Product Specifications Auto Restart Main Power Distribution Panel

Similar documents
Product Specifications 480 VAC, 175A Main Power Distribution Panel

Product Specifications 480 VAC, 70A Main Power Distribution Panel

Product Specifications 3 Breaker Main Disconnect Panel with Undervoltage Trip

Product Specifications Linear Accelerator Relay Junction Box

Product Specifications 4 Breaker Main Disconnect Panel with Undervoltage Trip

Product Specifications Fail Safe Emergency Power Off Control Panel 480V 3 Phase

Product Specifications Warning Light Control Cabinet

Product Specifications Warning Light Control Cabinet

Product Specifications MaxLumen MRI LED Diffused Lighting

Product Specifications MaxLumen MRI LED Diffused Lighting

Product Specifications MaxLumen MRI LED Diffused Lighting

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

MaxLite Polygon Linear LED Light

MaxLite LED High Bay Fixtures

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

INSTALLATION INSTRUCTIONS Model FH-2071-UM Enclosure

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Electric Duct Heaters

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

Elevator Control ES Switch

Installation, Operation & Service Manual

BACKUP BATTERY INSTALLATION INSTRUCTIONS

Installation Instructions

Universal Fan and Light Remote Control

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

Instruction Manual and Warranty

1500W STOVE HEATER INSTRUCTION MANUAL. Item No: 050-HA-50090

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Standard Product. Wall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects

ASCO Series 185 Power Transfer Switches

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

SIMPLEX WEATHERPROOF CONTROL PANELS

CURRENT LIMITING LIGHTING CONTROL PANEL Supplemental Overcurrent Protection City of Los Angeles Approved Version

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

Thermostats. Digital Non-Programmable. GEAppliances.com. Owner s Manual & Installation Instructions RAK148D2 RAK164D2

AquaSaver DISPOSER CONTROL CENTER Installation Manual. Model AS-101K

VT SERIES VERTICAL TOASTER OPERATOR S MANUAL TABLE OF CONTENTS

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

CABINET INFRARED HEATER

Guide Specification Model CTG Automatic Transfer Switch

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Drawing Submittal Package

ion Genesis Pump Controller

Desiccant / Pump Dehumidification System. Model Operating Manual

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

INSTALLATION and OPERATION INSTRUCTIONS

Quest Power Electric Heat EHS 62 Pro

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

GRUNDFOS INSTRUCTIONS CMBE. Installation and operating instructions. Drinking Water System Component NSF / ANSI 61 NSF / ANSI 372

CurrentGuard TM. Installation, Operation and Maintenance Manual. CurrentGuardTM. Flush Mount. Surge Protective Devices A00

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Drawing Submittal Package

Phoenix AirMAX - Radial Air Mover

Service Parts, Kits and Accessories

Hardwired Model Shown. Installation & Operation Manual for WarmlyYours Infinity Towel Warmers

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

Model 4001 Series Single Channel Controller

Beacon 800 Gas Monitor Operator s Manual

Installation & Operation Manual for WarmlyYours Towel Warmers

Digital Non-Programmable

Panel Mounted Heat Exchangers by Dantherm, Inc.

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

Securitron. Switching Power Supplies

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR200-24S / OPR200-24R. Manual

Installation & Operation Manual for WarmlyYours Towel Warmers

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

SU2000-SM. model OPTICAL TURNSTILES DESCRIPTIVE SPECIFICATIONS TYPICAL INSTALLATION SITES COMMON APPLICATIONS ALVARADOMFG.COM

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

Installation Manual. Models 99168, 99169, 99170

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

Pump-Up Controller MODEL 4062

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Wall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects

InstructIon Manual KrEs EQuIPMEnt stands

Operation Manual. An investment of a small amount of time to review this manual will ensure proper performance of your Coal-Trol Digital system.

