Installation Guide. Disabled Persons Emergency Alarm Kit. Single Zone Call Control/Call answered unit c/w Sounder LED indicators and Braille lettering

Similar documents
Accessible Toilet Alarm

Disabled Persons Toilet Alarm Kit

Installation & Operating Instructions

Emergency Assist Alarm Kit Single Zone

Disabled persons toilet alarm kit from Cameo Systems

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Disabled Persons Toilet Alarm Kit

Door Release Power Supply

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Intelligent Security & Fire Ltd

User Operation Guide Document: VI49.2

New Silent Alert Fire Safe System

OPERATION AND INSTALLATION MANUAL

Silent Alert Fire Safe System

Control Panel User Guide

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

Installation, Operating and Maintenance Manual

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

USER MANUAL CEF AP28 CONTROL PANEL

100 Series Gas Ventilation Interlock System

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Electrisaver User and Installation Instructions

DISABLED TOILET / EMERGENCY ASSISTANCE ALARMS

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

WARNING FIRE DOOR CLOSING

Excel-EN Conventional Fire Control Panel

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

Intelligent Security & Fire Ltd

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Product Data Sheet. Merlin GDP2. Gas Safety Products. Merlin GDP2. Installation, operating and maintenance 23/08/2016. S&S Northern Ltd 1

FEC400 Series. Installation Manual

Emergency Voice Communication System (EVCS) Consu ltant s Specific atio n CONTENTS

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

Operating Instructions

USER MANUAL & MAINTENANCE GUIDE OG OO

Smoke Vent Control Panel PCB4 V4 Installation Manual

TIMEGUARD WEATHERSAFE OUTDOOR POWER RANGE INSTALLATION & OPERATING INSTRUCTIONS

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

KFP-CF Series Operation Manual

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

Gas Safety Products. Installation, operating and maintenance 28/10/2015. Merlin CT1250 Gas Interlock System. S&S Northern Ltd 1

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

EMERGENCY ASSISTANCE ALARMS

QA16 Addressable System

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

Control Panel Engineering and Commissioning Instructions

Panel Functions & Indicators - Key to Icons General & Zone Fire LEDs ACCEPT SOUNDERS START/ STOP RESET BUZZER MUTE KEYSWITCH DELAY ON/OFF ITEM SELECT

System 800 Addressable Fire Detection & Alarm System

NEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK.

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016

ZSC100 Gas Detection and Alarm System Controller

CW9000 Wireless Fire System. Installation Manual

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

SECURIT 700L PLUS ENGINEERING MANUAL

Electronic Dual Cylinder Thermostat Installation Instructions

Control Panel User Guide (TO BE RETAINED BY THE USER)

Surface Mount Wall PIR Light Controller. Model: PDWM1500. Installation & Operating Instructions

The complete conventional fire warning system

Model 3.6m. User Manual Original instructions

Application, Installation, Operation & Maintenance Manual

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:

Induction Fryer. Instruction manual. Model Modèle Modell Modello Modelo Malli: CP793

The EN54 Part 2 and 4 Fire System

SOLO Single Loop Addressable Fire Control Panel

WATER KETTLE INSTRUCTION MANUAL

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS

Intellia Sounder Bases and Sounder Beacon Bases

INSTRUCTION MANUAL (ATEX / IECEx)

Heated Display. Instruction manual. Model: CW147 / CW148

360 Ceiling PIR Light Controller

INSTALLATION MANUAL SECURIT 802 CONTROL PANEL

Operation and Maintenance Manual

Surveyor Envoy-MINI 4

COOKWORKS TWIN PROFESSIONAL FRYER INSTRUCTION MANUAL

RECESSED WARM CEILING HEATERS MODELS HSRCH3000RF, HSRCH4500RF INSTALLATION AND OPERATING MANUAL

FEC403EN Installation Manual

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

The EN54 Part 2 & 4 Fire System

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

Conventional Fire Control Panel

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Transcription:

Installation Guide Disabled Persons Emergency Alarm Kit Contents: Single Zone Call Control/Call answered unit c/w Sounder LED indicators and Braille lettering Remote Reset Unit c/w Sounder & call Answered LED indicators and Braille lettering. LED over door light/sounder Unit Ceiling Pull Switch with LED indicator Pull Handles Disabled WC Sticker Inactive sticker M3.5 Fixing screws IMPORTANT NOTES Read the full instructions before installing the equipment. 1

