Air distribution systems. Air distribution systems for assembly rooms

Similar documents
Air distribution systems. Displacement air outlets Low-turbulence air flow in the commercial sector

Air distribution systems. Ceiling air outlets Turbulent mixing air flow

Cleanroom systems. Supply air ceiling and recirculated air ceiling OP. for operating rooms with low-turbulence displacement flow

Air distribution systems. Sidewall air outlets Turbulent mixing air flow

Displacement air outlets Low-turbulence air flow in the industrial sector. Air distribution systems

Rectangular displacement outlet VA-RN... with adjustment device VA-RV...

Air distribution systems. Rectangular displacement outlet VA-RN... with adjustment device VA-RV...

Air distribution systems. Floor air outlets

Ceiling displacement outlet non-adjustable Q-DN... adjustable Q-DV...

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES

CRA24-B3 controlled residential ventilation

Air distribution systems. Opticlean OC-Q...

Installation Instructions

Return loss measurement of fiber optic components

Weishaupt WKmono 80. The next-generation burner for ratings up to kw. That s reliability

Accuracy counts! Sensors with analog output

Krantz. HVAC systems for hospitals. System solutions

C o o l i n g a n d h e a t i n g s y s t e m s

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

A WMIA Partner of the Year Winner S-Series Enclosureless Dust Collector

BFD Light Curtains The new choice for cutting edge safety for industrial doors

Textile fire protection closures EI 30/90

International standards used locally worldwide ISO/TC 67

KNX The worldwide STANDARD for home and building control. KNX Association International

Beckhoff short profile

Manusa Automatic. Doors. Safety beyond the Standard. EN16005 Power operated pedestrian doorsets. Safety in use. Requirements and test methods.

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

PRODUCT INFORMATION. SureSense THE SURE WAY TO DETECT ANY OBJECT. Photoelectric Sensors

The advantages of closed heating systems. White paper


Air distribution systems. Opticlean OC-Q... DS 4136 E /1

Labeling and Identification Products

Advantages of automatic boiler bottom blowdown

AutoM Click to go to the page. AutoM Auto Shaker Filter

Leading manufacturer of high-end ball valves and pneumatic actuators. Over 60 years experience with industrial applications

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

Future development of the furniture industry A look at the next 3-5 years

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

Expansion vessel in a solar installation. White paper

Compact FREME. flash recovery energy management equipment HEAT TRANSFER SOLUTIONS

KNX The worldwide STANDARD for home and building control. KNX Association International

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

PTG, SWT Series. Heat Recovery Systems

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

ASSEMBLY HALL AIR DISTRIBUTION

RETAIL TRADE AS AN ACTOR IN BALANCED SPATIAL PLANNING AND SUSTAINABLE DEVELOPMENT

Static cooling ceiling system SKS-4/3 DS 4094 E /1. Technical Selection

DESCRIPTION FEATURES WARNINGS APPLICATIONS

Fire-Resistant. Automatic Doors

Metal Woodprint The natural look

Metal Woodprint The natural look

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Air and dirt in closed systems

Rain Forest Quick Guide

Detect. React. Benefit. Increase the availability of your plants with SIMATIC Notifier!

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

A revolutionary development designed for expansive and connected living.

Floriculture. A world wide business and international challenges.??-??-2012, Nico de Groot

WORLDWIDE DISTRIBUTORS

STT 3000 Series STT250 /150 Surge Protection Device Specifications

Heinz Lux. Director, KNX

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

Value engineering developed from global experience

Passion for lighting since 1987 Quality is in our DNA Lighting; the development never stops

Battery Industry EFFICIENT APPLICATIONS SOLUTIONS

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

31 countries 1 internal market of safe products. Rapid Alert System for dangerous products 2015 RESULTS. Justice and Consumers

MJC Click to go to the page. MJC Cartridge Filter

STANDARD T6 (200 C) SENSOR CABLE RANGE

Displacement Ventilation

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

Signal converters SVE4 Product overview

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

an ISO 9001 Company Bulletin PR-112

Premium freezers combining functionality, elegance and energy efficiency

Krantz. Multifunction exposed ceiling AVACS. Cooling and heating systems

The industry standard. Shrink Tunnels

Urban Planning and Climate Change: OECD s perspective

stylemakerstm SINCE 1895

International Standards Health Informatics. Audrey Dickerson, RN, MS ISO/TC 215 Secretary

