Air Conditioners. Technical Data FTXS-G

Similar documents
EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3

Air Conditioners Technical Data

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXG-JW

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

Air Conditioners Technical Data

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)

Air Conditioners. Technical Data FTY-H

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

Air Purifiers. Technical Data MC70L

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN FDXM-F

Air Conditioners Technical Data

Full range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps. FTXS-G

Designed. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

technical data air conditioning systems FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit Split Sky Air

Air Conditioning. Technical Data EEDEN RXS-F8

Pure comfort & design

Air conditioners Heating & Cooling

Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA100AUVEB

Air Conditioners Technical Data

w w w. d a i k i n. e u ATXS-E

Air conditioners Heating & Cooling

Pure comfort & design

Air Conditioners Technical Data

Fan Coil Units. Technical Data FWC-BT/BF

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

Air Conditioning. Technical Data. 4-way blow ceiling mounted cassette EEDEN ACQ-C

EEDEN technical data EKRTR. Altherma. Altherma

for your home FTXS-G WALL MOUNTED UNIT

Air Conditioning. Technical Data. Ceiling suspended unit EEDEN AHQ-C

Air Conditioning. Technical Data EEDEN AZQS-BV1

Daikin air conditioners for your home

Pure comfort & design

Air Conditioners. Technical Data RZQG-L

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

Daikin air conditioners for your home

Heating. Technical Data EEDEN ERRQ-AY1

Daikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Pure comfort & design

Daikin air conditioners for your home

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

Air Conditioning. Technical Data. Small concealed ceiling unit EEDEN FDBQ-B

Air Conditioners. Technical Data FBQ-C

Remote control infrared ARC433B76 ARC433A8 ARC433B69

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

for your home FTYN-GX FT(Y)N-F

BENEFIT FROM LOWER FUEL COSTS.

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

technical data air conditioning systems Indoor Units FBQ-C7VEB

Air conditioners, heating & cooling for shops,restaurants and offices

Chillers. Technical Data. EWYD-BZ 250~580 kw

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

technical data air conditioning systems Indoor Units FCQ-C8VEB

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

DAIKIN EMURA. FORM. FUNCTION. REDEFINED. THE NEW INDOOR AIR CONDITIONING UNIT FROM DAIKIN.

for your home FLXS-B Flexi type unit air to air heat pumps

Air conditioners, heating & cooling for the retailmarket and offices

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

for small rooms in multi application

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

AIR CONDITIONERS, HEATING & COOLING for your home

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

Commercial and Technical Data

Daikin Sensira. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Air Conditioners Heating & Cooling

where innovation meets creativity

Air Conditioners Heating & Cooling

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8

Air Conditioners Heating & Cooling

FWV 04 FWL 05 FWM 06 FWB 07 FWD 08. Control 09. Accessories 10. Daikin Europe N.V.

EDUS Heat Pump - D-Series

Air Conditioning. Technical Data. Low temperature hydrobox for VRV EEDEN HXY-A

for the retail market, hotels, restaurants and offices

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

emura Form. function. redefined.

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Air Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A

Daikin air conditioners for your home, shops, restaurants and offices

GAS CONDENSING BOILERS RELIABILITY AND PEACE OF MIND

Air Conditioners Heating & Cooling

High temperature heating system AIR TO WATER HEAT PUMPS. Renovation - Heating - Domestic hot water

DAIKIN Air Handling Unit Modular

Air Conditioners Heating & Cooling

Air conditioners Heating & Cooling

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

Transcription:

Air Conditioners Technical Data I n d o o r u n i t s w w w. d a i k i n. e u FTXS-G

Air Conditioners Technical Data I n d o o r u n i t s w w w. d a i k i n. e u FTXS-G

