Technical data. Danfoss DHP-L

Similar documents
Technical Data. Danfoss DHP-C. Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-H. Extra and hotter hot water. Extra large integrated hot water tank. Can reduce heating costs by more than 50 percent.

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M.

Installation instructions Danfoss heat pump DHP-R

DHP-H Varius Pro+/DHP-L Varius Pro+

Installation instructions

Heat Pumps, Packaging and Document Kits

Technical description. Atec.

Technical data DHP-R. A brine-to-water building heat pump in power outputs

Planning guide. Atec.

USER MANUAL. Danfoss Heat Pump DHP-R VUIFK102

UK-specific appendix to Installation instructions DHP-A DHP-A Opti DHP-AQ Maxi DHP-H DHP-H Opti DHP-H Opti Pro DHP-L DHP-L Opti DHP-L Opti Pro

NIBE F1355. A +++ The system's efficiency class for heating. Speed-controlled ground source heat pump for large buildings. Ground source heat pump

Planning guide. (2010/09) en

Air/water - Heat pumps

User manual DHP-AQ VUGFB102

NIBE F2026 air/water heat pump. fresh air s free. NIBE F2026. Efficient scroll compressor that operates at temperatures down to -20 C.

MAC N-407 Air-Cooled Chiller

12 Technicaldata. Dimensions and setting-out coordinates 25-50

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Water chillers water/water type SIGMA Technical information manual

MAC-120HE-03 Air-Cooled Chiller

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

kw COOLING kw HEATING

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Technical data LA 60TUR+

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Ground source heat pump NIBE F1255

Savings and performance worth celebrating! The DHP-AQ new air source heat pump from Danfoss

User instructions DHP-AT

HIGH-POWER HEAT PUMPS. Up to 300 kw

SYSTEM DESIGN REQUIREMENTS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Technical data LA 60TU

MODULAR CHILLER. R410a R22

EHS. EHS (Mono, LT, 50Hz)

Water-Cooled Dual Compressor Screw Chiller

TCHE-THHE TCEE

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Ground source heat pump range. Why Vaillant? because we can unearth the energy.

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS

MACH N-407 Heat Pump Air-Cooled Chiller

Technical data LA 28TBS

Installation, operating and maintenance ECOLEAN - EAC/EAR

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Kälte Klima. Water cooled water chillers from 200 kw to 1550 kw. Screw Compressor LCWX DE 56 01/16 12/13

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro+ DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro+

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

50A KP 70A KP 90A KP 120A KP 150A KP 210A

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Providing sustainable energy solutions worldwide. Installation and Maintenance Manual CTC EcoHeat V 3N~ / 230V 1N~

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

your tree NEW TREE for you Several facts on trees: Follow our Green Tree heat pumps

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

ELFOEnergy Duct Inverter

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

AIRLINE - commercial heat pumps Air / water heat pump for heating, cooling and DHW production - commercial use

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Installation and Maintenance Manual CTC EcoHeat V 3N~ / 230V 1N~ Providing sustainable energy solutions worldwide

Technical data LA 9S-TU

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

TCHE-THHE TCEE

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

WZH Ground source heat pumps

Product Catalogue CG-PRC002E-EN. CGAD Liquid Chillers Air-Cooled Scroll Compressor 20 to 150 Tons. July Models: 50 / 60 Hz

HT V2 HT Split

21,8 222 kw COOLING 25,2 236 kw HEATING

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

NKW. Heater series HEATERS

Kälte Klima. Water cooled water chillers Not Reversible heat pumps from 18 kw to 75 kw. Series:

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

NIBE F1245 GROUND SOURCE HEAT PUMP. Heat pump with rock, ground or lake as heat source. NIBE F1245

Greenline HE C6-C11 E6-E17 Installer Guide

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

Air heater/cooler in combination with ground source heat pump

Heat pump range. Why Vaillant? Because we are a great source of heat pump solutions. geotherm geotherm air climavair

Capacity controller for water chiller AK-CH 650

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

MSRW MINI SERIES. Modular Water Cooled Scroll Chiller MSRW075 MSRW085 Nominal Capacity 73 to 1312 kw(r) Issue: 2.0 Date 07/08

Technical specifications

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

Transcription:

Technical data Danfoss DHP-L Heat pump with the same features as Danfoss DHP-H, but with separate hot water tank. Can reduce heating costs by more than 50 percent. Main parts... 2 Bipack contents... 3 Dimensions and connections... 4 Components... 5 Space requirement... 6 Sensors..... 6 Installation principle... 7 Auxiliary heating and energy consumption calculation... 8 Technical data... 9 Power output and COP graphs... 10 Pressure drop graphs - Warm side... 13 Pressure drop graphs - Cold side... 16 VFBMD402

