HOT WATER SYSTEMS.

Similar documents
HOT WATER SYSTEMS.

HOT WATER SYSTEMS. thermann.com.au

EVACUATED TUBE SOLAR HOT WATER SYSTEMS OWNERS MANUAL JULY 2013 BROCMISC100.1

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50-6/16LP50-6, 16NG60-6/16LP60-6, 20NG50-6/20LP50-6, 20NG60-6/20LP60-6, 26NG50-6/26LP50-6, 26NG60-6/26LP60-6

Apricus Residential Solar Hot Water Systems CLICK TO START

DUX WATER HEATERS HOT WATER SOLUTIONS PRODUCT GUIDE

DUX WATER HEATERS HOT WATER SOLUTIONS PRODUCT GUIDE

Air Conditioning range 2010 Hot Water Systems

DUX WATER HEATERS GAS HOT WATER SOLUTIONS. Bunnings can replace your old hot water system and install a new one fast!

GAS WATER HEATERS HOT WATER SOLUTIONS PRODUCT GUIDE

Hot Water Systems. Gas Continuous Solar Systems Heat Pumps

QUANTUM. Reliable solar hot water, whenever you want it

Innovative, Energy Efficient Water Heating Technology

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

economy environment engineering excellence Advanced Commercial Hot & Warm Water Solutions

Soak in the Sunshine. Solar Hot Water

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

RAYPAK HOT WATER & HEATING

RAYPAK HOT WATER & HEATING

Dux Water Heaters CLICK TO START

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER

DUX WATER HEATERS ENVIRONMENTAL HOT WATER SOLUTIONS. Bunnings can replace your old hot water system and install a new one fast!

DUX WATER HEATERS ELECTRIC HOT WATER SOLUTIONS. Bunnings can replace your old hot water system and install a new one fast!

our range Page 2 USE TOOLBAR TO NAVIGATE

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

INSTALLER'S MANUAL. Gas Continuous Flow Condensing Water Heaters. Installation Details Warranty. Models 26NG50C/26LP50C 26NG60C/26LP60C

RHEEM DOMESTIC HOT WATER

Residential Heating Boilers

HOT WATER SOLUTIONS PRODUCT GUIDE

simply smarter watering technology

Solar Heat Pumps Domestic Range

Bosch Product Reference Guide. bosch-climate.co.nz

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

Hot Water. Experience Our Innovation

HOT WATER. decisions guide

Hot Water Solutions. Click here to Enter

Continuous Flow Hot Water

FASTflo. Working towards a cleaner future

PRODUCT SPECIFICATION GUIDE

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

maximise the sun s energy with warmflow solar Warmflow Solar

Multipoint Technical Data

Operation / Installation Manual

Apricus Solar Hot Water Owner s Operating and Maintenance Manual For Electric Hot Water Tanks (Solar-Ready)

INDIRECT SYSTEM FOR FROST LOCATIONS

Hot Water. Experience Our Innovation

This manual must be kept with the appliance

Rheem Guide to Solar Hot Water

RHEEM DOMESTIC HOT WATER

Technical data LA 60TUR+

GHP AWO 38 Technical overview

The Offer. Hot Water Solutions Offered in - Natural Gas - Electric - LPG

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

RHEEM DOMESTIC HOT WATER

Apricus Solar Hot Water Systems

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

Robert Bosch (Australia) Pty. Ltd.

Saving energy comes naturally to us.

Apricus Solar Hot Water Owner s Operating and Maintenance Manual For Domestic Hot Water Systems

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

installation & operating instructions

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

COMMERCIAL SOLAR SOLUTIONS

Hot Water. Experience Our Innovation

Owner s Guide and Installation Instructions

SOLAR WATER HEATING DIRECT SYSTEM FOR FROST-FREE LOCATIONS DOMESTIC SOLAR WATER HEATERS, SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES

High temperature hydrobox for VRV

Installer s Guide IMPORTANT INFORMATION Read This Document First On completion, sign and leave with owner

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

New Zealand Sales Hotline: Sales Fax:

The Offer. Hot Water Solutions Offered in - Natural Gas - Electric - LPG

HEAT RECOVERY SOLUTION.

