SPLIT-SYSTEM CONDENSING UNITS. "HRC" Series SEER. Models H*RC018 thru H*RC060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES

Similar documents
SPLIT-SYSTEM CONDENSING UNITS. HRC Series TECHNICAL SPECIFICATIONS

SPLIT SYSTEM HEAT PUMPS "ERC" Series

SPLIT SYSTEM HEAT PUMPS 14 SEER

TECHNICAL GUIDE STELLAR 2000 TM MODELS: E*FD018 THRU E*FD060 1 Ø E*FD036 THRU E*FD060 3 Ø SPLIT-SYSTEM HEAT PUMPS Rev A (0500)

TECHNICAL GUIDE STELLAR 2000 TM MODELS: H*DB012 THRU H*DB076 (1 Ø & 3 Ø) SPLIT-SYSTEM AIR CONDITIONERS A TG2Y (02/00) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

2220 SE Ninth Avenue 2113 Delta Waters Road Portland OR Medford OR

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

CONDENSING UNITS SPLIT-SYSTEM COOLING 1.5 TO 5 TONS INSTALLATION INSTRUCTION MODELS H*DE018 THRU H*DE060 NOMENCLATURE GENERAL LIMITATIONS INSPECTION

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Commercial High-Efficiency Condensing Units

14 AC x

Commercial High-Efficiency Condensing Units

R4H4. Product Specifications

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

September, Ductless Split Ceiling Cassette Ductless Mini-Split Models SSD, SSH and SCW

R4H4. Product Specifications

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

Split System Cooling Product & Performance Data

TECHNICAL SPECIFICATIONS

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

TECHNICAL SPECIFICATIONS

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

TECHNICAL SPECIFICATIONS

PAJ3. Product Specifications

PACKAGE AIR CONDITIONER

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

N4A6. Product Specifications

PAR5. Product Specifications

PRODUCT SPECIFICATIONS

T P A 120 S 4 S N 1 Y

TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

2 shp 13 lc 1 36 t - 1 a

N4H4. Product Specifications

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

MERIT SERIES Up Flow / Horizontal

13 SEER HEAT PUMPS. Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Split System Heat Pump Product Data

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

INSTALLATION INSTRUCTION

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

XC17. DAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology. SEER up to to 5 Tons Cooling Capacity - 21,800 to 59,000 Btuh

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

MERIT Series R-410A - Upflow / Horizontal

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

TECHNICAL SPECIFICATIONS

MERIT Series R-410A - Upflow / Horizontal

MODELS B1PA024, 030 AND 036

Split System Heat Pump Product Data

TECHNICAL SPECIFICATIONS

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

WJH4 Product Specifications

AMERICAN STANDARD 14 MODELS 4A7B E

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Split System Cooling Product Data

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195)

Split System Cooling Product Data

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

13 GEP A L P - 1 A

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

Split System Cooling Product Data

Split System Heat Pump Product Data

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

SUNLINE 2000 SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS DESCRIPTION FEATURES

Transcription:

550.48-TG1Y (296) SPLIT-SYSTEM CONDENSING S "HRC" Series - 0 SEER Models H*RC018 thru H*RC060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION The HRC Series condensing unit is the outdoor part of a versatile system of air conditioning. It is designed to be custom-matched with one of our complete line of evaporator sections, each designed to serve a specific function. Matching Air Handlers are available for upflow, downflow or horizontal application to provide a complete system. Electric heaters are available if required. Add-On coils are available for use with upflow, downflow or horizontal furnaces. FEATURES QUALITY CONDENSER S - The coil is constructed of copper tube and hardened aluminum fins for durability and long lasting efficient operation. The decorative 2" x 4" grille backed by the black coated fins, enhances appearance and protects the unit. PROTECTED COMPRESSOR - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protect the compressor if undesirable operating conditions occur. A liquid line filter-dryer further protects the compressor. DURABLE FINISH - Cabinet is made of pre-painted steel. The pre-treated flat galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and glossy earth tone finish insure less fading when exposed to sunlight. LOER INSTALLED COST - Installation time and costs are reduced by easy power and control wiring connections. Discharge line heat exchanger knockouts are provided,if required. Available in sweat connect models only. The unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof. Start-assist components included as standard where TXV is required. TOP DISCHARGE - The warm air from the top mounted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications. LO OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise up away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds. LO MAINTENANCE - Long life permanently lubricated motorbearings need no annual servicing. EASY SERVICE ACCESS - Fully exposed refrigerant connections and a single panel covering the electrical controls and the molex plug in the control box connecting the condenser fan, make for easy servicing of the unit. SECURED SERVICE VALVES - Secured re-usable service valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

