NAUTOCONNING (Ethernet) BOX -PC

Similar documents
Indicator Equipment OPERATOR MANUAL. Rate Gyro, Type Operator Unit, Type consisting of:

GMDSS Signal Unit POWER MONITOR

ALARM TRANSFER SYSTEM

7NG , 7NG

Assembly Instruction GfS Door Terminal

GENOVA PANORAMA MC. Future. Technology. Innovation.

WELCOME. The human touch in technology. marine

operating device LOD , 144x72mm designed for retrofit

Design. Innovations in Integrated Control Systems

Fully redundant and customizable alarm, monitoring & Control system

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

SOLUTIONS PROVIDER FOR THE SHIP AUTOMATION AND MARINE INSTRUMENTATION

COMPANY PROFILE. Design, Development & Installation of Electrical & Automatic Control Systems

USCG-EU MRA EC TYPE EXAMINATION (MODULE B) CERTIFICATE

Imtech Marine Free Technics. Type-approved, user-centered yacht automation

Technical Data Sheet BNWAS. Bridge Navigational Watch Alarm System. Technical Data Sheet. General Features

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

Strand Lighting Inc Darin Way, Cypress, CA 90630, USA Tel: Fax:

Manager Other (Specify) Gross Tonnage: Main Propulsion (kw): Generating Power (kw):

The SMART Choice of Control & Automation. always on top of the situation

GROUNDING AVOIDANCE SYSTEM (GAS)

BR

Technical Information

RULES PUBLICATION NO. 35//P ONE MAN BRIDGE OPERATED (OMBO) SHIPS March

1 Automotive Sensor System Architectures

GL-001. CIRM Guideline PERFORMANCE TEST PROCEDURE FOR ELECTRONIC CHART DISPLAY AND INFORMATION SYSTEM (ECDIS) Edition 1.

on board with solutions

NF EN V2/AC2 DÉCEMBRE Normes en ligne. Pour : CERN. Client : Commande : N T. le : 10/04/2018 à 17:39

Certificate. Production Quality System MODULE D. Certificate No. P 112

Publications and Training Solutions Course Syllabus:

PcVue Solutions. PcVue Solutions

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

Notified Body No.: 0575

EC-TYPE EXAMINATION CERTIFICATE (MODULE B)

CVEN x 1/1 GN 6-12 x 20 DEVICE FOR GASTRONOMY

CTU 2000 Series. Contamination Test Unit. Operating and Maintenance Instructions English. Doc e

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

Letter from GM BASIL AL HANBALI

is found to comply with DNV GL rules for classification Ships, offshore units, and high speed and light craft

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

WAGO-I/O-SYSTEM 750 Explosion Protection via Intrinsic Safety

CONTENTS INSTALLATION 21 USING THE SIGNAL KEY 10 SPECIFICATION 23

Notified Body No.: 0575

ClassNK Technical Information No. TEC-0838 (iii) The dormant period, visual indication, first stage audible alarm, second stage remote audible alarm a

FT NAVVISION AMCS TYPE-APPROVED, USER-CENTERED YACHT AUTOMATION

Modular Alarm, Monitoring and Control System

SCAN STEERING Excellent Navigation

Manual. Simrad IS20 Combi Instrument. English Sw. 1.2

PERFORM. PLUG. PLAY. BEST-IN-CLASS SENSING SOLUTIONS.

Innovations in Integrated Control Systems

Illuminated Stopper Station Push Button

Swan Song. Engine Rooms

CONTENTS USING THE LIGHTS KEY...31 NETWORK ALARMS...32 FAULT AND ERROR MESSAGES...33

Greenhouse Automation. Small or big solutions State-of-the-art and cost-effective.

BSR Addressable Fire Detection control panel. Installation operation manual

ONYXWORKS AND FIRSTVISION. Version 4

1.5. System description of Bridge Navigation Watch Alarm System (BNWAS 3000)

Engine Order Telegraph System (EOT) A067

E-16 Main Engine Remote Control System

2002 Fairline Phantom 43. Boat Type. Engines. Drive Type. Engine HP. Airtronic with 6 vents Draft. Air Conditioning. Anchor Windlass.