Indoor Units R-410A FTXS-G TABLE OF CONTENTS FTXS-G 1 Features............................................................. 2 2 Specifications....................................................... 3 Technical Specifications............................................. 3 Electrical Specifications.............................................. 5 3 Dimensional drawing & centre of gravity........................ 6 Dimensional drawing................................................. 6 Centre of gravity..................................................... 8 4 Piping diagram...................................................... 9 5 Wiring diagram..................................................... 11 Wiring diagram...................................................... 11 6 Sound data......................................................... 12 Sound pressure spectrum........................................... 12 Split Sky Air Indoor Units 1

t i y n k r t o 0- i o 1 ld 4 n pt- FI Indoor Units R-410A FTXS-G 1 Features U S A G S X RS ECONO mode decreases power consumption so that other appliances that need large power supply can be used Night set mode saves energy by preventing overcooling or overheating during night time Powerful mode can be selected for rapid cooling or heating Whisper quiet operation: down to 22dBA sound pressure level (Only for FTXS 20,25,35,42,50G) Indoor / outdoor unit silent operation: "Silent" buttons on the remote control lower the operation sound of the indoor and/or outdoor unit by 3dBA Night quiet mode automatically reduces the operation sound of the outdoor unit by 3dBA during nighttime (multi outdoors in cooling mode only) (Only for FTXS 20,25,35,42,50G) 3D air flow combines vertical and horizontal auto-swing to circulate a stream of warm/cool air right to the corners of even large spaces 2 area intelligent eye: air flow is sent to the area in a room where no person is detected Energy saving during stand by mode: reduction of energy from 10W to 2W Weekly timer: allows to program the unit on a weekly basis Comfort mode reassures draught free operation Powerful mode can be selected for rapid cooling or heating Titanium apatite photocatalytic air purification filter absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses 5 steps optional (integrated titanium apatite) 2 Split Sky Air Indoor Units

Indoor Units R-410A FTXS-G 2 Specifications 2-1 Technical Specifications FTXS20G2V1B FTXS25G2V1B FTXS35G2V1B FTXS42G2V1B FTXS50G2V1B Casing Colour White Dimensions Packing Height mm 366 366 366 366 366 Width mm 870 870 870 870 870 Depth mm 274 274 274 274 274 Unit Height mm 295 295 295 295 295 Width mm 800 800 800 800 800 Depth mm 215 215 215 215 215 Weight Unit kg 9 9 10 10 10 Packed Unit kg 13 13 13 13 13 Heat Exchanger Dimensions Length mm 605 605 605 + 602.7 605 + 602.7 605 + 602.7 Nr of Rows 2 2 2 + 1 2 + 1 2 + 1 Fin Pitch mm 1.2 1.2 1.2 + 1.6 1.2 + 1.6 1.2 + 1.6 Nr of Stages 18 18 18 + 12 18 + 12 18 + 12 Tube type ø6.35 Hi-XU Fin Type ML fin (Multi louvre) Fan Type Cross flow fan Air Flow Rate High m³/min 9.4 9.1 10.4 9.1 10.2 Medium m³/min 7.4 7.1 7.7 7.7 8.6 Low m³/min 5.5 5.2 4.8 6.3 7.0 Silent Operation m³/min 4.0 3.7 3.5 5.4 6.0 High m³/min 9.9 9.8 10.6 11.2 11.0 Medium m³/min 8.2 7.9 8.5 9.4 9.3 Low m³/min 6.5 6.2 6.4 7.7 7.6 Silent Operation m³/min 5.5 5.2 5.4 6.8 6.7 High cfm 332 321 367 321 360 Medium cfm 262 252 270 273 305 Low cfm 193 182 170 221 246 Silent Operation cfm 141 130 125 190 212 High cfm 350 346 374 395 388 Medium cfm 290 280 302 333 330 Low cfm 228 217 226 271 267 Silent Operation cfm 193 183 191 240 236 Fan Motor Model KFD-280-23-8A Number of steps 5 steps, silent and auto Motor Speed (cooling) High rpm 1,150 1,150 1,370 1,310 1,390 Medium rpm 950 950 1,090 1,170 1,230 Low rpm 750 750 800 1,020 1,060 Silent Operation rpm 600 600 670 930 960 Speed (heating) High rpm 1,200 1,220 1,370 1,410 1,440 Medium rpm 1,030 1,030 1,160 1,230 1,270 Low rpm 850 850 940 1,050 1,090 Silent Operation rpm 750 750 840 960 1,000 Fan Motor Output (high) W 23 23 23 23 23 Sound Power High dba 54 54 58 58 59 Sound Pressure High dba 38 38 42 42 43 Medium dba 32 32 34 38 39 Low dba 25 25 26 33 34 Silent Operation dba 22 22 23 30 31 Sound Power High dba 54 55 58 58 60 Sound Pressure High dba 38 39 42 42 44 Medium dba 33 34 36 38 39 Low dba 28 28 29 33 34 Silent Operation dba 25 25 26 30 31 Refrigerant Type R-410A Piping connections Liquid (OD) Diameter (OD) mm 6.35 6.35 6.35 6.35 6.35 Gas Diameter (OD) mm 9.52 9.52 9.52 9.52 12.7 Drain Diameter (OD) mm 18 18 18 18 18 Heat Insulation Both liquid and gas pipes Split Sky Air Indoor Units 3

