PROPOSED CHANGE TO THE 2015 ONTARIO FIRE CODE (O. Reg. 213/07, as amended current to January 1, 2015)

Similar documents
PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED

Recent Revisions and Proposed Key Changes to Fire Code

BUILDING CODE COMMISSION

PROPOSED CHANGE TO THE 2007 FIRE CODE (OFC)

PROPOSED CHANGE TO THE 2007 FIRE CODE (OFC)

PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED

Short Term Accommodations Fire Code Requirements

DIVISION C ADMINISTRATIVE PROVISIONS

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

2012 OBC Changes. Summary of key changes to Life Safety and Fire Protection Systems for CFAA January 22, 2014

Interim Amendments to Ontario s 2012 Building Code Retirement Homes. August 17, 2017

BY-LAW AMENDING THE BY-LAW CONCERNING THE SERVICE DE SÉCURITÉ INCENDIE DE MONTRÉAL (RCG )

2014 Alberta Building Code. Part 9 changes relating to Smoke and CO Alarms

BUILDING CODE COMMISSION

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

Phase Two Change Proposal for the Next Edition of the Building Code: 2-CC-B POTENTIAL CHANGE TO ONTARIO S BUILDING CODE:

CFAA Technical Seminar Ontario Building Code Updates to 2015

OWNERS RESPONSIBILITIES & CASE STUDIES ONTARIO FIRE CODE. John Percy, Public Education Officer Waterloo Fire Rescue

Building Standards Advisory Promoting construction of safe, healthy, habitable buildings

ENERGY EFFICIENCY AFTER DECEMBER 31, 2016

Housing Division Notice

BUILDING CODE COMMISSION

Council of the City of York, PA Session 2008 Bill No. Ordinance No. INTRODUCED BY: Genevieve Ray DATE: November 18, 2008

VERIFICATION OF FIRE ALARM SYSTEMS

SOUTH AFRICAN NATIONAL STANDARD

Part 3 BUILDING CODE MYTHS & INTERPRETATIONS

CAN/ULC-S561. To comply, or not to comply. actually it s not even a question! Underwriters Laboratories of Canada. By Alan Cavers & Brian McBain

BUILDING CODE COMMISSION

SOMERSWORTH CODE FIRE PREVENTION AND LIFE SAFETY CHAPTER 21

Australian Standard. Smoke alarms. AS (Incorporating Amendment Nos 1, 2, 3 and 4) AS 3786

Oklahoma. 265: Incorporated national codes and standards The following national codes and standards are incorporated by reference:

WHEREAS, the City of Albany has adopted a Fire Prevention Regulations in the form of Chapter XI of the Albany Municipal Code; and

ORDINANCE NO NOW, THEREFORE, BE IT ENACTED BY THE CITY COUNCIL OF THE CITY OF FAIRBANKS, ALASKA, as follows:

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE, 2000 EDITION SECTIONS

BULLETIN BU/EL Revised August 11, 2015

2012 Ontario Building Code Update

Standard Operating Procedure Ottawa Fire Services. Fire Safety Plan Approval - Revised

ONTARIO REGULATION to be made under the. TECHNICAL STANDARDS AND SAFETY ACT, 2000 Amending O. Reg. 218/01 (UPHOLSTERED AND STUFFED ARTICLES)

Carbon Monoxide Detectors in New and Existing Buildings

Ministry of Community Safety and Correctional Services Questions and Answers Carbon Monoxide. arm Questions and Answers

Luminaires Part 2-4: Particular requirements Portable general purpose luminaires

Fire Chief/General Manager of Fire and Rescue Services

Fire Safety and Prevention: A Resource Guide for Child Welfare Professionals. Presenter Notes

November 17, Sent Via Electronic and Regular Mail

Environmental Planning and Assessment Amendment (Smoke Alarms) Regulation 2006

THE TOWNSHIP OF CRANBURY

Australian Standard. Emergency escape lighting and exit signs for buildings. Part 1: System design, installation and operation AS 2293.

