Water Cooled Condenser Using Nano Fluids

Similar documents
Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Enhancement of COP in Vapour Compression Refrigeration System

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Performance Optimization of the Evaporative Condenser Design

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Design, Manufacturing of Chilled Water System for Process Cooling Application

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Modified Air Cooler with Split Cooling Unit

Design and Development of Water Cooled Condenser for Domestic Refrigerator

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

II. OBJECTIVE OF RESEARCH

Performance Assessment of Water Cooled Condenser Refrigeration System

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

In the name of God. Jami Institute of Jami - Mehdi Rasti

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

Experimentation of Heat Pipe Used In Nano-Fluids

TITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System


Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

ENHANCEMENT OF HEAT TRANSFER USING NANO-REFRIGERANT. * Corresponding author s

Mechanical Engineering Department Sheet (1)

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

ENHANCEMENT OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING NANOFLUIDS

Investigation and Optimization of Air Cooled Condenser of Chillers by Replacing Cu to Al Tubes

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

EFFECT OF INLET TEMPERATURE ON REYNOLDS NUMBER AND NUSSELT NUMBER WITH MIXED REFRIGERANTS FOR INDUSTRIAL APPLICATIONS

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Performance of an Improved Household Refrigerator/Freezer

Reheating Refrigeration System

[Mali*, 4.(12): December, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Design of solar powered vapour absorption refrigeration system

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

Experimental analysis of condensation heat transfer enhancement of steam at low pressures using modified twisted tape insert

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

REVIEW OF DESIGN OF SINGLE EFFECT SOLAR POWERED VAPOUR ABSORPTION AIR CONDITIONING SYSTEM

HVAC Fundamentals & Refrigeration Cycle

VCR SYSTEM USING R-600a/ POE OIL/MINERAL OIL/NANO-SiO 2 AS WORKING FLUID: AN EXPERIMENTAL INVESTIGATION

Pressure Enthalpy Charts

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

Performance Enhancement of Mini Refrigerator with Phase Change Materials

THE GATE COACH All Rights Reserved 28, Jia Sarai N.Delhi-16, ,-9998

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis

Performance Analysis of VCRS with Nano-Refrigerant

COMPARATIVE ANALYSIS OF SINGLE AND DOUBLE EFFECT LiBr-WATER ABSORPTION SYSTEM

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

2. HEAT EXCHANGERS MESA

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Design & Fabrication of Hybrid Cooler

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Effect of Inclination Angle in Heat Pipe Performance Using Copper Nanofluid

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

Global Journal of Engineering Science and Research Management

Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Yogesh B Desale, J. H. Bhangale. Abstract

A performance study of Vapour compression refrigeration system using ZrO2 Nano particle with R134a and R152a

STUDY, ANALYSIS AND DESIGN OF AUTOMOBILE RADIATOR (HEAT EXCHANGER) PROPOSED WITH CAD DRAWINGS AND GEOMETRICAL MODEL OF THE FAN

Figure 1: Overview of CO 2 evaporator types

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

EXPERIMENTAL INVESTIGATION OF HYBRID NANOFLUID ON THERMOSYPHON TYPE WICKLESS HEAT PIPE HEAT EXCHANGER THERMAL PERFORMANCE

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Compendium DES July 2016, CARN

WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

(Refer Slide Time: 00:00:40 min)

ISSN Vol.08,Issue.21, November-2016, Pages:

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Transcription:

Water Cooled Condenser Using Nano Fluids Vishal Vilas Khade Research Scholar, Department of Mechanical Engineering, Ashokrao Mane Group of Institutions, Vathar tarf Vadgaon, Kolhapur, India. Rahul A. Patil Assistant Professor, Department of Mechanical Engineering, Ashokrao Mane Group of Institutions, Vathar tarf Vadgaon, Kolhapur, India. Abstract Water cooler is one of the familiar appliances utilizing vapour compression cycle in its process. Performance of the system becomes main issue and many researches are still on going to evaluate and improve efficiency of the system. The main objective is to improve performance of the refrigeration system in term of Compressor work and Coefficient of performance (COP) by determining three important parameters during in operating mode which are temperature, pressure and refrigerant flow rate. We are going to introduce the water cooled condenser along with CuO Nano particles in a model of domestic water cooler for cooling the refrigerant and the effect of condenser temperature on COP and refrigerating effect is in investigated. The energy consumption of the water cooler during experiment with refrigerant R134a will be measured. Nano fluid is an advanced kind of fluid, which contains nanometer, sized solid particles that are known as nanoparticles. Nanoparticles enhance the property of normal fluid.in the conventional water cooler, condenser heat loss via conduction-radiation (copper tube-atmosphere). In our research work, we are trying to increase heat loss in condenser with some additional device attachment (copper tube flow with Nano fluid).with the help of our arrangement heat loss increases via conduction-convection-radiation. So our arrangement increasing heat loss and our goal is achieve. With this setup we are increasing COP of water cooler using water cooed condenser along with Nano particles. Key words:water Cooled Condenser, Tube in tube type condenser, Refrigerant R134-A, Coefficient of performance, Nano fluid- CuO Introduction Energy is an important entity for the economic development of any country. The rapid industrial and economic growths in India and China where one third population of the world live, have increased the need of energy rapidly in the recent years. Considering the environmental protection and also in the context of great uncertainty over future energy supplies, attention is concentrated on the utilization of sustainable sources and the energy conservation methodologies. Today world s 15% of total electrical energy is used for refrigerating and air conditioning applications (As per US Department of energy). In refrigeration and air conditioning systems, the compressor is the largest consumer of electricity, in most of the cases consuming about 70% of total electricity. Refrigeration and air conditioning systems tend to underperform in extremely hot climatic conditions as prevailed in South-East-Asian nations. Generally an air cooled condenser is employed to reject heat from conditioned space to outdoors. The reason being to make the system as simple as possible without any need to the water connection line and other equipment s. This idea seems quite reasonable as far as the air temperature in summer is moderate and not too high, say about 35-37 ºC. However, summer temperature in South- East-Asian often exceeds this range. Temperature of air-cooled condenser directly depends on the ambient air temperature. Therefore, in area with very hot weather temperature in summer; the condenser temperature and pressure are increased considerably which consequently increases the power consumption of the refrigeration system due to increase in the pressure ratio. Increasing condenser temperature also decreases cooling capacity of the cycle due to the reduction of liquid content in the evaporator. This two effect decrease performance of the system considerably in the area with very hot weather temperatures prevailing summer. Thus, water cooler turns out to be the major contributors to the summer peak electrical demands in most of the nations. Therefore, it is important to have a refrigeration system which can decrease the energy demands and also improve the C.O.P. Compressor Power As mentioned above compressor is the main consumer of electricity in refrigeration and air conditioning systems. Hence to have an energy efficient system we need to reduce compressor power. One of the factor on which compressor power depends is the temperature of heat reduction at the condenser. If the temperature of heat rejection at condenser is high, correspondingly compressor consumes relatively more power in order to bring refrigerant temperature higher than that of cooling medium temperature. It is always beneficial in terms of energy conservation to reduce temperature of heat reduction by employing proper method of heat rejection at condenser side. 771