Indoor Units R-410A FTXS-G 2 Specifications 2-1 Technical Specifications FTXS20G2V1B FTXS25G2V1B FTXS35G2V1B FTXS42G2V1B FTXS50G2V1B Air Filter Removable/washable/Mildew proof Air direction control Right, Left, Horizontal, Downward Temperature control Microcomputer control Standard Titanium apatite photocatalytic air purification filter Accessories Quantity 2 2 2 2 2 Operation manual Quantity 1 1 1 1 1 Installation manual Quantity 1 1 1 1 1 Wireless remote control Quantity 1 1 1 1 1 Batteries Quantity 2 2 2 2 2 Remote control holder Quantity 1 1 1 1 1 Indoor unit fixing screws Quantity 2 2 2 2 2 Mounting plate Quantity 1 1 1 1 1 2-1 Technical Specifications FTXS60GV1B FTXS71GV1B Casing Colour White Dimensions Packing Height mm 361 361 Width mm 1,145 1,145 Depth mm 364 364 Unit Height mm 290 290 Width mm 1,050 1,050 Depth mm 250 250 Weight Unit kg 12 12 Packed Unit kg 18 18 Heat Exchanger Dimensions Length mm 863 863 Nr of Rows 2 2 Fin Pitch mm 1.4 1.4 Nr of Stages 16 16 Tube type ø7 Hi-XD Fin Type ML fin (Multi louver) Fan Type Cross flow fan Air Flow Rate High m³/min 16.0 17.2 Medium m³/min 13.5 14.5 Low m³/min 11.3 11.5 Silent Operation m³/min 10.1 10.5 High m³/min 17.2 19.5 Medium m³/min 14.9 16.7 Low m³/min 12.6 14.2 Silent Operation m³/min 11.3 12.6 High cfm 565 607 Medium cfm 447 512 Low cfm 399 406 Silent Operation cfm 357 371 High cfm 607 689 Medium cfm 526 590 Low cfm 445 501 Silent Operation cfm 399 445 Fan Motor Model ARW3001DA Number of steps 5 steps, silent and auto 4 Split Sky Air Indoor Units

