UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE

Similar documents
ULTRAMAX GOLD UMX REMOTE LAMP AIR DISINFECTION SYSTEMS w/ ODOR REDUCING TECHNOLOGY (PCO) OWNERS GUIDE

WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS

Ultraviolet Disinfection Unit Installation and Owners Manual

WARNING WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS

Design Manual Installation Operation Maintenance

Ultraviolet Lights on Daikin Applied Rooftop Systems and Rooftop Air Handlers

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

Auto Opening with Pressure Readout 15 x15 & 16 x20 Heat Transfer Machines

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

Model AD30-2. Document No B3 Revised November Atlantic Ultraviolet Corporation

OWNERS MANUAL. Installation. Operation. Specifications. Features. Maintenance. Warranty REV 02_04 FA SP-ENG OM - 02_04

Rainsoft Division of Aquion, Inc East Lunt Avenue Elk Grove Village, Illinois or

Cincinnati, OH USA

Global Water Instrumentation, Inc.

PCO/UV N-Duct Model. Owner s Guide

2 Installation Notes

Cincinnati, OH USA

OPERATION & INSTALLATION MANUAL AIR PURIFICATION SYSTEM (APS300)

TPP440. owner s guide. air purifier with uv light. air purifier with uv light TP

Model CWA200 Owner s Manual

Dayton Electric Infrared Fireplace User Manual

Document No A3 Revised February Atlantic Ultraviolet Corporation

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

OWNERS MANUAL. Installation. Operation. Specifications. Features. Maintenance. Warranty REV 0905 FAOM15_0905

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INFORMATION:

e Bath Fan with Light User s Guide

WIRING DIAGRAM. This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900

BIOZONE ICEZONE OWNER'S MANUAL Single Horizontal Evaporator Style Ice Machines BioZone Scientific International

Owner s Manual LIMITED WARRANTY INFORMATION OBTAINING WARRANTY SERVICE FURTHER LIMITATIONS AND EXCLUSIONS ARE AS FOLLOWS REGISTRATION

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

Introduction... 1 System Overview... 1 System Diagram... 2

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Model TL104 MANTL104. Test Lamp for Flame Detection

DUST FREE CARBON Whole House Air Purifier

Document No B Revised June Atlantic Ultraviolet Corporation

User Manual. 40 Tower Fan MODEL: WFTR40W

Document No B1 February Atlantic Ultraviolet Corporation

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

e Heater/Exhaust Fan/Light User s Guide

150 WATT PORTABLE CLAMP LIGHT 35149

SOLO OWNERS MANUAL, OPERATING INSTRUCTIONS & INSTALLATION INSTRUCTIONS

UV100E Ultraviolet Air Treatment System

Ultra Lightweight Household & Commercial Vacuums

INSTALLATION AND OPERATION INSTRUCTIONS

BioZone Scientific International contact information

Digital Heat Block User Manual

InstructIon Manual KrEs EQuIPMEnt stands

PRACTICAL USER S GUIDE FOR THE DIMPLEX PURIFIRE ELECTRIC STOVE

ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

User Manual / Installation Instructions

HAMILTON ELECTRIC STOVE HEATER MODEL EF-BLT01 / EF-BLT04 / EF-BLT07 / EF-BLT08 OPERATION MANUAL

Soldering Station INSTRUCTION MANUAL

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

PRACTICAL USER S GUIDE FOR THE contempra ef STOVE

PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE

e Bath Fan with Light User s Guide

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Electric Fireplace Instruction Manual

IMPORTANT SAFETY INFORMATION:

CABINET INFRARED HEATER

D-TEK Select. Refrigerant Leak Detector

INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM


WARNING Important Safety Information

HGW-308R Wall Mountable Micathermic Heater w/ Remote. Model No. HGW-308R Soleus Air International

Service Manual Model 3163

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

OWNER S MANUAL

HC Ceramic Tower Heater Operating Instructions HC Soleus Air International

e Bath Fan with Light User s Guide

BIOZONE ICEZONE OWNER'S MANUAL Closely Spaced Evaporator Style Ice Machines BioZone Scientific International

IMPORTANT SAFETY INSTRUCTIONS

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

User Manual. Wine Cellar

Operating Instructions

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

Each heater has slightly different operational characteristics

Integrated Ventilation System

60In. Ceiling Fan. Owner s Manual

MODEL NO: WD Warming Drawer, Rated 120V, 60 Hz,450W, 4A. Certificate Project Figure No. Version A