This is a preview - click here to buy the full publication

CHANGES TO THE TEXT OF THE 2010 CODE BOOKS

ARLINGTON COUNTY, VIRGINIA

Date of Authorization May 26, 2005 BMEC Authorization BMEC Application # A

The course only requires the latest edition of the following documents: Building Code Compendium, Volume 1 and 2.

BUILDING CODE COMMISSION

SOUTH AFRICAN NATIONAL STANDARD

Module 9: Ontario Building Code Fire Fighting Provisions

BCBC 2012 CHANGES TO PART 3

Secretary of State determination under article 36 of the Fire Safety Order

ORDINANCE NO. _ THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning. Part 1: Fire AS 1670.

150 Eighth Street Zoning By-law Amendment Application Preliminary Report

Community Festival Permit Application - Cypriot Community of Toronto Inc. - Cultural and Wine Festival June 23 and 24, 2007

Electrical Tech Note 107

INTERNATIONAL STANDARD

2015 Recommended Building Code with Amendments. The Executive Committee of the Central Iowa Code Consortium does ordain as follows:

Single Room Occupancy Hotel Safety & Stabilization Task Force

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

CAN/ULC-S INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

Carbon Monoxide Alarm Update

Mt. Crested Butte Code

Smoke Alarms and Carbon Monoxide Alarms

Errata Package National Fire Code of Canada (NFC) Selected replacement pages have been produced for the NFC.

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2012 EDITION

Glenwood Springs Fire Protection District Amendments to the 2009 International Fire Code

Maryland Updates Smoke Alarm Law What You Need to Know

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

OAA Conference ,

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

(House Bill 849) Public Safety Rental Dwelling Units Carbon Monoxide Alarms

This document is a preview generated by EVS

Australian Standard. Components for the protection of openings in fire-resistant walls. Part 1: Fire-resistant doorsets AS AS 1905.

CSA B Code Installation Code for Oil-Burning Equipment Yukon Housing Contractor s Breakfast March 2014 Presented by Ron Bramadat, Ken Alaric &

AS/NZS :2015. Plumbing and drainage AS/NZS :2015. Part 4: Heated water services. Australian/New Zealand Standard

ORDINANCE NO. Establishing Fire and Life Safety Requirements for Existing Multi-Family Residential Buildings Classified as Group R, Division Occupancy

CITY CLERK. Removal of Fire Alarm Pull Stations Shuter Street and 15 Tobermory Drive

Drexel Heights Fire District 2012 International Fire Code Amendments

TEN STEP PROCESS PREPARING FIRE SAFETY PLANS

AS/NZS :2009. Performance of household electrical appliances Refrigerating appliances AS/NZS :2009

COMMISSION IMPLEMENTING REGULATION (EU) /... of XXX

Environmental testing Part 3-6: Supporting documentation and guidance Confirmation of the performance of temperature/humidity chambers

ELECTRICAL BULLETIN

INTERNATIONAL STANDARD

VILLAGE OF DOWNERS GROVE Report for the Village Council Meeting

THE CORPORATION OF THE TOWN OF OAKVILLE BY-LAW NUMBER

REVISION RECORD FOR THE STATE OF CALIFORNIA ERRATA

150 Elgin - Office Tower and Grant House Renovations

BY-LAW CONCERNING THE SERVICE DE SÉCURITÉ INCENDIE DE MONTRÉAL. In view of section 62 of the Municipal Powers Act (R.S.Q., chapter C-47.