Indoor Units R-410A FTXS-G 2 Specifications 2-1 Technical Specifications FTXS60GV1B FTXS71GV1B Motor Speed (cooling) High rpm 1,330 1,410 Medium rpm 1,170 1,220 Low rpm 1,010 1,040 Silent Operation rpm 920 950 Speed (heating) High rpm 1,360 1,520 Medium rpm 1,200 1,330 Low rpm 1,040 1,150 Silent Operation rpm 950 1,040 Fan Motor Output (high) W 43 43 Sound Power High dba 61 62 Sound Pressure High dba 45 46 Medium dba 41 42 Low dba 36 37 Silent Operation dba 33 34 Sound Power High dba 60 62 Sound Pressure High dba 44 46 Medium dba 40 42 Low dba 35 37 Silent Operation dba 32 34 Air Filter Removable/washable/Mildew proof Air direction control Right, Left, Horizontal, Downward Temperature control Microcomputer control Standard Titanium apatite photocatalytic air purification filter Accessories Quantity 2 Operation manual Quantity 1 Installation manual Quantity 1 Infrared remote control Quantity 1 Batteries Quantity 2 Remote control holder Quantity 1 Indoor unit fixing screws Quantity 2 Mounting plate Quantity 1 2-1 Electrical Specifications FTXS20G2V1B FTXS25G2V1B FTXS35G2V1B FTXS42G2V1B FTXS50G2V1B Power Supply Name V1 Phase 1~ Frequency Hz 50 50 50 50 50 Voltage V 220-230-240 Current Nominal running A 0.09-0.08-0.08 0.09-0.08-0.08 0.12-0.12-0.11 0.11-0.11-0.10 0.12-0.12-0.11 current (RLA) A 0.10-0.10-0.09 0.10-0.10-0.09 0.13-0.13-0.12 0.14-0.14-0.13 0.15-0.14-0.14 Wiring connections For Power Supply Quantity 3 3 3 3 3 2-2 Electrical Specifications FTXS60GV1B FTXS71GV1B Power Supply Name V1 Phase 1~ Frequency Hz 50 Voltage V 220-240 Current Nominal running A 0.18 0.20 current (RLA) A 0.20 0.27 Wiring connections For Power Supply Quantity 3 for power supply, 4 for interunit wiring (Earth wire included) Split Sky Air Indoor Units 5

Indoor Units R-410A FTXS-G 3 Dimensional drawing & centre of gravity 3-1 Dimensional drawing FTXS20-42G The mark ( ) shows piping direction Air flow (Indoor) Rear Left Right Including mounting plate 30 Min Space for performance Front panel fixed screws (inside) 50 Min Space for maintenance Name plate Terminal block with earth terminal REQUIRED SPACE 50 Min Space for maintenance Bottom Flaps Signal transmitter Signal receiver Model name plate Up/down (Automatic), dry Intelligent eye sensor Operation lamp Timer lamp Intelligent eye lamp Indoor unit ON/OFF switch Room temp. thermistor (Inside) BLADE ANGLES Fan Gas pipe Ø9.5 CuT (The length of pipe outside the unit: about 350) Liquid pipe Ø6.4 CuT (The length of pipe outside the unit: about 400) Drain hose (Connecting part I.D. Ø14 O.D. Ø18 The hose length of outside the unit is approx. 465) INFRARED REMOTE CONTROL (ARC452A3) FTXS50G The mark ( ) shows piping direction Right/left (automatic) Air flow (Indoor) Wall hole for embedded piping Ø65 hole STANDARD LOCATIONS OF WALL HOLES Wall hole Ø65 hole 3D058919A Rear Left Right Including mounting plate 30 Min Space for performance Front panel fixed screws (inside) 50 Min Space for maintenance Name plate Terminal block with earth terminal REQUIRED SPACE 50 Min Space for maintenance Bottom Flaps Signal transmitter Signal receiver Model name plate Up/down (Automatic), dry Intelligent eye sensor Operation lamp Timer lamp Intelligent eye lamp Indoor unit ON/OFF switch Room temp. thermistor (Inside) BLADE ANGLES Fan Gas pipe Ø12.7 CuT (The length of pipe outside the unit: about 350) Liquid pipe Ø6.4 CuT (The length of pipe outside the unit: about 400) Drain hose (Connecting part I.D. Ø14 O.D. Ø18 The hose length of outside the unit is approx. 465) INFRARED REMOTE CONTROL (ARC452A3) Right/left (automatic) Wall hole for embedded piping Ø65 hole STANDARD LOCATIONS OF WALL HOLES Wall hole Ø65 hole 3D058920A 6 Split Sky Air Indoor Units

