A COST EFFECTIVE APPROACH TO IMPLEMENTING CHANGE OVER SYSTEM

Similar documents
The Design of Temperature Control System for Vegetable Greenhouse

AUTOMATIC STREET LIGHT CONTROL SYSTEM USING MICROCONTROLLER

A Cost Effective Embedded Design for Security and Automation in Industries

Design & Control of an Elevator Control System using PLC

XBee Based Industrial And Home Security System

Break-in Detection and Alarm System

BOILED WATER TEMPERATURE MEASUREMENT SYSTEM USING PIC MICROCONTROLLER

AUTOMATIC ROOM LIGHT AND FAN CONTROLLER WITH BI- DIRECTIONAL VISITOR COUNTER

Implementation of Auto Car Washing System Using Two Robotic Arms

Design of Multi-Functional Alcohol Concentration Detecting System Zhang Chong, Zhang Yue

Sensor Technology. Summer School: Advanced Microsystems Technologies for Sensor Applications

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Remote Environment Monitoring & Detection Tribot

Fin-Fan Control System

Design of Microwave Anti-theft Alarm Based on Microcontroller

International Journal of Engineering Research & Management Technology

Android Controlled Fire Fighting Robot

Using Motion Sensor for Auto Controlling Air Conditioner s Temperature

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Industrial and home safety Management using GSM

ANTI SLEEP ALARM INTRODUCTION

Microcontroller based design for Tele-sensing and extinguishing fire

(12) United States Patent (10) Patent No.: US 7,190,120 B1

Application, Installation, Operation & Maintenance Manual

AC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL

Railway Fault Detection System using Mobile Communication and Sensor Technology

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

CIRCUIT BREAKER FAIL PROTECTION

GORAKSHAK : AN AUTOMATED FARM VIA IOT

Automatic Temperature Control Using PIC Microcontroller Aditya Srivastava; Anuj Upadhyay; Tanya Sharma & Vishal Srivastava

Design and Development of General Purpose Alarm Generator for Automated System

International Journal Of Advanced Research In Engineering Technology & Sciences

Design and Implementation of a Temperature and Humidity Control System for a Poultry House Prototype

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

6367(Print), ISSN (Online) Volume (IJCET) 3, Issue 2, July- September (2012), IAEME

Fire Control Panel FS4000

Design of Cold Light Source System for Medical LED Endoscope

Vocia VACIE. Reference Guide

M2500 Engine Controller Installation Manual

The design of the human body infrared thermometer

April 27, 2016 ECE ECE Design

VACIE REFERENCE GUIDE REVISION 1.2.6

Digital Electronic Thermostat With RF

Innovative EEE mini-projects list

POWER PLANT MONITORING AND CONTROL USING GSM MODEM Syed Zeeshan Ali* 1, Abhijeet Bajpayee 2

Wireless Sensor Network Based Bank Monitoring System Using LabVIEW

JOURNAL OF ADVANCEMENT IN ENGINEERING AND TECHNOLOGY

Design of Intelligent Humidity Sensing Watering System Based on MCU

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

Web Site: Forums: forums.parallax.com Sales: Technical:

FlameGard 5 UV/IR HART

Installation, Operating and Maintenance Manual

Self-learning Room Temperature Controller

Public Safety DAS Annunciator Panel

Liquid Helium Level Instruments

System-CoolAC. Bharatividyapeeth College of Engineering, Deekshant Bharti Scholar, New Delhi, India

Implementation of an Embedded Microcontroller-Based Intrusion Detection System

Digital Electronic Thermostat With RF

Construction of An Automatic Power Switch using Infrared Motion Sensor

International Journal of Scientific Research and Reviews

Web Site: Forums: forums.parallax.com Sales: Technical:

D A R A - 4. Data Aire Relay Auto-Changeover

ACCURATE ELECTRONICS INC

Research on the Monitor and Control System of Granary Temperature and Humidity Based on ARM

Preliminary Design Report with Diagrams

PLC Based Washing Machine

RADIOCOMMUNICATIONS (EMC STANDARDS) NOTICE 2004 No. 2

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Performance Neuro-Fuzzy for Power System Fault Location

RE-PR3-E-27 3-Phase Panel Mount 27kW

Passive Infrared Perimeter Monitoring Alarm System

Guide Specification Model CTG Automatic Transfer Switch

Challenger Version 8 Programming Relays.

