PGW36. WALk-IN PLANT GROWTH. WALk-IN

Similar documents
Reach-In. PLanT GROWTh. Reach-In

Plant Growth Chamber MPGR14

Plant Growth Room MBDW Walk In Room

Tissue Culture Room MTCR

SPC-7-2H SHORT PLANT.

TPR. Features: TALL PLANT

SPC-56 SHORT PLANT.

TCR. Features: TISSUE CULTURE

TCC-34. Features: TISSUE CULTURE

BDR16 User Manual ENG R00

20 Series INSTALLATION MANUAL ENG-R00

E7/2 and E8 Chambers. Installation Manual ENG R00

Controlled Environment Equipment Solutions for the Lab

Stability & Shelf Life

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

VWR symphony CO 2 INCUBATORS

CLIMATRON GROWTH CABINETS

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

Laboratory Pharmacy Blood Bank. Upright Refrigerators and Freezers

STABILITY ICH. ICH Stability Tests

Heated and Refrigerated Incubators

Refrigerated Incubators / Environmental Testing Chambers

FITOCLIMA 600 & 1200 STABILITY

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

FITOCLIMA 600 & 1200 PHARMA

Air-Cooled Condensing Units with Compact Screw Compressors

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

Thermo Scientific Forma Environmental Chambers. Controlled Temperature Storage Solutions

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Solar Walk In Cooler Robust Construction, Technology, Quality, Reliability and Repeatability for extreme Tropic Conditions

FITOCLIMA 600 & 1200 STABILITY

Ultra-Low. Temperature. Freezers. Advantage Series. Basic Series. Microprocessor Control. Solid-State Electronic Control

REFRIGERATED AIR DRYERS

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

- TECHNICAL NOTES SUPPLEMENT TO PROJECT WORKSHEET -

Model KBWF 240 Growth chambers with light and humidity

HX Series. Compressed Air Dryers 10 to 2400 scfm. Setting a new standard in Quality and Reliability DRYMAX DRYMAX DRYMAX

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

FITOCLIMA 600 & 1200 BIO

62DA,DB,DC,DD,DE,DF07-38

PHOTOSTABILITY CHAMBERS

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

Platinous. temperature. and humidity. chambers. Top Quality Design. With an Easy-to-use. Touch-Screen. Programmer

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

Thermo Scientific Precision Ovens

plus a wide temperature range

CHAPTER 4. HVAC DELIVERY SYSTEMS

Constant climate chambers

DRYAIR Turnkey Dry Room Standards

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

30GN FLOTRONIC II AIR-COOLED CHILLERS

Constant climate chamber with ICH-compliant illumination

Environmental Chambers. 2-Door & 3-Door Extra Large Capacity

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

Clean, Dry Air System

"ESDDR" Series Electric Humidifier

Glass Doors, Hinged Bottom Mounts

30GT FLOTRONIC AIR-COOLED CHILLERS

NFZP Variable Refrigerant Flow Guide Specification

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

ULTRA LOW TEMPERATURE FREEZER. User Manual

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

-86ºC-Freezer. Ultra-Low Temperature Chest freezers: MDF-792 MDF-592 MDF-492 MDF-392 MDF-293 MDF-192

FitoClima / FitoTerm SOL chambers

SECTION AIR COILS

Thermo Scientific Forma Environmental Chambers. Controlled Temperature Storage Solutions. Optimum uniformity. plus a wide temperature range

APC APPLICATION NOTE #119

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

TB SERIES. Glycol Pizza/Salad/Sandwich Prep Tables Self-Contained. Project Quantity Item # Model Specified: CSI Section 11400

Guide Specifications PART 1 GENERAL 1.01 SUMMARY

Climate Control System

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Model KBWF 720 Growth chambers with light and humidity

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Laboratory refrigerators and freezers

Freeze Dry Systems and Accessories

NEW! Thermo Scientific Revco PLUS -86 C Freezers. Protecting Your Life s Work

Freeze Dry Systems and Accessories

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Product Specifications. Vertical Floor Consoles By First Co.

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

Installation & Service Manual

SNIJDERS LABS EXPERIENCED INNOVATORS. MICRO CLIMA SERIES ARABIDOPSIS CHAMBER, type MCA1600. MCA1600 Pagina 1 van 11 STEK ISO9001:2008 CERTIFIED

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING

REFRIGERATION PRODUCTS

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful.