Technology and design with Comfort and Energy Saving in mind. Instantaneous Gas Water Heater Series

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Efficient heating that won t cost the earth

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

WATER HEATER RANGE Handicard

Installation/Operating Instructions. MODELS Bosch 17e Bosch 21e Bosch 25e Bosch 26e INSTALLATION MANUAL

Version 1.0. Plumbers Handbook. Scan code for details & installation instructions

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

Hot Water South Australia

Infinity. Continuous Flow Hot Water

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

Lifestyle Electric Thermal Radiator

Lifestyle Electric Thermal Radiator

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

Operation Installation Manual Rinnai Split Solar Hot Water Systems

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

Inverter Hot Water Heat Pumps

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS

COMMERCIAL & INDUSTRIAL

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

Super high efficiency heating and hot water boilers for every type of home and commercial property.

CORRIGENDUM No.l to the Tender Dossier. Reconstruction of Judicial Academy Building in Belgrade Location - Republic of Serbia

unistor High performance unvented stainless steel cylinder range

Operation & Installation Manual

IT S NOT JUST SOLAR IT S SOLAHART

SOLAR HEATING SYSTEMS

Transcription:

HOT WATER SYSTEMS www.thermann.com.au

GAS STORAGE HOT WATER SYSTEM The Thermann 4* Gas hot water heater can suit any family type. With an adjustable thermostat for safety and efficiency it allows you to be in control of your operating costs and performance. The unit has a small footprint which makes it ideal for replacing a 3* changeover. 502 422 340 120 162 HOT WATER OUTLET PTR SOCKET ON RIGHT HAND SIDE A COLD WATER INLET ACCESS COVER B GAS ENTRY HOLE C D 220 Gas Tank 475 Measurements 135L 170L 135L 170L Capacity (litres) 135 170 No. People 3-4 4-5 Net Weight Empty (kg) 72 86 Relief Valve Pressure (kpa) 1400 1400 Gas Consumption (MJ/h) 135NG = 29.5 170NG = 33.5 135LPG = 28 Recovery rate @ 45 o C rise (L/hr) 130 146 First Hr Delivery 265 316 Dimensions (mm) 135L 170L Height (A) 1600 1900 Hot Water Outlet (B) 1325 1620 Cold Water Inlet (C) 220 220 Gas Inlet (D) 300 300 Water Inlet/Outlet Left Left 7YEAR Cylinder 1YEAR Parts and labour Specifications correct for gas storage models manufactured after 1 August 2016. 2

ELECTRIC LARGE HOT WATER SYSTEM THERMANN Electric Storage hot water units are an insulated storage vessel efficiently storing hot water, ready for use, when you need it. The Thermann range of electric water heaters offer solutions in Eight different sizes to suit your needs. B 25 K A C Electric Tank Measurements 80L 125L 160L 250L 315L 400L D E 80L 125L 160L Total Height (A) 925 1090 1315 1445 1745 1705 Total Diameter (B) 490 530 530 615 615 705 Outlet Height (C) 735 865 1120 1211 1531 1445 Inlet Height (D) 160 190 190 195 195 220 Electrical Entry (E) 85 100 100 105 105 130 Element Angle (K) 55 o 55 o 55 o 72 o 72 o 72 o Storage Capacity 88 130 161 259 321 415 Hot Water Delivery 80 125 160 250 315 400 Net Weight Empty 41 51 61 72 92 110 Element Sizes (kw) 3.6 1.8, 3.6 2.4, 3.6 3.6 3.6 3.6 Relief Valve Pressure (kpa) 1000 1000 1000 1000 1000 1000 Max Inlet Pressure Inlet/Outlet No. People (continuous) No. People (off peak) Inlet/Outlet No. People (continuous) No. People (off peak) 2-3 3-4 3-5 0 0 1-3 250L 315L 400L 3-5 4-6 5-9 1-3 2-4 4-6 Without an ECV (kpa) 800 800 800 800 800 800 With an ECV (kpa) 650 650 650 650 650 650 7YEAR Cylinder 1YEAR Parts and labour 3

ELECTRIC SMALL HOT WATER SYSTEM THERMANN small Electric Storage hot water units allow you to install Hot water where space and access is restrictive. With its V fit configuration, inlets and outlets are configured for ease of installation. Available in appliance white for a more AESTHETICALLY pleasing unit. Electric Tank Measurements 25L 50L 25L 50L Total Height (A) 455 695 Total Diameter (B) 405 405 Outlet Height (C) 280 520 Inlet Height (D) 155 155 Electrical Entry (E) 65 65 Element Angle (K) 55 55 Storage Capacity (litres) 31 53 Hot Water Delivery (litres) 25 50 Net Weight Empty (kg) 17 23 Inlet/Outlet No. People (continuous) No. People (off peak) 7YEAR 1YEAR 1 1-2 0 0 Element Size (kw) 2.4*, 3.6 2.4*, 3.6 Relief Valve Pressure (kpa) 1000 1000 Max Inlet Pressure Without an ECV (kpa) 800 800 With an ECV (kpa) 650 650 Cylinder Parts and labour *2.4kW plug in only 4