550.48-TG1Y CAPACITY - ith Air Handler Coils AIR HANDLER 2 2 ELECTRIC RATED NET MBH K SEER HEAT K CFM TOTAL SENS. TXV 1 EER 1 Phase HRC / NAH & NFA H1RC018 N2AHD10 5,8,10,13,15 16 G3HC024 19.0 14.3 1.73 650 G3HC030 19.5 15.0 1.70 H1RC024 N2AHD10 5,8,10,13,15 16 G3HC030 850 24.0 18.0 2.24 10.7 N4AHD14 5,10,15,20,25 22 G3HC036 1000 29.0 21.8 2.82 10.3 N4NHD14 5,10,15,20,25 22 G3HC036 33.0 24.8 3.27 10.5 1200 G3HC042 35.0 26.3 3.13 11.2 N2AHD14 5,10,15,20,25 22 G3HC042 1400 41.0 30.8 3.90 10.5 N4AHD16 8,10,15,20,25,30 26 G3HC048 1400 42.0 31.5 3.89 10.8 N4AHD16 8,10,15,20,25,30 G3HC048 45.5 33.7 4.14 26 N4AHD20 8,10,15,20,25,30 G3HC060 48.0 36.5 4.18 H1RC060 N4AHD20 8,10,15,20,25,30 26 G3HC060 1850 57.5 43.1 5.53 10.5 1 Phase HRC / NVS - VARIABLE SPEED H1RC018 N1VSD10 5,8,10,13,15,20 G3HC024 650 19.4 14.7 1.61 13.0 16 5,8,10,13,15,20 G3HC030 650 19.9 15.4 1.58 13.5 12.6 H1RC024 N1VSD10 5,8,10,13,15,20 16 G3HC024 850 22.7 17.1 2.08 10.9 G3HC030 850 24.4 18.4 2.12 12.7 N1VSD10 16 G3HC030 1000 29.2 23.2 2.73 12.3 10.7 5,8,10,13,15,20 N1VSD14 22 G3HC036 1000 29.5 23.2 2.63 13.1 11.2 N1VSD14 5,8,10,13,15,20 22 G3HC036 1200 33.5 25.1 2.98 11.2 G3HC042 1200 35.4 27.0 2.98 12.6 11.9 N1VSD14 5,8,10,13,15,20 G3HC042 1400 41.2 31.0 3.81 10.8 22 N1VSD20 5,8,10,13,15,20 G3HC048 1400 42.6 32.0 3.70 12.7 N1VSD20 5,8,10,13,15,20 G3HC048 46.0 34.2 3.96 12.6 11.6 22 5,8,10,13,15,20 G3HC060 48.6 37.0 4.00 13.2 12.2 H1RC060 N1VSD20 5,8,10,13,15,20 22 G3HC060 1850 57.9 43.9 5.39 12.3 10.7 AIR HANDLER 2 ELECTRIC HEAT K 1 Phase HRC / F1RP/F1RC RATED CFM NET MBH TOTAL SENS. H1RC018 F1RC024 5, 7.5, 10 18 650 19.0 14.0 1.73 F1RP024 5, 7.5, 10 18 650 19.0 14.25 1.71 H1RC024 F1RP030 5, 7.5, 10, 15 18 850 23.0 17.25 2.50 F1RP036 5, 7.5, 10, 15 21 1000 29.0 21.8 2.82 10.3 F1RP036 5, 7.5, 10, 15 21 1200 34.0 25.5 3.27 Rated in accordance with DOE test procedures (Federal Register 12-27-79) and ARI Standards 210. Cooling MBH based on 80 F entering air temperature, 50% RH, and rated air flow. K includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor. EER (Energy Efficiency Ratio) is the total cooling output in BTU s at a 95 F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. 1 Thermal Expansion Valve kit required on indoor coil to obtain system performance. (Start assist components included, except 060 model which does not require due to scroll compressor.) K SEER TXV 1 2 To meet Florida R=4.2 insulation code requirements, substitute N1FA for N2AH, N3FA for N4AH, G1FC for G3HC, F1FP for F1RP and F1FC for F1RC models. All ratings remain the same. 3 P2MP, P2MPV, and P2UR furnaces and FRP/FRC Air Handlers have B.O.D. standard. P1SP furnace requires B.O.D. accessory (#2FD06700224). ** Field transition may be required. = Not Applicable. EER 2 Unitary Products Group