LIQUEFIED PETROLEUM GAS DIFFUSER Home automation based fire security.

Design and Development of Industrial Pollution Monitoring System using LabVIEW and GSM

Smart Office Automation System for Energy Saving

INTRODUCTION TO SENSORS AND ACTUATORS

August 2013 Technical Requirements for Remote Controlled Temporary Traffic Management Signs for use on the Highways Agency Strategic Road Network

Implementation of Automated Waste Segregator at Household Level

Mission 份有限公司 wwwom 先锋科技股份有限公司 www Working with our customers we identify, design and deliver low light detection solutions which solve customer probl

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Updated: September 12, 2018 DIVISION INTEGRATED AUTOMATION. INTEGRATED AUTOMATION Page 1 of INTEGRATED AUTOMATION

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

CERTIFICATION BULLETIN

BASIC-Tiger Application Note No. 029 Rev Waking up sleeping tigers. Gunther Zielosko. 1. Basics Real Time Clock

A Novel Approach to Garbage Management Using Internet of Things for Smart Cities

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

Philips Semiconductors

OPERATING MANUAL Enertronic Control System 2

Break-in Detector and Alarm System

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

SECTION AUTOMATIC TRANSFER SWITCHES

PIR MOTION SENSOR. PIR Motion Sensor (EKMB, EKMC, AMN2, 3)

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

The Remote alarm Panel, TYPE RAPv2

Designing A Home Automation System by Using RF Receivers

Design of an Infusion Rate Control System Based on Single Chip Microcomputer

Virtual Boundary System Using Passive Infrared Sensor

A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS

Networked Access Control Panel. Installation Guide

Transcription:

A COST EFFECTIVE APPROACH TO IMPLEMENTING CHANGE OVER SYSTEM Nwafor Chukwubuikem M. Electronics Development Institute, Awka, National Agency for Science and Engineering Infrastructure, Federal Ministry of Science and Technology, NIGERIA mcchuksonline@yahoo.co.uk Mbonu Ekene S. Electronics Development Institute, Awka, National Agency for Science and Engineering Infrastructure, Federal Ministry of Science and Technology, NIGERIA mbo_eke_sam@yahoo.com Uzedhe Godwin Electronics Development Institute, Awka, National Agency for Science and Engineering Infrastructure, Federal Ministry of Science and Technology, NIGERIA osmenawin22@yahoo.com ABSTRACT This paper reviewed the methods of implementing change over system and proposed a better and cost effective approach to realizing the same. Some of the approaches which have been employed to implement change over system include manual change over switch box, automatic change over system with electromechanical relays and change over system with automatic transfer switch. Each of the methods has some drawbacks that make it undesirable. Among these drawbacks are time wastage, possibility of fire outbreak, generation of noise, frequent failures, product damage, high component count to mention but a few. These contribute to the high cost of these methods. The approach proposed in this paper makes use of solid state relay(ssr) which eliminates totally the noise, arching, wear and tear associated with electromechanical relays. Digital integrated circuits and microcontroller were used to reduce the component count as well as improve the speed of the system. The system also has some desirable features like liquid crystal display (LCD) which makes the system user friendly, an alarm system for indicating generator failure, automatic phase selector for selecting most appropriate phase, over-voltage and under-voltage level monitoring. Keywords: electromechanical relays, Automatic phase selector, solid state relay, voltage level monitoring. INTRODUCTION Power instability in developing countries has necessitated the need for automation between public power supply and alternative generators to backup the utility power supply, and as the rate of power instability becomes predominantly high the need for automation also becomes high. And since most industrial and commercial processes require uninterrupted power supply, if the process of power supply changeover is manual, it will not only waste time by slowing the process, but could also cause device, process or product damage. There could also be error during the manual changeover as a result of human factor, and this in some cases can lead to massive loss of revenue. Therefore the major aim of this work is to exploit the ubiquitous microcontroller facilities in bringing about automation of changeover process. One of the most critical needs of an embedded system such as this is to decrease power consumption and space [7] and this 62