Australian/New Zealand Standard

CITY OF PALM BEACH GARDENS ORDINANCE NO. 12, 2002

First Revision No. 88-NFPA [ Section No. 2.4 ] Submitter Information Verification. Committee Statement. 3 of /21/2013 1:03 PM

Transcription:

PROPOSED CHANGE TO THE 2015 ONTARIO FIRE CODE (O. Reg. 213/07, as amended current to January 1, 2015) CHANGE NUMBER: CODE REFERENCE: Division B, Sentences 2.13.2.1.(2), 2.13.2.1.(3) DESCRIPTION OF PROPOSED CHANGE: Adding new specifications for battery-operated smoke alarms. X Add a new requirement X Making a technical change to an existing requirement X Making an editorial/administrative change to an existing requirement between the overcurrent device and the smoke alarm, or (b) be battery-operated. EXISTING OFC PROVISIONS (3) A smoke alarm shall meet the requirements of CAN/ULC-S531, Standard for Smoke Alarms. 2.13.2.1. (1) A smoke alarm shall be installed (a) if a sleeping area in a dwelling unit is served by a hallway, in the hallway, (b) if a sleeping area in a dwelling unit is not served by a hallway, between the PROBLEM sleeping area and the remainder of the dwelling unit, (c) if a sleeping room is not within a dwelling unit, in the sleeping room, and A review (d) of on Ontario each storey fire loss without statistics a sleeping for the area years in 2006 a dwelling - 2015 unit. revealed that close to 10% (2) A of smoke fatal residential alarm shall fires occurred in homes where the smoke alarm did not operate because (a) the be battery permanently was either connected dead to or an missing. electrical Battery-operated circuit with no disconnect smoke alarms switch are only effective if the battery is properly maintained; however, this is contingent upon owners/occupants being aware of maintenance requirements and taking action to replace batteries when necessary. Although public education efforts have raised awareness of smoke alarm maintenance requirements, a significant number of residential fire deaths continue to occur in homes where smoke alarms are not operational. Emergency Management Page 1 of 3 2018 Amendments

PROPOSED OFC CHANGE Note for Proposed OFC Change: Black indicates existing text. Red underline indicates new text. Red strikethrough indicates existing text that is being deleted. 2.13.2.1. (1) [Unchanged] (2) A smoke alarm shall (a) be permanently connected to an electrical circuit with no disconnect switch between the overcurrent device and the smoke alarm, or (b) be battery operated powered by a non-removable, non-replaceable battery that is capable of powering the smoke alarm for a minimum of ten years. (3) A battery-operated smoke alarm installed prior to January 1, 2019, is deemed to be in compliance with Clause (2)(b) and may remain in-service until the smoke alarm is required to be replaced as per Article 6.3.3.7. (4) A smoke alarm shall meet the requirements of CAN/ULC-S531, Standard for Smoke Alarms. PROPOSED IN FORCE DATE January 1, 2019 RATIONALE FOR CHANGE This proposed change aligns with changes being proposed to Article 6.3.3.7. and proposed new Subsection 9.1.5. for both new and replacement battery-operated smoke alarms. Where smoke alarms are battery-operated, introducing new requirements for both; a non-removable, non-replaceable battery as well as a long-life battery that is capable of powering the smoke alarm for a minimum of ten years, will facilitate smoke alarm maintenance and reduce instances of dead or missing batteries. The non-removable, non-replaceable battery feature will address instances where smoke alarms are found to have no battery. In these types of smoke alarms, a battery is sealed in the housing by the manufacturer before distribution to the marketplace. A 10-year battery is required in a smoke alarm which is powered by a non-removable battery per CAN/ULC-S531-14. The long-life (10-year) battery feature will address instances where smoke alarms are found to have a dead battery as these batteries have an extended life that aligns with the life of the alarm which is 10 years per CAN/ULC-S531-14. Emergency Management Page 2 of 3 2018 Amendments