A lot depends on condenser design or its operating temperature and pressure. Either the condenser needs to be redesigned, altering its length and/or diameter or by adopting techniques like internal grooving, optimizing external fins, fin length, fin spacing etc. or the other option is to reduce the operating temperature and pressure of existing condenser design by some means. The p-h chart as seen in fig. shows that, if the condenser temperature and pressure is reduced, the compressor work is reduced whereas the refrigeration effect is increased. This indicates that by improving the condenser cooling to reduce it temperature and pressure, the system performance can be enhanced. Fig. 1Chart showing effects of condenser temperature and pressure Methodology In hot climatic countries especially in South-East- Asian countries, due to hot climatic conditions throughout the year, need of cold water for drinking always prevails. This increases use of the water cooler. Conventional water cooler operates on vapor compression system where air is used as cooling medium at the condenser. Air is available at an atmospheric temperature and hence compressor has to compress the refrigerant to temperature higher than atmospheric temperature. Consequently there is increase in the ambient temperature and performance of the water cooler reduces due to under-cooling of the condenser. The one way to reduce the compressor work is to decrease the condenser pressure which needs to decrease the condenser heat rejection temperature. To reduce heat rejection temperature at the condenser, an alternate cooling medium instead of air can be used, and water along with Nano fluid could be an alternate cooling medium which is available at lower. Further, availability of water is also easy for cooler as it has already sustained water connection and always near water source. Water Cooled Condenser Water is another cooling medium which is easily available and is at much lower temperature than atmospheric air. Water is more preferable as cooling medium rather than the air because of following reasons: It is available at temperature lower than that of air. Its temperature approaches to the wet bulb temperature of the surrounding air. The specific heat of water is about four times that of air. Hence for the same heat rejection and same mass flow, the temperature rise of water is one-fourth that of air and correspondingly temperature of heat rejection is lower. Water has higher heat transfer coefficient than the air mainly because of its high thermal conductivity. Thus for the same heat rejection and same area of heat exchanger, the temperature difference required across the heat exchanger is less which also results in lower value of temperature of heat rejection. Hence the use of water as cooling medium results in lower heat rejection temperature at condenser, which will decrease the compressor power and hence COP will also improve. All this will result into energy efficient system. Using water as cooling medium there will be more compact and smaller condenser even with the smaller value of mean temperature difference. Therefore to decrease the energy consumption and to have a better performance of the water cooler use to water as cooling medium at the condenser side can be good option. Water cooled condenser system can be of two types viz. open cooling water cooled condenser and another is closed cooling water cooled condenser. In the open cooling water cooled condenser system the water is directly sprinkled or made to flow over the condenser tube. This cooling system is similar to the cooling tower. This cooling system requires pumping system to sprinkle water over condenser tube and the collecting system to collect the water sprinkled over condenser tubes. In this closed cooling water cooled condenser system generally we use the heat exchanger to exchange the heat between the cooling water and the condenser. Internal water cooling system is more preferred over external due to following advantages, It improves flexibility in site location problems. Generally external cooling water cooled condenser systems must be installed above the heat source and the internal cooling system can be placed anywhere. Generally we can maintain the high pressure of the cooling medium in the internal cooling water cooled condenser system, which leads to better cooling in short period of time. External cooling water cooled condenser system requires more space compared to the internal cooling water cooled condenser system. Internal cooling water system is more compact than the open cooling water cooled condenser system. Hence external cooling water cooled condenser system is a better option Nano Fluid A Nanofluid is a mixture of water and suspended metallic nanoparticles. Since the thermal conductivity of metallic solids are typically orders of magnitude higher than that of fluids it is expected that a solid/fluid mixture will have higher effective thermal conductivity compared to the base fluid. Thus, the presence of the nanoparticles changes the transport properties of the base fluid thereby increasing the 772