CAPACITY - ith 80% Furnace and Coils RATED NET MBH K SEER # MBH CFM TOTAL SENS. TXV 1 EER 1 Phase H1RC / UPFLO & S P2MPD08 3 48 16 G3UA024 1.70 H1RC018 650 19.0 14.3 P2MPD08 3 32 12 M3UF024 1.75 10.9 P2MPD08 3 G3UA030 17.3 2.50 32 12 850 23.0 M3UF024 16.9 2.19 11.4 P2MPD08 3 48 M3UF032 23.0 17.3 2.21 H1RC024 P2MPD12 3 48 16 850 G3UA036 24.0 18.0 2.18 12.2 P2MPD12 3 64 P2MPD14 3 G3UA037 18.7 2.18 12.2 80 22 850 24.0 M3UF044 18.2 2.22 10.8 P2MPD12 3 48 M3UF032 16 28.0 20.2 2.80 11.4 10.1 P2MPD12 3 64 G3UA036 1000 P2MPD14 3 G3UA037 29.5 21.5 2.80 10.5 80 22 M3UF044 29.0 21.5 2.81 10.3 P2MPD12 3 48 16 G3UA036 33.0 24.8 3.17 P2MPD12 3 64 P2MPD16 3 64 P2MPD14 3 80 22 P2MPD16 3 96 P2MPD14 3 80 P2MPD16 3 96 22 P2MPD20 3 96 P2MPD20 3 112 26 P2MPD16 3 64 P2MPD16 3 96 P2MPD20 3 96 22 P2MPD20 3 112 26 G3UA037 M3UF044 1200 M3UF044 G3UA060 1400 33.0 35.5 32.2 42.0 39.0 43.5 24.8 26.6 24.5 31.5 28.0 32.6 3.17 3.17 3.28 3.82 3.86 3.85 12.2 11.2 12.4 11.2 10.1 10.1 G3UA061 43.5 32.6 3.85 12.4 M3UF052 41.0 30.0 3.83 10.7 G3UA060 P2MPD20 3 80 H1RC060 P2MPD20 3 96 22 G3UA060 P2MPD20 3 112 26 G3UA061 See Notes on Page 2 45.5 48.0 33.7 36.5 4.14 4.17 550.48-TG1Y G3UA061 48.0 36.5 4.17 M3UF052 44.0 32.0 4.31 11.7 10.2 1850 57.5 43.1 5.53 SOUND RATINGS HRC SOUND RATINGS BELS H1RC 018 8.0 024 8.0 030 8.0 036 8.2 042 8.2 048 8.4 060 8.4 CERTIFICATION APPLIES ONLY HEN USED ITH PROPER COMPONENTS AS LISTED ITH ARI Unitary Products Group 3

