM BASED ON COMPRESSED AIR

Similar documents
IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

COMPRESSOR LESS SOLAR REFRIGERATOR

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Enhancement of COP using Nanoadditives in Domestic Refrigerator

DESIGN AND FABRICATION OF A PORTABLE REFRIGERATOR BASED ON PELTIER EFFECT

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Performance investigation of Air-conditioning system using ejector as expansion device

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

Module 5: Combustion Technology. Lecture 38: Combustion Burners

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

Design & Fabrication of Hybrid Cooler

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

FABRICATION OF REFRIGERANT FLOW RATE WITH SPIRALLY COILED CAPILLARY TUBE

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering

CHAPTER 1 INTRODUCTION

PERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED

Fabrication and analysis of instantaneous water cooler by using isobutane as refrigerant

HEAT TRANSFER COEFFICIENT ENHANCEMENT IN NATURAL CONVECTION FROM HORIZONTAL RECTANGULAR FIN ARRAYS WITH PERFORATIONS

Design, Manufacturing of Chilled Water System for Process Cooling Application

HEAT TRANSFER ENHANCEMENT IN SHELL AND TUBE HEAT EXCHANGERS USING INSERTS

Modified Air Cooler with Split Cooling Unit

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

International Journal of Informative & Futuristic Research ISSN (Online):

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Keywords: Climate change; ozone depletion; Montreal protocol; eco-friendly refrigerant; hydrocarbon refrigerant; performance analysis.

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Design and Fabrication of Water Refrigeration System by Creating Vacuum

MODERN EVAPORATIVE COOLER

EXPERIMENTAL PERFORMANCE INVESTIGATION OF SWIRLING FLOW ENHANCEMENT ON FLUIDIZED BED DRYER

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Evaluation of COP in Refrigeration System by using Different Refrigerants

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

Reheating Refrigeration System

Enhancement of COP in Vapour Compression Refrigeration System

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance

PERFORMANCE OF A VERY LOW TEMPERATURE REFRIGERATION SYSTEM OPERATING WITH NATURAL FLUIDS

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Effect of Heat Exchanger Configuration on the Performance of Joule-Thomson Refrigerators

Study of Behavior of Refrigerant Mixtures in Domestic Refrigerator- Practical Research

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

EXPERIMENTAL INVESTIGATION ON SHELL AND TUBE HEAT EXCHANGER USING SEGMENTAL AND DISC-DOUGHNUT TYPE BAFFLES

Mallikarjun 1, Anandkumar S Malipatil 2

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

EFFECT OF INLET TEMPERATURE ON REYNOLDS NUMBER AND NUSSELT NUMBER WITH MIXED REFRIGERANTS FOR INDUSTRIAL APPLICATIONS

Improvement Of Energy Efficiency Ratio Of Refrigerant Compressor

International Journal of Advance Engineering and Research Development

Performance and Analytical Study of Cooler Cum Air Conditioner based on Vapour Compression Refrigeration System

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Performance Enhancement of Inclined Bubbling Fluidized Bed Paddy Dryer by Design Modification

Experimental performance evaluation of heat pump by using CO 2. as a refrigerant. IOP Conference Series: Materials Science and Engineering

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Performance Evaluation of VCRS with Nested Helical Shaped Condenser by Using R134a as Refrigerant

A Review of Different Types of Combine Cooling System

Performance of an Improved Household Refrigerator/Freezer

η second law = Second law efficiency

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

Using Evaporative Cooling Methods for Improving Performance of an Air-cooled Condenser

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

Available online Journal of Scientific and Engineering Research, 2018, 5(11): Research Article

Performance Analysis of Domestic Refrigeration System with Thermoelectric Module

International Journal of Research in Engineering and Innovation Vol-3, Issue-1 (2019), 1-5

TYPICAL INITIAL OUTPUT OF A CO 2 HEAT PUMP

Thermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

Performance Assessment of Water Cooled Condenser Refrigeration System

Design and Experimental Studies on Modified Solar Dryer

Oyelami S., Bolaji B. O.

Transcription:

