Design Evolution: From Rolling Piston to Revolving Vane to Cross-Vane Expandercompressor

Similar documents
Twenty Years of Compressor Innovation at NTU, Singapore

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

Analysis of Oil Pumping in the Hermetic Reciprocating Compressor for Household Refrigerators

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

Experimental performance evaluation of heat pump by using CO 2. as a refrigerant. IOP Conference Series: Materials Science and Engineering

Enhancing the performance of the domestic refrigerator with hot gas injection to suction line

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

Capillary Tube and Thermostatic Expansion Valve Comparative Analysis in Water Chiller Air Conditioning

Study on a novel variable capacity technology and control strategy for refrigerated shipping container unit

Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

HVAC Water chiller selection and optimisation of operation

Effects of seawater flow rate and evaporation temperature on performance of Sherbet type ice making machine

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

Torad Rotary Spool Compressor

Evaluation of moisture content in drying of grated coconut meat using grain moisture meter

Rotodynamic Pumps INTRODUCTION:

Performance Study of Solar Heat Pipe with Different Working Fluids and Fill Ratios

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Compressor Capacity Control: A New Direction

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

High-efficiency Turbo Chiller (NART Series)

Purdue e-pubs. Purdue University

Performance Characteristics of a Refrigerator- Freezer with Parallel Evaporators using a Linear Compressor

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

Development Of 2-Cylinder Rotary Compressor Series For Light Commercial Use With R410A

Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Comparison Of Hermetic Scroll And Reciprocating Compressors Operating Under Varying Refrigerant Charge And Load

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Effect on air quality and flow rate of fresh water production in humidification and dehumidification system

SRC: Smart Reminder Clock

Design, Manufacturing of Chilled Water System for Process Cooling Application

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Main Characteristics of Appliances for Transport and Compression of Air

Performance investigation of Air-conditioning system using ejector as expansion device

How to Cut Chiller Energy Costs by 30%

To investigate the surface properties for increasing efficiency of solar water heater

Thermal Modelling for the Motor in Semi-hermetic Screw Refrigeration Compressor under Part-load Conditions

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

Spool Compressor Technology Introduction

Refrigeration & Air Conditioning Experiment No. 5. Experiment No. 5

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

Adsorption refrigeration system using waste heat

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Ultraviolet radiation detector to obtain the rate of particles at different heights

Properties of a two stage adiabatic demagnetization refrigerator

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

UNIT 4: REFRIGERATION PRINCIPLE

Assuring Reliability of Compressors Using HFC Refrigerants By Hideto NAKAO Mitsubishi Electric Corporation Amagasaki-City, Hyogo, Japan

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Diagnosing Troubles in Refrigeration Units with Screw Compressors

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

The Design Of A New Generation Of Twin Screw Refrigeration Compressors

The rotary type compressor consists of an integrally formed rotor and shaft, five vanes, and a cylinder.

Building Coverage Ratio at the Eastern Corridor of Jalan Ir. H. Djuanda Bandung

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Experimental study on performance of BOG compressor

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Chapter-8 Capacity Control of Refrigeration Systems

Experimental investigation of the dynamic thermohydraulic behaviour of vertical tube reboilers

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

A TRNSYS Simulation Case Study on Utilization of Heat Pump For both Heating and Cooling

Compression of Fins pipe and simple Heat pipe Using CFD

Compressor Durability Tests and System Tests with AB and HFCs

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

A study of Transient Performance of A Cascade Heat Pump System

Two-Step Capacity Modulation of a Single Cylinder Compressor

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

The pump. A pump is a device that moves fluids (liquids or gases), or sometimes slurries, by mechanical action.

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Study of building typology of school constructed during the Dutch Colonial Period in Indonesia. Case study of Hoogere Burgerschool (HBS) in Bandung

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Dynamic Simulation of Liquid Chillers

Evaluation of Slip Potentials on Bilecik Beige Marble with Pendulum Method

High Efficiency R-134a Compressor for Domestic Refrigerator

Chapter 4 Compressors Overview & System Annual Power Consumption

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Review of flow-through design in thermoacoustic refrigeration

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Experimental Comparison of Natural Convection Heat Transfer from a Blackened V-Fin Array

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

PREVIEW COPY. Compressors. Table of Contents. Introduction to Compressors...3. Lesson Two Reciprocating Compressors...21

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Savings and performance worth celebrating! The DHP-AQ new air source heat pump from Danfoss

Investigation of Separating Small Impurities and Heavy Compounds Using the Cotton Separator Equipment