550.48-TG1Y CAPACITY - ith 90% Furnace and Coils RATED NET MBH K SEER # MBH CFM TOTAL SENS. TXV 1 EER 1 Phase HRC / UPFLO & S P2URD08 3 37 14 M3UF024 14.3 1.75 10.9 H1RC018 P2URD10 3 55 17 G3UA024 14.3 1.70 650 19.0 G1UA024S17 14.2 1.68 P2URD12 3 74 M3UF032 14.3 1.70 10.9 P2URD08 3 37 14 M3UF024 16.9 2.19 800 23.0 G3UA030 17.3 2.50 P2URD10 3 55 17 G1UA024S17 17.5 2.17 11.8 10.6 850 23.0 M3UF032 16.9 2.21 H1RC024 P2URD12 3 G3UA036 18.0 2.18 74 17 G1UA036S17 18.2 2.22 12.1 10.8 850 24.0 P2URD16 3 G1UA036S21 18.2 2.22 12.1 10.8 76 P2URD14 3 21 G3UA037 18.7 2.18 98 M3UF044 18.2 2.22 10.8 P2URD10 3 55 M3UF032 28.0 20.2 2.77 11.4 10.1 P2URD12 3 74 17 G3UA036 29.5 23.0 2.80 10.5 G1UA036S17 29.6 21.8 2.79 10.6 P2URD16 3 76 G1UA036S21 1000 29.6 21.8 2.79 10.6 P2URD14 3 98 G3AU037 29.5 23.0 2.80 10.5 21 M3UF044 29.0 21.5 2.81 10.3 30.2 22.4 2.77 12.2 10.9 P2URD12 3 74 17 G3UA036 33.0 24.8 3.17 G1UA036S17 33.0 24.7 3.13 10.6 P2URD16 3 76 G1UA036S21 33.0 24.7 3.13 10.6 G3UA037 1200 33.0 24.8 3.17 P2URD14 3 98 21 M3UF044 33.2 24.5 3.28 11.2 10.1 35.5 26.6 3.17 12.2 11.2 35.0 25.4 3.27 10.7 P2URD16 3 76 P2URD14 3 98 P2URD20 3 94 P2URD20 3 112 130 P2URD16 3 76 P2URD14 3 98 P2URD20 3 94 P2URD20 3 112 130 21 24 21 24 G3UA060 G1UA060S24 G3UA061 M3UF052 G3UA060 G1UA060S24 G3UA061 M3UF052 94 21 G3UA060 H1RC060 P2URD20 3 112 G1UA060S24 24 130 G3UA061 See Notes on Page 2 1400 1850 42.0 42.0 43.5 43.4 43.5 41.0 45.5 45.5 48.0 47.0 44.0 44.0 56.5 57.5 56.5 31.5 31.1 32.6 32.1 32.6 30.0 33.7 33.6 36.5 34.7 32.0 32.0 37.3 42.5 37.3 3.82 3.82 3.85 3.88 3.85 3.83 4.14 4.14 4.17 4.10 4.31 4.31 5.95 5.53 5.95 12.4 12.3 12.4 11.7 11.7 11.2 10.7 10.2 10.2 9.5 9.5 4 Unitary Products Group

CAPACITY - ith 78% Furnace and Coils RATED NET MBH K SEER # MBH CFM TOTAL SENS. TXV 1 EER 1 Phase HRC / UPFLO & S H1RC018 P1SPD10 40 17 G3UA024 19.0 14.4 1.7 650 G1UA024S17 19.0 14.2 1.7 P1SPD10 40 17 G1UA024S17 23.0 17.5 2.2 11.8 10.6 P1SPD10 40 17 G3UA036 24.0 18.0 2.18 12.2 40 17 H1RC024 P1SPD12 G1UA036S17 850 24.0 18.2 2.22 12.1 10.8 60 17 P1SPD16 60 20 G1UA036S21 24.0 18.2 2.22 12.1 10.8 80 20 G3UA037 24.0 18.7 2.18 12.2 P1SPD12 40 17 G3UA036 29.5 21.5 2.8 10.5 60 17 G1UA036S17 29.6 21.8 2.8 10.6 60 20 G1UA036S21 P1SPD16 G3UA037 80 20 30.2 22.4 2.8 12.2 10.9 1000 29.6 29.5 21.8 21.5 2.8 2.8 10.6 10.5 P1SPD12 40 17 G3UA036 33.0 24.8 3.2 60 17 G1UA036S17 33.0 24.7 3.1 10.5 60 20 G1UA036S21 P1SPD16 G3UA037 80 20 35.0 25.4 3.3 10.7 1200 33.0 33.0 24.7 24.8 3.1 3.2 10.5 P1SPD16 60 20 80 20 42.0 31.1 3.8 80 23 1400 42.0 31.5 3.8 P1SPD20 100 23 G1UA060S24 43.4 32.1 3.9 12.3 11.2 120 23 60 20 80 20 45.5 33.7 4.1 P1SPD16 80 23 45.5 33.6 4.1 100 23 120 23 H1RC060 P1SPD20 P1SPD20 See Notes on Page 2 80 23 100 23 120 23 80 23 100 23 120 23 G3UA060 G1UA060S24 G3UA060 G1UA060S24 1800 48.0 47.0 57.5 57.5 36.5 34.7 43.1 42.5 4.2 4.1 5.5 5.5 550.48-TG1Y CAPACITY - ith 78% Furnace and UF Coils ** RATED NET MBH K SEER # MBH CFM TOTAL SENS. TXV 1 EER 1 Phase HRC / UPFLO & S P1SPD10 40 17 40 17 M3UF032 23.0 17.3 2.21 P1SPD12 H1RC024 60 17 850 60 20 P1SPD16 M3UF044 24.0 18.2 2.22 10.8 80 20 60 20 M3UF032 28.0 20.2 2.77 11.4 10.1 P1SPD16 1000 80 20 M3UF044 29.0 21.5 2.81 10.3 60 20 P1SPD16 M3UF044 1250 33.2 24.5 3.28 10.1 80 20 See Notes on Page 2 Unitary Products Group 5