Main parts 3 1 Heat pump unit Scroll compressor Stainless steel heat exchanger Circulation pumps for brine and heating systems Valves and safety equipment for cooling systems and corresponding electrical components. 2 Exchange valve The heated water either passes through to the heating system or to the water heater depending on whether heating or hot water is to be produced 3 Auxiliary heat 9 kw electric heating element (4.5 kw at 230 V heat pump installation) Electric heating element control in maximum of three steps Installed on the heating system s supply pipe Covers the demand of extra energy if the heat pump s capacity is exceeded Automatically connected in the heat pump unit if operating mode AUTO is selected. 4 Control equipment Control computer with graphic display Temperature sensors (outdoor, supply pipe, return pipe, brine and hot water) Room sensor (option) The control equipment controls the heat pup unit s included components (compressor, circulation pumps, auxiliary heaters and exchange valve) and determines when to start and stop the pump as well as producing heat for the house or hot water. 2 1 2 VFBMD402 Technical data

Bipack contents Sizes 4kW - 10kW: Part no. Quantity Name 086U2369 1 Safety valve 9 bar 1/2 Sizes 12kW - 16kW: Part no. Quantity Name 086U2369 1 Safety valve 9 bar 1/2 086U2701 1 Outdoor sensor Kimsafe 200 035 086U2701 1 Outdoor sensor Kimsafe 200 035 086U0896 1 Safety valve 1.5 bar 1/2 086U0896 1 Safety valve 1.5 bar 1/2 086U2824 1 Expansion and bleed tank without valve 086U2824 1 Expansion and bleed tank without valve 086U0026 5 Rubber collar hole 22-32mm 086U0026 5 Rubber collar hole 22-32mm 086U6033 2 Flex. hose DN20 L=550 086U6034 2 Flex. hose DN25 L=550 086U6006 1 Filling device brine DN25 086U6007 1 Filling device brine DN32 086U6005 1 Dirt filter with shut-off DN25 086U6005 1 Dirt filter with shut-off DN25 DHP-L VFBMD402 3

Dimensions and connections 379 1538 (±10) 110 440 300 1 2 341 216 4 3 139 219 299 6 5 116 528 421 7 610 80 455 40±10 596 690 The brine pipes can be connected on either the left or right-hand sides of the heat pump. Position Name 1 Brine in, 28 Cu 2 Brine out, 28 Cu 3 Heating system supply line, 22 Cu: 4-10 kw, 28 Cu: 12-16 kw 4 Heating system return line, 22 Cu: 4-10 kw, 28 Cu: 12-16 kw 5 Alternative for brine out 6 Alternative for brine in 7 Lead-in for supply, sensor and communication cables 4 VFBMD402 Technical data

Components 1 2 11 13 5 6 16 3 4 12 7 8 10 15 14 17 18 9 Left view Front view Right view Position Name 1 Auxiliary heater, immersion heater on supply line 2 Return line, heating system 3 Exchange valve 4 Evaporator, insulated 5 Heating system circulation pump 6 Supply line sensor, heating system 7 Brine out 8 Brine pump brine system 9 Drying filter 10 Expansion valve 11 Control panel for control equipment 12 Brine in 13 Electrical panel 14 Compressor 15 Low pressure pressostat 16 Operating pressostats 17 High pressure pressostat 18 Condenser with primary side drain DHP-L VFBMD402 5

Space requirement 1620 Necessary service space and minimum headroom for heat pump installation. Sensors Outdoor sensor Other sensors C Ohm C kilo-ohm -30 1884 0 66,3-25 1443 5 52,4-20 1115 10 41,8-15 868 15 33,5-10 681 20 27,1-5 538 25 22,0 0 428 30 18,0 5 343 35 14,8 10 276 40 12,2 15 224 45 10,1 20 183 50 8,5 25 150 55 7,1 30 124 60 6,0 35 103 65 5,0 40 86 70 4,2 75 3,7 80 3,1 85 2,7 90 2,3 95 2,0 Conversion table for sensors NOTE! When reading the resistance of the sensors, the sensor leads must first be disconnected from the control equipment. 6 VFBMD402 Technical data

Installation principle Safety valve Shut-off valve and strainer Supply line Return line Pressure gauge Flexible hoses Expansion tank Connection to any water heaters To outlet Safety valve, 1,5 bar Bleed and expansion tank Shut-off valve Brine out Brine in Filling kit incl. strainer Strainer DHP-L VFBMD402 7

Auxiliary heating and energy consumption calculation The auxiliary heater is made up of an electric heating element on the supply pipe that has two outputs, ADD.HEAT 1 and ADD.HEAT 2, and can be controlled in three steps: For three phase, 400V, installations: Step 1 = ADD.HEAT 1 = 3 kw Step 2 = ADD.HEAT 2 = 6 kw Step 3 = ADD.HEAT 1 + ADD.HEAT 2 = 9 kw For single phase, 230V, installations: Step 1 = ADD.HEAT 1 = 1.5 kw Step 2 = ADD.HEAT 2 = 3 kw Step 3 = ADD.HEAT 1 + ADD.HEAT 2 = 4.5 kw In the event of an alarm, the auxiliary heater engages automatically. The energy consumption calculation is difficult to specify exactly, but the average output for a normal house with normal hot water consumption in the following tables gives a relatively accurate result for each heat pump and heating system. Remember that the operating time for the heat pump installation must exceed one year before the specified values in the table are valid. The energy consumption for legion operation is included in the hours for ADD.HEAT 1. The indicated outputs include circulation pumps. DHP-L, -4-6 -8-10 -12-16 Under floor heating 1.13 kw 1.59 kw 2.00 kw 2,55 kw 2.90 kw 4.31 kw Radiators 1.39 kw 1.88 kw 2.36 kw 3.03 kw 3.43 kw 5.11 kw To calculate the energy consumption: 1 Press either the right or left button once to open the INFORMATION main menu. The cursor is in the OPERATION menu option. 2 Press the down button to move the cursor to the OPERAT.TIME menu option. 3 Open the menu by pressing the right button once. 4 Note how many hours the following values have: HEATPUMP, ADD.HEAT 1, and ADD.HEAT 2. 5 In the tables above find the value for the average output that corresponds to your heat pump and heating system, and multiply it by the number of HEAT PUMP hours. Note the result. 6 Multiply the number of ADD.HEAT 1 hours by 3. Note the result. 7 Multiply the number of ADD.HEAT 2 hours by 6. Note the result. 8 Add up the multiplied values to obtain the total energy consumption. 8 VFBMD402 Technical data

Technical data Heat pump DHP-L 4 6 8 10 12 16 Refrigerant Type R407C R407C R407C R407C R407C R407C Amount kg 0.75 1.20 1.30 1.45 1.55 2.00 Test pressure MPa 3.2 3.2 3.2 3.2 3.2 3.2 Design pressure MPa 3.1 3.1 3.1 3.1 3.1 3.1 Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Oil POE POE POE POE POE POE Electrical data 3-N Main supply Volt Rated power, compressor kw Auxiliary heater, max kw 3 steps Start current A Circuit breaker A Electrical data 1-N Main supply Volt Rated power, compressor kw Auxiliary heater, max kw 3 steps Start current A Circuit breaker A Performance 1 Output capacity kw Heat factor COP Nominal flow 6 Cooling circuit l/s Heating circuit l/s External available Cooling circuit kpa pressure 5 Heating circuit kpa Max/min temperature Cooling circuit o C Heating circuit o C Pressure switches Low pressure MPa Operating MPa High pressure MPa Anti freeze media Weight kg 400/50Hz 400/50Hz 400/50Hz 400/50Hz 400/50Hz 400/50Hz 2.7 2.0 2.3 3.6 4.4 5.6 3/6/9 3/6/9 3/6/9 3/6/9 3/6/9 3/6/9 36 14 25 29 32 45 1x16 7 10 2 /16 3 /20 4 16 2 /16 3 /20 4 16 2 /16 3 /20 4 16 2 /20 3 /25 4 20 2 /20 3 /25 4 10 2 /10 3 /16 4 230/50Hz 230/50Hz 230/50Hz 230/50Hz 230/50Hz * 2.7 3.3 4.2 5.4 5.7 * 1.5/3/4.5 1.5/3/4.5 1.5/3/4.5 1.5/3/4.5 1.5/3/4.5 * 36 58 56 97 108 * 1x16 7 25 2 /32 3 /40 4 25 2 /32 3 /40 4 32 2 /40 3 /50 4 32 2 /40 3 /50 4 * 20 2 /25 3 /32 4 3.2 4.9 7.2 8.9 10.7 15.2 2.6 2.8 3.1 3.2 3.1 3.2 0.2 0.3 0.5 0.6 0.6 0.9 0.1 0.1 0.2 0.2 0.3 0.4 31 31 33 32 64 56 47 44 42 39 51 57 20/-10 20/-10 20/-10 20/-10 20/-10 20/-10 55/20 55/20 55/20 55/20 55/20 55/20 0.08 0.08 0.08 0.08 0.08 0.08 2.65/2.85 2.65/2.85 2.65/2.85 2.65/2.85 2.65/2.85 2.65/2.85 3.10 3.10 3.10 3.10 3.10 3.10 Ethylene glycol/ Ethanol Ethylene glycol/ Ethanol Ethylene glycol/ Ethanol Ethylene glycol/ Ethanol Ethylene glycol/ Ethanol Ethylene glycol/ Ethanol 140 145 150 155 165 175 1) At B0W45 according to EN 14511 (including circulation pumps). 2) Heat pump with 3 kw auxiliary heater (1-N 1.5 kw). 3) Heat pump with 6 kw auxiliary heater (1-N 3 kw). 4) Heat pump with 9 kw auxiliary heater (1-N 4.5 kw). 5) Pressure drop that must not be exceeded outside the heat pump without the nominal flow being reduced. For the cooling circuit these values require a pipe of Ø 40x2.4. 6) Nominal flow: heating circuit Δ10K, cooling circuit Δ3K. 7) Fuse protection 1-phase compressor (only applies to size 4) * ) Not available in 230V 1-N version. DHP-L VFBMD402 9