Ceiling diffusers. Type DLQL

PRODUCT PORTFOLIO OVERVIEW SENSOR SOLUTIONS: FOR MORE EFFICIENT AUTOMATION. Sensors, systems, and services

E-T-A Get Smart With Your Systems

AERO 20 AERO ENGLISH - Operating Instructions

EU directives WEEE and RoHS. Information and notes

Sundayz Long-lasting double flowers. Seeds and Seedlings

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

FieldLink Cable solutions for Automation & Drives

Ceiling air diffuser INDULTHERM INDULTHERM-e

Operation Manual Part-No

Live plants and products of floriculture sector in the EU

MKN Galley Solutions

Temperature Rises as Products Compete in the Heat. Market. Contact: Tim Page Press Release No: 20. Release date: Immediate Date: 11/11/09

From HOMI to. homimilano.com

Type Approvals GARAGE DOOR OPENER RADIO TRANSCEIVER. (EuroHomeLink 2000) Czech Republic CTU R 1194 Cyprus MCW129/95 12/2000 Denmark 98.

The best choice in hot air tools

MJB Click to go to the page. MJB Bag Filter

University of Westminster Student Exchange Partners. Not a partner? Come Study Abroad!

Transcription:

Air distribution systems Air distribution systems for assembly rooms

Air distribution systems for assembly rooms 1) Seat outlet M-DJ 20 db(a) Fixed desk outlet M-HP 26 db(a) Adjustable desk outlet M-LT 33 db(a) 2) For Q-Z: 105 l/(s. m) / 375 m 3 /(h. m) 3) At a standard height of 120 mm 4) Catalogue "Air distribution systems" 2

Air supply in assembly rooms, such as theatres, lecture halls and concert halls, places high requirements on air distribution systems. The following special criteria have to be taken into account: Great number of occupants Great room heights Low permissible sound levels Small percentage of external heat gain as adjacent outer walls and windows are frequently lacking Different room configurations, e.g. galleries, platforms, seating on stepped floors. The broad product range of KRANTZ KOMPONENTEN includes an assortment of air distribution systems for assembly rooms which have been in successful use for many years. Depending on kind and type, they are installed in the seating or in the floor, wall, or ceiling area. While the supply air is fed from the installation zone of the given air distribution system, the return air is extracted by the HVAC system in the ceiling zone. Air distribution systems for assembly rooms 3

Microclimate air distribution system Types M-DJ, M-HP, and M-LT The supply air is discharged from the seat back or the front edge of the desk. Prior to discharge, the primary air is admixed with a part of indoor air by pre-induction. The preinduction increases the discharge temperature of the supply air jets. This enables operation at a low primary air temperature, which raises the cooling capacity of the supply air volume flow rate. There are 3 types available: - Seat outlet, type M-DJ for installation in the seat back - Fixed desk outlet, type M-HP for installation in the front edge of the desk - Adjustable desk outlet, type M-LT for installation in the front edge of the desk M-LTI with induction device M-LTK without induction device A linear, turbulent free jet is formed. With the seat outlet and the fixed desk outlet, the jet angle is 70 to 90 to horizontal. The discharge direction is selected for direct, draught-free fresh air supply to the occupied zone. With the adjustable desk outlet, the discharge direction can be manually altered from 30 to 90 to horizontal. This means the air velocity in the occupied zone can be adjusted individually from perfectly draught-free to a fresh breeze sensation. This air outlet is also available without induction device. Seat outlet, type M-DJ Features: For assembly rooms with fixed seating Air supply through seat back or front edge of desk directly into the microclimate zone Linear, turbulent free jet Even temperature distribution around seated person due to pre-induction Stable, steady microclimate Connection to a pressurized plenum under the floor Technical layout to DS 4098 Air jet pattern of M-DJ Seat outlet, type M-DJ, at the 'MECC Maastrichts Expositie & Congres Centrum', Maastricht / NL Adjustable desk outlet, type M-LT, in the Second House of Parliament, The Hague / NL 4

