INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Condensate Return Systems General Installation, Operation, & Service Instructions !

Similar documents
INSTRUCTION MANUAL DN0136 REVISION D

Domestic Pump Vacuum and Boiler Feed Units Series VCMD TM INSTRUCTION MANUAL DN0137 REVISION F

DESCRIPTION AND INSTALLATION

Hoffman Specialty Watchman Series WC & WCS Condensate Units Replacement Parts PART LISTS DN0436C

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

Series 1140 and 1141 Temperature Regulators

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

T-Series Air Conditioner T53 Model

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

LC Series - Light Commercial Pump Station Installation and Operation Manual

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

OPERATING MANUAL. Reverse Osmosis Equipment Model: Frame Mount Vertical FMV-1 through FMV-6. Made in U.S.A.

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

Trouble Shooting Guide FAA, 3-phase (D3631)

BuildingName The Description of the Project P DOCUMENTS

THERMAPHASE INSTALLATION AND OPERATING INSTRUCTIONS

SECTION STEAM CONDENSATE PUMPS

T-Series Air Conditioner T15 Model

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Panel Fan Series Operators Manual (Galvanized and Polymer)

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Condensing Unit Installation and Operating Instructions

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

SECTION STEAM CONDENSATE PUMPS

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

The Da-Lite Difference.

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Installation Instructions

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP

YCIV Hz & Hz

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner ADVANTAGE RP55 SERIES

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

T-Series Air Conditioner T20 Model

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

INSTRUCTION AND REPAIR MANUAL

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

INSTALLATION & OPERATING INSTRUCTIONS FOR CEILING MOUNT AIR HANDLERS AC SERIES

DISPOSER CONTROL CENTER

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

Installation Instructions

OWNERS GUIDE TO INSTALLATION AND OPERATION

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

Series 300 VTB. Installation Instructions

Installation, Operation, and Maintenance Manual

FOOD WASTE DISPOSERS MODELS FD4-150 FD4-200 FD FORM (May 2015) S. RIDGE AVENUE TROY, OHIO

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

Drying Tumblers. Troubleshooting. 120 Pound Capacity 170 Pound Capacity. Refer to Page 5 for Model Numbers. Part No August 2007

CS 2. Central Station Air Handlers Double Wall & Single Wall Installation, Operation & Maintenance Manual. Form No. 6120A

EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST TEL NO: ORDER NO: CONTRACT NO:

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

IMPORTANT INSTRUCTIONS

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start

Installation Instruction

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

Beverage Air IMPORTANT

MODELS R & RH 10 THRU 20 RB SERIES ELECTRIC STEAM BOILERS

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

MODEL YVAA EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: LOCATION: ADDRESS: CUSTOMER ORDER NO: PHONE: JCI CONTRACT NO: JOB NAME:

INSTALLATION & MAINTENANCE MANUAL PVI ELECTRIC HOT WATER SUPPLY BOILER

Trouble Shooting Guide RAA, 1-phase (D3627)

Trouble Shooting Guide PAA, 1-phase (D3731)

INSTRUCTION MANUAL with Replacement Parts

DISPOSER CONTROL CENTER

ENERVEX GSV GREASE FAN

AquaSaver DISPOSER CONTROL CENTER Installation Manual. Model AS-101K

SECTION HEATING BOILER FEEDWATER EQUIPMENT

This label warns for risk of electrical shock when failing to observe.

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

Condensate Return Feedwater Systems For Low and High Pressure Steam Boilers

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

- 1 - Updated on 18 March, 2010

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Condensate Boiler Feed Water Make-Up

Trouble Shooting Guide PWA, 3-phase (D10571)

- 1 - Updated on 18 March, 2010

Contour TM Screw Compressors

INSTALLATION, OPERATION & MAINTENANCE MANUAL WING FRESH AIR SUPPLY UNIT Steam & Hot Water

Panel Fan Series Operators Manual (Galvanized and Polymer)

4600 SERIES. Technical Specifications. Condensate Units - Steel Tank. Features

AXPR Wall Mounted Axial Panel Fans

USERS INFORMATION MANUAL FOR GAS FIRED BOILERS

SHURFLO BLASTER II MARINE WASHDOWN PUMP PRODUCT TECHNICAL DATA SHEET

Transcription:

Condensate Return Systems General Installation, Operation, & Service Instructions INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. SAFETY INSTRUCTIONS This safety alert symbol will be used in this manual and on the unit safety instruction decals to draw attention to safety related instructions. When used, the safety alert symbol means ATTENTION! BECOME ALERT! YOUR SAFETY IS INVOLVED! FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN A SAFETY HAZARD