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

WARNING Important Safety Information

D2E Duct Smoke Detector

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

Owner s Manual & Safety Instructions

Riverside. Made In Viet Nam. Addison #65448 & Richland #65748 & Left & Right Pier Assembly Instructions

1020 Industrial Drive, Orlinda, TN fax

EFT-3002 PORTABLE EMBRYO FREEZER INSTRUCTION MANUAL MANUFACTURED BY. BELTRON Instruments

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

HT-600D. (either domestic or foreign), please keep a copy of their sales invoice showing the serial

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

Easy-Lam School Budget Roll Laminator

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

Transcription:

UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE Models: UVS- 1200T, 1900T, 1202T, 1902T Models: UVE- 1200T, 1900T, 1202T, 1902T Table of Contents: Page 2- Shipping and Packing List, Safety Precautions Page 3-Installation Steps for remote s Page 4- Maintenance, Trouble Shooting Page 5- Parts Description Page 6- Replacement Parts, Warranty DC-IH-0214 LEAVE FOR HOMEOWNER

Shipping and Packaging List: UVS or UVE Electrical Housing 6- ¾ inch 5/16 self tapping sheet metal screws Warning Label Residential Warranty Card UVS- 1200T, 1202T, 1900T, 1902T **1200T and 1900T Series- 1 12 or 17 T3 **1202T and 1902T Series- 2 12 or 17 T3 *8 or 12 T3 mounting plate mounting screws *2 or 4 T3 mounting screws *1 or 2 T3 mounting plate UVE- 1200T, 1202T, 1900T, 1902T **1200T and 1900T Series- One 12 or 17 T3 **1202T and 1902T Series- Two 12 or 17 T3 *1 or 2 T3 mounting plate w/ mounting Hardware UVE- 1224T, 12242T, 1924T, 19242T **1224T and 1924T Series- One 12 or 17 T3 **12242T and 19242T Series- Two 12 or 17 T3 *1 or 2 T3 mounting plate w/ mounting Hardware *1 or 2 T3 mounting bracket assembly * Number depends on 1 or 2 T3 s ** T3 gasket included Safety Precautions: It is recommended that this unit be installed and maintained by a trained technician: WARNING: UV Hazard. Always protect eyes from ultraviolet light. NEVER look at UV lamps in operation. Unplug or disconnect power before relamping or servicing. WARNING: Severe eye damage or temporary blinding may occur. WARNING: DO NOT operate outside of Air Handler. Mount lamp base to duct first. WARNING: No openings in duct are allowed which would give direct line-of-sight to the UV light. In the event of accidental breakage or replacement of the ultraviolet lamp, please ensure that the lamp is disposed of in accordance with local and state environmental laws regarding fluorescent lamps containing mercury. Notice: All wiring inside of the duct or air handling system in direct line of site of the UV lamp must be shielded with aluminum foil tape or equivalent non-combustible material. When installing this unit, select a mounting location that prevents ultraviolet light exposure to plastic flexible duct liner or other plastic components with unknown resistance to ultraviolet light. Ultraviolet light may cause color shift or structural degradation of plastic HVAC components 2

Installation Steps for Remote UVC Units: 1. Determine a suitable location to install unit housing. Mounting location should be of sufficient strength as to support the unit; otherwise reinforcement of the ductwork may be necessary. Lift into place against ductwork. Fasten unit in place with four or six self- tapping screws (supplied). 2.Select location for UV lamp module(s). Drill a 1 hole. Insert UV lamp module into hole. Attach to HVAC system with 2 self-drilling screws (provided). Remote Installation 3.Plug plastic lamp connector onto installed UV lamp module. Be sure the connector is pushed fully onto the lamp. 3a. If unit is a UVE Model, please skip step #4 4. Before power is applied to the unit: Complete step1 if battery is not in holder. 1. Insert coin battery (+ side out, see drawing) into battery holder on circuit board, LED should turn RED for approx. 15 seconds. *If LED does not turn RED rotate battery around while in holder. 2.Depress black RESET button (hold down for 10 sec.) on circuit board, the LED should turn GREEN while the button is depressed. 3. Release the black RESET button and the LED should return to RED. UVS Battery Location You now have set the internal clock to zero insuring an accurate measurement of lamp life operating hours. UVLAMPMONITOR CIRCUIT BOARD NOTE: When replacing lamps after 9000 hours of operation (shut off power to the unit) only steps 2 & 3 will be required to set the clock back to 0 to begin counting the operating hours of the new lamp. LED ELOH0031 BATTERY HOLDER 5. Plug in unit/ make electrical connections. THIS SHOULD BE DONE IN ACCORDANCE WITH ALL STATE AND LOCAL ELECTRICAL AND BUILDING CODES. POSITIVE SIDE OF COIN BATTERY THIS DIRECTION 6. Turn on unit and inspect operation. RESET CR2032 3