effective thermal conductivity and heat capacity, which ultimately enhance the heat transfer rate of Nano fluids. Because of the small size of the nanoparticles (10-9 m), Nano fluids incur little or no penalty in pressure drop and other flow characteristics when used in low concentrations. Nano fluids are extremely stable and exhibit no significant settling under static conditions, even after weeks or months. In their work (Lee & Choi) on the application of Nano fluids reported significant cooling enhancement without clogging the microchannels. Fig. 2 Copper Oxide Nanoparticles are very small nanometre sized particles with dimensions 0.1-1000 nm (nanometres) in size. Some of the common oxide nanoparticles being used in heat transfer research are: Zinc Oxide (ZnO), Zirconia (ZrO2), Copper Oxide (CuO), Aluminium Oxide (Al2O3), and Titanium Oxide (TiO2) while some of the metal nanoparticles are Gold (Au), Silver (Ag), and Copper (Cu). Conventional fluids being mixed with nanoparticles are: water, ethylene glycol, and oil. Water is a convenient and safe medium; however, it has poor heat transfer characteristics which are a major disadvantage. For example, water is roughly three orders of magnitude poorer in heat conduction than copper; as is the case with coolants such as engine coolants, lubricants, and organic coolants. The use of Nano fluids (nanoparticles + conventional fluids), like water, may possess the ability to increase the convection heat transfer characteristics of that particular fluid. Refrigerant The suitability of refrigerant for a certain application is determined by its physical, thermodynamic, chemical properties and by various practical factors. There is no one refrigerant which can be used for all types of applications i.e. there is no ideal refrigerant. If one refrigerant is chosen which has greater advantages and less disadvantages. So, we have used refrigerant R-134a. Design of Water Cooled Condenser Many commercial design and types of heat exchangers are available in market. Selection of the type of heat exchanger for the given application is based on following considerations/constrains: Compactness of the heat exchanger Minimum cost Minimum disturbance to the existing process line due to this new installation Applications Space requirement Depending on the temperature of the heat rejection at condenser, a suitable heat exchanger is to be selected that facilitates heat exchanger. Heat exchangers such as shell and tube, plate and fin type, double pipe, etc. are available. It is desirable to have compact, cost effective and better performance heat exchanger. Shell and tube heat exchanger being neither compact nor cost effective, was not considered. Further, plate fin type heat exchanger is best both performance wise and compactness wise, but high cost of it does not make it suitable for our application. Double pipe heat exchanger is compact one and cost effective, therefore it can be better option for our application. Hence it is decided to replace existing air cooled condenser by double pipe water cooled condenser with the arrangement to use the waste water of cooler. Thermal design of the heat exchanger is carried out on the following considerations: Flow rates of both fluids; inlet temperature of cooling water, power consumed by compressor, cooling capacity, mass of water to be cooled, velocity of cooling water are required. Fouling resistance for both streams are to be furnished, the designer should adopt values specified in the standards or based on past experience. Physical and thermal properties of both streams include velocity, thermal conductivity, density, specific heat and Prandtl number, preferably at both inlet and outlet temperatures. Velocity data must be supplied at inlet and outlet temperatures, especially for liquids, since the variation with temperature may be considerable and is irregular. Condenser line sizes are desirable to much nozzle sizes with existing line sizes to avoid expanders or reducers. Preferred tube sizes are designated as I.D., O.D., thickness and length. Some plant owners have proffered I.D., O.D., thickness and the available plot area will determine the maximum tube length.many plant owners prefer to standardize all four dimensions, again based upon inventory considerations. Materials of construction, for maximum heat transfer on refrigerant side copper issued and for outer side cast steel is used. Design Methodology Heat exchanger is designed for water cooler having following specifications: Made ST 4-80 Power consumption 575 Refrigerant R-134a, 375gm Storage tank 80 liters Cooling capacity 40 liters/hour 773