5600 series. Low Energy Power Operator

SECTION AUTOMATIC TRANSFER SWITCHES

VENTILATION FAN WITH LIGHT AND HEATER

Hazardgard. Product Profile. Engineered to perform in the harshest environments. Hazardous Location Room Air Conditioners

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

Transcription:

NOVA Energy & Automation Product Specifications Auto Restart Main Power Distribution Panel Model NEA090AR/RTX 03 January 2012

Product Description 1. Standard Application The Nova Auto Restart system Main Disconnect Panel (MDP) serves as the main facility power disconnect source installed ahead of the medical imaging equipment. Each MDP is sold with 2 remote Emergency stop Buttons. The MDP saves time, installation labor, and valuable mounting space by consolidating the main circuit breaker and the feeder over current devises into one integrated panel. The panel design includes short circuit, overload, Undervoltage release, and emergency shutdown of the system. All power is controlled by an ADA approved through the door disconnect or by the remote emergency operator control station. Source 90, 110, 125, 150A 400-480V, 50/60Hz, 3 Phase, 3 Wire + Ground, 3/0 Cables Max System Emergency Off Pushbuttons as required (12VDC, single phase W/ ground #14-#12 TYPICAL) SYSTEM MAIN DISCONNECT (2) REMOTE EMERGENCY OFF PUSHBUTTONS W/ EACH DISCONNECT LOAD WIRE SIZE 1/0 CABLES, MAX PDU OPTIONAL UPS OPTIONAL UPS DISCONNECT PANEL Figure 1 Nova Auto Restart Main Disconnect Application Diagram 2. Application of Auto Restart The MDP includes an automatic restart control circuit which restores power to the imaging equipment after any power outage due to storms, poor power quality or generator testing. Imaging equipment that is installed in a facility with emergency power will benefit from autorestart each month when the emergency power is tested (NFPA 110). During the emergency power test the power will cycle on and off several times to test the generators and transfer switches. This cycling will disrupt the power to the main disconnect and power down temporarily. Once the power has been restored- the main disconnect will automatically restart to its previous state (ON/OFF) at full functionality. Imaging equipment used in large imaging centers requiring a heavy power load, locations with heavy construction nearby, or locations with a history of poor power will also benefit from auto restart. Co Author: JF 2

The Auto restart feature in the panel also provides built in controls for a main modality UPS and a operators console UPS. 3. System Compatibility Imaging Equipment Manufacturer GE Healthcare GE Healthcare Equipment Description Radiography and Flouro (R&F) 90 Amp models Radiography 90 Amp models Equipment Model Number Precision 500D And related installations Discovery XR 656 Discovery XR 650 Optima XR 640 Brivo Definium 5000 Silhoutte Proteus And related installations Nova Panel NEA090AR/RTX NEA090AR/RTX 4. Identification GE Healthcare- The proper panel can be identified on GE Healthcare Drawings: Sheet E1 Right Column Junction Point Descriptions A, A1, or MDP Main Disconnect: E4502RP Equal to NEA090AR/RTX 5. Features/ Benefits Features UL and cul listed to conform to NEC Available from stock Supports modality UPS and operators console UPS Labeled to conform with NFPA99, NFPA-70, NEC 100, NEC 110-3, NEC 660.5 Provides over current and short circuit protections Short circuit current rated at 25kAIC Undervoltage Circuit protection Single point main disconnect and termination point American Disabilities Act (ADA) approved through the door disconnect handle provides one hand ON/OFF operation. Lock Out/ Tag Out lockable operating handle provides added safety during maintenance and OSHA requirements. Co Author: JF 3

Interlocked ON/OFF hinged door prevents access to the panel while the disconnect is in the ON position. Door may be locked closed with customer provided padlock. ¼ turn slotted door latch provides additional security. Isolated Neutral lugs Oversized ground lugs for parity sizing of ground wire Compact size for easy installation Thermal protection Factory wired to match GE equipment and tested Disconnect automatically shuts down during first loss of power, preventing damage to system components Electronic based auto restart Manufactured in the USA Benefits Designed, tested, and installed on hundreds of projects worldwide Acceptable low cost alternative to GE Manufactured using the highest quality components for high reliability and long life Provides protection for sensitive electronic equipment Manufactured to a tolerance which exceeds the specifications of GE Medical equipment. Easy to view LED indicator lights for System ON Field adjustable overload and instantaneous trip Reduced weight- all components are within a small 45lb enclosure Reduces installation time and cost by eliminating delays in obtaining individually enclosed components and by eliminating on site assembly Provides a standardized platform for other future modifications or upgrades Maintenance free design does not require battery Electronic auto restart resets the system to the previous state (ON/OFF) preventing the system from restarting after the system has been intentionally shut down. The ADA handle makes turning the imaging equipment on and off during emergencies or power failures easy for technicians and nursing staff. Co Author: JF 4