Indoor Units R-410A FTXS-G 3 Dimensional drawing & centre of gravity 3-1 Dimensional drawing FTXS60GV The mark shows piping direction Air flow (indoor) (For performance and maintenance) Left Rear Rear Right (Including installation plate) Min. 30 (Space for performance) Model name plate Terminal block with earth terminal (inside) Min. 50 (Space for maintenance) REQUIRED SPACE Min. 50 (Space for maintenance) Bottom Signal transmitter Front grille fixing screws (inside) Flaps Signal receiver Model name plate BLADE ANGLES Intelligent eye sensor Operation lamp Timer lamp Intelligent eye lamp Indoor unit on/off switch Room temp. thermistor (inside) Horizontal blade (automatic) Dry Gas pipe ø12.7 CuT (the length of pipe outside the unit: about 430) Liquid pipe ø6.4 CuT (the length of pipe outside the unit: about 480) Drain hose for VP13 (connecting part I.D. 14.0, O.D. 18.0) (The hose length of outside the unit: about 530) Infrared remote control (ARC452A3) Fan Vertical blade (automatic) Wall hole for embedded piping ø 80 hole STANDARD LOCATIONS OF WALL HOLES Wall hole ø 80 hole 3D065514 FTXS71GV The mark shows piping direction Air flow (indoor) (For performance and maintenance) Left Rear Rear Right (Including installation plate) Min. 30 (Space for performance) Model name plate Terminal block with earth terminal (inside) Min. 50 (Space for maintenance) REQUIRED SPACE Min. 50 (Space for maintenance) Bottom Signal transmitter Front grille fixing screws (inside) Flaps Signal receiver Model name plate BLADE ANGLES Intelligent eye sensor Operation lamp Timer lamp Intelligent eye lamp Indoor unit on/off switch Room temp. thermistor (inside) Horizontal blade (automatic) Dry Gas pipe ø15.9 CuT (the length of pipe outside the unit: about 430) Liquid pipe ø6.4 CuT (the length of pipe outside the unit: about 480) Drain hose for VP13 (connecting part I.D. 14.0, O.D. 18.0) (The hose length of outside the unit: about 530) Infrared remote control (ARC452A3) Fan Vertical blade (automatic) Wall hole for embedded piping ø 80 hole STANDARD LOCATIONS OF WALL HOLES Wall hole ø 80 hole 3D065515 Split Sky Air Indoor Units 7

Indoor Units R-410A FTXS-G 3 Dimensional drawing & centre of gravity 3-2 Centre of gravity FTXS20-50G 4D059112B FTXS60-71GV 4D065274 8 Split Sky Air Indoor Units

4 Piping diagram Indoor Units R-410A FTXS-G FTXS20-42G INDOOR UNIT 6.4CuT Heat exchanger Field piping 6.4CuT Cross flow fan Thermistor on heat exch. Field piping 9.5CuT 9.5CuT Fan motor Refrigerant flow 4D058897C FTXS50G INDOOR UNIT 6.4CuT Heat exchanger Field piping 6.4CuT Cross flow fan Thermistor on heat exch. Field piping 12.7CuT 9.5CuT Fan motor Refrigerant flow 4D058898C Split Sky Air Indoor Units 9

4 Piping diagram Indoor Units R-410A FTXS-G FTXS60GV Indoor unit (7.9 CuT) Heat exchanger Thermistor on heat exch. Field piping Cross flow fan (6.4 CuT) Field piping (12.7 CuT) Fan motor (12.7 CuT) Refrigerant flow 4D040081V FTXS71GV Indoor unit (7.9 CuT) Heat exchanger Thermistor on heat exch. Field piping Cross flow fan (6.4 CuT) Field piping (15.9 CuT) Fan motor (12.7 CuT) Refrigerant flow 4D040082T 10 Split Sky Air Indoor Units