General Information and Safety Instructions Read This First Check the pack and confirm you have all of the parts listed. If not contact the outlet where you purchased this product As the buyer, installer and/or user of this product it is your own responsibility to ensure that this system is fit for the purpose for which you have intended it. Contactum cannot accept any liability for loss, damage or premature failure resulting from inappropriate use. This System must be installed and maintained by a competent person, In accordance with the Building Regulations, making reference to the current edition of the IEE Wiring Regulations (BS7671). The Batteries supplied with this unit are consumable parts and therefore may be outside of any warranty offered. Suitable for indoor use only electrical supply, the supply must conform with the requirements of the Building Regulations making reference to the current edition of the IEE wiring Regulations (BS7671). This product is designed for permanent connection to fixed wiring via a fused connection unit with a 3Amp fuse. Make connections to the electrical supply in accordance with the following code Live - Brown or Red Neutral Blue or Black Earth Green and Yellow You are advised at every stage of your installation to double-check any electrical connections you have made. After you have completed the installation there are electrical tests that should be carried out: these tests are specified in the wiring Regulations (BS7671). If in doubt consult a qualified electrician. When working at heights please use a suitable platform Do not attach to surfaces which are damp, freshly painted or otherwise electrically conductive (e.g. metallic surfaces). If the location of your new system requires the provision of a new 2

Specification Model Number DEA999 Mains Supply 230-240Vac 50Hz Rechargeable Battery back up 9V NiMH PP3 250mAh Sounder Sounder active in Alarm and call answered mode (Different intermittent sound in call answered mode 3 sec) Sound at 30cm Main controller 65db Remote reset 65db Over Door 78db Alarm output DC voltage through 1KΩ Resistor Visual Indicators Mains power on Fault Call answered Over door Main control panel Pull switch -Red LED -Amber LED -Green LED -Twin blue LED s flash continually when alarm has been activated -Blue LED flashes continually when alarm has been activated, -Blue LED flashes once every 3 seconds when call answer button has been pressed - Red LED intermittent when alarm active Unit Dimensions Main control unit Remote reset Over door light / sounder Pull cord switch 147 x 86.5 x 35mm 86.5 x 86.5 x 13mm 86.5 x 86.5 x 38mm 89.5mm diameter x 26.5mm 3

Designing a system The diagram below shows a typical layout for a good practise disabled person s toilet alarm system based on the recommendations of BS8300. It should be noted that the exact position of the devices shown can be varied to suit a particular application provided that the recommendations described are met. Other/alternative standards of design and installation should be adhered to where pertinent A typical BS8300 Clause Compliant Emergency Assistance Alarm All system components should be sited internally in areas where they are easily accessible by the person(s) designated to use them. 4

Installation Installation This disabled alarm kit contains a control panel that is mains voltage powered (230v) Which should be fed from an isolating switched fused connection unit rated at 3A which is marked appropriately and secure from unauthorised operation? All other items (pull switch, over door light/sounder, remote/call answered unit are connected in parallel by 2 core cables. Units that are to be connected can be done so in any order from the output terminal of the main control panel via the input/output terminals of the individual components. All low voltage wiring must be carefully planned before starting the job, always segregate low voltage wiring from mains cabling. All wall mounted devices should be mounted onto a back box of the required depth. Assess the condition and construction of all mounting surfaces prior to installation and use a suitable fixing arrangement. The recommended mounting height for reset buttons is between 750mm to 1200mm Powering up self test On initial power up the control unit will switch to diagnostic mode, if there are any problems the Amber fault LED will be illuminated (this indicates broken or damaged wiring) Volume Control A potentiometer on the printed circuit board of the main control panel will adjust the sounder volume Reset / Link A facility has been provided so that you can link out the reset button on the main control unit if required; this means if the alarm is activated then it can only be reset at the point of source i.e. the location where the alarm was triggered. If you choose to disable the reset function in the main control panel apply the Inactive sticker over the word reset on the front panel of the control unit. 5

Basic Operation The Person in need of assistance can activate the alarm by pulling the red cord The red LED will flash on the pull switch to show that the alarm has been activated The light/sounder that is sited outside the door will alert people that assistance is required The main control panel should be sited in an area where it can be heard and seen at all times, so that it will be noticed immediately if the alarm is triggered. When the alarm is triggered, the responding person can press the call answered button and this will change the tone of the alarm sounder and illuminate the green LED on the remote panel giving reassurance to the person in distress that assistance is on its way. Ensure the remote reset unit is sited in a convenient position within the WC area. Once the call answered button on the main panel has been pressed the unit will flash and give an intermittent alarm sound. Resetting the alarm The alarm can be reset/cancelled or call answered by pressing the appropriate button on the main control panel. The reset and call answered buttons are also marked in Braille. The alarm can be reset/cancelled by pressing the button on the remote unit that is sited in the WC area. 6

Wiring Diagram F U S E Incoming mains supply via 3 Amp switched connection unit L E N Battery TX LV Out Main Control Panel LV In LV Out Pull Cord LV In LV Out LV In Over door light buzzer unit Reset Unit LV = Low Voltage LV connections are not polarised i.e. no +Ve or Ve Components can be connected in any order from the LV output terminal of the Main control panel 7

Contactum Limited Victoria Works, Edgware Road Cricklewood, London, NW2 6LF T: 020 8208 7419 F: 020 8208 3340 sales@contactum.co.uk www.contactum.co.uk 8