Fire Sprinkler Monitoring Products. Solutions and Service for Sprinkler System Integrity

Similar documents
WFDE Series Waterflow Detector

Full Line Catalog and Product Brochures

Fire Sprinkler Systems Monitoring

Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring

WFD Vane-type Waterflow Detectors

FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT

VSR-M REPLACEMENT Waterflow Switch for Globe Sprinkler Model UMC Manifold

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

DIVISION 21 - FIRE SUPPRESSION

TECHNICAL DATA EASYPAC COMMERCIAL RISER MANIFOLD ASSEMBLIES 1-1/4-8 (DN32 - DN200)

Fire Sprinkler Monitoring & Releasing Systems. Training Manual. Manual # REV H 7/18

TECHNICAL DATA. 32a. September 18, /4-8 (DN32 - DN200)

Instructions for. Care and Maintenance 10 psi (0,7 bar) Pneumatic Supervising Pressure. Single Interlock

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Model VSR, VS-F FM Approvals. All rights reserved. 1 of 1

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

DIVISION 21 - FIRE SUPPRESSION

Specification/ Data Sheet

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Instructions for Installation, Operation, Care and Maintenance

ZC450-IB-09/13-01 US. Instruction Booklet. Zonecheck 450

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)

HOW COMMERCIAL FIRE PROTECTION SPRINKLER SYSTEMS REALLY OPERATE

Release Control Fire Alarm Systems

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 8 Annual Sprinkler System Inspection Revised

Fire Sprinkler Monitoring Product Catalog

CONSTRUCTION REQUIREMENTS

TECHNICAL DATA. 31a. September 18, (DN25 - DN50)

Electric Release Panel Wiring Tips

AlarmLine Addressable Linear Heat Detector

TECHNICAL DATA OBSOLETE

TOTALPAC2 Integrated Fire Protection System

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

WFD Series Waterflow Detector

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

Commercial and Light Industrial Fire Alarm Control Panel

TotalPac X Single interlock SUREFIRE system

Technical Data. Installation

Advanced Integrated Fire Protection Systems TOTALPAC 2. Owner's Operation and Maintenance Manual FIRECYCLE III. September 2009 FM-086G-0-5E

TotalPac 3 Wet pipe system c/w retard chamber

TECHNICAL DATA. 319a. January 27, 2012

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

Reshaping Duct Smoke Detection

Flow Control for Fire Protection

Fire Sprinkler Monitoring Product Catalog

Doc. No Part No Rev. U * T*

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

SECTION FIRE PROTECTION

TotalPac X Firecycle III Preaction Double interlock system

Global Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

CO/Smoke Detection PRODUCTS. Accessories Conventional Detectors and Modules

Corrosion in Fire Sprinkler Systems Increasing Your Liability, Increasing Your Costs, and Shortening System Life

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

30.45 Electric Release PDRP-2001

TECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5

Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH ELECTRIC RELEASE

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

FireLock High Pressure Butterfly Valve. System No. Submitted By Spec Sect Para Location Date Approved Date

Gas Station & C Store SECTION CWM Job No

Report of Inspection/Test

Specialties Quality, Durability, Reliability. FIrE ProTECTIon

SPRINKLERS TABLE OF CONTENTS

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

FIRE-PAC SERIES 745 FIRELOCK SYSTEMS

TotalPac 3 Firecyle III Deluge Remote controlled system

FireFlex DUAL Double Interlock, Self-contained system

2016 CDM Smith All Rights Reserved July 2016 SECTION FIRE PROTECTION - SPRINKLER AND STANDPIPE SYSTEMS

N2 BLAST Datasheet Preaction double interlock, Electric/Pneumatic c/w N 2 Blast Nitrogen generating system Self contained unit

good things in small packages

Sprinkler Inspection Certificate

Flow Control for Fire Protection

Chapter 4: Fire Protection Systems

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

B. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.

Chubb Monitoring Solutions

SECTION Fire Pumps

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION

TrueAlert Notification Appliances

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

SECTION AUTOMATIC TRANSFER SWITCHES

DATA SHEET ZoneCheck Automatic Flow Switch Tester

Service Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT

TECHNICAL DATA OBSOLETE

Pre-Pack INTEGRATED PRE-ACTION SYSTEM

Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System

Transcription:

Fire Sprinkler Monitoring Products Solutions and Service for Sprinkler System Integrity

waterflow monitoring Monitoring Fire Sprinkler System Flow During a fire condition, sprinkler system reliability is critical, whether it s the operation of a sprinkler or the monitoring of the sprinkler system itself. System Sensor s line of waterflow detectors provides that reliability when monitoring water flow within a wet pipe fire sprinkler system. These vane-type paddle designs are available in a variety of configurations and accommodate 2 through 8 pipe for commercial riser applications, as well as 1 NPT connections for residential or branch line signaling. To minimize the risk of false alarms, System Sensor flow switches offer two distinct options for the retard mechanisms. The WFD series detectors provide a mechanical delay that is adjusted via an adjustment wheel. The Accuflow series offers a solid state retard that provides greater precision, for timing accuracy to within one (1) second. We also offer several specialty waterflow detectors, for truly unique applications. The WFD-EXP line of explosion-proof waterflow detectors is intended for hazardous locations where volatile vapors or particulates may be present. And for wet pipe water mist systems requiring flow detection of three (3) gallons per minute, System Sensor offers the Accuflow Low Flow series.

flow testing Testing and maintaining a fire sprinkler system is as important as the monitoring devices. System Sensor s Zonecheck flow switch testers provide a cost-effective means for meeting your flow switch test requirements. Assuring Waterflow Detector Readiness Zonecheck flow switch testers re-circulate the water within the sprinkler riser around the waterflow detector to simulate the flow of one sprinkler in operation. By doing so, the waterflow detector may be tested without having to open the inspector s test connection. Through Zonecheck s interconnection feature, an entire building s waterflow detectors may be tested within a matter of seconds, thereby saving water, time and money.

valve monitoring pressure and The nerve centers of a fire sprinkler system are the switches and valves that control the entire system. Again, System Sensor offers a variety of choices for supervising system control valves. Regardless of valve type: OS&Y, post indicator, butterfly, or non-rising stem gate valve, our OSY2, PIBV2, and PSP1 models provide you with the peace of mind that your system s control valves are being monitored. Monitoring the Fire Sprinkler System s Status System Sensor s line of pressure switches includes the EPS10 series for use in wet, dry, deluge and preaction automatic sprinkler systems to indicate a discharge from a sprinkler. The EPS40 and EPS120 series supervisory pressure switches are intended for dry pipe systems or pressure tanks and water supplies of automatic water control valves. These models offer a choice of initiating low, or high/low pressure alarms, in a variety of pressure ranges. And should your system involve a potentially hazardous location, we offer a complete line of explosion-proof alarm and supervisory pressure switches. In every case, you are assured of technically superior choices with System Sensor products.

Completing the System Sensor line of sprinkler monitoring products are the PDRP series control panels and SSV/SSM series alarm bells. Our reliable system provides a way to detect and respond to changes on all initiating and release circuits, reducing the risk of loss from fire. Combined with our alarm bells, signaling any change in your fire sprinkler system is easy. Information to Help You Act System Sensor s control panels and alarms provide the information you need to take action when you need it. The PDRP series include fault supervision and fuse protection on all initiating and release circuits, with up to 90 hours of standby. Depending upon the model, the PDRP panels offer compliance with NFPA 71, NFPA 72, NFPA 12, NFPA 12A, and NFPA 12B standards. system System Sensor s alarm bells deliver high sound pressure output for fire signaling needs. Models are available for 120VAC and 24VDC operating voltage and are offered in 6, 8 and 10 sizes. In all cases, these are the products you can count on because they carry the System Sensor name. alarms