International Journal of Mechanical Engineering and Technology (IJMET) Volume 6, Issue 7, July 2015, pp. 97-102, Article ID: 30120150607012 Available online at http://www.iaeme.com/currentissue.asp?jtype=ijmet&vtype=6&itype=7 ISSN Print: 0976 6340 and ISSN Online: 0976-6359 IAEME Publication VORTEX TUBE REFRIGERATION SYSTEM BASED ON COMPRESSED AIR Tejshree Bornare, Abhishek Badgujar and Prathamesh Natu Department of Mechanical Engineering, KGCE, Karjat, INDIA ABSTRACT Refrigeration plays an important role in developing countries, primarily for the preservation of food, medicine, and for air conditioning. Conventional refrigeration systems are using Freon as refrigerant. As they are the main cause for depletion of ozone layer, extensive research work is going on alternate refrigeration systems. Vortex tube is a non conventional cooling device, having no moving parts which will produce cold air and hot air from the source of compressed air without affecting the environment. When a high pressure air is tangentially injected into vortex chamber a strong vortex flow will be created which will be split into two air streams, one hot stream and the other is cold stream at its ends. An experimental investigation is to be performed in order to realize the behavior of a vortex tube system. In this work attention has to be focused on the classification of the parameters affecting vortex tube operation. The effective parameters are divided into two different types, namely geometrical and thermo-physical ones. A reliable test rig is to be designed and constructed to investigate the effect of geometrical parameters i.e. diameter and length of main tube, diameter of outlet orifice, shape of entrance nozzle.thermophysical parameters are inlet gas pressure, type of gas, cold gas mass ratio and moisture of inlet gas. Keywords: Refrigeration, Vortex tube, Cooling, Pressure, Gas, Test Cite this Article: Tejshree Bornare, Abhishek Badgujar and Prathamesh Natu, Vortex Tube Refrigeration System Based on Compressed Air. International Journal of Mechanical Engineering and Technology, 6(7), 2015, pp. 97-102. http://www.iaeme.com/currentissue.asp?jtype=ijmet&vtype=6&itype=7 http://www.iaeme.com/ijmet.asp 97 editor@iaeme.com

Tejshree Bornare, Abhishek Badgujar and Prathamesh Natu 1. INTRODUCTION Refrigeration and Air-Conditioning play an important role in modern Human Life. They not only offer comfortable and healthy living environments but also become a necessity of life to survive for server weather. The accelerated technical development and economic growth of most counties during the last century has produced sever environmental problems. Approximately 66 million new refrigerator and freezers units are manufactured worldwide each year and hundreds of millions are currently in use. It is anticipated that the production of refrigerator and freezer and the inventory will substantially increase in the near future due to an increased demand is especially in developing countries. In order to protect the environment it is important that the non-cfc refrigeration system designs are to be incorporated as early as possible and retrofits are to be developed for existing refrigerators and freezers using suitable substitute refrigerants. Probably the most widely used current application of refrigeration are for air conditioning of private homes and public buildings, and refrigerating foodstuffs in homes, restaurants and large storage warehouses. The use of refrigerators in kitchen for storing fruits and vegetables has allowed adding fresh salads to the modern diet year round, and storing fish and meats safely for long periods. By using vortex tube refrigeration system both hot and cold cooling effect can be produced without any harm to the environment. This is the main advantage of Vortex tube refrigeration system based on Compressed air. 2. LITERATURE REVIEW The Vortex Tube, is a mechanical device that separates a compressed gas into hot cold streams. It does not have any moving parts. Pressurized gas is injected tangentially into a swirl chamber and accelerates to a high rate of rotation. Due to the conical nozzle at the end of the tube, only the outer shell of the compressed air is allowed to escape at the end. The remainder of the air is forced to return in an inner vortex of reduced diameter within the outer vortex. When used to refrigerate, heat-sinking the whole vortex tube is helpful. Vortex tubes can also be cascaded. The cold (or hot) output of one can be used to pre-cool (or pre-heat) the air supply to another vortex tube. Vortex Refrigeration is a highly sophisticated system that contains a Vortex Tube which due to centrifugal force expels the internal energy of the air while the air at the center core is made cooler. In this type of system the effectiveness is too low but considering its small size this can t be ruled off. This is used as personal cooling system in suits that are designed to withstand heat. 3. WORKING Compressed air at high pressure enters the vortex tube through tangential nozzle where the flow gets accelerated. Due to tangential entry, the air has high velocity and rotates at very high speed. Thus the air has whirling or vortex motion by using six slot brass spinner in vortex chamber. The end of the cold pipe, which built up with the vortex chamber, is fitted with a washer that has the half the diameter of the pipe. Washers with different diameter are also used to adjust the system. Thus cold air is produced at right end and hot air is produced at the left end of the vortex tube. http://www.iaeme.com/ijmet.asp 98 editor@iaeme.com

Vortex Tube Refrigeration System Based on Compressed Air Figure 1 Actual picture of the Vortex Tube Figure 2 Actual diagram of 6 slot Spinner Figure 3 Actual diagram of Restrictor http://www.iaeme.com/ijmet.asp 99 editor@iaeme.com

