COOLING. 4/05/04 Std.

Similar documents
Part IV: Flow Side Components Flow Diagram

OWNER S GUIDE SEQUENTIAL THERMOSTATIC SHOWER VALVE. 150mm Inlet Pipe Centres. Shower Control. Handles and. may differ depending.

RQE Series Temperature Controllers

The Experts in Vacuum Solutions

SYNRAD Technical Bulletin # 0015d

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Rev B, 9/2/2009. Kodiak Chiller Overview

Tel: Fax: Website:

PURGER INSTALLATION AND OPERATION BULLETIN PUR-SB17-02 SERVICE BULLETIN

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

Fans and Pumps I. Dr. Sam C. M. Hui Department of Mechanical Engineering The University of Hong Kong

CVGF. Water Cooled Centrifugal Chillers

Trouble Shooting Guide PWA, 3-phase (D10571)

CHILLER. Operator s & Installation Manual

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

FT900D DUAL RINSE FLIGHT-TYPE DISHWASHER

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

Laird Engineered Thermal Systems Application Note. Liquid to Liquid Ambient Cooling Systems for Semiconductor Tools

... Green Building Details

AUXILIARY EQUIPMENT FOR ALL YOUR NEEDS

Encyclon Inc. Cyclonic Filtration Systems

SINGLE LEVER CERAMIC DISC MANUAL SHOWER VALVE

3. What are the main parts in a compressed air generation? And list the flow path in order? 4. Draw the ISO symbol for an air compressor.

Sanborn Technologies Catalog of Products

(2) 325 tpd York Chlorine Liquefier Systems

AHRI Certification Program Scopes - COOLING

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

Customer Requirements Pre-Installation Instructions

Water Purification 85

Water Purification. Quality distilled... the most reliable method of purifying water 81

KODIAK RECIRCULATING CHILLERS TECHNICAL MANUAL RC006, RC009, RC011, RC022, RC030 and RC045 G03, H03 and J03 Series

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Dual Control Concealed & Exposed Thermostatic Shower Valve

Circulating Water Temperature Controller

FT900S FLIGHT-TYPE DISHWASHER

DISTILLATION. The Best Distillation Times Two! 4 FI-STREEM Tap/Pretreated 30 Liter Storage Reservoir WP54 50 Liter Storage Reservoir

FT900S FLIGHT-TYPE DISHWASHER

TITAN SYSTEM ENGINEERING DATA SHEET TITAN HXS

Air Dryer Application Guidelines

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

SUNOCO Heat Transfer Fluids

Installation, Operation and Maintenance Manual

Energy-Saving Industrial Water Chillers

ZEROwaste HX PERC SYSTEM USER MANUAL. AIR QUALITY LABORATORIES Seattle, Washington

Plant Growth Chamber MPGR14

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

TRION Air Purification systems

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

PCAH SERIES AIR HANDLER

dualarm Vertical In-Line Pumps

REFRIGERATED AIR DRYERS

Custom Design TYPE CS

PRESSURE INDEPENDENT CONTROL VALVE TECHNOLOGY. 3/16/2012 Fred Ferrara 1

STAINLESS STEEL UNITS

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

12 In Row. Installation Manual. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

CHILLER. Model CH3000. Operator s & Installation Manual

OPERATING MANUAL. Reverse Osmosis Equipment Model: Frame Mount Vertical FMV-1 through FMV-6. Made in U.S.A.

Pumps SELECTION OF A PUMP

FT900 FLIGHT-TYPE DISHWASHER

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

Installation Manual for. Series HWM and Non-ETI HYDRONIC WATER MODULE with SC and SD COMPRESSOR UNITS and R-410 REFRIGERANT

Cool IR. Model C104 - Cooling System. Instruction Manual

America s Most Versatile Line of Centrifugal Pumps

1998 XJ RANGE - Evaporative Emissions

Series 6, Vertical Floor-Mount Units

CPF PRODUCT DESCRIPTION

Coolers / Chillers. Accessories for oil cooled units. Overview. Accessories for water cooled units. Industrial X-Ray

High-Capacity Cycling Refrigerated Compressed Air Dryer. RTM Series

EDS - EDC. Vacuum Insulating Oil Treatment Plants

heat interface units A BOILER WITHOUT A FLAME

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

Midea VFD Centrifugal Chiller Technology

International PCT Patent Application No. PCT/GB2011/ Automag. Self-purging, fully automated magnetic filter

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

SERVICE REQUIREMENTS

Wilo IL Vertical Split-Coupled Inline Pumps

PL PERFORMANCE FIELDS

How to Select and Size a Chiller

WATER COOLER: CW-5200 USER MANUAL

CL64T INDUSTRIAL TOTE WASHER

OPERATION MANUAL OPERATION MANUAL FREE WATER-COOLED HEAT EXCHANGER

A CASE STUDY ON PUMP OF HYDRO PNEUMATIC BOOSTER SYSTEM

TPF Series Ozone Generators

Multiaqua Chiller Manual

Temptek Auxiliary Equipment

Water Pre-Filtration System Installation Instructions Endoscope Reprocessing Systems

Tramp Oil. Removal Equipment Equipment designed for removing oil from water based fluids ERIEZ. ...Only from Eriez. Tramp Oil. Removal Equipment:

White paper Compressed air drying

Refrigeration dryers DW 2-504

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES

Specifications. The Liquid Super Separator is a new concept of air filtration that is totally different from

USER MANUAL/Installation Instructions LRV-4

Chapter-8 Capacity Control of Refrigeration Systems

Tetra Pak Indirect UHT unit PFF with tubular heat exchanger Efficient UHT unit for flexible production of ambient or hot-filled prepared food products

Transcription:

4/05/04 Std.