Specifications WFD Series Waterflow Detectors* Model No. Pipe Size Pipe Schedule UL Pressure Rating Enclosure Rating Agency Approvals** WFD20 2 10 through 40 450 PSI UL NEMA 4 UL, FM, CSFM, MEA, CNTC WFD25 2.5 10 through 40 450 PSI UL NEMA 4 UL, FM, CSFM, MEA, CNTC WFD30-2 3 10 through 40 450 PSI UL NEMA 4 UL, FM, CSFM, MEA WFD35 3.5 10 through 40 450 PSI UL NEMA 4 UL, FM, CSFM, MEA, CNTC WFD40 4 10 through 40 450 PSI UL NEMA 4 UL, FM, CSFM, MEA, CNTC WFD50 5 10 through 40 450 PSI UL NEMA 4 UL, FM, CSFM, MEA, CNTC WFD60 6 10 through 40 450 PSI UL NEMA 4 UL, FM, CSFM, MEA, CNTC WFD80 8 10 through 40 450 PSI UL NEMA 4 UL, FM, CSFM, MEA, CNTC WFDT 1 NPT Connection (Refer to Data Sheets) 250 PSI UL NEMA 4 UL, CSFM, MEA, CNTC WFDTH 1 NPT Connection (Refer to Data Sheets) 250 PSI UL NEMA 3 UL, CSFM, MEA WFDTNR 1 NPT Connection (Refer to Data Sheets) 250 PSI UL NEMA 4 UL, CSFM, MEA Explosion-proof Waterflow Detectors Model No. Pipe Size Pipe Schedule UL Pressure Rating Enclosure Rating Agency Approvals** WFD20EXP 2 10 through 40 450 PSI UL NEMA 4 UL, ULC, FM, CSFM, MEA WFD25EXP 2.5 10 through 40 450 PSI UL NEMA 4 UL, ULC, FM, CSFM, MEA WFD30-2EXP 3 10 through 40 450 PSI UL NEMA 4 UL, ULC, FM WFD35EXP 3.5 10 through 40 450 PSI UL NEMA 4 UL, ULC, FM, CSFM, MEA WFD40EXP 4 10 through 40 450 PSI UL NEMA 4 UL, ULC, FM, CSFM, MEA WFD50EXP 5 10 through 40 450 PSI UL NEMA 4 UL, ULC, FM, CSFM, MEA WFD60EXP 6 10 through 40 450 PSI UL NEMA 4 UL, ULC, FM, CSFM, MEA WFD80EXP 8 10 through 40 450 PSI UL NEMA 4 UL, ULC, FM, CSFM, MEA These units intended for use in hazardous locations classified as follows: Class I, Groups B, C, D, Division 1 & 2; Class II, Groups E, F, G, Division 1 & 2; Class III, Division 1 & 2. Accuflow Series Solid State Waterflow Detectors* Model No. Pipe Size Pipe Schedule UL Pressure Rating Enclosure Rating Agency Approvals** AFD20 2 5 through 40 450 PSI UL NEMA 4 UL, FM AFD25 2.5 7 through 40 450 PSI UL NEMA 4 UL, FM AFD30-2 3 7 through 40 450 PSI UL NEMA 4 UL, FM AFD35 3.5 7 through 40 450 PSI UL NEMA 4 UL, FM AFD40 4 7 through 40 450 PSI UL NEMA 4 UL, FM AFD50 5 7 through 40 450 PSI UL NEMA 4 UL, FM AFD60 6 7 through 40 450 PSI UL NEMA 4 UL, FM AFD80 8 10 through 40 450 PSI UL NEMA 4 UL, FM AFDT 1 NPT Connection n/a 250 PSI UL NEMA 4 UL, FM AFDTH 1 NPT Connection n/a 250 PSI UL NEMA 3 UL, FM Accuflow Low Flow Waterflow Detectors Model No. Pipe Size Compatible Pipe UL Pressure Rating Enclosure Rating Agency Approvals** LFD20 2 Brass/Stainless Steel 450 PSI UL NEMA 4 UL LFD25-73MM 2.5-73MM O.D. Brass/Stainless Steel 450 PSI UL NEMA 4 UL LFD25-76MM 2.5-76MM O.D. Brass/Stainless Steel 450 PSI UL NEMA 4 UL LFD30-2 3 Brass/Stainless Steel 450 PSI UL NEMA 4 UL LFD40 4 Brass/Stainless Steel 450 PSI UL NEMA 4 UL Zonecheck Waterflow Detector Testers* Model No. Model Type Pipe Size Pipe Schedule Agency Approvals** ZC20 Manifold Assembly 2 10 UL ZC25 Manifold Assembly 2.5 10 UL ZC30 Manifold Assembly 3 10 UL ZC40 Manifold Assembly 4 10 UL ZCR20 Retrofit Assembly 2 10 through 40 UL ZCR25 Retrofit Assembly 2.5 10 through 40 UL ZCR30 Retrofit Assembly 3 10 through 40 UL ZCR40 Retrofit Assembly 4 10 through 40 UL ZCR60 Retrofit Assembly 6 10 through 40 UL ZCR80 Retrofit Assembly 8 10 through 40 UL *Canadian and International models are also available. Call for details. **Additional agency approvals pending. Call for details.