Figure 2 Nova Auto Restart Main Disconnect Panel 6. Specifications Model Application Input Voltage Output Voltage Control Voltage Emergency Power Off Controls Operators Controls Compatible Estop Buttons Grounding Overload Current Protection Short Circuit Current Protection Instantaneous Trip Settings Approvals NEA090AR/RTX Auto Restart Main Disconnect Panel for medical imaging installations 480VAC (please specify if other voltage is required) 480VAC (please specify if other voltage is required) Internally derived 120VAC and 24VDC for controls 120VAC Undervoltage release (N.O) Compatible with EPO and Remote Start Normally closed contacts GE X-ray, RF, 2 ESTOPS- 1 N.O, 1 N.C. contacts Isolated and non isolated ground bar Factory set to 90A 25 kaic Field adjustable from 1-10x of over current rating UL/cUL Co Author: JF 5

Figure 3 Nova Auto Restart Main Disconnect Panel- Inside 7. Weights and Dimensions Mounting Dimensions Weight Mounting Enclosure Enclosure Sealing Main disconnect is provided in a steel enclosure suitable for surface or semi flush installations. Height: 29.92 (760mm) Width:23.62 (600mm) Depth: 5.9 (150mm) 105 lbs. (47.3 kg) Rear wall mounting holes (4). Spaced 0.79 (20mm) from enclosure edge. Optional mounting brackets are available 16 Gauge Carbon Steel, all rounded corners 1 gland plate in the enclosure base. Foamed-in place polyurethane door gasket Finish Dip coat primed, powder coated in textured RAL 7035 Latching Mechanism Interior Panel Protection Category Two ¼ turn latches with double-bit inserts (cam lock). Door is hinged on the left side but can be swapped if specified when order is placed. Zinc-Plated subpanel IP 66 to EN60 529/09:2000, complies with NEMA 4 Enclosure Approvals: UL, CSA, TUV, GL, Lloyds, VDE, Bureau Veritas Co Author: JF 6

Figure 4 Enclosure Dimensions: Outside, Mounting, Depth 8. Warranty This limited warranty set forth below is given by Nova Automation ( Seller ) with respect to the electrical equipment ( Product ) packaged with this limited warranty. The Product, when delivered to you in new condition in its original packaging, is warranted against defects in materials or workmanship as follows: For a period of one (1) year from the date of original purchase, defective parts or a defective Product returned to a Seller, or its authorized service providers, as applicable, and proven to be defective upon inspection, will be repaired, or exchanged for a new Product, as determined by the Seller, or the authorized service provider. This limited warranty covers all defects encountered in normal use of the Product, and does not apply in the following cases: Loss of or damage to the Product due to abuse, mishandling, alteration, accident, electrical current fluctuations, failure to follow operating, maintenance or environmental instructions prescribed by Seller, failure to follow Sellers installation instructions, or service performed by someone other than Seller or its authorized service provider. Nova assumes no responsibility for labor or freight costs incurred in connection with the installation, removal, or replacement of products determined to be defective or any consequential or incidental damages arising from the use of the product. Nova Automations entire liability on any claim of loss or damage resulting from a defective product is limited to the replacement of the product. WARRANTY IS VOID IF PRODUCT IS NOT USED FOR THE PURPOSE FOR WHICH IT WAS MANUFACTURED. Co Author: JF 7

9. Product Service and Technical Assistance Nova Automation, LLC 2722 N. Avondale Blvd Milwaukee WI 53210 PH# 262-309-2950 Website: www.novaautomation.net 10. Approvals Prepared By ([Job Title]) This document requires the following approvals Approved By ([Job Title]) ([Job Title]) Approval Date Co Author: JF 8