CONTINUOUS FLOW 5* HOT WATER SYSTEMS The Thermann 5* Gas Continuous Flow system heats water as it flows through a coiled pipe around a gas burner, which means you ll never run out of hot water. 350 350 8.812 165 165 15 15 13 13 50 50 50 50 623 619 575 575 8 8 35 31 585 585 25 25 CABLE ENTRY POINT HOT WATER OUTLET 60 84 84 330 68 198 65 71 COLD WATER INLET WATER INLET FILTER GAS SUPPLY INLET PRESSURE RELIEF VALVE Kitchen Controller (optional) Recess Box Painted (optional) Bathroom/Ensuite Controller (optional) Continuous Flow 5* 278 Measurements 16L 20L 26L Nominal hourly gas consumption (MJ/h) 125 160 200 Test point pressure NG (kpa) 0.4 0.56 0.68 Test point pressure LPG (kpa) 0.4 0.61 0.7 Minimum water pressure (kpa) 260 260 210 Maximum water pressure (kpa) 1200 1200 1200 Minimum gas inlet pressure (kpa) NG 1.13 LPG 2.75 Maximum gas inlet pressure (kpa) NG 5.0 LPG 7.0 NG 1.13 LPG 2.75 NG 5.0 LPG 7.0 NG 1.13 LPG 2.75 NG 5.0 LPG 7.0 Minimum Flow Rate Ignition (l/min) 2.7 2.7 2.7 Input voltage single phase 50Hz (v) 240 240 240 Maximum output current (A) 0.42 0.45 0.47 Inlet gas connection male thread R3/4" (20mm) R3/4 (20mm) R3/4 (20mm) Cold water connection male thread R1/2" (15mm) R1/2" (15mm) R3/4" (20mm) Hot water connection male thread R1/2" (15mm) R1/2" (15mm) R3/4" (20mm) Optional Accessories Code Kitchen controller with 15m cable 9504157 Bathroom controller with 15m cable 9504158 Ensuite controller with 15m cable 9504159 Recess Box Gal 9504553 Recess Box Painted 9504555 Locking Bracket 9504554 16L 20L 26L No. Bathrooms 1 1-2 2-3 Energy Rating (Stars) 5.2 5.3 5.8 Capacity @ 25 rise (L/min) Capacity @ 40 rise (L/min) 16L 20L 26L 10 12.5 16.25 Gas Type Available NG, LPG NG, LPG NG, LPG Relief valve pressure setting (kpa) 1400 1400 1400 Weight dry (kg) 16 16 17 Dimensions (HxWxDmm) 575x350x165 575x350x165 575x350x165 10 YEAR 3YEAR SAIG Approval certificate no. GSCS20021. Watermark Certificate of compliance WMKA 00506 Heat Exchanger Parts and labour 5