Transcription:

PGW36 WALk-IN PLANT GROWTH WALk-IN

PGW36 walk-in PLANT GROWTH Product Overview/Applications The PGW36 equips the researcher with a walk-in environment which is accessible from four large doors two on the front of the chamber and two on the back. This model is often employed, and is ideally suited, for research involving taller classified plants. Its extended growth height ensures that most plants can be grown to full maturity within a moderate to high light regime. Also uniquely designed for the PGW36 is the ability to operate below freezing, while incorporating full daylight cycles. This low temp operation can be performed without the need for defrost operation (which can necessitate an undesirable lights-off event). Lighting The standard lighting package for the PGW36 generates midlevel light intensity, using both fluorescent and incandescent lamps, which results in a broad based lighting spectrum ideally suited for plant growth. Lamp groups can be programmed separately allowing for multiple lighting levels while Conviron s manually adjustable Lightright TM canopy enables the researcher to easily raise and lower the lamps to the proper height above the research material. Higher light intensities area available on this model. Airflow Airflow for the PGW36 is distributed uniformly upward using Conviron s innovative Unifloor air distribution plenum. The unit includes fresh air intake and exhaust ports which are adjustable to allow up to 55 ft 3 /min (1.55m 3 /min.) of air exchange. methods are available depending on site-specific and/or userdefined requirements. Consult the factory for heat rejection information and other refrigeration options. Experiment Protection User programmable set and forget alarms track the chamber s operation versus user-defined set points. This allows for exceptionally accurate monitoring without the need for adjustment every time the set point is redefined. Backup high/ low alarms provide a further level of protection while visual and audible notification is provided when any alarm is activated. Contacts for connection to a building management system are also included. Key Product Attributes Large and accessible growth space for higher light mature plants Conviron s Lightright TM canopy height adjustment system for enhanced flexibility of light intensity Efficient growth area-to-footprint ratio Product certifications/markings; CSA (NRTL), CE C US Refrigeration Cooling for the PGW36 is provided by a self-contained watercooled condensing unit with hot gas bypass for continuous compressor operation. An electronic modulating valve provides tight temperature control while ensuring quiet operation. Pressure transducers are included for monitoring the status of the refrigeration system. Alternative refrigeration Performance Data Temperature Range ( C) Interior Capacity Growth Area Growth Height Exterior Dimensions (WxDxH) Light Intensities (6in. from lamp) Electrical Service Weight 10 45 lights on 240ft ³ 36ft ² 80.25 134 x 60 x 99.75 860 µmoles/m ² /s 120/208-3Ø-60Hz 3655lb. 4 45 lights off (6700l) (3.3m ² ) (2040mm) 3410 x 1525 x 2535 (mm) @ 25 C 220/380-3Ø-50Hz (1658kg)

1.0 Control System: Conviron CMP6050 2.0 Construction: (Note: All dimensions are nominal.) 2.1 Exterior Dimensions: 134 W x 60 D x 99.25 H (3410mmW x 1525mmD x 2535mmH). 2.2 Interior Dimensions: 98 W x 54 D x 93 H (2490mmW x 1370mmD x 2350mmH). 2.3 Floor: Perforated aluminum channel floor for uniform upward air flow - Unifloor. 2.4 Subfloor: Molded resin fiberglass construction with floor drain. 2.5 Growth Area: 36ft ² (3.3m ² ). 2.6 Growth Capacity: 240ft ³ (6700 liters). 2.7 Growth Height: 80.25 (2040mm) from Unifloor to Lightright TM in the UP position. 2.8 Exterior Finish: Blue-green enamel baked on patterned aluminum. 2.9 Interior Finish: Reflective white enamel baked on smooth aluminum. 2.10 Conditioning Compartment: Stainless steel drain pan for corrosion protection. 2.11 Cabinet Construction: CFC-free insulation. 2.12 Doors: Four reach-in doors with light tight gaskets and keyed magnetic locks, each clear opening 29.75 x 76 (755mm x 1930mm). 2.13 Control Panel: Left hand (right hand model optional). 2.14 Instrument Ports: Two ports, 1 (25mm) with light tight caps. 2.15 Convenience Receptacle: Two (2) electrical receptacle located in lamp canopy. 3.0 Lighting: 3.1 Intensity 1 : Approximately 860 micromoles/m ² /s (Higher light intensities are optional) 3.2 Programming and Control: Independent, 4 level programming of each light type. 3.3 Lamps: Balanced spectrum for plant growth using fluorescent (T8 60Hz, T5 50Hz) and halogen incandescent lamps. 3.4 Lamp Fixture: Counterbalanced for adjustable light intensities - Lightright TM 3.5 Lamp Heat: Removed by refrigeration system. 3.6 Ballasts: High efficiency electronic and easily accessible. 3.7 Light Meter: Quantum light meter for display and recording of light output. 4.0 Temperature Control: (Maximum design ambient temperature is +35 C) 4.1 Range: +4 C to +45 C lights OFF, +10 C to +45 C lights ON. 4.2 Control 2 : ±0.5 C, at control point. 4.3 Temperature Safety Limits: Primary: Secondary: A programmable min and max temperature limit alarm or a limit tracking alarm that automatically follows the programmed set point An independent factory-set high and low temperature limit is also provided for increased assurance. An audible alarm is standard for both limits. Activation of temperature safety limit set points turns off power to the chamber. 1 Average light measurement at 6 (150mm) from lamp barrier on a 6-inch grid, chamber temperature of 25 C. Light intensities are nominal values measured at the rated chamber supply voltage. (Measured by a LI190 Quantum Sensor). 2 Measured by Precision Thermistors, measured without test materials or optional accessories.