550.48-TG1Y CAPACITY - ith 80% Furnace and Coils # MBH 1 Phase HRC / HORIZONTAL & S H1RC018 P2HED12 40 ** 60 ** P1HDD12 47 ** 69 ** H1RC024 P2HED12 40 ** 60 ** P1HDD12 47 ** 69 ** P2HED12 40 ** 60 ** P1HDD12 47 ** 69 ** P2HED12 40 ** 60 ** P2HED16 80 ** 47 ** P1HDD12 69 ** P1HDD16 92 ** G3HC024 M3HD024 G3HC030 M3HD036 G3HC036 M3HD036 G3HC036 M3HD048 G3HC042 P2HED16 80 ** P2HED20 100 ** G3HC042 G3HC048 P1HDD16 92 ** M3HD048 P1HDD20 115 ** P2HED16 80 ** G3HC048 P2HED20 100 ** G3HC060 P1HDD16 92 ** M3HD048 P1HDD20 115 ** M3HD060 P2HED20 100 ** G3HC060 H1RC060 P1HDD20 115 ** M3HD060 1 Phase HRC/ HORIZONTAL AND S RATED CFM NET MBH K TOTAL SENS. 650 19 14.25 850 24.0 18.0 18.5 1.73 1.70 SEER TXV 1 2.24 1000 29.0 21.2 2.8 1200 1400 1850 33.0 35.0 35.0 41.0 42.0 41.5 45.5 48.0 45.0 48.0 57.5 57.5 24.8 26.3 26.3 30.8 31.5 31.1 33.7 36.5 33.3 36.5 43.1 43.1 3.27 3.18 3.13 3.90 3.89 3.88 4.14 4.18 4.13 4.25 5.53 5.48 11.8 11.8 0 0 0 0 H1RC018 P2MPD08 32 16 G3HC024 650 19.0 14.3 1.73 P2MPD12 48 16 G3HC024 650 19.0 15.0 1.73 H1RC024 P2MPD12 48 16 G3HC030 800 24.0 18.0 2.24 10.7 P2MPD14 80 22 G3HC036 1000 29.0 21.2 2.80 10.3 P2MPD14 80 22 G3HC036 33.0 24.8 3.14 10.5 1200 P2MPD16 64, 96 22 G3HC042 35.0 26.3 3.13 11.2 P2MPD16 64, 96 22 P2MPD14 80 22 G3HC042 41.0 30.8 3.90 10.5 1400 P2MPD20 80, 96 22 P2MPD20 112 26 G3HC048 42.0 31.5 3.89 10.8 P2MPD16 64, 96 22 G3HC048 45.5 33.7 4.14 P2MPD20 80, 96 22 G3HC060 48.0 36.5 4.18 G3HC048 45.5 33.7 4.14 P2MPD20 112 26 G3HC060 48.0 36.5 4.18 H1RC060 P2MPD20 80, 96 22 G3HC060 5.53 1850 57.5 43.1 P2MPD20 112 26 M3HD060 5.48 10.5 See Notes on Page 2. EER 11.2 10.7 10.3 10.5 11.2 10.5 10.8 10.7 10.9 10.5 6 Unitary Products Group