5 Wiring diagram 5-1 Wiring diagram FTXS20-50G Indoor Units R-410A FTXS-G WIRING DIAGRAM FIELD WIRING RECTIFIER OUTDOOR TRANSMISSION CIRCUIT CAUTION Note that operation will restart automatically if the main power supply is turned off and than back on again. INTELLIGENT EYE SENSOR INFRARED REMOTE CONTROL SIGNAL RECEIVER INDOOR FG F1U H1P~H3P M1F M1S~M3S PCB1~PCB4 R1T, R2T S1~S49 S1W X1M : Frame ground : Fuse : Pilot lamp : Fan motor : Swing motor : Printed circuit board : Thermistor : Connector : Operation switch : Terminal switch : Protective earth 3D058246B FTXS60-71GV Field wiring LED1 H1P LED2 H2P LED3 H3P Transmission circuit Outdoor CAUTION Note that operation will restart automatically if the main power supply is turned off and then back on again. Intelligent eye sensor infrared remote control Signal receiver Indoor FG Frame ground R1T,R2T Thermistor F1U Fuse S1~S49 Connector H1P~H3P Pilot lamp SW1 Operation switch M1F Fan motor X1M Terminal strip M1S, M2S Swing motor Protective earth PCB1~PCB4 Printed circuit board 3D064800 Split Sky Air Indoor Units 11

6 Sound data Indoor Units R-410A FTXS-G 6-1 Sound pressure spectrum FTXS20G COOLING FTXS20G HEATING 3D059555 3D059555 4 Operation differs with operation and ambient conditions. 4 Operation differs with operation and ambient conditions. FTXS25G COOLING FTXS25G HEATING 3D059556B 3D059556B 4 Operation differs with operation and ambient conditions. 4 Operation differs with operation and ambient conditions. 12 Split Sky Air Indoor Units

6 Sound data Indoor Units R-410A FTXS-G 6-1 Sound pressure spectrum FTXS35G COOLING FTXS35G HEATING 3D059557C 3D059557C 4 Operation differs with operation and ambient conditions. 4 Operation differs with operation and ambient conditions. FTXS42G COOLING FTXS42G HEATING 3D059558B 3D059558B 4 Operation differs with operation and ambient conditions. 4 Operation differs with operation and ambient conditions. Split Sky Air Indoor Units 13

6 Sound data Indoor Units R-410A FTXS-G 6-1 Sound pressure spectrum FTXS50G COOLING FTXS50G HEATING 3D059559B 3D059559B 4 Operation differs with operation and ambient conditions. 4 Operation differs with operation and ambient conditions. FTXS60GV Octave band sound pressure level db (0 db = 0.0002μ bar) Octave band sound pressure level db (0 db = 0.0002μ bar) Octave band center frequency - IEC (Hz) Octave band center frequency - IEC (Hz) Scale 1 Over All (db): (B,G,N is already rectified) 2 Measuring place: measure in anechoic room. 3 Operation differs with operation and ambient conditions. 4 Location of microphone. JISC9612 The operation measuring method is in accordance with JISC9612 50Hz 220-240V (H) (L) A 45 36 Scale 1 Over All (db): (B,G,N is already rectified) 2 Measuring place: measure in anechoic room. 3 Operation differs with operation and ambient conditions. 4 Location of microphone. JISC9612 The operation measuring method is in accordance with JISC9612 50Hz 220-240V H L A 44 35 3D051227D 14 Split Sky Air Indoor Units

6 Sound data Indoor Units R-410A FTXS-G 6-1 Sound pressure spectrum FTXS71GV Octave band sound pressure level db (0 db = 0.0002μ bar) Octave band sound pressure level db (0 db = 0.0002μ bar) Octave band center frequency - IEC (Hz) Octave band center frequency - IEC (Hz) Scale 1 Over All (db): (B,G,N is already rectified) 2 Measuring place: measure in anechoic room. 3 Operation differs with operation and ambient conditions. 4 Location of microphone. JISC9612 The operation measuring method is in accordance with JISC9612 50Hz 220-240V (H) (L) A 46 37 Scale 1 Over All (db): (B,G,N is already rectified) 2 Measuring place: measure in anechoic room. 3 Operation differs with operation and ambient conditions. 4 Location of microphone. JISC9612 The operation measuring method is in accordance with JISC9612 50Hz 220-240V (H) (L) A 46 37 3D051225D Split Sky Air Indoor Units 15

Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste. Daikin Europe N.V. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products. The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.. Daikin products are distributed by: Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende EEDEN10-100 CD 05/10 Copyright Daikin Prepared in Belgium by Lannoo (www.lannooprint.be), a company whose concern for the environment is set in the EMAS and ISO 14001 systems. Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende