Installation, Operation and Maintenance Instructions Document Ref:

Similar documents
Installation, Operation and Maintenance Instructions Document Ref:

Installation, Operation & Maintenance Instructions Document Ref:

Panther Fan Coil Units

WIRING DIAGRAMS AND OTHER RELAVENT LITERATURE WITH THE END USER. access panel Fan speed and on/off switches. Discharge spigot. Fan/motor.

Ocelot Fan Coil Units

Installation, Operation & Maintenance Instructions Document Ref:

Panther Fan Coil Unit

Efficient Cooling and Heating. Flexibility Is The Key

(UK) Date : February 2016 NOTE: PLEASE LEAVE COPIES OF THESE INSTRUCTIONS AND ANY DRAWINGS WITH THE END USER.

INTRODUCTION Flexibility Is The Key Simple Access For Maintenance

SERIES BM. Concealed Fan Convector

Series CM. Cased fan convector Sill-Line 600mm high 7 sizes and 3 heating coil options 1-13kW output with LPHW C heating medium

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user

S E R I E S B M C O M F O R T, A V A N T - G A R D E & L S T F A N C O N V E C T O R S

H Y D R O C O U R S E T R E N C H H E A T I N G

XB-EFA-8L-BK & XB-EFA-8R-BK

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

Installation, operation and Maintenance Manual

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

Halton CHB Active chilled beam with boost function for bulkhead installation

Aegean Range. A new range of fan coils for heating and cooling commercial applications

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

FAN COIL UNITS IMPORTANT NOTE ABOUT EC FAN SPEED CONTROL

AP-EH500-L/RQA9837. Installation Guide

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

SURFACE WARM CEILING HEATERS

Actionair Hydropac Waterside Control Fan Coil Units For Horizontal and Vertical Applications

ECOSMART TWINFANS. (EST-X/R/B) 1 phase, Direct Drive, Run & Standby For External, Roof Mounted and Internal use Installation and Maintenance

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

ECOSMART XTRACTOR. (ESX-X/R/B) 1 phase, Direct Drive For External, Roof Mounted and Internal use Installation and Maintenance.

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

Halton Rex 600 Basic R6B - Active chilled beam

Lo-Carbon Quadra Centrifugal Fan

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

TEMSPEC INC. VERTICAL FAN COIL UNIT MODELS TVA, TVE, TVS

Lo-Carbon Quadra SELV

INDOOR USE ONLY. Installation and Maintenance XTRACTOR. (ESX) 1 and 3 phase, Direct Drive, Fans for indoor use

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

This appliance has been CE-marked on the basis of compliance with the Low Voltage and EMC Directives for the voltages stated on the data plate.

Quantum Waterside Fan Coil Specification 2. Mounting 3. Pipework Connections 3. Duct Connections 3. Electrical Connections 4.

Operation & Maintenance Manual

Optimax Refrigerated Retail Merchandisers

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

AQUAIR S SERIES. of Water to Air Space Heaters INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONSS. Aquair S-10 Aquair S-16 Aquair S-20

Antarctic-Unit Cooler/Air Cooler

SPECIFICATIONS CWC - 2P / 4P CWC 020 CWC 030 CWC 040 CWC 050 CWC 070 CWC

TOSHIBA AIR CONDITIONING

Optimax Refrigerated Retail Merchandisers

Centrif Duo & Centrif Duo Plus

installation, operation & Maintenance manual acb ceiling-mounted cassette models

RECESSED WARM CEILING HEATERS MODELS HSRCH3000RF, HSRCH4500RF INSTALLATION AND OPERATING MANUAL

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

DOMINATORPLUS ELECTRIC RANGE APPLIANCES INSTALLATION and SERVICING INSTRUCTIONS

Quantum Airside Fan Coil Specification 2. Mounting 3. Pipework Connections 3. Duct Connections 3. Electrical Connections 4.

WHHR Midi & Midi Lite

MEV-DC. Continuous Mechanical Extract Ventilation Units Installation and Maintenance. Figure 3. Fixing screw hole.

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Vertical Stack Fan Coil Units Models: TVA, TVE, TVS

Units for suspended ceilings

Purge Ventilation Unit. Product Manual. ventilation systems TP625

SERVICING AND BREAKDOWN...