1.0 GENERAL: The U. S. Laser cooling system is a closed loop primary, open loop secondary, water-to-water heat exchanger. Temperature regulated distilled deionized water is circulated on the laser head (primary) side, while tap or chilled water flows through a stainless steel spiral plate heat exchanger on the secondary side. Primary loop water is pumped by a close-coupled centrifugal pump which has a 3/4 H.P. motor, and a special plastic impeller and volute. In operation, the pump provides 35-50 P.S.I. of deionized water to the laser head assembly at about 4-5 gallons per minute. Unique to the U. S. Laser heat exchanger is a modulating valve temperature regulating scheme, which replaces the thermostat and solenoid valve of other laser coolers. This scheme provides greater thermal stability, and eliminates the inductive power line spikes associated with solenoid opening and closing. The system has a 5 gallon plastic reservoir and is equipped with low level interlocks. Also provided are flow rate and over temperature interlocks. All piping, fittings, and other elements exposed to water on the primary side of the heat exchanger are plastic, stainless steel, or other inert material to maintain the integrity of the deionized water. 2.0 OPERATION: 2.1 SECONDARY LOOP: SECONDARY COOLING WATER REQUIREMENTS LASER MAXIMUM MAXIMUM MINIMUM FLOW HEAT LOAD TEMPERATURE REQUIRED 303, T, 403 C, H, L 5 KW 60 F 3 GAL/MIN 403T, TL, CH 6.5 KW 60 F 4 GAL/MIN 404 7.5 KW 60 F 5 GAL/MIN 405 9 KW 55 F 4 GAL/MIN 406-1 14 KW 55 F 6 GAL/MIN 408-1 18 KW 50 F 6 GAL/MIN COOLING- 1

NOTE: CONSULT FACTORY IF ABOVE WATER REQUIREMENTS CANNOT BE MET. External tap or chiller water is connected to the cooler by the customer via garden hose fittings on the lower rear panel of the power supply/cooler console. Inlet water is fed through the solenoid valve to the secondary side of the spiral plate heat exchanger. Water then flows through the modulating valve to the water return line. Water temperature in the reservoir is sensed by the modulating valve through a sensor in the primary water line to the reservoir. As the temperature in the reservoir changes, it is sensed by the modulating valve, which compensates by opening or closing the valve slightly, thus continuously adjusting the primary water temperature to a fixed preset level. Due to the inherent function of the modulating valve, the inlet water constantly runs at some low rate which is determined by the valve setting, the laser heat load, and the inlet water temperature. To prevent water from running when the system is not in use, a solenoid valve located in the return line is electrically controlled by the Key Switch. When the key is shut off, all water flow ceases. U. S. Laser suggests that an inline particle filter be installed on the inlet water line if the water supply will have significant particulate matter suspended in it. This will prevent potential blockage or jamming of the solenoid valve and/or modulating valve, which can lead to impaired cooling operation. 2.2 PRIMARY LOOP: Water from the reservoir is gravity fed to the pump inlet port. The centrifugal pump then feeds water at 35-50 P.S.I., up to 6 gallons per minute(depending upon laser model), directly to the laser head through semi-rigid polyflo tubing cooling lines which are attached directly to the laser head assembly. This water cools the laser rod and laser lamp, and returns under pressure to the cooler. Attached to the body of an elbow fitting in the water supply line to the laser head are two temperature sensors. One is an over temperature warning; the other is an interlock interrupt which shuts down the laser power supply if the cooling water return temperature exceeds 120 degrees F. The return water from the laser head goes through the inline 5 micron particle filter and then through the flow switch. The flow switch is an electromechanical device which is tied into the main laser protective interlock loop and shuts the laser power supply down if sufficient water flow is not present. After the flow switch, the water is fed through the heat exchanger where it is cooled by the secondary water loop. After the heat COOLING- 2

exchanger, the water flow is split. The main flow path is a direct return to the reservoir through the sensing side of the modulating valve. A smaller flow path is fed to the deionizing filter which removes ionized material in the water in order to maintain its dielectric integrity. The deionized water then returns directly to the reservoir. The plastic reservoir tank is capable of holding 5 gallons of deionized water, and has two built in low level sensors. One sensor warns of low water level, and the other is an interlock which shuts down the laser power supply if the level falls below a critical operating point. 3.0 COOLER MAINTENANCE: 3.1 INITIAL FILLING: As shipped, all water has been removed from the laser system. At installation, after all water connections have been made, the power supply/cooler console side cover should be removed, and the reservoir filled to within 1/2" of the top of the tank with distilled/deionized water. The cooler should then be turned on for about one minute to purge air from the laser head and coolant lines. The cooler should then be turned off, and the reservoir filled again to bring the water up to the proper level. 3.2 FI LTER REP LACEMENT: The laser system cooler is equipped with both a deionizing filter and a particle filter. During normal operation these elements should be changed every six months. The 5 micron particle filter is available from U. S. Laser as Part #3102-1 and the deionizing cartridge Part #3101. Failure to change deionizer and particle filters (they should always be changed together) could severely degrade the cooling water integrity and lead to deterioration of expensive laser head components. If the laser system is to be inactive for a substantial period of time, the cooling system should either be turned on weekly for about one half hour to circulate the water through the deionizer, or the system should be drained and the laser head dried in order to prevent water spotting of the elliptical laser head cavity. COOLING- 3

3.3 TEMPERATURE ADJUSTMENT: The temperature of the primary loop water is preset and fixed at the factory, and no further adjustment should be necessary. The cooling water temperature is normally held to about 20 degrees C for Model 303, 403, 404, and 405 lasers and 26 degrees C for Model 406 and 408 lasers (± 2 degrees). If the system water temperature deviates radically from this level, the proportioning valve may be malfunctioning, and the factory should be consulted for technical assistance. COOLING- 4