IMPACT This change will impact residential occupancies where smoke alarms are required and permitted to be battery-operated under the Fire Code. Proposed requirements would only apply to new smoke alarm installations and where existing smoke alarms that have either reached end of life or have been damaged are being replaced. New requirements are anticipated to simplify maintenance requirements. Over a 10 year life span, it is anticipated that the cost of a non-removable, nonreplaceable, long-life battery-operated smoke alarm will be less than that of a smoke alarm with replaceable batteries. Although cost will be slightly more at the point of purchase, there will be no annual costs associated with replacing batteries. This change will increase demand for battery-operated smoke alarms that specifically have non-removable, non-replaceable, long-life battery features. As such, it may impact existing smoke alarm inventories of manufacturers, retailers, wholesalers, etc. As the market may require an adjustment period, it is being proposed that the compliance date for this new requirement take effect on January 1, 2019. OBJECTIVE BASED ANALYSIS OF THE CHANGE OR NEW PROVISION FUNCTIONAL STATEMENT(S) AND LINK(S) TO OBJECTIVE(S) 2.13.2.1.(2)(b) - [F81-OS1.4] 2.13.2.1.(3) - 2.13.2.1.(4) - [F11-OS1.5, F81-OS1.4] Emergency Management Page 3 of 3 2018 Amendments

PROPOSED CHANGE TO THE 2015 ONTARIO FIRE CODE (O. Reg. 213/07, as amended current to January 1, 2015) CHANGE NUMBER: CODE REFERENCE: Division B, 6.3.3.7. DESCRIPTION OF PROPOSED CHANGE: Adding new specifications for battery-operated smoke alarms that are being replaced. Add a new requirement Making a technical change to an existing requirement X Making than that an required editorial/administrative by the Building Code change in effect to an at existing the time requirement of construction of the suite, and (c) in the case of a suite not subject to Part 9 that was constructed before EXISTING April OFC 6, 1998, PROVISIONS the replacement shall not provide a lower level or type of protection than that required by Article 2.13.2.1. (3) The Chief Fire Official may approve an alternative to a requirement of Sentence 6.3.3.7. (1) A smoke alarm shall be replaced within the time frame indicated in (2) if, in the opinion of the Chief Fire Official, the alternative provides fire safety the manufacturer s instructions. protection (2) When equivalent a smoke alarm to or greater is replaced than the fire safety protection that would be provided by the requirement. (a) in the case of a suite subject to Part 9, the replacement shall not provide a lower level or type of protection than that required by Part 9, (b) in the case of a suite not subject to Part 9 that was constructed on or after PROBLEM April 6, 1998, the replacement shall not provide a lower level or type of protection A review of Ontario fire loss statistics for the years 2006-2015 revealed that nearly 10% of fatal residential fires occurred in homes where the smoke alarm did not operate because there was either a dead battery or no battery. Battery-operated smoke alarms are only effective if the battery is properly maintained; however, this is contingent upon owners/occupants being aware of maintenance requirements and taking action to replace batteries when necessary. Although public education efforts Emergency Management Page 1 of 3 2018 Amendments

have raised awareness of smoke alarm maintenance requirements, a significant number of residential fire deaths continue to occur in homes where smoke alarms are not operational. PROPOSED OFC CHANGE Note for Proposed OFC Change: Black indicates existing text. Red underline indicates new text. 6.3.3.7. (1) [Unchanged] (2) [Unchanged] (3) As of January 1, 2019, a battery-operated smoke alarm being replaced in accordance with Sentence (2) shall be replaced with a smoke alarm which is powered by a non-removable, non-replaceable battery that is capable of powering the smoke alarm for a minimum of ten years. (4) The Chief Fire Official may approve an alternative to a requirement of Sentences (2) and (3) if, in the opinion of the Chief Fire Official, the alternative provides fire safety protection equivalent to or greater than the fire safety protection that would be provided by the requirement. PROPOSED IN FORCE DATE January 1, 2019 RATIONALE FOR CHANGE This proposed change aligns with changes being proposed to Article 2.13.2.1. and proposed new Subsection 9.1.5. for both new and replacement battery-operated smoke alarms. Where smoke alarms are battery-operated, introducing new requirements for both; a non-removable, non-replaceable battery as well as a long-life battery that is capable of powering the smoke alarm for a minimum of ten years, will facilitate smoke alarm maintenance and reduce instances of dead or missing batteries. The non-removable, non-replaceable battery feature will address instances where smoke alarms are found to have no battery. In these types of smoke alarms, a battery is sealed in the housing by the manufacturer before distribution to the marketplace. A 10-year battery is required in a smoke alarm which is powered by a non-removable battery per CAN/ULC-S531-14. Emergency Management Page 2 of 3 2018 Amendments