Compressor KCE 443 HAE Cooling water at temperature tcw1 enters outer pipe of double pipe condenser and leaves the condenser at temperature tcw2 as shown in Fig. 3. At the same time refrigerant enters the inner tube of double pipe condenser in at temperature t sup 1 and leaves the condenser at temperature t4. global heat transfer coefficient is calculated or identified as we have done above in our designing. But we have to consider a more detailed model which distinguish between the different zones and identifies a specific heat transfer coefficient for each zone. This approach allows us to verify the separate influences of gaseous, two-phase and liquid zones on the heat exchanger performance. Set up Diagram Fig. 3.Double pipe heat exchanger Fig.4.Refrigeration cycle on T-S diagram Fig. 4 shows refrigeration cycle on T-S diagram. The refrigerant enters the condenser in a superheated state. It is first de-superheated and then condensed by rejecting heat to an external medium. Here, it is assumed that refrigerant leaves the condenser as a sub cooled liquid. The heat rejection process is represented by 2-3 -3-4. The temperature profile of the water, which is assumed to undergo only sensible heat transfer, is shown by dashed line. It can be seen that process 2-3 is a de-superheating process, during which the refrigerant is cooled sensibly from a temperature T2 to the saturation temperature corresponding condensing pressure, T3. Process 3-3 is the condensation process, during which the temperature of the refrigerant remains constant as it undergoes a phase change process. Process 3-4 is a sensible, sub cooling process, during which the refrigerant temperature drops from T3 to T4. It is also assumed that during evaporation process refrigerant gets superheated and enters the compressor in the superheated state. During its path through condenser, the refrigerant coexists in three phases. Refrigerant enters a gaseous state, goes through a two-phase state and finally leaves the condenser in a liquid state as shown in fig 4.3. Generally during designing of condenser or modeling, three zones are considered as one lumped two-phase zone, where only one Fig.5. Schematic diagram of modified water cooler with water cooled condenser Calculations Cooling capacity of system in KW is given by, Q coolingcapacity = mw. C p w.δt = 40 * 4.186 * ( 28 16 ) 3600 = 0.5581 kw By using cooling capacity and the power consumed calculate the total amount of heat rejected by using First law of Thermodynamics as, Q rej = Q cooling capacity + { Input Power} = 0.5581 + {0.45} = 1.0081 kw Assuming temperature of heat rejection at condenser, temperature at evaporator and the temperature of sub-cooling; calculated the temperatures at entry and exit of the compressor and from that calculate enthalpies at entries and exists of compressor, condenser and evaporator. Assumed temperature:- T1 = 10.8 C T2 = 24.5 C T3 = 80.4 C T4 = 41.8 C T5 = 16 C h1 =424 kj/kg P1 = 2.41 bar h2 = 468 kj/kg P2 = 10.81 bar h3 = 260 kj/kg h4 = 260 kj/kg 774

NOTE Enthalpy values are taken from p-h chart of R- 134a at desired pressure. Calculating refrigerating effect Re = h1 h4 = (424-260) Re = 164 KJ/Kg Calculate mass flow of refrigerant Mr = Q cooling capacity /RE = 0.5581 / 164 = 0.0033 Kg/s By using heat balance equation at condenser side we will calculate exit temperature of the cooling water as, Assume Tcw2 = 26 C M cw.cp.cw (t cw2 - t cw1 ) = Mr (h2 - h4) M cw. 4.186*(30-26) = 0.0033(468-260) M cw = 0.0409 Kg/s Volume flow rate of cooling water M cw = (ρ cw )*(Vol cw ) 0.0409 = (1000)*( Volcw) VOL CW = 4.09*10-5 m 3 /sec Calculate the Velocity of cooling water VOL CW = ( 3.14 Di 2 do 2 Vcw ) 4 4.09*10-5 = ( 3.14 0.025 2 0.006 2 Vcw ) 4 V cw = 0.08845 m/s Assume, Temperature of cooling water inlet to condenser = 26 c Temperature of cooling water exit to condenser = 30 c Mean value = 26+30 2 = 28 C Values for temperature 28 C (for cooling water) Viscosity (µ) = 0.83x10-3 Kg/m-s Density (ρr) = 99.4 Kg/m 3 Thermal conductivity (Kr) = 0.611w/m-k Specific heat (Cp) = 4178.8 J/Kg-K Prandlt no. (Pr) = 5.708 For liquid phase (for refrigerant R-134a) at temp. = 81.4+41 = 2 61.2 C Viscosity (µ) = 1.239x10-4 Kg/m-s Density (ρr) = 1220 Kg/m 3 Thermal conductivity (Kr) = 0.0640w/m-k Specific heat (Cp) = 1672.86 J/Kg-K Prandlt no. (Pr) = 3.234 Liquid Reynold s no. Re L = ρvd µ = 99.4 0.088 0.025 0.83x10 3 Re L = 2650.60 Nussle no. Nu = 0.023* Re 0.2 * Pr 0.3 = 0.023* (2650.6) 0.2 * (5.708) 0.3 = 1.946 Nu Kr ho = Lc = 1.946 0.611 0.00624 = 190.54 W/m 2 C Vapor Reynold s no. R ev = ρvd = µ 1220 0.04 0.006 1.239x10 4 Re L = 2363.19 Nussle no. Nu = 0.023* Re 0.2 * Pr 0.3 = 0.023* (2363.19) 0.2 * (3.234) 0.3 = 2.72 Nu Kr hi = Lc = 2.72 0.0640 0.00149 = 117.02 W/m 2 C Calculate the log mean temperature difference (LMTD) LMTD = (ΔT1 ΔT2) ln (ΔT1/ΔT2) For parallel flow ΔT1 = Th1 Tc1 = 81.4 26 = 55.4 C ΔT2 = Th2 Tc2 = 41 30 = 11 C By LMTD --- LMTD = (55.4 11) ln (55.4/11) = 27.46 Overall heat transfer coefficient (Uo) 1 Uo = 1 hi + 1 ho 1 = 1 117.02 + 1 190.54 = 72.50 W/mK Uo= 72.50x10-3 kw/mk LENGTH OF CONDENSER (L) = Q = Uo.A.Өm Q = Uo(3.14*D*L)*(ΔT1-ΔT2) 1.0081 = 72.50*10-3 *3.14*0.025*L*27.46 L = 6.45m Observations for water cooler with Nano fluid (CuO + water) cooled condenser 775

