User Guide ems25plus. Page 1. Normal operation. Product interface

Similar documents
User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Dixell Installing and Operating Instructions release 7.0

QD-ENG-68 Controller for Thermoelectric Thermal Management

Follett Performance Plus

The Information Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will

SERVICE MANUAL REFRIGERATED AIR DRYER DIGI-PRO CONTROLLER WARRANTY NOTICE

MODEL URS-1: FACTORY RETROFIT PROGRAM

Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

Label Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature

SERVICE MANUAL REFRIGERATION

URS-1 SERVICE AND PARTS MANUAL SERIAL NUMBERS: UP TO

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

Refrigerated air dryers

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

XWA11V. Walk-In Temp / Door /Alarm / Light Module

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

Spas with 2 or 3 Pumps

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

Owner s Manual. Walk-in Monitoring System 100B. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies

Q-Logic Digital Controls The Q3 and Qht for Direct Expansion Systems

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module

INSTRUCTIONS OPERATING BLUETOOTH CAPACITIVE TOUCH THERMOSTAT MODEL COOL/FURNACE COOL/FURNACE/HEAT PUMP

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Siemens RDY2000BN. Start Up Guide

CONTROL PANEL INSTRUCTIONS RSQ-4

XC1008D -XC1011D- XC1015D and VGC810

3. OPERATING INSTRUCTIONS & INSTALLATION

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

Bottom Mount Refrigerator---Technical Information

Product Manual SZ1144

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0

Accent User. Version. Rheem. PO Box 146, ABN:

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

OPERATING INSTRUCTIONS. G214 Software - Version 4

AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION

Thermometers and temperature controllers

REACH-IN SAFETEMP (-AAC)

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

Controlled Thaw Cabinets

8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u

Flash Temp Setting In the state of temp setting - Ready to refrigerate, in the state of compressor start delay protection

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

KELVINATOR C O M M E R C I A L COMMERCIAL FREEZER/REFRIGERATOR REACH-IN REFRIGERATOR AND FREEZER. Refrigerator Model: KCBM23R, KCBM48R, KCBM72R

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

Touch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

MR3CCUHV Temperature/Defrost Control

Fast Track Troubleshooting

OPERATING INSTRUCTIONS

SLV CONTROLLER 105N46XX SERIES

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

Installation and Operation Manual

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

PL-1 Thermostat User s Guide

CAREL IR33+ CONTROLLER

T14 AS1 T20 T40 T24. ISO 9001 Cert. N 0412/2 SERVICE MANUAL. Cod /0-03/ Rev. 000

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Operating instructions Page 12

Prodigy Plus - D Series Cuber Technical Review

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

MANUAL. Type ETO2 Controller for ice and snow melting. Warmup Inc. The world s best-selling electric floor heating brand

Contents. FX-1 Operations Manual Micro Air Corporation 124 Route 526 Allentown, NJ 08501

Digital regulator for refrigeration and defrosting, 3 relays.

CAUTION. No-Load Performance, Controls in Normal Position

COMMERCIAL REFRIGERATOR & FREEZER SERVICE MANUAL (SCL/SCLM)

Each reader connected to the Challenger LAN system is programmed as an Arming Station.

2018 thesimple, Inc.

T5 - T14 - T20 - T24 T30 - T40 - T50 AS1 - MT INSTRUCTION MANUAL. Cod /0-I- 12/ Rev. 001

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

i.c³ User Guide For Helmer i.series Ultra-Low Freezers A/A

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

2017 EcoFactor, Inc.

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS)

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

User's Guide. CTS6000 control panel

ReFreeX H426V1 User manual

DIGITAL TEMPERATURE RELAY TR-100

SERVICE MANUAL REFRIGERATION

T5 - T14 - T20 - T24 T30 - T40 - T50 AS1 - MT INSTRUCTION MANUAL. Cod /0-03/ Rev. 002

Application Manual Loop Water Controller

Advanced temperature controller for cold rooms

SERVICE MANUAL REFRIGERATION

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

TFFR01 MANUAL PORTABAL 12/24 VOLTS DC REFRIGERATOR / FREEZER.