CONTINUOUS FLOW 6* HOT WATER SYSTEMS The THERMANN 6*, energy efficient Gas Continuous Flow unit ensures you will HAVE enough hot water, when you need it. With a 12 year warranty, you can rest assured you are covered for the life of the unit, and universal controllers ensure you always have precise control of your hot water temperature settings. 584mm 39mm 520mm 25mm 68mm 68mm 584mm 39mm 520mm 25mm 350mm 12mm 68mm350mm 68mm 68mm 68mm 68mm 68mm 200mm 12mm 15mm 200mm 546mm 12mm 15mm 546mm 12mm Recess Box Painted (optional) COLD WATER INLET R3/4 /20 POWER CABLE ENTRY Continuous Flow 6* PRESSURE RELIEF VALVE HOT WATER OUTLET R3/4 /20 100mm 80mm 69mm 46mm 174mm 260mm 334mm REMOTE CONTROLLER CABLE ENTRY WATER INLET FILTER GAS SUPPLY INLET R3/4 /20 Universal Controller (optional) Measurements 16L 20L 26L Optional Accessories Code 6 Nominal hourly gas consumption by proportional electronic gas control (MJ/h) 125 158 200 Test point pressure (Natural Gas) (kpa) 0.56 0.8 0.8 Test point pressure (Propane) (kpa) 0.91 1.4 1.5 Minimum water pressure (kpa) 60 90 110 Maximum water pressure (kpa) 1200 1200 1200 Minimum gas inlet pressure (kpa) NG 1.13 LPG 2.75 Maximum gas inlet pressure (kpa) NG 5.0 LPG 7.0 NG 1.13 LPG 2.75 NG 5.0 LPG 7.0 NG 1.13 LPG 2.75 NG 5.0 LPG 7.0 Minimum Flow Rate Ignition (l/min) 2.7 2.7 2.7 Input voltage single phase 50Hz (V) 240 240 240 Maximum output current (A) 0.39 0.45 0.46 Inlet gas connection male thread R3/4" (20mm) R3/4" (20mm) R3/4" (20mm) Cold water connection male thread R3/4" (20mm) R3/4" (20mm) R3/4" (20mm) Hot water connection male thread R3/4" (20mm) R3/4" (20mm) R3/4" (20mm) Relief valve pressure setting (kpa) 1400 1400 1400 Weight dry (kg) 15 15 16 Dimensions (HxWxDmm) 520x350x200 520x350x200 520x350x200 IAPMO Approval certificate no. GMK10409. Watermark Certificate of compliance WM-000506 Universal controller with 15m cable 9505082 6* Recess Box Painted 9505219 6* Recess Box Gal 9505218 6* Locking Bracket 9504679 6* Flue Diverter 9505161 16L 20L 26L No. Bathrooms 1 1-2 2-3 Energy Rating (Stars) (50 C) Energy Rating (Stars) (60 C) Capacity @ 25 rise (L/min) Capacity @ 40 rise (L/min) 6.3 6.5 6.1 6.0 6.0 6.0 16L 20L 26L 10 12.5 16.25 Gas Type Available NG, LPG NG, LPG NG, LPG 12 YEAR Heat Exchanger 3YEAR Parts and labour

EVACUATED TUBE SOLAR ELECTRIC BOOSTED Thermann Evacuated Tube Solar electric boosted systems harness the sun s energy to heat your water. An electric element in the tank provides back up if needed, ensuring peace of mind, whilst also reducing your running costs. A A HW OUTLET PTRV B TOP SENSOR B SOLAR RETURN BOTTOM SENSOR INLET FLOW Electric Boosted Tank Measurements (mm) 250L BOT 315L BOT 315L MID 400L BOT 400L MID 250L 315L 400L Tank Diameter (A) 617 617 617 705 705 Tank Height (B) 1445 1765 1765 1704 1704 HW Outlet 1211 1531 1531 1445 1445 PTRV Port 1211 1531 1531 1445 1445 Top Sensor Port 786 872 872 809 832 Solar Return Port 567 566 504 536 554 Bottom Sensor 347 355 326 340 357 Solar Flow 197 197 197 219 219 No. People 3-5 4-6 5-9 No. Tubes 22 30 44 *Other kit configurations available 15 YEAR Tubes 10 YEAR Tank 1YEAR Parts and Labour Cold Water Inlet 197 197 197 219 219 Dry Weight (kg) 71 92 92 116 116 Roof Collector Measurements (mm) Dry Weight Collector Width (A) Length (B) WO/Tubes W/Tubes 22 Tubes 1636 2005 20kg 80.7kg 30 Tubes 2196 2005 24kg 105.7kg Dry weights based on 2 track flush mount frame. 7

EVACUATED TUBE SOLAR GAS BOOSTED Thermann Evacuated Tube Solar gas boosted systems offer reliability and efficiency. Passive sun tracking means more of the sun s rays are converted to usable hot water throughout the day - reducing your power bills. with the gas boosted continuous flow unit, you ll never run out of hot water, no matter the weather. A A B HW Outlet PTRV Top Sensor 13 350 5050 8.8 165 15 8 B Solar Return Bottom Sensor 619 575 585 Flow Inlet 31 25 84 Gas Boosted Tank Measurements (mm) 250L GAS 315L GAS 400L GAS Tank Diameter (A) 617 617 705 Tank Height (B) 1445 1765 1704 HW Outlet 1211 1531 1445 PTRV Port 1211 1531 1445 160L 250L 315L 400L No. People 1-2 3-5 4-6 5-9 No. Tubes 22 22 30 44 Gas Booster 26L 26L 26L 26L Top Sensor Port 992 1258 1208 Solar Return Port 764 953 932 Bottom Sensor 457 551 554 15 YEAR 10 YEAR 1YEAR Solar Flow 197 197 219 Cold Water Inlet 197 197 219 Tubes Tank Parts and Labour Dry Weight (kg) 71 92 116 For 26L Gas Continuous Flow specifications and warranty information refer to page 6. Roof Collector Measurements (mm) Dry Weight Collector Width (A) Length (B) WO/Tubes W/Tubes 22 Tubes 1636 2005 20kg 80.7kg 30 Tubes 2196 2005 24kg 105.7kg Dry weights based on 2 track flush mount frame. 8