Calculations for 16 0 C temperature of drinking water 1. Theoretical C.O.P. = h1 h4 h2 h1 From P-h chart h1 = 408 KJ/Kg h2 = 435 KJ/Kg 2. Actual C.O.P. = = = 408 240 435 408 = 6.22 mr (h1 h4) Nc 3600 Tc 3200 0.0033 (408 240) 10 3600 24.9 3200 = 1.23 3. Plant capacity = mr*(h1-h4) = 0.0033*(408-240) = 0.5544 KJ/sec h4 = 240 KJ/Kg Plant capacity 4. Power required to drive compressor = Actual COP Result table = 0.5544 1.23 = 0.4507 kw revolution of energy meter is more as compared to air cooled system. 4. Used system is closed type so quantity of water required for cooling purpose in condenser is less compared with open type system. 5. Addition of nanoparticles in water enhance the heat transfer rate of water. The COP of system is increased upto 17.14% due to reduction in power consumed by compressor. References [1] J Anandkumar, To conduct the performance test chiller unit by using Nano fluid cooled condenser. International Journal of Mechanical Engineering and Robotic Research, Vol.4, January 2015. [2] Satnam Singh, Kapil Sharma, KundanLal, Naveen Mani Tripathi, To study the behavior of nanorefrigerant in vapor compression cycle A review, International Journal of Research in Engineering and Technology, Vol.4, Issue: 04 April 2015. [3] Parvindersingh, To study application of Nano refrigerant in refrigeration system : A review International Journal of Research in Engineering and Technology, Vol.4, Issue: 06 June 2015. [4] Rahul A Bhogare, B. S. Kothwale, A review on application and challenges of Nano fluids as a coolant in automobile radiator International Journal of Scientific Research Publication, Vol.3, Issue: 08 August 2013. [5] Fundamental of Heat and Mass Transfer, R. C. Sachdev, Willey Eastern Ltd. [6] Heat transfer A practical approach Yunus A. Cengel (Tata McGraw Hill). [7] A Textbook of Refrigeration and Air conditioning, Khurmi, Gupta, S. Chand Group. Conclusion 1. Water cooled condenser system enhances COP and reduces energy consumption. 2. Increasing performance of water cooler, but Nano fluid (CuO + water) cooled condenser system gives more COP than that of air cooled & water cooled condenser system. 3. Reduction in power required to drive compressor upto 11.83%, because time required for 10 776