HRS Hand Rail System 1

Similar documents
TUNNELS BOXES AND CONNECTORS

TUNNELS BOXES AND CONNECTORS

SYSTEMATIC QUALITY. HandRailSystem HRS-LaneLED-GFK

LaneLED INOX48 Handrail Lighting System

Cable tray solutions. For tunnels GUIDE. The global specialist in electrical and digital building infrastructures

ELSTA MOSDORFER- Energy Distribution with Competence

UV Flame Supervision System

WLS-T25 Solar Powered Low Intensity Duty & Stand-by Aviation Obstruction Light

FR-A180 FR-A360. Occupancy detector. Use

Fire protection in tunnels and public buildings

THE TRUE FIRE SURVIVAL CABLE

Flame detector. The QRA4.U is for use with the following types of burner control:

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65

SAFE CABLING SYSTEMS IN TUNNELS UNDER FIRE

The Quality Connection. BETAflam Fire Resistant Safety Cables

Photovoltaic Cables EN H1Z2Z2-K

with control panel Hobs + Hobs The A Z of Gaggenau hobs and hobs with control panels

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

F Operating Manual. ESS0460-H119 PV Module Solar Soaking Chamber

Safety Lighting. Safe also without electricity. Standards SIST EN 1838: 2011 ISO (2007) CIE S 020 (2007)

DNVGL-CP-0398 Edition December 2015

5W LED Energy Saver PIR Bulkhead

Loadstar AC/DC Systems

LUXCOMFO TM LED Flood Light Datasheet

LED NEW FB-SERIES LED NEW-SF FIXTURE LED NEW-SD FLOODLIGHT LED NEW-SD STREET. LED Explosion-proof Platform Light. LED Tri-proof Light

EMERGENCY LIGHT SERIES

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

NERGYTOWER. energytower Leader in style, quality and safety. ground distribution turrets

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

WKE Spelsberg. The name in maintaining electrical integrity.

Flame detector. The QRA4.U is for use with the following types of burner control:

IN-GRADE LIGHTING M9700C LED IN-GRADE LUMINAIRE

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

Dublin airport - Dublin, Ireland

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Promenade LED. Elegant bollard providing light and colour in urban areas

Flame Safeguards LFE10. Building Technologies HVAC Products

(Notices) EUROPEAN COMMISSION

Heat Sensor Cable Alarm Units DT650L / DT950L

Infrared Flame Detectors

Turbimax CUE21 / CUE22

Traction Cable Radox 3 GKW

700 Watt LED GROW LIGHT

HELKAMA. Optical Fibre Cables

QRA10... QRA53... QRA55...

INVESTIGATING BENEFITS EVACUATION AND EMERGENCY LIGHTING SYSTEMS IN TUNNELS BY USING INTELLIGENT. David Zamora, MariMils, Finland VP Marketing & Sales

Optical benefits associated with PrismaLED technology. Enhanced Lumen Maintenance due to self cleaning design.

Fire protection of emergency electrical devices: effect on the level of risk a case study of a rail tunnel

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

OPERATING MANUAL UNIT 8 - WHITEBRIDGE INDUSTRIAL ESTATE STONE STAFFORDSHIRE ST15 8LQ ENGLAND TEL: +44 (0) FAX: +44 (0)

110 lm w STANDARD SERIES

Here Comes the Sun!!!

60W Multi PIR Bulkhead

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

SAFETY, INSTALLATION AND MAINTENANCE INSTRUCTIONS

Avenue Metro. The evolution of an icon. UK Head Office Whitecroft Lighting Ltd Burlington Street Ashton-Under-Lyne Lancashire OL7 0AX

Kickspot Self-testing/AutoDiag self-contained emergency lighting unit

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

Equipment Information

AlarmLine Linear Heat Detector

Distributed by ECO LIGHT PRODUCT OVERVIEW. Hazardous Area Luminaires

for all applications Fire-rated LED downlights High performance fire-rated LED downlights

Conformity Approvals Rated insulation voltage Ui

Unvented Electric Water Heater 10/15 litre Undersink

User Manual 120/240/300 Outdoor Motion Detector

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

LAE10 LFE10. Use. Series 02

NPS/003/030 Technical Specification for Transformer and Switchgear Cable Boxes and their associated Bushing Assemblies

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

Technologies POWER SAVED IS POWER GENERATED LED STREET LIGHTS OUR PRODUCT

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate

Product Information Motor and machine protection

Infrared Flame Detectors

Maxim3 TM Series IP66. LED Vapor Tight - Waterproof Key Features

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

Making Perfect Sense Of Safety

TubeLine LED unit Optimised comfort with a linear LED solution

ABLOY DOOR CLOSERS Excatly the right choice

Explosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1

GOBLET. Urban Lighting Luminaire. Registered models - Design Massimo Sacconi

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue

RIVERA P5000. Folding awning P5000

Transportation. Distribution

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

High Lux Performance White LED MR16 Lamp

Flame detector. Building Technologies Division Infrastructure & Cities Sector

18W Round LED Wall/Ceiling Light with Microwave Sensor

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards.

Wet alarm valve stations

VECTOTHOR FLYING INSECT CONTROL LIGHT TRAPS

LP CITÉ. By Julie Richoz

Stego accessories for cabinets

PRECISION LIGHTING FOR PRISTINE MOMENTS!