is achieved in this work. It has been observed over the years that power instability has caused companies to lose millions of dollar each time there is power failure, as a result of the time lag between power failures and when power is restored. This can be seen clearly in companies like telecommunications, breweries, cold rooms to mention but a few. This system was designed to proffer solution to the shortcomings of the already existing manual changeover by performing power swap from public power to generator automatically and vise-versa. It has the ability to eliminate the stress of manually switching on the generator when there is public power failure. REVIEW OF EXISTING WORK To ensure the continuity of power supply, many commercial/industrial facilities depend on both utility service and on-site generation (generator set). And because of the growing complexity of electrical systems it becomes imperative to give attention to power supply reliability and stability. Over the years many approaches have been implored in configuring a changeover system. Some of them are discussed below. Manual Changeover Switch Box Manual changeover switch box separates the source between a generator and public supply [4]. Whenever there is power failure, changeover is done manually by human and the same happens when the public power is restored and this is usually accompanied with loud noise and electrical sparks. Limitations of Manual Changeover Switch Box Below are some of the limitations of manual changeover switch box. (i) Time wasting whenever there is power failure (ii) It is strenuous to operate (iii) It is causes device, process or product damage (iv) It can cause fire outbreak (v) It makes a lot of noise. (vi) Maintenance is more frequent as the change over action causes wears and tears. Automatic Changeover System with Electromechanical Relays (EMRs) A relay is an electromagnetic device that is activated by varying its input in order to get a desired output. Relays are of two types, the normally closed and normally open [6]. Figure 1. Diagram of electromechanical relays. 63

Recently, electromechanical relays (EMRs) have been used with other component to implement automatic changeover. Such components can be logic gates, transistors, opto-coupler, microcontroller etc. Most of these components make use of 5v since they are Transistor Transistor Logic (TTL) based. Such control system must be properly isolated from the relay as shown in figure 2 to avoid the flow back of ac signal into the control electronics. ELECTRONICS CONTROL ISOLATOR EMRs MAINS LOAD Figure 2. Block diagram of automatic changeover system with electromechanical relay. This type of changeover system is better than the manual changeover with switch box because it is automatic and faster, but has its limitations which are listed below: Noise associated with switching of relays. Wear and tear. Arching which can cause fire outbreak. High Component count making the system more prone to failures. Changeover with Automatic Transfer Switch This type of changeover system has an automatic transfer switch [3], which monitors the alternating current (AC) voltage coming from the utility company line for power failure conditions. Upon detection of power failure for predetermined period of time, the standby generator is activated (started), after which the load is transferred from utility to the standby generator. Then, on return of the utility feed, the load is switched back after some time and the generator is stopped. The limitations of this approach are more or less the same thing with automatic changeover system with electromechanical relays. DESCRIPTION OF THE NEW SYSTEM In view of the limitations of the above previous works, this paper proposes and implements a change over systems that drastically reduced the shortcomings. The noise, arching, wear and tear associated with EMRs are eliminated totally by the introduction of solid state relay. Digital components were also used to make the work more reliable unlike the previously existing ones that make use of circuit breakers. Also an AT89C52 microcontroller was also incorporated to help improve the speed of automation. The system is 64