WXC R134a. Nominal Cooling Capacity from 224 to 692kW

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

Warnings, Safety Information and Guidance

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Ceiling Concealed Fan-Coil Unit

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

ELECTRIC WATER BOILER

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Caice Attenuator Selector - Specifier Edition

Installation and Maintenance

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL

PANEL HEATER OPERATING INSTRUCTIONS. For Models: TWFP10000, TWFP PK

Surface Warm Ceiling Heaters

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

2

Installation and Maintenance

Caice Attenuator Selector - Specifier Edition

Instruction Manual WARNINGS

Lo-Carbon T-series Window & Roof Models

Halton Rex for Vario R6O - Variable air volume chilled beam

Installation and Maintenance

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

T-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

TopVent Design Handbook

HOTLINE:

Passive chilled beams

Installation and Operating Manual Drying Cabinet

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Transcription:

Panther Fan Coil Units Installation, Operation and Maintenance Instructions Document Ref: Dunham-Bush Ltd, Downley Road, Havant, Hants PO9 2JD 023 9247 7700 info@dunham-bush.co.uk 126-000-001-C UK:www.dunham-bush.co.uk Global:www.dunham-bush.com October 2015 NOTE: PLEASE LEAVE COPIES OF THESE INSTRUCTIONS AND ANY WIRING DIAGRAMS AND OTHER RELAVENT LITERATURE WITH THE END USER. INTRODUCTION This booklet provides guidance to identify, handle, install and commission Dunham-Bush Panther fan coil units as well as guidance for operation and maintenance. These instructions are to be read in conjunction with the wiring diagram supplied with the unit. The instructions apply to units from the standard range only. Please study the instructions carefully before commencing any installation work. IDENTIFICATION The fan coil unit serial number, description, figure number (size) are displayed on a label found on the unit discharge plenum. If specified, a stencil reference may also be marked on the discharge plenum for on-site identification. DESCRIPTION Dunham-Bush Panther fan coil unit comprises a selffinished galvanised sheet steel casing with multiple access panels to each part of the fan coil unit, including fans, motors, air filter, dual purpose heating/cooling coil, electrical connections box and discharge plenum. STANDARD RANGE MODELS & SIZES Panther is a horizontal basic chassis fan coil, available in seven sizes, figs 1 to 7 inclusive Each size is available with octagonal or rectangular discharge plenums, as well as optional inlet spigot plenums. Panthers are available with AC motors or EC motors. Electrical connections and controls box Discharge spigots Valves and actuators (coil connections) Drip tray drain connection Filter access panel Fan/motor access Coil/drip tray access panel panel Diagram 1: Panther Fig 3 LH connections with octagonal discharge plenum Discharge plenum access panel

Diagram 2: Range of standard sizes with octagonal discharge plenum; rectangular discharge plenums are also available with similar sizes and dimensions. ACCESSORIES Standard controls Dunham-Bush Panther fan coil units are available with accessories for fitted stand alone or remote control. These include fitted or remote setpoint adjusters, remote room air sensors and remote fan speed controllers. Refer to the wiring diagram included with the fan coil unit for details on installation and wiring of remote controls. Discharge Configuration The standard configuration is for an octagonal discharge plenum with up to eight spigots (depending on size/figure number). Spigots up to Ø250mm diameter can be fitted, and can be removed and repositioned to suit duct connections on site. Spigots that are not required have an acoustically lined blanking plate fixed with selftapping screws. CONSTRUCTION Delivery The purchaser is responsible for off-loading, and must examine the fan coil units promptly upon receipt. Any claims for damage will only be accepted if, at the time of delivery, the consignment note is endorsed with the details and counter- signed by the transport driver. Each fan coil unit is marked to show the model, figure number, serial number and stencil reference if specified. Handling and Storage Fan coil units are individually packed and two/three persons can usually handle the heaviest unit. When a significant quantity of fan coils is delivered, they may be palletised and shrink-wrapped, so a fork-lift or similar will be required for lifting. The fan coil unit must not be dropped or suffer impact in any circumstances and should never be lifted or handled by their coil connections. Fan coil units should be stored in clean, dry conditions. Any packaging should not be removed until the fan coil unit is required for installation. Packaging should only be removed if damage is suspected at the time of delivery. Page 2 of 12

WARNING: Panther fan coil units are designed with minimal sharp edges on the chassis. Some internal components on the fan coil may have sharp edges. Care must be taken when handling the product; protective gloves should be worn. FIGURE 1 2 3 4 5 6 7 Dry mass of basic unit with discharge spigot plenum only (kg) 37 51 56 70 75 92 96 Table 1: Approximate masses of Panther fan coil units INSTALLATION General Before removing any packaging, check the identity of the fan coil unit against the stencil reference marked on the access panel. Packaging should be retained to protect the fan coil unit from damage by other works after installation. Fitting 1. Prepare drop rods to accept the fan coil. M6, M8 or M10 drop rods are recommended, with appropriate washers. Refer to diagram 2 for positions of fixings. 2. Suspend the fan coil unit and ensure it is level in both directions. Use a spirit level on the casing. (The drip tray is graded internally to ensure drainage of condensate). 3. Connect ductwork to the fan coil unit. Flexible duct connections are recommended where sheet metal ductwork is used. Do not suspend any ductwork from the fan coil unit alone. Refer to diagram 3 for spigot positions. 4. Connect pipework as shown in Diagram 4. 5. Connect a suitable drain to the drip tray. 6. Connect electrical supply and control accessories as shown in wiring diagrams enclosed with the fan coil unit. 7. After filling the hot and chilled water systems, check for leaks (refer to Commissioning). 8. Ensure the condensate pump (if fitted) is installed in accordance with the manufacturer s requirements. Pipework Connections 1. The coil is a dual purpose coil with OD15mm copper tube tails at 40mm centres between flow and return connections. Always observe the correct direction of flow. (see Diagram 4) 2. Local isolating and regulating valves are recommended, as well as strainers to filter out foreign matter in the water. 3. The installer must provide any fittings to connect pipework to fitted 2 or 4 port valves. 4. The standard drip tray has an OD22mm tube connection, suitable for a compression fitting or similar, to be supplied by the installer. A 15mm option is also available at order stage. Electrical connections and controls 1. The electrical connections box is located on the side of the fan coil unit, and incorporates a hinged access door, fastened with a self-tapping screw. 2. Connect a 230V/1ph/50Hz supply to the flying lead fitted to the electrical connections box. 3. Fit any remote accessories in their appropriate locations and connect terminal block inside the electrical connections box. Refer to the wiring diagram enclosed with the fan coil unit for specific wiring details. 4. All wiring should comply with IEE regulations (BS 7671) and local bye-laws. Page 3 of 12

Diagram 3: Standard spigot sizes and positions; rectangular discharge plenum is similar. Diagram 4: Pipework connections, as viewed on header/connection end of coil Page 4 of 12

Diagram 5: Inlet filter Diagram 6: Fan access panel COMMISSIONING 1. Ensure that the fan coil unit is clean, and the filter especially is clean and free from dust. Check the fastness of all access panels and ductwork connections. 2. Check that all electrical connections are correct and comply with BS7671 and local bye-laws. Refer to the wiring diagram supplied with the fan coil unit 3. Check the coil connections and drip tray connections for leaks. Refer to Table 3 for coil test and working pressures. 4. Purge air from both heating and cooling sections of the coil using the manual air vents fitted. 5. Balance the water flow rate through both hot and chilled water systems following accepted practice to achieve the specified flow rates. 6. On AC motor units, there are two fan speed switches - one to give three main speeds, and the other to provide a fine-adjust to each speed. Set the switches to the specified design settings, as highlighted on the label fixed the plenum access panel. On EC motor units, adjust potentiometer to ensure air volume to design specification. If using a BMS controller with a 0-10V output, adjust the fan via the remote interface to ensure air volume and external static resistance are both to design specification. 7. If fitted, set any remote switches and/or controls to the specified settings. 8. Check the operation of controls in accordance with control manufacturer s instructions. 9. Check the operation of any remote fan speed or remote thermal controls. 10. If supplied/fitted, check the operation of the condensate pump by pouring a small quantity of water into the drip tray; ensure the pump clears any water and operates any alarms etc. 11. Leave this document and the wiring diagrams with the end user. For further information on any fan coil unit - contact Dunham-Bush, quoting the serial number on the label on the access panel. Page 5 of 12

Size Cooling coil valve Kv Heating coil valve Kv Figure 1 1.0 0.6 Figure 2 & 3 1.6 0.6 Figure 4 & 5 1.6 1.0 Figure 6 & 7 1.6 1.0 Table 2: 4 port valves; recommended Kv values to match coils Coil Section Maximum test pressure Recommended working pressure Cooling 20 bar gauge 7 bar gauge Heating 20 bar gauge 7 bar gauge Table 3: Maximum test and working pressures WARNING Air vents should not be operated during pressure tests. Recommended working pressure is limited to 7 bar gauge to ensure safe operation of manual air vents. Size Cooling section content (l) Heating section content (l) Figure 1 1.70 0.20 Figure 2 & 3 2.55 0.28 Figure 4 & 5 3.68 0.40 Figure 6 & 7 4.53 0.51 Table 4: Water content of cooling and heating sections of coil OPERATION Panther fan coils provide cooling and heating of air when used in conjunction with chilled water and/or low temperature hot water systems. They are designed for mounting in a ceiling or roof void, connected to ductwork. When running, the fan draws air from the room and the primary air supply, through an inlet filter and over the finned tubes of a heating/cooling coil. The air is then discharged through spigots, along ductwork and through grilles or diffusers to the room space. Alternative options include chilled water cooling only, and intake through ductwork and spigots. Fans normally run continuously, with an automatic control system varying the flow rates of chilled water and hot water through the coil (waterside control), thus varying the cooling and heating outputs. Depending upon the particular type of controls fitted, user control is provided by fan speed switches and/or temperature control. CONTROLS Panther fan coil units are fitted with a waterside control system, which typically comprises the following elements :- Fitted fan on/off switch Fan speed change switches (AC motor units) Fan speed potentiometer (EC motor units) Fan coil controller Return air sensor Valve actuators (Two or four port valves) Additional optional accessories include :- Remote room air sensor Remote setpoint adjuster Remote fan on/off and speed switches Fitted relays for master/slave or BMS control Dunham-Bush also fit non-standard controls supplied by others; refer to the wiring diagram supplied with the unit. Page 6 of 12