4.4 Telensair : This vertically adjustable sensing device located in the growth area directs a continuous sample of chamber air over the remote sensors for accurate controlling and recording, unaffected by lamp radiation. 5.0 Refrigeration: 5.1 Condensing Unit: Cabinet is supplied with a water-cooled hermetically sealed condensing unit with hot gas bypass system for continuous compressor operation, extended compressor life and close temperature control. Condensing unit is located in the machine compartment, and includes a 3-way water modulating valve and hand operated shut off bypass valve. Maximum pressure drop across the condenser and water valve not to exceed 10pis (0.7 bar). 5.2 Valve: Electronic modulating valve that smoothly regulates the heating and cooling functions of the chamber. 5.3 Heat Exchanger Coil(s): Copper-tubed construction. 5.4 Refrigerant: Refrigeration system is charged with CFC-free refrigerant. 5.5 Montoring: a) Refrigeration system operation is monitored by the control system, including visual and audible alarm. b) Pressure transducers allow for real-time diagnostics for preventative maintenance & repair. 6.0 Air Flow: 6.1 Vertical: Uniformly upward through the entire growth area. 6.2 Fresh Air: Filtered inlet and adjustable exhaust 55ft ³ /min (1.55m ³ /min). 7.0 Humidity Control: (Optional) 7.1 Range: No control on basic unit. Refer to Humidity under Optional Accessories) 8.0 Carbon Dioxide Additive Control: (Optional) 8.1 Range: No control on basic unit. (Refer to Carbon Dioxide Additive Control under Optional Accessories) 9.0 Utility Requirements 3 : (Rating increases with some options.) 9.1 Electrical Service: 60Hz: 50Hz (Alternative services available, consult factory) 120/208-3Ø-60Hz-4 wire plus ground 220/380-3Ø-50Hz-4 wire plus ground 9.2 Drain: Floor drain must be provided outside footprint of cabinet. 10.0 Installation: (Optional) 10.1 Not included, to be performed by others. Installation is available upon request, please consult factory. 10.2 Should installation or technical support be required thorough Convirons Technical Service group, additional charges may apply. 3 This unit will tolerate ±10% voltage fluctuation from the rated voltage on the serial plate. A voltage stabilizer must be used if the fluctuation is greater than ±10%. Failure to do so can result in serious damage to the compressor and electronic components and will void warranty. Disconnect switch must be sized by a local qualified electrician.