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS OPERATING INSTRUCTIONS

Rev Pulse Modulating and Anti- Sweat Control (PMAC II Solo) Installation and Operation Manual

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

ERC2 Control Instructions

Installation and Operation Manual

Installation and User Instructions

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

Transcription:

Page 1 Product interface rmal operation During normal operation, EMS controllers display the information below. Assuming the product temperature is correct when the outlet is open, this means that the EMS controller is working correctly. If an alarm sounds and the EMS controller displays an alarm state, contact your service provider. LED indicators Ready mode displays the word USE or the product temperature. The cooler lights are on. The product is at the optimal serving temperature, for example 4 C. Green Red Red Buttons Compressor The compressor LED is on while the compressor is running (cooling). Saving temperatures disabled If the LED is on, the product remains at the optimal serving temperature. Motion detection The motion LED flashes on detecting motion. If the motion detection LED is continually flashing when there is no activity in front of cooler, you should contact your service provider. Set (Access the menus - Used by service technicians only) Teach (Starts a Teach period) Up (Cancels teach mode & Toggles summer/ winter mode when not in teach mode) Saving mode usually the cooler lights are off and the product temperature is allowed to rise to a predefined temperature. Defrost mode means the EMS controller has stopped the compressor and the evaporator fan is circulating air to prevent the build-up of ice on the evaporator. Door open indicates that cooler door is open. If the door is open for too long an alarm buzzer sounds and the display changes to. Ensure that the door is closed properly. Freeze up protection if the ambient temperature falls too low, for example below 0 C, the EMS controller stops further cooling. If evaporator frozen, ensure appliance sensor is connected properly. Disconnect appliance sensor and ensure display shows PF1. Otherwise, replace the controller. Down (Also cancels alarms) Power up sequence Checks all the display elements are working Displays the firmware version (Example) Summer mode (default setting) indicates that cooler is in summer mode. Summer mode has no effect on the operation of the controller. Winter mode indicates that cooler is in winter mode. Winter/Summer mode is toggled by holding the UP button for 5 seconds. When in winter mode the controller should switch OFF the compressor at SP+OFS (SSP+OFS when in saving mode). Displays the checksum (Example)

Page 2 Menu access Test routine To access the menu: 1. Press and hold Set until PAS is displayed. Press Set four times (x4). Press Up once (x1). Press Down twice (x2). Press Teach twice (x2). 2. Ensure that PS is displayed. Half reset To clear the self-learning matrix and to restart the learning period: 1. Access the menu and press Down to scroll to the Hr menu. 2. Press Set and ensure that PAS is displayed 3. Re-enter the button sequence of the password: Press Set four times (x4). Press Up once (x1). Press Down twice (x2). Press Teach twice (x2). 4. Ensure that the controller reboots. te: Tests depend on EMS type and configuration. The ems25plus may have: The evaporator fan enabled instead of the lights. The lights enabled instead of the evaporator fan. To test the relays, temperature sensors, and motion sensor: 1. Access the menu and press Down once to scroll to the tst menu. 2. Press Set check displays shows 888. 3. Press Set and Teach together to start the relay test (rel). Then: Press Down to test the evaporator fan if enabled. Press Up to test the lights if enabled. Press Set to test the compressor. 4. Press Teach to switch off relays that are on. 5. Press Set and Teach at the same time to test the analogue inputs (AnA). Then: 6. Press Up and then press Set to view the appliance sensor temperature. 7. Press Set and Teach at the same time to test the motion detector (Pir). 8. Press Teach and then wave hand in front of the motion sensor. Check that the displayed number increases. 9. Press Set and Teach at the same time to exit the test mode. The controller then reboots.