Transcription:

IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Design Evolution: From Rolling Piston to Revolving Vane to Cross-Vane Expandercompressor unit Related content - Observation of Oil Flow Characteristics in Rolling Piston Rotary Compressor for Reducing Oil Circulation Rate S j Song, K Y Noh, B C Min et al. To cite this article: K T and Yap K S 2015 IOP Conf. Ser.: Mater. Sci. Eng. 90 012036 View the article online for updates and enhancements. This content was downloaded from IP address 148.251.232.83 on 04/07/2018 at 21:13

Design Evolution: From Rolling Piston to Revolving Vane to Cross-Vane Expander-compressor unit. Ooi K T 1 and Yap K S 2 1,2 Nanyang Technological University, 50, Nanyang Avenue, Singapore 639798 2 TUM CREATE (Technische Universität München - Campus for Research Excellence And Technological Enterprise), 1 CREATE Way, #10-02, CREATE Tower, Singapore 138602 1. Introduction Abstract In this paper the design evolution from rolling piston compressor (RP) to revolving vane compressor (RV) and finally to cross-vane expander-compressor unit (CVEC) is presented and discussed. The details in the design philosophy which initiated this evolution will be presented and discussed. It is estimated that more than 90% of the room air-conditioners uses RP in its compressor. This is because of its advantages: it has the few parts, it is simple geometrically and it is reliable. However, it is with no weaknesses. RP s weaknesses lie in three parts: too many rubbing surfaces with high relative rubbing velocity with each other which give rise to high frictional losses; components (eccentric and roller) are not rotating at their centres and resulted in unnecessary inherent vibration; vane tip is constantly rubbing against the roller making it a weakest part in design. To overcome RP s weaknesses, RV is introduced. As compared to RP, RV has fewer rubbing surfaces, and the relative velocities among these surfaces are reduced Components in RV rotate at their own centres and there is no inherent vibration; the rubbing at the vane tip has been eliminated completely. However, like RP, RV also has a large rotor which occupied useful space and making the working chamber relatively small. To overcome this latter problem, CVEC is introduced. In this newly invented CVCE, not only parts are all concentric and rotate at their own centres, the unit also recovers expansion energy and hence significantly reduces energy required by the refrigeration systems. And, more importantly, all these are carried out not at the expense of the additional cost. In this paper, details on these three compressors are explained, compared and their respective uniqueness are shown and discussed. Literature shows that significant research has been carried out to arrive at what we have today for a relatively energy efficient running refrigeration compressors. Among the most popular compressors in use today, there are rolling piston, reciprocating, scroll and screw. Rolling piston compressor (RP) is generally used for cooling capacity below 15 kw, though recently more and more RPs are used for cooling capacity of 15kW and above. In room air-conditioners applications, more than 90% of the Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by Ltd 1

compressor used RP. This is because of its simple geometry, few parts and relatively reliable. However, RP has some design weaknesses such as significant frictional losses due to a number of rubbing surfaces which have high relative rubbing velocity to each other; components (eccentric and roller) are not rotating at their centres and resulted in unnecessary inherent vibration; vane tip is constantly rubbing against the roller making it a weakest part in design. To overcome RP s weaknesses, revolving vane compressor (RV) is introduced. RV has fewer rubbing surfaces, and the relative velocities among these surfaces are reduced. Components in RV rotate at their own centres and hence no inherent vibration, and there is no vane tip contact. However, RP and RV have large rotors which occupied useful space. To overcome this, CVEC was introduced. In CVCE, not only parts are all concentric and rotate at their own centres, the unit also recovers expansion energy and hence significantly reduces energy required by the refrigeration systems. In this paper, details on these three compressors are explained, compared and their respective uniqueness are shown and discussed. 2. Rolling piston compressor Rolling piston compressor is one of the most widely used compressors in room air-conditioners. It is mostly used in the applications where the cooling capacity is lower than 15 kw. Figure 1 shows a schematic diagram of a rolling piston compressor. In its basic form, it consists of five components: A cylinder (call stator), a roller, an eccentric, a vane and a discharge valve. During operation, the roller rols in the cylinder but maintaining contact with the cylinder and the vane tip at all time, creatin two working chambers. These wrolking chambers are bounded by inner surface of the cylinder, out ter surface of the roller and the vane. While one chamber is expanding, hence suction proces, the other is compressing hence compression process. Once the gas pressure reachs that of the discharge pressure, the gas is discharged out f the working In this new designchamber through the discharge port. There are six areas of frictional losses [2]: 1. Eccentric and the inner surface of the roller, 2. Roller face and the cylinder head face, 3. Eccentric face and the cylinder head face, 4. Vane tip and roller, 5. Vane sides and vane slot, 6. Outer roller surface and the inner cylinder surface. For item (1) above, the rubbing between the inner surface of he roller and the eccentric is dependent on the forces acting on the roller and the viscous forces at the rubbing surfaces. For the items (2) to (6) the rubbing is between moving surfaces against staionary surfaces, hence the relative velocity reponssible for the friction is relatively large. Attention must also be paid to the rubbing at the vane tip and the roller. This latter rubbing region is a critical rubbing part, this is because a small region of the vane tip rubs against a relatively large outer surface of the roller, cuasing vane tip to wear easily, and in practice, the vane and the roller are harden to reduce wear. 2

