GENERAL NOTES 10955-2 G-2 FLORIDA P.E. 34942
1 A 1 DETAIL A SECTION SYMBOLS AND ABBREVIATIONS 10955-3 G-3 FLORIDA P.E. 34942
PROCESS SCHEMATIC PROCESS SCHEMATIC AND NOTES 10955-4 G-4 FLORIDA P.E. 34942
OVERALL SITE PLAN AND KEYMAP 10955-5 C-1 FLORIDA P.E. 34942
A 2 B 2 C PAVING GRADING AND DRAINAGE 10955-6 C-2 FLORIDA P.E. 34942
6 6 1 7 YARD PIPING PLAN 10955-7 C-3 FLORIDA P.E. 34942
PROFILE 'A' - 30" TANK INLET PROFILE 'B' - 30" TANK OUTLET YARD PIPING PROFILES 10955-8 C-4 FLORIDA P.E. 34942
3 2 3 1 DETAIL 2 DETAIL 3 4 DETAIL CIGAR CUT ALL SABLE PALM HEADS, REMOVE ALL EXISTING FRONDS AND CUT BACK THE BUD TO A MINIMUM OF 12". WASHINGTONIAN PALMS TO BE TRIMMED AND TIED FOR TRANSPORTING. TREES TO BE UNTIED IMMED- IATELY PRIOR TO INSTALLATION FINISHED GRADE 2 PAD 1" ABOVE FINISHED GRADE 3 CONCRETE PAD: 18"x18"x4" THICK, IN UNPAVED AREAS CLEAR TRUNK TRUNK SHALL BE FREE OF SCARS, BURN MARKS, AND BOOTS. 5 LAYERS OF BURLAP, 3-2"x4" WOOD CLEATS, CONNECTED WITH 2-3/4" STEEL BANDS 3-2"x4"WOOD BRACES AT 120 APART, LEANGTH AS REQUIRED AS REQUIRED ADJUSTABLE VALVE BOX GATE VALVE 1/3 HEIGHT OF CLEAR TRUNK MULCH 3" FROM TRUNK 3" MULCH LAYER 6" EARTHEN SAUCER 2"x4"x30" WOOD STAKE APPROVED SABLE PALM PLANTING SOIL BACKFILL FERTILIZER TABLETS AS REQUIRED. SEE NOTES 1 AND 2 BELOW 12" 12" UNDISTURBED SOIL H H NOTES: 1. FOR GENERAL REQUIREMENTS AND CONDITIONS, SEE CITY STANDARD DETAIL-GENERAL LANDSCAPING NOTES. 2. FOR FERTILIZING, WATERING, AND WARRANTY REQUIREMENTS, SEE STANDARD DETAIL-FERTILIZATION, WATERING, AND WARRANTY. 3. ALL SABLE PALM ROOT BALLS SHALL BE A MINIMUM OF 3'-0"x3'-0". 4. ALL SABLE PALMS SHALL BE STAKED AS SHOWN ABOVE. NOTES: 1. H = HARNESSED JOINT. (MECHANICAL JOINT W/ D.I. RETAINER GLAND). 2. ASSEMBLY AS SHOWN IS FOR A 4" AND LARGER GATE VALVE, TAPPING VALVE, BUTTERFLY VALVE, AND PLUG VALVE ARE SIMILAR. 3. 2" VALVE, JOINT ENDS SHALL BE THREADED. REVISIONS ENGINEERING and CAPITAL CITY of ST. PETERSBURG SCALE: N.T.S. PALM TREE PLANTING DETAIL DIRECTOR : DWG. No. MARCH 2006 S10-15 REVISIONS SWB 09/96 SWB 06/98 ENGINEERING and CAPITAL CITY of ST. PETERSBURG SWB 06/02 SWB 03/06 SCALE: N.T.S. VALVE AND VALVE BOX DETAIL DIRECTOR : DWG. No. MARCH 1993 S50-22 6 DETAIL 7 DETAIL CIVIL DETAILS 10955-9 C-5 FLORIDA P.E. 34942
4 A SECTION B SECTION 4 C SECTION CIVIL DETAILS 10955-10 C-6 FLORIDA P.E. 34942
1 2 ELEVATION 4 3 1 PLAN VIEW PROPOSED 15 MGAL REJECT TANK 10955-11 PLAN & ELEVATION M-1 FLORIDA P.E. 34942
6 3 DETAIL 2 DETAIL 1 DETAIL 5 DETAIL 4 DETAIL 6 DETAIL PROPOSED 15 MGAL REJECT TANK 10955-12 SECTIONS AND DETAILS M-2 FLORIDA P.E. 34942
1 PROPOSED 15 MGAL REJECT TANK 10955-13 DETAILS M-3 FLORIDA P.E. 34942
1 PROPOSED 15 MGAL REJECT TANK 10955-14 DETAILS M-4 FLORIDA P.E. 34942
Eng: BB ELECTRICAL ABBREVIATIONS 10955-15 AND LEGEND BAHMAN BEHZADI E-1 FLORIDA P.E. 53636
1 1 PLAN Eng: BB ELECTRICAL SITE PLAN 10955-16 BAHMAN BEHZADI E-2 FLORIDA P.E. 53636
1 A 1 2 A B A CONDUIT AND CABLE SCHEDULE 1 1 PLAN 1 Eng: BB ENLARGED ELECTRICAL SITE PLAN 10955-17 BAHMAN BEHZADI E-3 FLORIDA P.E. 53636
2 TYPICAL OPEN-CLOSE VALVE CONTROLLER CONNECTIONS 1 TYPICAL MOTOR ACTUATOR FOR BFV 3 TYPICAL POWER FEED TO MOV CONTROLLER CONNECTORS Eng: BB ELECTRICAL DETAILS 10955-18 BAHMAN BEHZADI E-4 FLORIDA P.E. 53636
Eng: BB ELECTRICAL DETAILS 10955-19 BAHMAN BEHZADI E-5 FLORIDA P.E. 53636
Eng: BB BAHMAN BEHZADI FLORIDA P.E. 53636 REVERE CONTROL SYSTEMS AS BUILT SP-500 CONTROL PANEL (1) 10955-20 E-6
Eng: BB BAHMAN BEHZADI FLORIDA P.E. 53636 REVERE CONTROL SYSTEMS AS BUILT SP-500 CONTROL PANEL (2) 10955-21 E-7
Eng: BB BAHMAN BEHZADI FLORIDA P.E. 53636 REVERE CONTROL SYSTEMS AS BUILT SP-500 CONTROL PANEL (3) 10955-22 E-8
Eng: BB BAHMAN BEHZADI FLORIDA P.E. 53636 REVERE CONTROL SYSTEMS AS BUILT SP-500 CONTROL PANEL (4) 10955-23 E-9