MAINTENANCE 1 Prior to undertaking any cleaning or maintenance, ensure that the fan coil unit and any controls are disconnected from the electrical supply at the local isolator. 2 Some internal components may have sharp edges. Care must be taken when working on the fan coil unit, and protective gloves should be worn Cleaning and maintenance must be carried out by competent persons Inspection The frequency of cleaning and inspection depends upon the conditions in which the fan coil unit operates. Initially, it is suggested that the air filter and drip tray are inspected after 6-8 weeks of normal operation. Access There are four access panels - filter, drip tray/coil, fans/motors and discharge plenum. All access panels can be opened by removing screws and turning quarter-turn fasteners. Cleaning Panther fan coil units are fitted with an air filter on the inlet. The filter comprises a filter frame, mesh and filter material that is retained with wire clips into the filter frame. The filter can be removed by either sliding the filter sideways, out of its channels on the unit chassis or by pushing and tilting the filter out of the channels, as shown in diagrams 7 to 10 below. 1. Air filters can be cleaned by tapping out excess dust and washing in warm water (up to 40 C), using detergent if necessary. 2. The filter must be rinsed and allow to dry naturally before replacing. Do not use a vacuum cleaner, as it can damage the filter media. Filters should be replaced after approximately 20 washes. 3. The drip tray can be cleaned with warm, soapy water. Ensure the drip tray drains freely. 4. If a condensate pump is fitted, check any sensors are clean and wiped dry. Test the operation of the pump by pouring clean water into the drip tray. Because the air filter retains most of the dusty particles, it will only be necessary to clean the fans, motors and coil annually. An industrial vacuum cleaner can be used to clean the inside of the fan coil, in particular the coil and fans, with the air being sucked through the coil in the opposite direction to normal air flow. All accessible surfaces can be cleaned with a cloth. Diagram 7: Hold the filter frame. Diagram 9: Push up and tilt the filter outwards Diagram 8: Slide the filter by a few inches. Diagram 10: Withdraw the filter Page 7 of 12

MAINTENANCE 1. Purge any air from both cooling and heating sections of the coil using the manual air vents (using a suitable key). 2. The fan motor has sealed for life bearings which do not require any maintenance, other than visual inspection 3. The electrical connections box incorporates a 5A fuse. 4. Each fan coil unit is supplied with a wiring diagram applicable for the particular controls and accessories (Refer to pages 7 and 8). Further copies are available on request. Please quote the serial number on the label on the main access panel. 5. Check the operation of all controls by varying their settings to achieve the desired effect on the fan. Page 8 of 12

INSTALLING AN INLET ATTENUATOR Panther fan coil units are available with optional accoustic attenuators, factory to inlet or discharge. They can also be fitted on site to reduce noise levels from the fan coil unit inlet, as shown below. Diagram 11: Remove inlet filter; drill out rivets from first line of holes behind filter. Offer up attenuator to the fan coil unit inlet (with air filter removed) Diagram 12: Assemble filter to fan coil unit inlet, using fixing screws provided through top of attenuator into the fan coil unit casing. Diagram 13: Suspend attenuator with drop rods though suspension slots; adjust suspension to mate attenuator to unit inlet. Refit air filter to attenuator inlet. Page 9 of 12

Page left blank intentionally Page 10 of 12

Page 11 of 12

SPARES/SERVICE PLEASE WRITE THE DETAILS OF THE UNIT HERE. These details will be required when ordering spares for you Dunham-Bush Panther Fancoil Unit UNIT TYPE AND MODEL INFORMATION SERIAL NUMBER DATE OF INSTALLATION Spare parts/service Please contact our office, contact information shown below. Manufacturer reserves the right to change any product specification without notice. Dunham-Bush Ltd Downley Road Havant Hants, PO9 2JD Sales & Applications Spare Parts and Service Tel: 023 9247 7700 Fax: 023 9245 3601 Tel: 023 9247 7700 Fax: 023 9245 3601 Email: infouk@dunham-bush.co.uk Email: spares@dunham-bush.co.uk Page 12 of 12