The long-life (10-year) battery feature will address instances where smoke alarms are found to have a dead battery as these batteries have an extended life that aligns with the life of the alarm which is 10 years per CAN/ULC-S531-14. IMPACT Over a 10 year life span, it is anticipated that the cost of a non-removable, nonreplaceable, long-life battery-operated smoke alarm will be comparable to or less than that of a smoke alarm with replaceable batteries. Although cost will be slightly more at the point of purchase, there will be no annual costs associated with replacing batteries. This change will impact residential occupancies where smoke alarms are required and permitted to be battery-operated under the Fire Code. Proposed requirements would only apply where existing smoke alarms are being replaced. New requirements are anticipated to simplify maintenance requirements. This change will increase demand for battery-operated smoke alarms that specifically have non-removable, non-replaceable, long-life battery features. As such, it may impact existing smoke alarm inventories of manufacturers, retailers, wholesalers, etc. As the market may require an adjustment period, it is being proposed that the compliance date for this new requirement take effect on January 1, 2019. OBJECTIVE BASED ANALYSIS OF THE CHANGE OR NEW PROVISION FUNCTIONAL STATEMENT(S) AND LINK(S) TO OBJECTIVE(S) 6.3.3.7.(3) - [F82-OS1.4] 6.3.3.7.(4) - [] Emergency Management Page 3 of 3 2018 Amendments

PROPOSED CHANGE TO THE 2015 ONTARIO FIRE CODE (O. Reg. 213/07, as amended current to January 1, 2015) CHANGE NUMBER: CODE REFERENCE: Division B, New Subsection 9.1.5. DESCRIPTION OF PROPOSED CHANGE: Adding new specifications for battery-operated smoke alarms that are being added or replaced. X Add a new requirement Making a technical change to an existing requirement Making an editorial/administrative change to an existing requirement EXISTING OFC PROVISIONS Not Applicable. PROBLEM A review of Ontario fire loss statistics for the years 2006-2015 revealed that nearly 10% of fatal residential fires occurred in homes where the smoke alarm did not operate because there was either a dead battery or no battery. Battery-operated smoke alarms are only effective if the battery is properly maintained; however, this is contingent upon owners/occupants being aware of maintenance requirements and taking action to replace batteries when necessary. Although public education efforts have raised awareness of smoke alarm maintenance requirements, a significant number of residential fire deaths continue to occur in homes where smoke alarms are not operational. PROPOSED OFC CHANGE Note for Proposed OFC Change: Red underline indicates new text. Subsection 9.1.5. 9.1.5. Sealed Long-life Battery-Operated Smoke Alarm Requirements 9.1.5.1. (1) Battery-operated smoke alarms permitted in Articles 9.3.4.2., 9.5.4.5., 9.6.4.10., 9.7.4.3., 9.8.4.2. and 9.9.4.13. shall be powered by a non-removable, Emergency Management Page 1 of 3 2018 Amendments