It is noted that also, the main driving comoponent for the RP is the ecnetric. The motion of ecentric drives the roller and hence froming the comrepssion and the scution chambers mentioned earlier. This ecccentric inhenrently introduce wobbling motion which induces vibration. (b) R c R r R v R s ω ω r cylinder radius (m) roller outer radius (m) radius of vane tip (m) shaft radius (m) angular velocity of crankshaft (rad/s) angular velocity of roller (rad/s) Figure 1 (a) Schematic of a rolling pisont compressor [1], (b) Discharge valve [2] 3 Revolving vane compressor RV compressor [3,4] is introduced to mitigate the disadvatges inherently in the RP. Figure 2 shows the schematics of the RV. In its basic form, RV compressor has 4 parts: a cylinder, a rotor, a vane and a discharge valve (no shown). Figure 3 shows the snapshots of the opration of the RV. One of the distinguishing feature of the RV is that during the operation, the cylinder rotates together with the rotor. The rotating cylidner rotates the two end faces of the cylinder as well, hence making all the rubbing surfaces have lower relative velocity and hence reduces the fricitonal loss significantly. Refer to the six itms of frictional areas mentioned in section 2 for RP, in the design for RV, there is no eccentric, the frictional losses caused by items (1) and (3) are no longer presence. Since the cylinder is also rotating, items (2) and (6) in section 2, have significantly lower frcition. Vane tip in RV design is longer rubbng against any surface and hence item (4) is totally eliminated. Item (5) in section 2, has a 3

very significant improvement. Since the vane is now rigid secured on to the cylinder, the vane slot which rubs agains the vane surfaces is now located at the rotor. It is this arrangement that predominantly caused the vane side frcition to be completely independet from the pressure differential across the vane! This has a huge significance especially when the compressor is operating under a high pressure difference condpition between the suction and the discharge, such as those when using CO2 as the refrigerant. Thus, fricitonal loss caused by item (5) has hugh implication in performnce improvement in the case for RV when compared to RP. The fricitonal loss caused by item (5) for Rv is only dependent on the rotating inertia of the rotor. Figure 2 Schematics [3] and 3-D mark-up of the fixed-vane revolving vane compressor. Figure 3 Snapshots of revolving vane comrpessor operation [4] 4

The revolving vane comrpessor can be dsigned with swiveling vane or fixed vane and the vane can be fixed either on the cylinder or on the rotor. Figure 5 shows the inertia torque variations for these different designs. It is advisable to fix the vane on the driving component, i.e. if the vane is fixed on the cylinder, the cylinder should be the driving component and vice-versa. The revolving vane comrpessor can be dsigned with swiveling vane or fixed vane and the vane can be fixed either on the cylinder or on the rotor. Figure 5 shows the inertia torque variations for these different designs. It is advisable to fix the vane on the driving component, i.e. if the vane is fixed on the cylinder, the cylinder should be the driving component and vice-versa. Figure 4 the cylinder assemby cmponents of revolving vane compressor [5]. Figure 5 Variations of the inertia torque over three different revolving vane compressor designs [3] 5