Fixed desk outlet, type M-HP, in a lecture hall at the University of Vienna / A Fixed desk outlet, type M-HP Air jet pattern of M-HP Adjustable desk outlet, type M-LT Air jet pattern of M-LT at different, adjustable discharge angles Type M-DJ M-HP M-LT M-LTI M-LTK Primary air volume flow rate: l/s m³/h 5.5 11 20 40 5.5 11 20 40 5.5 11 20 40 5.5 11 20 40 Induction ratio: 1.4 1.3 1.5 1.0 Primary air temperature: C 18 18 18 19 Max. temperature difference supply air return air: K 11 Sound power level: db(a) 15 20 20 26 28 33 25 30 5

Seat displacement outlet Type Q-St For air distribution in assembly rooms with fixed seating. It is designed for connection to a raised floor/plenum. The seat leg is constructed as a perforated metal cylinder; it houses a distribution unit which evenly distributes the supply air from the pressurized plenum throughout the height of the perforated cylinder. The radially discharged air flows at very low, steady velocity and at low height over the floor. Features: For rooms with raised floors/plenums and fixed seating Air outlet built into seat leg Low-turbulence, radial and horizontal jet spread over the floor Very low sound power level Suitable for any seat design Volume flow rate: Min. supply air temperature: Max. temperature difference supply air return air: Sound power level: Nominal diameter: up to 14 l/s up to 50 m³/h 20 C K 16 db(a) DN 100, DN 127, DN 190 Standard height: 200 mm Technical layout to DS 4028 Left: Seat displacement outlet, type Q-St Right: Air jet pattern of Q-St Seat displacement outlet, type Q-St, in the 'Stella Musical Theater', Berlin / D Seat displacement outlet, type Q-St, in the 'Muziekgebouw aan 't IJ', Amsterdam / NL 6

Step displacement outlet Types Q-SL and Q-SR For air distribution in assembly rooms with raised floors and seating arranged on steps. The seating can be fixed or removable. The air outlet is built into the step front and is available in 2 types: - Linear step displacement outlet, type Q-SL with rectangular frontal plate - Circular step displacement outlet, type Q-SR with circular frontal plate. Step displacement outlet, type Q-SL, in a lecture hall at the Lausitz University of Applied Sciences, Cottbus / D The linear outlet is variable in length and its height depends on the step height. With curved step fronts, the linear outlets can be arranged in polygons. A built-in jet straightener raises the air jet direction, thus preventing jet constriction and jet acceleration. Step displacement outlet top: type Q-SL bottom: type Q-SR Air jet pattern top: type Q-SL bottom: type Q-SR Step displacement outlet, type Q-SR, at 'Kölnarena', Cologne / D The circular step displacement outlet discharges the supply air at low turbulence both axially and radially; this is why the outlet protrudes 7 mm from the step front. The centre distance between 2 circular step displacement outlets is at least 500 mm. Features: For rooms with steps and raised floors Air outlet built into step front Low-turbulence supply air flow close to floor Low sound power level Technical layout to DS 4054 Type Q-SL Q-SR DN 80 DN 100 Air volume flow rate: 21 l/(s. m) 1) 75 m³/(h. m) 1) 10 l/s 35 m³/h 16.5 l/s 60 m³/h Min. supply air temperature: Max. temperature difference supply air return air: 19 C K 19 C K Sound power level: Standard height: Depth: Length: 15 db(a) 120 mm 2) 75 mm variable 27 db(a) 146 mm 3) and 212 mm 3) 80 mm - 1) For standard heights of 120 mm 2) Other heights on request 3) As diameter 7