Hotplate/stirrers. Hotplate stirrers

Transcription:

HRS Hand Rail System 1

Safety in tunnels Hand rail system for rail tunnels In accordance with the requirements of the TSI (technical specification for interoperability), all tunnels in the trans-european high-speed rail system with a length exceeding 500 m must be equipped with a hand rail for self-rescue. Installed within easy reach, it helps lead the passengers safely to the emergency exits in the event that an evacuation is necessary. Offering a firm hold and guidance, it is required as a self-rescue aid. For the first time, the Hand Rail System offers operators and planners the use of a product tested as a complete system to fulfil all technical requirements of the TSI. Since all system components are optimised for mutual compatibility, material and installation costs are minimised and trouble-free routine operation is ensured. Hand rail with tube luminaire 2

The first hand rail system tested as a system Hand rail systems consist of various components such as the power supply, lighting and alarm unit. These components must be tested as a system to ensure that they function reliably and safely in the event of a fire. The Hand Rail System is the first hand rail solution in which the modular components were successfully tested together in fire tests according to DIN 4102 Part 12. The fire tests were performed according to the so-called standard fire curve, which is based on real-life temperature profiles from fires. The numerous complex tests that satisfy the high demands of DIN 4102 Part 12 are verified by test certificates from the materials testing institute MPA in Dresden. Fire test facility at MPA Dresden Tested as a system 1.200 1.000 842 C 945 C 1.006 C 800 600 400 200 Temperature profile over the duration of a fire according to standard fire curve, ISO 834, ÖNORM EN 1363, ÖNORM 1365 and DIN 4102 0 0 15 30 45 60 75 90 3

Hand rail with spotlight Mains adapter with WKE 54 Alarm unit Hand rail with LaneLED Tube luminaire 4

System components Power supply Safety begins here. The system can only function if the power supply continues to reach critical equipment during an emergency. The HRS power cable NHXH FE180/E30-E90 with 0.6/1 kv is halogen- and silicone-free and also conforms with the RoHS directive. It also fulfils requirements for protection against rodents. In contrast to conventional chemically cross-linked safety cables, the NHXH FE180/E30-E90 is electron-beam cross-linked, resulting in the following benefits: Higher resistance to heat and pressure, increased tensile strength Safety in the event of short-circuit due to higher thermal and dimensional stability Increased chemical resistance Resistant against soldering irons High impact and crack resistance, especially at low temperatures Good abrasion and weathering resistance Key technical data: Rated voltage U0/U 0,6 / 1 kv Test voltage 3.5 kv at 50 Hz Permissible temperatures Operating temp. from -25 C to +90 C Installation temp. from -5 C to +70 C Short-circuit temperature +250 C Lighting Various lighting options complete the HRS system. The modular system makes it easy to prepare an appropriate lighting design. HRS LaneLED light strip for the HRS MC 30 hand rail: Made of pressed aluminium profile approx. 30 x 25 x 2,900 mm The 3 m segments are equipped with strain relief and protection against false wiring HRS Travalux S tube luminaire for installation below the hand rail: Tube luminaire for tunnel illumination, withstands the demanding conditions in such structures HRS LP42 individual luminaires for installation below the hand rail: Economical single-light solution that also satisfies the requirements for use in tunnels Hand rail HRS hand rail for support and guidance of people in tunnels, also serves as a cable duct Maximum separation of attachment points 1.7 m High thermal stability (-80 C to +130 C) High mechanical strength and chemical resistance High impact and corrosion resistance Non-conducting Halogen-free Low weight and thermal conductivity Easy to work, burr-free Exceptionally long service life Flame-retardant and self-extinguishing No electrolytic corrosion No earthing required Equipment Branch with maintained electrical function, HRS WKE 54. Cable junction box with IP66/67, certified according to EN 60670, with maintained electrical function E30 - E90 according to DIN 4102 Part 12. Halogen-free housing made from special duroplastic Double terminals made from high-temperature-resistant special ceramic Fittings depending on electrical requirements Double terminals 6² to 16² Thermal fuse for the branch D0 fuse for the branch IP66/67 cable gland up to M40 with strain relief HRS alarm unit to support the self-rescue system. In an emergency, the safety lighting can be switched on via the alarm unit. Pressure-resistant button (>9000 N/m2), backlit, avoids activation due to air blast LED ALARM ACTIVATED indicator lamp to confirm alarm activation in an emergency LED orientation lamp, constantly illuminated Power supply for tunnel illumination in emergencies 5

Hand rail in GFK with spotlight The spotlight mounted beneath the hand rail ensures a specified light intensity in lux. In addition, it provides sufficient illumination for maintenance work in its section. The hand railing also provides enough space for the installation of electrical cables and can be retrofitted later. Hand rail with tube luminaire Example systems The tube luminaire can be delivered in different lengths appropriate to the given lighting requirements, which can have a positive influence on installation and maintenance costs. With its integrated reflector, the luminaire can be adjusted as needed. Hand rail with LED light strip This system uses the latest in LED lighting technology in its LED strip configuration. The arrangement of the LEDs ensures uniform illumination of the path. The lamps are protected from external influences by a high-quality cast resin filling. The LaneLED is clicked into place in the hand rail, so except for the main cable and branches, no additional installations are needed. 6

7