Preparing you for the new ECDIS regulations

Changed rules for alert management on the bridge

FT2080 Fire terminal (Touch) Mounting Installation

NAUTICAL SAFETY OFFSHORE SERVICE VESSELS

Foot control. No instrument selected. A Raise chair Chair to working position 1 B Incline backrest Chair to spitting. positioning

FT2080 Fire terminal (Touch) Mounting Installation

Accessories, interfaces, sensors and complete solutions.

2013 Gulfstream G550 N640W* S/N Specifications and Summary

Applicable international instruments for construction, performance and testing requirements 1

COMMISSION DIRECTIVE 98/85/EC of 11 November 1998 amending Council Directive 96/98/EC on marine equipment

Fire Detection Systems Product Catalogue (Version )

RESOLUTION MSC.86(70) (adopted on 8 December 1998) ADOPTION OF NEW AND AMENDED PERFORMANCE STANDARDS FOR NAVIGATIONAL EQUIPMENT

SIMPLY MORE SECURITY MOSRO

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

BlackBerry AtHoc Networked Crisis Communication Siemens Indoor Fire Panel Installation and Configuration Guide Release Version 7.

Selene 47 Alyeska. Number:

Technical Information

Lopolight navigation light control panel External monitoring and control. Protocol NMEA 0183 interface IEC:2010(E)

Product Catalogue. Complete Wireless Sensor Solutions SYSTEMS. 100% Peace of Mind! WEB ID WEB ID WEB ID

Modular Alarm, Monitoring and Control System

Más Costura Para El Hogar By Singer Sewing Reference Library;Staff Cy Decosse Inc

Connected Airports. Complete Airfield Ground Lighting Solution

1.6. Installation instructions for Bridge Navigation Watch Alarm System (BNWAS 3000)

Niagara4 Technical Certification Program Student Guide DAY 1 DAY 2

Concerning the use of GP4000 Series Graphic Operator Interface for applications in potentially explosive atmospheres (Zones 2/22)

International Maritime Group. All You Need At Sea

AUTOMATED CLIMBER DETECTION

WINDSHEAR STORM and WINDSHEAR STORM DELUXE MODEL NO: 98778/98780

DELOMATIC 400, DM-400 HYDRO

FOREFRONT AT THE OF PROTECTION

TELECOMMUNICATION. Telecommunication. Wireless Phone

I N T E L L I G E N T A S P I R A T I N G. Intelligent Aspirating Fire Detector. Intelligent Earliest Warning Aspirating Fire Detector

Energy Commander Paralleling Switchgear

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

SEQUENCE OF OPERATIONS

BCF1080 FORWARD PLATE COMPACTORS PARTS BOOK

STRIKE GUARD DELIVERS:

1991 CHALLENGER 601-3A/ER N83UF S/N 5083

OPUS20 LAN-Datalogger Future Inside

Transcription:

Raytheon Anschütz GmbH Postfach 1166 D - 24100 Kiel Tel+49-431-3019-0 Fax+49-431-3019-501 Email Service@raykiel.com www.raytheon -anschuetz.de NAUTOCONNING (Ethernet) BOX -PC System Description 4093.DOC000002

Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung ihres Inhaltes nicht gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlungen verpflichten zu Schadenersatz. Toute communication ou reproduction de ce document, toute exploitation ou communication de son contenu sont interdites, sauf autorisation expresse. Tout manquement à cette règle est illicite et expose son auteur au versement de dommages et intérêts. Copying of this document, and giving it to others and the use or communication of the contents thereof, are forbidden without express authority. Offenders are liable to the payment of damages. Sin nuestra expresa autorización, queda terminantemente prohibida la reproducción total o parcial de este documento, así como su uso indebido y/o su exhibición o comunicación a terceros. De los infractores se exigirá el correspondiente resarcimiento de daños y perjuicios.