OPTIONAL ACCESSORIES PROGRAMMING See Control System documentation UPS Uninterrupted Power Surge protection and uninterrupted power supply, on controller only, for continuous Supply operation of the controller during power interruptions, duration of the UPS is approx. 15 minutes. (Consult factory for increased duration, if required.) TEMPERATURE LT Low Temperature (No fresh air below 4 C.) A defrost cycle will occur resulting in a temperature increase for Operation temperatures set below 10 C lights ON, or 4 C lights OFF. Temperature deviations and defrost time are dependant on chamber operating temperature. During the defrost cycle, the lights will be turned off. Specified light intensity will be reduced when chamber is operating at low temperatures. With temperature ranges below 0 C; cabinet shall include drain pan, drain line and door heaters. Temperature ranges below 4 C with additive humidity option; cabinet shall include purge function. (Consult factory with requirements.) LTC Continuous Low Temperature A system designed to continuously maintain temperature below freezing with no significant deviation in the temperature during defrost. (Consult factory for temperature range.) LIGHTING M10T5 High Light Fluorescent/incandescent light intensities giving approximately 1270 micromoles/m ² /s using T5 fluorescent and halogen incandescent lamps plus end lamps. Independent, 8 level programming of fluorescent, halogen incandescent lamps plus end lamps. (Temperature range becomes +4 C no lights, +8 C half lights and +10 C all lights; reduces growth height by 3 [75mm].) Note: Amp draw changes, please consult factory. HID4 High Intensity High intensity discharge lighting using metal halide and high pressure sodium lamps Discharge Lighting with a light intensity of 1200 micromoles/m ² /s at a distance of 1 meter from the barrier. System utilizes our Lightright TM counterbalanced lamp canopy with lamps separated from growth area by a barrier with openings to allow chamber air to cool the lamps. Upon start-up, lamps experience a 5 to 10 minute warm up period before full light intensity is achieved. Note: HID canopy reduces growth height by 9.5 (240mm). Amp draw changes, please consult factory. Please contact the factory for other lighting possibilities. HUMIDITY (Based on +21 C and 50% RH ambient condition) DHS Dry Humidity Sensor Dry Electronic Sensor that directly measures and displays relative humidity in %RH by means of constant display on the CMP6050. (Not required if ordering additive humidity control option.)

SNH Spray Nozzle Range: Up to 85% RH lights ON/OFF, limited by a +25 C maximum dewpoint. Humidification Additive humidity through use of spray nozzles. Range given in an empty chamber. Chamber may achieve higher levels with plant loading. Programming: See Control System documentation. Control: ±3% RH. System uses a dry humidity sensor to directly measure humidity in %RH (no wet sock). Spray nozzles require a 60 psi (4.2 bar) pressure and must be supplied with clean water to the following specification; ph = 7.0 ± 0.5, filtration <2 microns (0.00008 in) and resistivity between 0.5 and 1.0 Meg Ohms. Maximum water usage to maintain specified levels is 6 liters/hr. If the above water pressure is not available the CPSNH option is required to supply necessary pressure. Note: When ordered with units requiring temperatures below 4 C, humidity system is provided with a low pressure air clean out system. Low pressure air must be supplied to cabinet (35 psi). (When combined with M10 option, maximum humidity level with lights ON is 75% RH.) CPSNH Compact Pump Spray Compact pump and reservoir for spray nozzles. Order this option with SNH if the Nozzle Humidification minimum 60 psi (4.2 bar) water pressure is not available. Supplies pressurized water for up to 12 nozzles. RES Reservoir Pressure reservoir at downstream chambers. Must be ordered for all downstream chambers fed from CPSNH. BDH Bypass Dehumidification A precisely controlled volume of chamber air bypasses the heat exchanger by means of a proportionally controlled air damper. Using excess capacity in the refrigeration system, moisture is removed from the remaining air by cooling and reheating. Note: 1. Amp draw increases, please consult factory. 2. Available with GLY option (please contact factory with requirements). 3. Must be ordered with additive humidity control option. CD Dehumidification by Chamber air is passed over a desiccant such as titanium silica gel to remove moisture. Chemical Dryer The dry air is re-introduced into the chamber at very low humidities. Chemical dryers offer the greatest degree of dehumidification. (Please contact factory with requirements.) CARBON DIOXIDE ADDITIVE CONTROL CO 2 Carbon Dioxide Package includes gas analyzer, CO 2 regulator (North America only), control valve, and Additive Control injection system. CO 2 tank not included. CONSTRUCTION GH96 Growth Height Extension Extended growth height by an additional 16 (405mm). Exterior height becomes 118.5 (3010mm). GH144 Growth Height Extension Extended growth height by an additional 64 (1625mm). Exterior height becomes 164 (4170mm). RHC Right-Hand Control Panel Right-hand control compartment gives you the convenience and flexibility to arrange your chambers in a compact orderly fashion, back to back and end to end, or to facilitate its location in any appropriate space. DD Deduct Doors If access from both sides of the growth area is not required, up to 3 doors may be deducted, reducing your cost. OW Observation Window 11 x 15 (280mm x 380mm) dual pane with light tight cover. (Please specify quantity and door)