Typical Installation 1 Vent Overflow 4 inlet DESCRIPTION Pumps are float operated to return accumulated condensate to a boiler feed tank. EXPLOSIBLE Do not pressurize receiver. Isolate receiver during leak test. Do not plug overflow. Do not restrict vent opening to atmosphere. Open valves slowly. PRELIMINARY INSPECTION Assure that there is no shipping damage. HANDLING Use care in installing unit. LOCATION Place unit for easy access to all parts. Allow adequate space for servicing. Check ambient conditions. NOTICE / TEMPERATURE LIMITS Motors are designed to operate in 104ºF. (40ºC) max. ambient. Insulate or ventilate as required. PIPING (General) Pipe the unit per the Elementary Piping Diagram. Locate and support piping so as to not load the pump discharge. PIPING (Returns) Gravity return lines from system should be properly pitched down to unit inlet. Returns must also be trapped to prevent steam entry into the unit. An inlet basket strainer is recommended. Bypass piping to a drain is recommended per the piping diagram. NOT A CHEM- ICAL PUMP! CAUTION Inject boiler feed compounds from chemical feed tank into boiler feed piping - never into condensate tank. Failure to follow these instructions could result in injury or property damage. PIPING (Vent) Pump Discharge Install a vent pipe to atmosphere. Pipe to be size of vent port on unit. Do not restrict or reduce vent opening or exceed 20 inch vertical height unless an overflow connection is provided. PIPING (Overflow) Pipe overflow port to drain using an overflow loop when condensate temp will exceed 200ºF (93ºC). FLOAT SWITCHES & MECHANI- CAL ALTERNATORS Floats are locked in place to prevent damage during shipment. Remove shipping locks. Check factory settings. Floats and mechanical alternators are adjustable for various levels of operation. Sight Glass Float/Alt. Temp The lead pump should start with tank 3/4 full and shut off at 2 or more above pump inlet. Lag pump should start before the tank overflows. Settings should avoid short cycling of the pump. HIGH VOLT- AGE ELEC- TRICITY Disconnect and lock out power before connecting or servicing unit. Failure to follow these instructions could result in serious injury or death. ELECTRICAL WIRING & CON- TROLS Connect power wiring per NEC. Recheck nameplate vs. specifications and conditions. All single phase motors have internal thermal protection. Three phase motors must use starters with properly sized overload relays. Overload relays furnished are designed for manual reset.

REPRESENTATIVE WIRING DIAGRAMS SIMPLEX UNITS, SINGLE PHASE DUPLEX UNITS, SINGLE PHASE Note: For 3 phase units, see wiring diagram inside control panel furnished with system.

PUTTING THE UNIT INTO SERVICE 1. Assure that the unit is piped in accordance with instructions in this manual. EXPLOSIBLE Do not pressurize receiver. Isolate receiver during leak test. Do not plug overflow. Do not restrict vent opening to atmosphere. Open valves slowly. 2. Isolate tank before performing any system leak test. Do not pressurize the tank as part of the leak test. Failure to do this can result in serious injury or death. HIGH VOLT- AGE Disconnect and lock out power before connecting or servicing unit. 3. Check floats and alternators for free operation. 4. Wire unit per National Electrical Code. See representative wiring diagrams. 5. Install drain plugs if necessary. 6. Fill receiver half full of water to prime pump(s) and prevent possible damage to pump seals. Avoid freezing conditions after unit receiver has been filled. 7. Check for proper rotation of all three phase motors. Rotation must be clockwise looking down on the motor as DO NOT RE- VERSE! CAUTION Reverse operation can cause extensive damage to pumps. Jog the motor to test for direction of rotation. Failure to follow these instructions could result in injury or property damage. DO NOT RUN DRY. SEAL! CAUTION DAMAGE MAY OCCUR. Inspect pump seal regularly for leaks. Replace as required. Failure to follow these instructions could result in injury or property damage. indicated by directional arrow on pump casting. If pump runs backwards, interchange two wires (3 phase only). 8. Assure all shipping locks have been removed from all float switches. 9. If possible, observe operation thru several cycles. OPERATION AND MAINTE- NANCE Operators must be familiar with all sections of this manual to understand the operation of the unit. Hot water, steam and electricity can be hazardous. Check motor nameplate for any lubrication requirements. Pumps require no lubrication. NOTICE / AUTO RESTART Single phase motors will restart automatically after thermal overload protector trips. EXPLOSIBLE Do not pressurize receiver. Isolate receiver during leak test. Do not plug overflow. Do not restrict vent opening to atmosphere. Open valves slowly. HIGH VOLT- AGE ELEC- TRICITY Disconnect and lock out power before connecting or servicing unit. Failure to follow these instructions could result in serious injury or death. Overload thermal relays in starters must be reset manually. A properly installed unit should function unattended for long periods of time. Periodic checks to assure proper operations are highly recommended. Refer to trouble shooting section when necessary. A variety of control options are available and are furnished in accordance with user specifications. Refer to wiring diagrams (when furnished) to determine control switch settings. The inlet strainer (when furnished) is intended to protect the pump and system. Periodic cleaning should be included in the maintenance schedule. Check frequently in new systems. SUBSEQUENT DAMAGE! CAUTION: A unit showing symptoms of possible problems (overflow, noise, leaks, vibrations, continual operation, etc.) must be corrected immediately. may result in full liability for subsequent injury or property damage.