Step twist outlet Type DS For assembly rooms with seating arranged on steps. The air outlets are inserted into the step front. The air outlet element is available in 3 types: - Twist outlet, type DS-DD DN 63 and DN 100 Material: plastic - Radial outlet, type DS-RA with circular or square visible face DN 100 Material: sheet metal, painted - Adjustable floor outlet, type DS-BA DN 150 adjusted for displacement ventilation Material: plastic The advantage of radial, turbulent discharge of supply air is quick temperature equalization between supply air and indoor air. From about 0.5 m height above the floor the air flow - similar to a displacement flow - is directed upwards and displaces the warm, stale indoor air to the ceiling zone where it is extracted. Features: For assembly rooms with stepped floors, with fixed or removable seating Built into the step front Turbulent, radial supply air flow with intensive admixture of indoor air, hence quick reduction of jet velocity and rapid temperature equalization Installation in wooden or concrete steps Air supply via a pressurized plenum Top: Step twist outlet, type DS-DD Bottom: Step twist outlet, type DS-BA Step twist outlet, type DS-RA top: with circular visible face bottom: with square visible face Air jet pattern of DS-DD, DS-RA, and DS-BA Step twist outlet, type DS-DD, in a lecture hall at the University of Amsterdam / NL Type DS-DD -DN 63 DS-DD -DN 100 DS-RA DS-BA Max. air volume flow rate: l/s m³/h 3.5 12 10 35 10 35 10 35 Number per seat: 3 1 1 1 Min. supply air temperature: C 18 18 18 18 Max. temperature difference supply air return air: K Sound power level: db(a) 12 16 18 14 Outside diameter: mm 110 165 150 172 Min. centre distance: mm 150 500 500 500 Technical layout to DS 4065 8

Floor twist outlet Type DB-E For assembly rooms with set seating arrangements, with or without steps. The DB-E-DN 200 floor twist outlet is placed under the seat. The supply air is discharged vertically upwards as a turbulent jet. The air jet is deflected in the lower segment of the seat; it spreads in an umbrella shape around the person and then moves upwards as a displacement flow. Due to the intensive induction effect of the supply air jets, the jet velocity declines rapidly so that the air velocities in the leg zone of the seated person do not exceed 0.15 m/s. Floor twist outlet, type DB-E, in the 'Theater Markant', Uden / NL The air outlet is supplied with a perforated distributor basket with fixed damper. The air is supplied from a pressurized plenum; the distributor basket evens the distribution of the air volume flow rate within this plenum. Features: For assembly rooms with set seating arrangements Placement under seat Vertical, turbulent air jet with intensive admixture of indoor air in the floor zone Draught-free indoor air flow Air outlet with distributor basket Air supply via a pressurized plenum Floor twist outlet, type DB-E (in stepped bore) Floor twist outlet, type DB-E (with clamp insert) Distributor basket, VL type Max. air volume flow rate: Nominal diameter: Min. supply air temperature: Max. temperature difference supply air return air: 11 l/s 40 m³/h DN 200 18 C K Perforated distributor basket of type VL with silent fixed damper for even distribution of the air volume flow rate within the plenum Sound power level:: Technical layout to DS 1146 18 db(a) Air jet pattern of DB-E Floor twist outlet, type DB-E, in the media centre of Osaka University of Commerce, Osaka / J 9

Some installation examples Adjustable radial outlets in the foyer of 'Theater Schouwburg Tilburg' / NL Step displacement outlets at Beiersdorf AG, Hamburg / D Linear whirl outlets in the Hall of Honour of 'Casino Kursaal Ostende' / B Swivel jet nozzles in the 'Theater Tuschinski', Amsterdam / NL 10

Twist outlets in the foyer of 'Het Concertgebouw', Amsterdam / NL Step displacement outlets in the Municipal Theatre at Klagenfurt / A Jet nozzles and seat displacement outlets in the 'Muziekgebouw aan 't IJ', Amsterdam / NL Floor twist outlets at the University of Osaka / J Seat displacement outlets at the 'Konrad-Adenauer-Stiftung', Berlin / D Plinth displacement outlets at 'Kunsthalle Bremen' / D 11

You will find full details of our agencies at www.krantz.de Sales agents in Germany Agencies worldwide Europe Africa America Asia Oceania Krantz GmbH Uersfeld 24, 52072 Aachen, Germany Phone: +49 241 441-1, Fax: +49 241 441-555 info@krantz.de, www.krantz.de Aachen Dresden Frankfurt Dreieich Hamburg Munich Stuttgart Austria Belgium Cyprus Denmark Finland France Greece Great Britain Iceland Ireland Italy Netherlands Norway Poland Portugal Russia Spain Switzerland Turkey South Africa Canada Mexico United States of America Bahrain China China - Hong Kong Japan Kuwait Qatar Singapore South Korea Taiwan Thailand United Arab Emirates Australia New Zealand K 161e/06-1 Subject to technical alterations