controlled by a software program embedded in the microcontroller. This work is handy and portable compared to the bulky works done previously. It also have some important features like liquid crystal display (LCD) which makes the system user friendly, an alarm system for indicating generator failure, automatic phase selector for selecting most appropriate phase, over-voltage and under-voltage level monitoring. Economically, this project is of low cost due to the use of ICs in place of discrete components. Description of Solid State Relays With emergence of semiconductor technology the production of solid state relays were made possible which in many applications out perform their predecessors. A typical solid state relay consists of a light emitting diode (LED) optically coupled to a photovoltaic device such as a Field Effect Transistor (FET). Light from the LED creates a voltage across the photovoltaic array and activates the output FET. FET is the preferred switching element in a solid state relay because it presents comparatively less electric resistant when it is in a conductive state than a triac in the same state and therefore generates less heat[9]. As a result of this, FET requires smaller heat dissipating fins and can reduce the overall size of the solid state relay. The internal circuitry of a typical solid state relay is shown figure 3 while figure 4 is a solid state relay from FOTEK: Fig. 3 The internal circuitry of a typical solid state relay Fig. 4 Solid state relay from FOTEK Advantages of Solid State Relay over Electromechanical Relay Solid state relay has the following properties which gave it an edge over the EMR: (1) It has no moving coil part. (2) It has long operating life. (3) Bounce-free operation. (4) It has immunity to electromagnetic interference. (5) It has high switching speed 65

(6) It can be controlled by a low signal (3v). (7) Multi function integration (8) No arching or sparking. (9) No acoustical noise. (10) High reliability. (11) Resistance to shock and vibration. (12) Wide input voltage range. (13) High input-output isolation [11]. Because of the low signal control feature, solid state relays can be driven directly by the microcontroller without the use of interface drivers. This can save space, time and money, reduce component count as well as improve product life, performance and reliability. IMPLEMENTATION OF MICROCONTROLLER_BASE AUTOMATIC CHANGEOVER WITH SOLID STATE RELAY Figure 5 shows the block diagram of the system. The implementation of this system was achieved by using the AT89C52 as the host controller. The microcontroller does the control through the software program embedded in it. The phase, over voltage and under voltage monitoring was achieved using the operational amplifier LM3914 interfaced to microcontroller. LM3914 is a single IC that has ten separate op-amps embedded in it [10]. Below is the summary of the operations of the entire system: The microcontroller monitors the mains supply through the phase selector, over/under voltage and mains failure units, and switches the appropriate phase to the load through the solid relay arrangement. In the case of total power failure, the system, sustained by back up battery, switches on a single phase generator, whose output is also connected to the load through the solid relay arrangement. The switching of the single phase generator is controlled by the generator control unit. In case of starting failure after three attempts, the system sounds an alarm and automatically goes to manual mode (where the user will have to start the generator manually after putting it in order). The system connects the load back to utility power and automatically turns off the generator as soon as utility power is restored. The liquid crystal display (LCD) displays all the activities of the system, making it user friendly. Flowchart and Schematic diagram of the System Figure 6 is a flowchart which represents the operation of the system. With the knowledge of this flow chart, a software program can be written to drive or control the action of the microcontroller. Figure 7 is the expanded schematic diagram of the system drawn in proteus environment. The bank of resistors and op-amps shown in the diagram can be replaced with a single LM3914 IC mentioned previously. 66

STEP DOWN/BACKUP BATTERY LIQUID CRYSTAL DISPLAY (LCD) MAINS FAILURE DETECTOR PHASE SELECTOR ALARM SYSTEM MAIN GENERATOR CONTROL UNIT GENERATOR SET OVER/UNDER VOLTAGE DETECTOR SOLID STATE RELAY ARRANGEMENT LOAD MICRO CONTROLLER (M/C) Figure. 5 Block diagram of microcontroller based automatic change over with solid state relays 67