R Raytheon Anschütz GmbH SAFETY NOTES: S Warning! Take care during maintenance and repair work: avoid touching live electrical connections. The applicable safety regulations such as VDE, VBG 4, OSHA 1919 and other appropriate safety standards must be followed. S The installation and first putting into operation may only be performed by trained and qualified personnel. S Maintenance and repair work may only be performed by trained and qualified personnel having knowledge of the national safety regulations for this type of equipment. S The equipment can be damaged! Parts may only be replaced when the supply voltage is switched off. A 4093DOC000002

4093DOC000002 B

R Raytheon Anschütz GmbH Table of Contents 1 General... 1-1 1.1 Tasks and Performance features... 1--2 1.2 Construction... 1--4 Diagrams: See Cable Diagrams and Connecting Diagrams (according to order) Additional Descriptions: Navigation Data Manager Conning Display Alarm Transfer System 3884E 4094E 4095E Computer 4090E I 3885DOC000002

R Raytheon Anschütz GmbH 1 General NAUTOCONNING is the central display and data management system for the ship s command. Allying with Radar and ECDIS (Electronic See Chart) NAUTOCONNING can be placed in a Multifunction Console (MFC). The switching over between these applications taks place with a software switch (MFC Switch) placed on the top corner right of the display. 1--1 4093DOC000002

1.1 Tasks and Performance features Read in and adaption of Navigation Data - Log - NavRec - Wind - Depth - etc. Read in and adaptation of Sensor Data - Compass - Autopilot - ECDIS - etc. Sensor Monitoring The Nautoconning software allows specific Alarm Level Settings for sensors which will release alarms on Alarm Transfer System ATS. Sensor Selecting Redundant sensors can be selected from a scrollable list which indicates all sensors and their current status. Registration and management of alarms and the status of system devices Built--in Watch Alarm Timer, configurable for W1--applications (Function of Alarm Transfer System Conning Display) Redundant Central Alarm Panel functionality for W1--applications 4093DOC000002 1--2

R Raytheon Anschütz GmbH Display of the registered data, alarms and procedure sequences (tracking) in corresponding monitor displays: - NAVIGATION - DOCKING - SENSOR - ALARM - ONDUTY - RECORD Distribution of the data and alarms to connected devices. 1--3 4093DOC000002

1.2 Construction (see Figure: 1--1) NAUTOCONNING is constructed modularly and can be adapted to the particular tasks of different types of vessels. This applies to interfaces to other equipment, sensors and to screen displays. NAUTOCONNING basically consists of Computer (see attached description no. 4090) Navigation Data Manager (see attached description no. 3884) Conning Display (see attached description 4094) The NAUTOCONNING--,ECDIS-- and RADAR--Application can be used in one console or computer. These option is called Multifunction Console MFC. As an option an Alarm Transfer System can be added (see attached description no. 4095). An Alarmmanager enables NAUTOCONNING to integrate an Watch Alarm System with Alarm Transfer System and Central Alarm Panel acc. to DNV. The Ethernet Switch is used as Data Distribution for the NAUTOCONNING Ethernet System. 4093DOC000002 1--4

R Raytheon Anschütz GmbH CENTRAL BRIDGE PLACE NAUTOCONNING DISPLAY ALARM PANEL used as CENTRAL ALARM PANEL Computer ALARM PANEL MFC *) NAVIGATION DATA MANAGER NMEA SENSORS or ETHERNET SWITCH ALARM TRANSFER SYSTEM NAVIGATIONAL SOURCES (e.g.) GL ONASS WIND GPS 1 GPS 2 ECHOSOUNDER GYRO LOG IR--NAV IR--TRACK AUTOPILOT NP20xx AIS ECDIS RADAR FC--NAV FC--TRACK VDR ALARM SOURCES RADAR ECDIS AUTOPILOT GYRO COMPASS CONNING ALARM NMEA ANALOG CONVERTER *) Multifunction Console Figure: 1--1 NAUTOCONNING SYSTEM (Overview) 1--5 4093DOC000002

4093DOC000002 1--6