Tejshree Bornare, Abhishek Badgujar and Prathamesh Natu 4. EXPERIMENTATION The experimental setup consists of compressor, vortex tube and temperature indicator. A stop valve at the compressor reservoir exit controls the inlet air to the vortex chamber. The inlet pressure is measured using pressure gauge. The temperatures of the air at inlet, at cold end, at hot end and ambient air are measured using thermocouple. 5. FIGURES AND TABLES: 5.1Calculations 1. Pressure Range = (9-8 bar) 2. = 23 3. Area = (/4)*D^2 4. T(atm) = T(inlet) = 30 5. Velocity = 15.6 m/s 6. Discharge (q) = 4.41*10-4 m 3 /s 7. Mass Flow Rate (m) = 5.403*10-4 kg/s 8. Cooling Effect (q) = 11.94*10-3 m 3 /s 9. Heating Effect (Q) = 3.79*10-3 m 3 /s Table No 5.1 Difference And Velocity: Sr. No. Pressure Range (bar) Inlet ( ) Hot End ( ) Cold End ( ) Difference Velocity (m/s) 1. 9-8 30 37 14 23 15.6 2. 8-7 30 36 15 21 15.1 3. 7-6 30 34 16 18 14.6 4. 6-5 30 34 16 18 14.0 5. 5-4 30 33 17 17 13.8 Table No 5.2 Cooling Effect: Sr. No. Pressure Range (bar) CoolingEffect Q=m*Cp* T 1. 9-8 23 7 11.94 2. 8-7 21 6 10.51 3. 7-6 18 4 9.14 4. 6-5 18 4 8.28 5. 5-4 17 3 7.20 http://www.iaeme.com/ijmet.asp 100 editor@iaeme.com

Vortex Tube Refrigeration System Based on Compressed Air Table No 5.3 Heating Effect: Sr. No. Pressure Range (bar) HeatingEffect Q=m*Cp* 1. 9-8 23 7 3.79 2. 8-7 21 6 3.15 3. 7-6 18 4 2.03 4. 6-5 18 4 1.95 5. 5-4 17 3 1.44 6. CONCLUSION A simple model of the Vortex Tube is described that captures the physics related to one possible operating mechanism. The model is shown to faithfully reproduce a limited set of data if two empirical parameters are adjusted. The semi-empirical model is subsequently used to evaluate the potential performance benefit associated with replacing the throttling valve in a refrigeration system with an approximately optimized Vortex Tube. An experimental study on the temperature separation in the Vortex Tube has been carried out and this research finding can be summarized as follows 1. difference increases with increase in Inlet Pressure. 2. Availability destruction decreases with increase in tube length due to the increase in temperature difference. 3. Efficient working point of the existing design is at a cold mass fraction 0.84 for an inlet pressure of 5bar. 4. Availability destruction is less in the case of Vortex Tube operation with two nozzles than with one nozzle due to the increase in temperature difference. 5. The increase of the number of inlet nozzles led to higher temperature separation in the Vortex Tube. 6. Using the tube with insulation to reduce energy loss to surroundings gave a higher temperature separation in the tube than that without insulation around 2-3 for the cold tube and 2-5 for the hot Tube. 7. A small cold orifice (d/d=0.4) yielded higher backpressure with a large cold orifice (d/d=0.7, 0.8, and 0.9) allowed higher tangential velocities into the cold tube, resulting in lower thermal energy separation in the tube. 8. The performance of a conventional vapor compression refrigeration cycle cannot be augmented through the application of a Vortex Tube because no temperature separation can occur beneath the vapor dome. 9. The performance of a vapor compression cycle operating in the near supercritical region, such as carbon dioxide refrigeration cycle, is negligibly increased by the application of a Vortex Tube. http://www.iaeme.com/ijmet.asp 101 editor@iaeme.com

Tejshree Bornare, Abhishek Badgujar and Prathamesh Natu 7. REFERENCES [1] PRABAKARAN.J, Effect of Diameter of Orifice and Nozzle on the performance of Counter flow Vortex tube, IJEST. [2] S.C Arora and S. Domkundwar, A course in refrigeration and air conditioning, Dhanapat Rai & Sons Publications, 3rd Edition, 2009, Delhi 229. [3] R.S.Khurmi and J.K.Gupta Refrigeration and Air Conditioning, S.Chand publication, 4th Edition, 2008, Delhi pp. 310-325. [4] Volkan Kirmaci, Energy analysis and performance of a counter flow Ranque Hilsch vortex tube having various nozzle numbers at different inlet pressures of oxygen and air, Elsevier journal, May 2009. [5] Soni and Thomson, Optimal design of RanqueHilsch vortex tube. ASME J. Heat transfer. 94(2), 1975, pp.316-317. [6] Alka Bani Agrawal and Vipin Shrivastava, Retrofitting of vapour compression refrigeration trainer by an eco-friendly refrigerant. Indian J. Sci. Technol. 3(4). 2010 This issue. Domain: http://www.indjst.org. [7] J. Prabakaran., S. Vaidyanatha., Effect of Orifice and Pressure of Counter Flow Vortex Tube, IJST, 3(4), 2010, 374-376 [8] R. Shamsoddini, A. H. Nezhad, Numerical analysis of the effects of nozzles number on the flow and power of cooling of a vortex tube, International Journal of Refrigeration, 33 (4), 2010, 774 782 [9] Peethambaran K M, Asok Kumar N and John T D, Adsorption Refrigeration System for Automobiles an Experimental Approach International Journal of Mechanical Engineering & Technology, Vol 3 (2), 2012, pp. 633-642. [10] S. Nimbalkar and M. R Muller., An experimental investigation of the optimum geometry for the cold end orifice of a vortex tube, Applied Thermal Engineering, 29(2-3), 2009, pp.509 514. http://www.iaeme.com/ijmet.asp 102 editor@iaeme.com