Start Initialize the system Check the utility power supply utility power on Check the 3 phase voltage Clear Flag there utility supply Gen over ride On flag set Any of the phase Ok Switch Appropriate Phase ON and switch OFF gen Gen on Start Generator Gen on Inc count Count = 3 Activate alarm and display fault on LCD Figure: 6. Flowchart representing the system s operation Clear Count Set Flag 68

Fig 7: Expanded circuit diagram of microcontroller based automatic change over with solid state relays 69

TESTING AND RESULTS Table 1. Summary of tests and results Testing Expected Result Result Obtained The system should not attempt starting the generator despite the fact that there is no utility supply 1. Activate the generator override and off the utility power supply The system did not attempt starting the generator. 2. The power supply still off and generator override deactivated The system should attempt starting the generator. The system did attempt starting the generator. 3. The power supply still off and generator override deactivated and generator disengaged. 4. The power supply still off and generator override deactivated and generator engaged. The system should attempt starting the generator three (3) times and then sounds an alarm and display fault on LCD. The system should start the generator. The system immediately did start the generator three (3) times and alarm was sounded and the fault was displayed on LCD. The system actually started the generator immediately. 5. Switch on the utility power supply and activate the utility power override. 6. Switch on the utility power supply and deactivate the utility power override and reduce the mains to 170V using variable transformer. 7. Switch on the utility power supply and deactivate the utility power override and return the mains to 220V using variable transformer The system should not switch on any of the three (3) phases available from the utility supply. The system should not switch on any phase but puts on gen if gen is not on. The system should switch on any of the phase and switch off the gen. The system did not switch on any of the available three (3) phases available from the utility supply. The system did not switch on any of the available three (3) phases from the utility supply, but switch on the generator immediately when it was not on previously. The system switched on one of the phase and puts off the generator almost immediately. 70

DISCUSSION From the discussion so far it can be seen that the use of solid state relay in the implementation of microcontroller based automatic changeover has a number of advantages over the other devices used in changeover system implementation. It eliminates all the noise, arching, wear and tear associated with EMRs and manual changeover switch box. The microcontroller with its ability to execute millions of instruction within seconds has also helped to improve the speed of the automation besides miniaturizing the entire system. AREAS OF APPLICATION This system can be applied in areas where continuous power supply is needed such as homes, banks, industries, hospitals and so on. CONCLUSION This paper has been able to show that solid state relay is a better replacement for electromechanical relays in microcontroller based automatic changeover system. This paper also will definitely be of great help to researchers and students in the matters concerning a better and reliable switching device for automatic changeover system. 71

REFERENCES 1. Theraja B.L. and Theraja A.K. (2000). Electrical technology. S. Chand and Company Limited 2. David E. Johnson, John L. Hillburn, Johnny R. Johnson, Peter D. Scott( nd). Basic electronics circuit analysis. John Wiley and son sons, inc. Fifth edition. 3. Jerry C. Whitaker (nd). Electronic Handbook. (Cyclic Redundancy checks, CRC Press/Institute of Electronics Engineering, IEEE Press) page 1030 1031. 4. Jonathan Gana Kolo (2007). Design and Construction of an Automatic Power Changeover Switch. AUJ. T. II (2): 113 118 (October 2007). 5. M. A. Mazidi and J. G. Mazidi (2000). The 8051 Microcontroller and Embedded System: Prentice Hall Inc. 6. Paul Horowitz and Winfield Hill (nd). The art of electronics, Cambridge university press, second edition. 7. http://www.journal.au.edu/au_techno/2006/july06/vol10no1_a10.pdf 8. http://samplecode.rockwellautomation.com/idc/groups/literature/documents/at/700-at001_-ene.pdf 9. www.ip.com/patapp/ep0245769a1 10. www.pdf1.alldatasheet.com/datasheet-pdf/view/8898/nsc/lm3914.html 11. www.silicavalley.com/solidstaterelayj.b.gupta.2009/2010 72