EPS Series Pressure Switches* Adjustment Model No. Pressure Range Factory Setting Enclosure Rating Agency Approvals** EPS10-1 4-20 PSI Operates at rising pressure 4-8 PSI UL NEMA 4 UL, FM, CSFM, MEA EPS10-2 4-20 PSI Operates at rising pressure 4-8 PSI UL NEMA 4 UL, FM, CSFM, MEA EPS40-1 10-100 PSI Operates at decreasing pressure at 30 PSI UL NEMA 4 UL, FM, CSFM, MEA EPS40-2 10-100 PSI Operates at increasing pressure at 50 PSI UL NEMA 4 UL, FM, CSFM, MEA and decreasing pressure at 30 PSI EPS120-1 10-200 PSI Operates at decreasing pressure at 105 PSI UL NEMA 4 UL, FM, CSFM, MEA EPS120-2 10-200 PSI Operates at increasing pressure at 125 PSI UL NEMA 4 UL, FM, CSFM, MEA and decreasing pressure at 105 PSI Explosion-proof Pressure Switches Adjustment Model No. Pressure Range Factory Setting Enclosure Rating Agency Approvals** EPS10EXP 4-20 PSI Operates at rising pressure 4-8 PSI UL NEMA 4 UL, ULC, FM, CSFM, MEA EPS40EXP 10-100 PSI Operates at increasing pressure at 50 PSI UL NEMA 4 UL, ULC, FM, CSFM, MEA and decreasing pressure at 30 PSI EPS120EXP 10-200 PSI Operates at increasing pressure at 125 PSI UL NEMA 4 UL, ULC, FM, CSFM, MEA and decreasing pressure at 105 PSI These units intended for use in hazardous locations classified as follows: Class I, Groups B, C, D, Division 1 & 2; Class II, Groups E, F, G, Division 1 & 2; Class III, Division 1 & 2. Control Valve Supervisory Switches* Model No. Valve Types Enclosure Rating Agency Approvals** OSY2 Outside screw and yoke valves UL NEMA 3 UL, FM, CSFM, MEA PIBV2 Post indicator valves, butterfly valves with rising or falling flags UL NEMA 3 UL, FM, CSFM, MEA PSP1 Non-rising stem gate valves, ball and angle valves UL NEMA 3 UL, FM Explosion-proof Control Valve Supervisory Switches Model No. Valve Types Enclosure Rating OSYEXP Outside screw and yoke valves NEMA 1, 7, and 9 PIBVEXP Post indicator valves, butterfly valves NEMA 1, 7, and 9 These units intended for use in hazardous locations classified as follows: Class I, Groups C, D, Division 1 & 2; Class II, Groups E, F, G, Division 1 & 2; Class III, Division 1 & 2. Alarm Bells* Model No. Size Operating Voltage Range Current Draw Sound Output Agency Approvals** SSV120-6 6 96-132 VAC 0.047A 82 dba UL, FM, CSFM, MEA SSV120-8 8 96-132 VAC 0.047A 85 dba UL, FM, CSFM, MEA SSV120-10 10 96-132 VAC 0.047A 82 dba UL, FM, CSFM, MEA SSM24-6 6 19.2-26.4 VDC 0.030A 85 dba UL, FM, CSFM, MEA SSM24-8 8 19.2-26.4 VDC 0.030A 85 dba UL, FM, CSFM, MEA SSM24-10 10 19.2-26.4 VDC 0.030A 85 dba UL, FM, CSFM, MEA PDRP Series Fire Alarm Control Panels* Model No. Description Agency Approvals** PDRP-1001 Two-zone pre-action/deluge fire alarm control panel UL, FM, CSFM, MEA PDRP-1002 Two-zone agent releasing fire alarm control panel UL, FM, CSFM, MEA Sprinkler Monitoring Device Accessories Model No. WFDW S07-66-05 C58-164-01 Description Cover wrench for WFD, AFD, LFD, EPS, OSY2, PIBV2, and PSP1 series products Cover tamper screws for WFD, AFD, LFD, EPS, OSY2, PIBV2, and PSP1 series products Replacement cover for WFD, AFD, and LFD series waterflow detectors 546-7000 Cover tamper switch kit for WFD, OSY2, and PIBV2 series products 546-8000 Cover tamper switch kit for EPS series pressure switches 546-9000 Cover tamper switch kit for AFD and LFD series waterflow detectors WFDN4 PRK9 NEMA 4 gasket replacement kit for WFD, AFD, and LFD series waterflow detectors Paddle kit for WFDT and AFDT series waterflow detectors A3008-00 Replacement retard kit for WFD series waterflow detectors AFDPCBRK A77-01-02 HEXW Replacement retard kit for AFD and LFD series waterflow detectors Replacement terminal block kit for WFD series waterflow detectors Replacement hex wrench for OSY2 and PIBV2 supervisory switches *Canadian and International models are also available. Call for details. **Additional agency approvals pending. Call for details.

How can you be sure that YOUR system will operate when needed? The National Fire Protection Association (NFPA) records indicate that 96% of all fires occurring in sprinklered buildings were extinguished or held in check by the system, and 80% of those fires were controlled by the activation of fewer than 8 sprinkler heads. The question then becomes: How can you be sure that your system will operate when needed? System Sensor Sprinkler Monitoring Devices System Sensor products supervise sprinkler systems by monitoring valve positions, system pressure and water flow. They in turn assure system reliability and effectiveness. When it comes to installing the very best, always specify System Sensor fire sprinkler monitoring devices. Trust your fire sprinkler monitoring to System Sensor. Our engineered products help keep people and property safe. System Sensor is a global manufacturer of fire detection and notification devices, specializing in smoke detection and notification technology. System Sensor places a premium on research and development, resulting in products that are reliable, sophisticated, and designed for real-world applications. With sales, service, and manufacturing facilities throughout the Americas, Europe, and Asia, System Sensor s high quality, innovative products are the most comprehensive in the industry. 2000 System Sensor The Company reserves the right to change product specifications at any time. A05 0298 000