CAPACITY - ith 80% / 90% Furnace and Coils (continued) H1RC018 H1RC024 H1RC060 # MBH P2DPD10 48 P2CDD10 57 P2DPD08 48 P2CDD10 57 P2CDD12 64 P2DPD12 80 P2CDD12 80 P2DPD10 48 P2DPD12 64 P2DPD10 57 P2CDD10 57 P2CDD12 76 P2DPD12 64 P2DPD12 80 P2DPD16 80 P2CDD12 76 P2CDD16 97 P2DPD16 92 P2DPD16 80 92 P2CDD16 97 P2DPD16 80 P2DPD16 92 P2DPD20 104 P2DPD20 114 P2CDD16 97 P2DPD20 106 P2DPD20 114 P2CDD20 114 RATED NET MBH K CFM TOTAL SENS. 1 Phase HRC / DONFLO & S 16 16 16 G3CN030 M3CF032 G3CN030 M3CF032 G3CN030 M3CF032 650 850 1000 19.5 19.0 24.0 22.5 29.0 27.5 15.0 14.3 18.0 17.0 21.2 19.8 1.70 1.75 2.20 2.18 2.81 2.80 SEER TXV 1 11.4 EER 10.9 10.9 10.3 22 G3CN042 1200 35.0 26.3 3.18 22 26 G3CN042 G3CN060 M3CF044 G3CN060 M3CF052 1400 41.5 43.5 39.0 48.0 44.0 31.1 32.6 28.0 36.5 32.0 3.89 3.85 3.86 4.17 4.31 12.4 11.2 11.7 550.48-TG1Y 9.8 10.7 10.1 10.2 26 G3CN060 1800 57.5 43.1 5.53 Unitary Products Group 7

550.48-TG1Y CAPACITY - ith Variable Speed Furnaces (80%) OUTPUT RATED NET MBH SYSTEM SEER SEER MBH CFM TOTAL SENS. K /TXV 2 EER HRC / UPFLO S & S H1RC018 P2MPV12N 64 16 G3UA024 650 19.3 14.6 1.60 12.8 12.1 G3UA024 23.5 17.1 2.10 11.2 G2UT024 23.5 17.1 2.10 11.2 P2MPV12N 64 16 G3UA036 24.4 18.4 2.06 13.0 11.8 H1RC024 850 G2UT036 24.4 18.4 2.06 13.0 11.8 P2MPV14N 80 22 G3UA037 24.3 19.0 2.10 12.8 11.6 G2UT037 24.3 19.0 2.10 12.8 11.6 G3UA036 29.7 22.2 2.72 12.2 10.9 P2MPV12N 64 16 G2UT036 29.7 22.2 2.72 12.2 10.9 1000 G3UA037 29.8 22.2 2.70 12.3 P2MPV14N 80 22 G2UT037 29.8 22.2 2.70 12.3 G3UA036 33.0 24.8 3.17 P2MPV12N 64 16 G2UT036 33.0 24.8 3.17 1200 G3UA037 33.2 25.0 3.07 10.8 P2MPV14N 80 22 G2UT037 33.2 25.0 3.07 10.8 P2MPV20N 80 22 42.3 31.8 3.72 12.3 1400 G2UT048 42.3 31.8 3.73 12.3 45.7 33.9 4.04 12.2 P2MPV20N 80 22 G2UT048 45.7 33.9 4.04 12.2 G3UA060 48.3 36.8 4.07 12.7 11.8 H1RC060 P2MPV20N 80 22 G3UA060 57.8 45.0 5.43 12.2 10.6 1850 G2UA061 57.8 45.0 5.43 12.2 10.6 HRC / HORIZONTAL S & S H1RC018 P2MPV12N 64 16 G3HC024 650 19.3 14.6 1.63 12.6 11.8 H1RC024 P2MPV12N 64 16 G3HC030 850 24.4 18.4 2.12 12.7 P2MPV12N 64 16 G3HC030 29.2 23.2 2.73 12.3 10.7 1000 P2MPV14N 80 22 G3HC036 29.3 21.5 2.72 12.2 10.8 P2MPV14N 80 22 5 G3HC036 33.3 25.0 3.04 1200 G3HC042 35.3 25.0 3.04 12.3 11.6 P2MPV20N 80 22 G3HC042 41.1 31.0 3.86 12.1 10.6 1400 G3HC048 42.3 32.3 3.79 12.2 11.2 P2MPV20N 80 22 G3HC048 45.7 34.0 4.07 12.2 11.2 H1RC060 P2MPV20N 80 22 G3HC060 1850 57.8 45.0 5.43 12.2 10.6 See Notes on page 2, plus Notes below: N/A = Rating does not apply. TXV factory installed in coil. 5 Horizontal coil width is larger than furnace supply air opening width. Field transition is required. 8 Unitary Products Group