Page 3 Parameter set (controller order) Celsius ( C) or Fahrenheit ( F) sets the temperature scale. Set Point temperature in Fahrenheit (SPF) or Celsius (SPC) sets the lower ready mode temperature (cut out temperature). Differential temperature added to SP temperature. Calibration 1 adds an offset to temperatures measured by the appliance sensor. Saving mode set point sets the lower saving mode temperature (cut out temperature). Saving differential is the temperature added to SSP that sets the upper saving mode temperature (cut in temperature). Uninterrupted pull down the compressor runs continually until the set point is reached. Freeze-up protection is the temperature to disable the compressor and enable the evaporator fan to prevent freeze up due to low temperature. Defrost termination temperature defines the temperature to end a defrost cycle. Fan set point (see te) is the temperature that if exceeded results in the evaporator fan running continuously even if the door is opened. Condenser high temperature is the maximum permitted temperature measured in the refrigeration system. On reaching Ht, the controller disables the compressor and activates an alarm. Parameter set (controller order) Compressor rest time is the minimum time between compressor cycles. Delay to standby is the delay in switching to saving mode from the operational mode. Light delay is the delay to switch off the cooler lights after switching to the saving mode. Saving restart is the maximum time allocated to lower the product temperature to the set point temperature from the saving mode. Refrigeration system failure is the maximum continuous runtime of the compressor without reaching the set point temperature (cut out temperature). Defrost interval is the period between the end of a defrost cycle and beginning of the next defrost cycle. Defrost duration is the maximum time of a defrost cycle. Fan cycle on (see te) is the active period of the evaporator fan while the compressor is off. Fan cycle off (see te) is the inactive period of the evaporator fan while the compressor is off. Display stability sets the rate of change of the displayed temperature. Buzzer enable is the option to disable a warning buzzer for alarm conditions. Does not affect door alarms. Buzzer duration for open door alarm conditions. After the buzzer duration, the controller switches off the compressor.

Page 4 Parameter set (controller order) Alarm delay is the maximum time a door can be open before sounding the alarm buzzer. Activity frequency is the minimum number of door openings or motion counts to indicate an active 30 minute period in the self-learning matrix. Sensor enable enables the motion sensor input. Saving temperature disable is the option to maintain the ready mode temperature at all times. Learning period defines 1-day or 7-day learning period. Parameter set (controller order) Display is the option to display the temperature or the word USE. Output Select is the option to use the light relay as a fan relay, or to keep the lights on at all times, or to switch the lights off when the cooler is in saving mode. Winter Offset the value added as an offset to the set point & Saving set point, when the controller is set to winter mode via the UP button. te: Fan parameters will only be viewable if OS is set at 02 Alarms and troubleshooting The EMS controller has several alarms that indicate problems. If an alarm sounds and the EMS controller displays any of the alarms below, contact your service provider. Door open alarm Refrigeration system failure see the Ct parameter for details. If possible, press the Down button to clear the alarm and wait ten minutes before ensuring that the cooler is working. If not, contact your service provider. Condenser high temperature means the temperature sensor on the condenser is reading a high temperature that usually indicates the condenser is blocked. If possible, press the Down button to clear the alarm. Sensor failure indicates that a temperature sensor has failed. PF1 alarms mean that the temperature in the refrigeration compartment has failed. PF2 alarms mean that the temperature sensor reading the condenser temperature has failed. Cooler lights do not switch on If EMS controller is in the ready mode, ensure that the light switch inside the cooler switched on. Check that the lights are connected to EMS using the analogue input test.

Page 5 Motion sensor alarms Motion detection LED flashing continuously Is motion sensor fitted? Check value of the sensor enable (Sn) parameter in the parameter information pack supplied by Elstat Was sensor enable (Sn) = 00 requested? Request an XML change from Elstat with sensor enable (Sn) = 00 motion sensor Check motion sensor circuit Perform the analogue sensor test

Page 6 Condenser high temperature alarms Perform the analogue sensor test Is condenser sensor short circuit? Ensure condenser grill area free from obstructions Reset alarm: press down button on the controller once Has Ht alarm cleared? controller sensor Is the condenser fan running with the compressor? Investigate fan problem Is the Ht value set to correct value for cooler? Manually set Ht to the correct value Fault cleared

Page 7 Temperature sensor alarms Perform the analogue sensor test Are sensors securely fitted? Secure loose sensor Alarm cleared? Fault cleared faulty sensor Is either sensor open circuit? controller

Page 8 Door open alarms Is door switch fitted? Is Ad > 0? EMS Cooler in door open alarm mode and indicates that the door is open and the Ad+b1 has expired Set Ad = 0 EMS Ensure cooler door closed EMS operating as specified Ensure area in front of motion sensor is clear Carry out half factory reset EMS operating as specified See Alarms for further information Apply hand held activator i.e. magnet against the door switch Is the connection between the door switch and EMS good? Remake connection Activator misaligned Realign activator door switch