TANK FLOAT SWITCH INSTRUC- TIONS APPLICATION - For automatically controlling the liquid level in a closed tank by float movement. MOUNTING - Screw-in Tank Float Switches are mounted directly to the tank by means of the 21/2 I.P.S. threaded fitting (D). Before screwing this fitting into tank, loosen Nut (C) so that the fitting (D) is free to rotate in the switch bracket. Tighten the fitting (D) so that there will be no leak past the threads. Then revolve the switch case until it is horizontal and tighten Nut (C). MECHANICAL ALTERNATOR INSTRUCTIONS APPLICATION - Mechanical Alternators serve to open and close an electric circuit by an upward and downward float movement. The forces are applied by means of a float operating between different liquid levels. The action is such that two switch units are alternated on successive cycles. If the liquid level continues to rise or fall with one pump in operation, the lever will continue to travel to a further position at which point the second switch will be operated, throwing the stand-by pump across the line. MOUNTING - Mechanical alternators are mounted directly to the tank by means of the 21/2 I.P.S. threaded fitting (D). Before screwing this fitting into tank, loosen Nut (C) so that the fitting (D) is free to rotate in the switch bracket. Tighten the fitting (D) so that there will be no leak past the threads. REVERSE ACTION - To change, relocate operating link to the opposite slot in base plate and corresponding hole in adjusting plate. ADJUSTMENT - Switches are shipped from the factory set for a specified float travel. Reasonable adjustment of float travel can be made in the field by moving adjusting strips (7) which are held in place by Screws (A) and (B). Loosen Screw (B) and moving upper adjusting strip (7) will Then revolve the switch case until it is horizontal and tighten Nut (C). STANDARD OPERATION - Contacts are arranged for sump action. In this form the contacts will close on increase in liquid level. REVERSE ACTION - To change, relocate operating link to the opposite slot in base plate and corresponding hole in adjusting plate. ADJUSTMENT - Switches are shipped from the factory set for a specified float travel. Reasonable adjustment of float travel can be made in the field by moving adjusting strips (7) which are held in place by Screws (A) and (B). Loosen Screw (B) and moving affect the upper limit of float travel only. Loosening Screw (A) and moving lower adjusting strip (7) will affect the lower limit of float travel. CAUTION: Switches are shipped with a bracket attached to the mounting plate. This bracket prevents the float and the rod from moving in the tank during shipment. When installing the system, this clearly marked shipping bracket must be removed and discarded. upper adjusting strip (7) will affect the upper limit of float travel only. Loosening Screw (A) and moving lower adjusting strip (7) will affect the lower limit of float travel. CAUTION: Switches are shipped with a bracket attached to the mounting plate. This bracket prevents the float and the rod from moving in the tank during shipment. When installing the system, this clearly marked shipping bracket must be removed and discarded.

SEE C4, C5, & C6 Instruction Manuals for Centrifugal Pump Details TROUBLE SHOOTING PROCEDURE All units are thoroughly tested at the factory before shipment. They should operate satisfactorily without further adjustment if properly installed and providing they have not been damaged by rough handling in transit. If system or unit performance is not satisfactory, refer to the following check list. Pump Will Not Start 1. The power supply has been interrupted, disconnect switch is open, or selector switch is improperly positioned. 2. Incorrect voltage for motor. Check voltage and wiring with motor characteristics. 3. Incorrect starter coil for power supply. 4. The overload relays and the starter have tripped out and must be reset. Ambient temperature may be too high. 5. Check pump controls or other controls for proper operation. 6. Wiring to control cabinet is incorrect or connections are loose. 7. The strainer is dirty thus retarding flow. Clean periodically. Pump Runs Continuously 1. Pump is running backward. Rotation of three phase motors may be corrected by interchanging any two of the three wires. Rotation should be clockwise looking down on motor. 2. Steam traps are blowing through causing condensate to return at excessive temperatures. This may reduce the capacity of pump below its rating, depending on the unit and type of pump furnished. Traps should be repaired or replaced. 3. The total required pressure at the pump discharge is greater than the pressure for which the pump was designed. Check the total pressure which includes atmospheric pressure, the friction head and the static head. 4. A valve in the discharge line is closed or throttled too tightly. Check valve is installed backwards. 5. The impeller eye is clogged. 6. Pump is too small for system. Condensate Pump is Noisy 1. Excessive condensate temperature. Correct system conditions. 2. Magnetic hum or bearing noise in motor. Consult motor manufacturer s authorized service station nearest unit location. 3. Starter chatters. Trouble is caused by low line voltage, poor connections, defective starter coil, or burned contacts. 4. Pump is running backward. The System is Noisy 1. Banging in steam mains is usually caused by steam imploding in condensate lying in low points in lines. These problems can be eliminated by dripping low points, properly supporting the pipe, or by increasing th pitch of the lines. 2. Improper dripping of the steam mains and risers; where there is a rise in the steam main, or where it branches off into a riser, a drip trap must be installed in the drain line. 3. The piping is too small to drain properly. 4. A defective trap is holding condensate in steam supply line.