Power output and COP (Coefficient of Performance) graphs The data shown in the graphs is according to EN14511 including circulation pumps. DHP-L 4, supply line 35 C No data is available for DHP-H 4 at this moment. This graph will be complemented in a later edition. DHP-L 4, supply line 45 C No data is available for DHP-H 4 at this moment. This graph will be complemented in a later edition. *) COP = Coefficient of Performance 10 VFBMD402 Technical data

Power output and COP graphs The data shown in the graphs is according to EN14511 including circulation pumps. DHP-L 6, supply line 35 C Heating capacity COP Power input DHP-L 6, supply line 45 C Heating capacity COP Power input DHP-L VFBMD402 11

Power output and COP graphs The data shown in the graphs is according to EN14511 including circulation pumps. DHP-L 8, supply line 35 C Heating capacity COP Power input DHP-L 8, supply line 45 C Heating capacity COP Power input 12 VFBMD402 Technical data

Power output and COP graphs The data shown in the graphs is according to EN14511 including circulation pumps. 13 12 DHP-L 10, supply line 35 C 11 10 Heating capacity 9 8 7 6 5 4 3 2 1 0 COP Power input 13 12 DHP-L 10, supply line 45 C 11 10 Heating capacity 9 8 7 6 5 4 3 2 1 0 COP Power input DHP-L VFBMD402 13

Power output and COP graphs The data shown in the graphs is according to EN14511 including circulation pumps. DHP-L 12, supply line 35 C 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Heating capacity COP Power input 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 DHP-L 12, supply line 45 C Heating capacity COP Power input 14 VFBMD402 Technical data

Power output and COP graphs The data shown in the graphs is according to EN14511 including circulation pumps. 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 DHP-L 16, supply line 35 C Heating capacity Power input COP 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 DHP-L 16, supply line 45 C Heating capacity Power input COP DHP-L VFBMD402 15

Pressure drop graphs - Warm side Heat pump, DHP-L4 Pressure drop warm side, estimated from measurements Volume flow, water (l/s) Heat pump, DHP-L6 Pressure drop warm side, estimated from measurements Volume flow, water (l/s) 16 VFBMD402 Technical data

Pressure drop graphs - Warm side Heat pump, DHP-L8 Pressure drop warm side, estimated from measurements Volume flow, water (l/s) Heat pump, DHP-L10 Pressure drop warm side, estimated from measurements Volume flow, water (l/s) DHP-L VFBMD402 17

Pressure drop graphs - Warm side Heat pump, DHP-L12 Pressure drop warm side, estimated from measurements Volume flow, water (l/s) Heat pump, DHP-L16 Pressure drop warm side, estimated from measurements Volume flow, water (l/s) 18 VFBMD402 Technical data

Pressure drop graphs - Cold side Heat pump, DHP-L4 Pressure drop cold side, estimated from measurements Volume flow, ethanol-water (l/s) Heat pump, DHP-L6 Pressure drop cold side, estimated from measurements Volume flow, ethanol-water (l/s) DHP-L VFBMD402 19

Pressure drop graphs - Cold side Heat pump, DHP-L8 Pressure drop cold side, estimated from measurements Volume flow, ethanol-water (l/s) Heat pump, DHP-L10 Pressure drop cold side, estimated from measurements Volume flow, ethanol-water (l/s) 20 VFBMD402 Technical data

Pressure drop graphs - Cold side Heat pump, DHP-L12 Pressure drop cold side, estimated from measurements Volume flow, ethanol-water (l/s) Heat pump, DHP-L16 Pressure drop cold side, estimated from measurements Volume flow, ethanol-water (l/s) DHP-L VFBMD402 21

VFBMD402