EVACUATED TUBE SOLAR HOW IT WORKS Step 1 The sunlight strikes the dark absorber coating inside the tube. Step 2 The heat pipe transfers the heat up to the copper header pipe location in the insulated manifold box. Step 3 A circulator moves water from the storage tank to the copper pipe warming the water. The solar heated water is then pushed down into the storage tank for use. Anti-frost is built in to the Thermann system to ensure solar hot water can be provided even in cold regions. Evacuated tube absorbs sunlight and converts to usable heat Vapour rises to top Heat Transfer Condensed liquid returns to bottom Absorber Coating Vacuum Space PASSIVE SUN TRACKING The round tube design of the system passively tracks the sun throughout the day giving the highest possible performance from early morning through to late afternoon. Afternoon Midday Morning ELECTRIC & GAS SETUPS Electric Booster Gas Booster Thermann Solar Collector Thermann Solar Collector Solar Flow Pump Station Solar Return Storage Tank Hot water to house Solar Flow Pump Station Solar Return Storage Tank Gas Booster Hot water to house Cold Inlet Cold Inlet Note: Diagram not to scale - basic system overview (not installation guide). Note: Diagram not to scale - basic system overview (not installation guide). 9

HEAT PUMP HOT WATER SYSTEM Made in Germany, the Thermann Heat Pump extracts heat from ambient air AND QUIETLY TRANSFERS IT to heat water. It comes with a removable intake grill for easy cleaning and servicing where access is limited. 30-60 30-60 30-60 185 1267 185 670 1267 1638 1638 1840 1840 1840 30-60 1638 1840 30 16 12 Heat Pump 30 16 12 30 16 12 30 16 12 670 670 Heat output kw Dimensions Heat output at A15/W15-55 1.7 Capacity (litres) 300 Power consumption kw Relief valve pressure (kpa) 700 Consumption at A15/W15-55 0.5 Expansion control valve setting* (kpa) 550 Sound data db(a) Max Supply Pressure - without an ECV (kpa) 500 Sound pressure level at 1m distance in a free field 56 Max Supply Pressure - with an ECV (kpa) 420 Energy data kwh Minimum water pressure (kpa) 200 Standby energy consumption/24h at 65 C (Air 15 C) 1.14 Dimensions mm Electrical details Fuses Rated voltage Phases Frequency Rated current Max. power consumption * ECV not supplied C 10 A 240V 1/N/PE 50Hz 2.5 A 700W Height of unit when tilted 1990 Height (adjustable feet) 1870-1900 Diameter 670 Weights kg Weight (dry) 125 Weight (wet) 428 Connections mm Condensate drain 20 Water connection RP3/4" (20mm) Values 5YEAR 2YEAR Air flow rate 550 m3/h 10 Cylinder Parts and labour Lower air temperature limit 0 C Upper air temperature limit 42 C

HEAT PUMP HOT WATER SYSTEM HOW IT WORKS 1 4 2 AIR OUT AIR IN (THERMAL ENERGY) HOT WATER OUTLET 3 COLD WATER INLET 1. A fan draws air through an evaporator. Thermal energy within the air is transferred to a liquid refrigerant causing it to change into a gas. 2. The refrigerant gas is then drawn into a compressor which increases the pressure and as a result increases the temperature. 3. A condenser (heat exchanger) then transports the hot gas refrigerant around the outside of the water tank. This heats the water inside the tank and the gaseous refrigerant reverts into a liquid. 4. The pressure of the refrigerant is reduced as it goes through an expansion valve and returns to the evaporator for the process to start again. 11

www.thermann.com.au Reece. Works for you. Call 1800 032 566 or visit www.reece.com.au for your nearest Reece store. Due to limitations in the printing process the colours in this brochure are a guide only. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. The manufacturer/distributor takes no responsibility for printing errors. All products enjoy a product replacement warranty. For full warranty details visit www.reece.com.au/productquality V9 [BROCHURE CODE 2130530]