CBS Bench Shelving Free-standing, adjustable corrosion resistant wire benching covering entire growth area. GA Additional Cabinet Sealing Construction for gas injection experiments. Consists of silicone sealed joints laboratory type inlet and exhaust valve, oil-filled manometer, adjustable hinges and well-fitting gaskets plus a valved condensate drain. (Does not provide a gas tight environment.) TXD Damper Tight-Fitting Exhaust Damper. MAN Manual Additional Operator s Manual. (One supplied with basic unit.) REFRIGERATION RAC Remote Outdoor Remote outdoor air-cooled condenser complete with all weather housing, low ambient Air-Cooled Condenser operation controls and low noise level operation. Remote location (up to 50 [15m] combined horizontal and vertical distance) of condenser only, compressor, receiver and other refrigeration components remain in cabinet machine compartment. Order RACH for climates with ambient temperatures from +35 C to +45 C for extended periods. Electrical: 60Hz - 208-230-1Ø-60Hz-3wire plus ground, 50Hz - 220-1Ø-50Hz-2 wire plus ground. Consult factory for amperages. Note: 1. Inter-connecting refrigeration and electrical lines are not included and must be provided by others. 2. RAC and RACH require a separate electrical service. 3. For remote location distances over 50 (15m) please consult factory. GLY Glycol Glycol heating/cooling designed to work with a central chiller refrigeration system. Includes proportional valve control. FMC Floor Mounted Compressor Floor mounted compressor located away from the growth chamber if a remote installation is desired. OACU Outdoor Air-Cooled Outdoor air-cooled condensing unit containing condenser, compressor, receiver, suction Condensing Unit accumulator, control and pressure regulating valves and electrical disconnect. The OACU comes complete with weatherized hood and crankcase heater for low ambient conditions. Inter-connecting refrigeration and electrical lines are not included and must be provided by others. OACU requires a separate electrical service. Electrical: 60Hz - 208-3Ø-60Hz-3wire plus ground, 50Hz - 400-3Ø-50Hz-3 wire plus ground. Consult factory for either amperages or other voltages available. ESSENTIAL SPARE PARTS ESP Essential Spare Parts Consult factory. SLS Spare Lighting Set Consult factory. SLSM10 Spare Lighting Set Includes 5 x ballasts, 4 x pairs of fluorescent sockets, 4 x incandescent sockets, 90 x for M10T5 fluorescent lamps (192 fluorescent lamps export only) and 45 x incandescent lamps. ISO9001 REF: SPEC - PGW36 Rev.: 0, 1 Nov 09 Printed in Canada. 2009 Controlled Environments Limited. Conviron is a registered trademark of Controlled Environments Limited. All other trademarks are the property of their respective owners. Information subject to change without written notice. www.conviron.com info@conviron.com

NOTES: 1. STANDARD REFRIGERATION SYSTEM IS WATER COOLED (1/2"Ø (13mmØ) CONNECTION). 2. DEPTH DIMENSION IS CHAMBER SIZE ONLY. DIMENSION DOES NOT INCLUDE DOOR LATCH OR PIPING ON BACK WALL. 3. LENGTH AND WIDTH DIMENSIONS ±1/4 (6mm). HEIGHT DIMENSION ±1" (25mm). DO NOT SCALE DRAWING. 99 11/16" (2530mm) FRONT ELEVATION 163 11/16" (4160mm) RIGHT HAND CONTROL PANEL GH96 OPTION GH144 OPTION PLEASE CONTACT FACTORY FOR RECOMMENDED CLEARANCE REQ'D FOR SERVICE AND INSTALLATION 115 5/16" (2930mm) 118 3/8" (3010mm) CONTROL PANEL FRESH AIR COUNTERBALANCED LAMP CANOPY (LIGHTRIGHT) EXHAUST AIR TELENSAIR UNIFLOOR INSTRUMENT PORTS (2) AIR FLOW SECTION A-A 54 1/2" 134 3/16" (3410mm) (1385mm) 35" (890mm) INCLUDES LATCH A CONDENSER WATER CONNECTION POINT (SEE NOTE 1) 60" (1525mm) PURIFIED WATER CONNECTION 1/4"Ø (6mmØ) (OPTIONAL) DRAIN LINE 1"Ø (25mmØ) 35" (890mm) INCLUDES LATCH PLAN VIEW A ELECTRICAL CONNECTION POINT PGW36 DATE ISSUED: 06/04/09 DRAWING NO.231158