Maintenance: Maintenance typically consists of an annual replacement of the ultraviolet lamps. UV lamps undergo a photochemical process during operation. This slowly reduces the amount of UV light generated to disinfect against airborne pathogens. When installing new lamps, ensure that the lamp glass is free from any fingerprints or debris, as this may alter the path of the UV energy. Use rubbing alcohol and a dry cloth to remove any surface contaminants. Troubleshooting: The Ultravation air disinfection equipment is designed to provide many years of trouble free operation. In the unlikely event of a problem, please contact your local dealer or Ultravation directly. Before calling for service, you should have your Model No; Serial No; Manufacturing Date; If you are troubleshooting the unit, check the following: It is recommended that this unit be installed and maintained by a trained technician. Never perform maintenance on the UV unit without disconnecting power. Verify the unit has power (120-277 volt) Power switch is in the ON position Safety interlock switch is depressed by the cover s are securely plugged into their sockets, no loose wires. The electronic circuit of a 2-lamp system only operates when both lamps are operating. Verify fuses are not blown, visually inspect or perform a continuity test of the fuse. Verify what signal if any the UV Monitor LED is emitting. (See below). Check Battery Voltage, should read about 2.8-3.0 V (UVS only) DC lower voltages can cause erratic LED readings Verify if in fact the UV lamps are on or off. Do not look at the UV light without proper eye protection. If possible try new lamps in Unit to see if they light. NOTE: If one lamp does not light in a 2 lamp system neither lamp will light. UV Monitor: (UVS SERIES ONLY) LED Color Audible Visual Alarm Unit Status Green No audible OK Solid Red No Audible replace lamp within 30 days Flashing Red (Every 5 seconds) Pulsing Red (Every 1 second) Beep every 3 Minutes Beep every 1 second has exceeded 1 yr. of operation, replace lamps and reset UV lamp(s) are not lit (verify if possible) Please contact your local dealer or Ultravation directly for replacement lamps and batteries There are NO user serviceable parts inside. Refer servicing to qualified service personnel. 4

PART DESCRIPTIONS: 5

Power Consumption and Replacement Part Numbers: Model Number of Power Replacement s Consumption Part # UVE-1200 1-12 Inch 19 Watts AS-IH-1001 UVE-1202 2-12 Inch 38 Watts AS-IH-1001 UVE-1900 1-17 Inch 29 Watts AS-IH-1003 UVE-1902 2-17 Inch 57 Watts AS-IH-1003 UVS-1200 1-12 Inch 19 Watts AS-IH-1001 UVS-1202 2-12 Inch 38 Watts AS-IH-1001 UVS-1900 1-17 Inch 29 Watts AS-IH-1003 UVS-1902 2-17 Inch 57 Watts AS-IH-1003 UVE-1200T 1-12 Inch 19 Watts AS-IH-1001 UVE-1202T 2-12 Inch 38 Watts AS-IH-1001 UVE-1900T 1-17 Inch 29 Watts AS-IH-1003 UVE-1902T 2-17 Inch 57 Watts AS-IH-1003 UVS-1200T 1-12 Inch 19 Watts AS-IH-1001 UVS-1202T 2-12 Inch 38 Watts AS-IH-1001 UVS-1900T 1-17 Inch 29 Watts AS-IH-1003 UVS-1902T 2-17 Inch 57 Watts AS-IH-1003 UVE 5 Amp Fuse EL-PP-0044 UVS Battery EL-PP-0030 Warranty: Ultravation warrants this product against any defects in material or workmanship for a period of 10 years after date of consumer purchase, with the exception of the Ultraviolet (s), which are warranted for a period of one year after date of consumer purchase. This warranty does not include damage to the unit from accident, misuse or improper installation. If this product should become defective during the warranty period, Ultravation will repair or elect to replace the product free of charge. Ultravation will return repaired or replaced warranted products pre-paid, provided that the product was delivered pre-paid. Ultravation shall have no responsibilities for charges incurred by the customer for installation or removal of warranted items. Liability is limited only to the replacement or repair of this product This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. All returns must be accompanied by a return authorization number, which may be obtained by contacting Ultravation, Inc. Ultravation, Inc.~ P.O. Box 234 ~ 218 Jones Drive ~ Brandon, Vermont 05733 Phone: 802-247-0034 ~ Fax: 802-247-0033 ~ www.ultravation.com 6