4 Cross vane compressor-expander unit Referring to RP and RV in figures 1(a) and 2 respectively, it can be seen that the available working spaces (working chamber) of the two compressors are relatively small as compared to the overall size of the compressor. This is because the useful space has been occupied by a relatively large rotor. It can be seen from the two figures that the rotors for both design are relatively large as compared to the cylinder, and the working chamber is comparatively small. The next question is that will we be able to make use of the space occupied by the rotor and makes the comrpessor or the refrigeration cycle works better. This thought has lead to the born of the cross-vane comrpessor expander unit (CVEC) [6,7]. Figure 6 shows the sschematics of the CVEC. It can be seen immediately that the rotor is no longer a solid cylinder but a hollow cylinder. In fact the space created by this hollow rotor is actuall an expander! Figure 6 schematics of the cross-vane expander compressor unit. During operation, the rotation of the shaft causes the vane to rotate which in turn rotates the cylinder for compressor and the expander. Figure 7 illustrates the snapshots of the operation of CVEC. The motion causes the volumes trapped within the suction and compression chamber of the compressor to vary, resulting in suction, compression and discharge of the working fluid. Similarly, the volumes trapped within the suction and discharge chamber of the expander varies too, resulting in suction, expansion, and discharge of the working fluid. Both the compressor and expander operate concurrently. Such a machine is best to work with working fluids which operates on large pressures between suction and discharge of the compressor, such as CO 2. This large pressure difference will result in a significant power being recovered, which, otherwise wasted at the expansion valve, and hence increases significantly the overall COP of the CO2 cycle. Theoretical analysis (not shown) shows that 14-40% COP increase is possible. Figure 8 shows schematics of a refrigeration cycle fitted with CVEC. It is noted that the expansion valve and the compressor is now replaced by CVEC. 6

Figure 7 Operation snapshots of cross-vane expander comrpessor Figure 8 Schematics of a refrigeration cycle fitted with CVEC To understand the behaviour of the CVEC in a greater detail, the components of the instantaneous power of the machine is shown in Figure 9 and these are: compression power, expansion power, inertial power, and total frictional power loss. The phase difference has resulted in the decrease of CVEC peak power of about 4.3%. This improvement is still relatively small, and ideally, the peak power of the compressor and expander should be matched at the same instance. This not only reduces the peak power of the CVEC further, but also ensures that all the recovered power from the expansion process is fully utilized throughout the cycle. All in all, the average power of the compressor, expander, inertial effect, and total frictional loss are calculated to be 1181.6W, 213.2W, 0W, and 31.3W respectively. The average expansion power is 18.0% of the compression power, and when it is utilized to partially drive the compressor, an improvement of 21.3% in the COP of the refrigeration cycle could be achieved. In addition, the average total frictional loss is comparatively small too, and as a result, a mechanical efficiency of the CVEC of 96.9% could be obtained. 7

5. Conclusion Figure 9 Instantaneous power constituents of cross-vane expander comrpessor Rotary compressor has recorded an annual sale of more than 150 million units in 2013 [8]. With constant design improvement of the compessor, the energy efficiency of the refriegration cycles can be improved. This improvement will bring about significant energy and materials asving. In this paper, CVEC is useful not only it reduces the mechanical power loss but it also recoves expansion energy in the vapour compression refriegration cycle, which is otherwise lost, into useful eenrgy to supplement the power needed by the compressor. With its simple geometry and fewer parts, it is expected that there will not be any manufacturing cost increase when using this CVEC with the exisitng refrigeration cycle, but significant operational cost saving is expected. It is particularly true when it is employed in the CO2 refrigeration cycle. References [1] Ooi K T 2005 Design optimization of a rolling piston compressor for refrigerators Applied Thermal Engineering, Vol 25 Issues 5 6 pp 813 829 [2] Ooi K T and Wong TN, (1997), A computer simulation of a rotary compressor for house-hold refrigerators. Applied Thermal Engineering, 17(1) pp 65-78. [3] Tan K M and Ooi K T 2011 A novel revolving vane compressor with a fixed-vane. Int. J. Refrigeration 34(8) pp 1980-1988. [4] Tan K M and Ooi KT 2010 Journal bearings design for a novel revolving vane compressor, Int. J. Refrigeration, 34 (1), pp. 94 104 [5] Tan K M and Ooi K T 2014 Experimental study of fixed-vane revolving vane compressor. Applied Thermal Engineering 62(1) pp 207-214. [6] Yap K S and Ooi K T and Chakraborty A 2014 Introduction of the Novel Cross Vane Expander- Compressor Unit for Vapour Compression Cycle International Compressor Engineering Conference at Purdue p 1129 [7] Yap K S, Ooi K T and Chakraborty A 2014 Modelling and Simulation of the Dynamics of Cross Vane Expander-Compressor Unit for Vapour Compression Cycle, International Compressor Engineering Conference at Purdue, p 1134 [8] Cover story, JARN, September 2013, Serial no 536, 45(9). 8