non-replaceable battery that is capable of providing power to the smoke alarm for a minimum of ten years. (2) Battery-operated smoke alarms installed prior to January 1, 2019 are deemed to be in compliance with Sentence (1) and may remain in-service until the smoke alarm is required to be replaced as per Article 6.3.3.7. PROPOSED IN FORCE DATE January 1, 2019 RATIONALE FOR CHANGE This proposed change aligns with changes being proposed to Article 2.13.2.1. and Article 6.3.3.7. for both new and replacement battery-operated smoke alarms. Where smoke alarms are battery-operated, introducing new requirements for both a sealed, non-removable, non-replaceable battery as well as a long-life battery that is capable of powering the smoke alarm for a minimum of ten years, will facilitate smoke alarm maintenance and reduce instances of dead or missing batteries. The non-removable, non-replaceable battery feature will address instances where smoke alarms are found to have no battery. In these types of smoke alarms, a battery is sealed in the housing by the manufacturer before distribution to the marketplace. A 10-year battery is required in a smoke alarm which is powered by a non-removable battery per CAN/ULC-S531-14. The long-life (10-year) battery feature will address instances where smoke alarms are found to have a dead-battery as these batteries have an extended life that aligns with the life of the alarm which is 10 years per CAN/ULC-S531-14. IMPACT This change will impact residential occupancies where smoke alarms are required and permitted to be battery-operated under the Fire Code. Proposed requirements would only apply to new smoke alarm installations and where existing smoke alarms are being replaced. New requirements are anticipated to simplify maintenance requirements. Over a 10 year life span, it is anticipated that the cost of a non-removable, nonreplaceable, long-life battery-operated smoke alarm will be either comparable to or less than that of a smoke alarm with replaceable batteries. Although cost will be slightly more at the point of purchase, there will be no annual costs associated with replacing batteries. Emergency Management Page 2 of 3 2018 Amendments

This change will increase demand for battery-operated smoke alarms that specifically have non-removable, non-replaceable, long-life battery features. As such, it may impact existing smoke alarm inventories of manufacturers, retailers, wholesalers, etc. As the market may require an adjustment period, it is being proposed that the compliance date for this new requirement take effect on January 1, 2019. OBJECTIVE BASED ANALYSIS OF THE CHANGE OR NEW PROVISION FUNCTIONAL STATEMENT(S) AND LINK(S) TO OBJECTIVE(S) 9.1.5.1.(1) [F81-OS1.4] 9.1.5.1.(2) Not Applicable. Emergency Management Page 3 of 3 2018 Amendments

PROPOSED CHANGE TO THE 2015 ONTARIO FIRE CODE (O. Reg. 213/07, as amended current to January 1, 2015) CHANGE NUMBER: CODE REFERENCE: Division B, 1.2.1.A. DESCRIPTION OF PROPOSED CHANGE: Add new referenced standard. Add a new requirement X Making a technical change to an existing requirement Making an editorial/administrative change to an existing requirement EXISTING OFC PROVISIONS Table 1.2.1.A. reference to CAN/ULC-S531-02 Issuing Agency Document Number Title of Document Code Reference ULC CAN/ULC-S531-02 Standard for Smoke 2.13.2.1.(3) Alarms 9.5.4.5.(3) 9.6.4.10.(3) 9.7.4.3.(4) 9.8.4.2.(3) 9.9.4.13.(2) PROBLEM The current referenced edition of CAN/ULC-S531 Standard for Smoke Alarms does not address sealed long-life battery requirements for smoke alarms. PROPOSED OFC CHANGE Note for Proposed OFC Change: Black indicates existing text. Red underline indicates new text. Emergency Management Page 1 of 2 2018 Amendments

Issuing Agency Document Number Title of Document Code Reference ULC CAN/ULC-S531-14 Standard for Smoke 2.13.2.1.(4) Alarms 9.5.4.5.(3) 9.6.4.10.(3) 9.7.4.3.(4) 9.8.4.2.(3) 9.9.4.13.(2) PROPOSED IN FORCE DATE January 1, 2019 RATIONALE FOR CHANGE The Ontario Fire Code (OFC) is being revised to introduce sealed long-life battery requirements for battery-operated smoke alarms. The ULC standard currently referenced in Table 1.2.1.A of Division B does not address sealed long-life battery requirements whereas these requirements are addressed in the 2014 edition of the standard. A consequential amendment will also be required to Article 1.2.1.1. of Division B to clarify that the new referenced standard will only apply to smoke alarms installed as of January 1, 2019. The existing reference to CAN/ULC-S531-02 will continue to apply to existing smoke alarms. IMPACT OBJECTIVE BASED ANALYSIS OF THE CHANGE OR NEW PROVISION FUNCTIONAL STATEMENT(S) AND LINK(S) TO OBJECTIVE(S) Emergency Management Page 2 of 2 2018 Amendments