PERFORMANCE H1RC018 H1RC024 SUCT. T/P AIR TEMP ON CONDENSER SUCT. T/P AIR TEMP ON CONDENSER @ COMPR. 75 F 95 F 115 F @ COMPR. 75 F 95 F 115 F TEMP. PSIG MBH K MBH K MBH K TEMP. PSIG MBH K MBH K MBH K 35 61.5 16.84 1.43 13.61 1.58 9 1.69 35 61.5 35.94 3.12 31.92 3.76 27.86 4.54 40 68.5 18.39 1.44 15.48 1.62 13.25 1.76 40 68.5 39.29 3.15 35.11 3.77 30.80 4.55 45 76.0 20.06 1.46 17.34 1.65 14.73 1.82 45 76.0 42.48 3.21 38.17 3.84 33.70 4.63 50 84.0 21.54 1.47 19.20 1.69 16.47 1.88 50 84.0 45.62 3.23 41.40 3.92 36.56 4.39 35 61.5 20.81 1.86 16.82 2.06 14.07 2.20 35 61.5 39.75 3.32 35.31 3.99 30.82 4.81 40 68.5 22.73 1.88 19.13 2.11 16.37 2.29 40 68.5 43.46 3.34 38.84 4.00 34.08 4.83 45 76.0 24.80 1.90 21.43 2.15 18.20 2.37 45 76.0 46.99 3.40 42.23 4.07 37.28 4.91 50 84.0 26.63 1.91 23.73 2.20 20.36 2.44 50 84.0 50.47 3.43 45.80 4.16 40.44 4.66 35 61.5 26.13 2.39 21.13 2.65 17.67 2.83 35 61.5 50.26 4.42 44.64 5.32 38.97 6.42 40 68.5 28.55 2.41 24.02 2.71 20.56 2.98 40 68.5 54.95 4.46 49.10 5.33 43.08 6.44 H1RC060 45 76.0 31.14 2.44 26.71 2.77 22.86 3.02 45 76.0 59.41 4.54 53.38 5.43 47.13 6.55 50 84.0 33.44 2.45 29.80 2.83 25.57 3.14 50 84.0 63.81 4.58 57.90 5.55 51.13 6.22 35 61.5 29.20 2.70 23.61 2.99 19.75 3.19 40 68.5 31.90 2.72 26.84 3.06 22.98 3.32 45 76.0 34.80 2.75 30.07 3.12 25.54 3.43 50 84.0 37.36 2.77 33.30 3.19 28.57 3.54 NOTES: 1. For condensing unit only. Does not include effect of evaporator motor power or heat. 2. Performance based on 15 superheat and 15 sub-cooling at condensing unit. a. Increase capacity 1% for each 2 increase in sub-cooling. b. Decrease capacity 1% for each 2 decrease in sub-cooling. 3. Sub-cooling in excess of 20 may result in excessively high condensing temperature with air on condenser above 115. Maximum recommended condensing temperature is 140 F. 550.48-TG1Y Unitary Products Group 9

550.48-TG1Y DIMENSIONS All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. A C HRC REFRIGERANT DIMENSIONS CONNECTION LINE SIZE A 1 B C LIQUID VAPOR 018 19 35 23 024 19 35 23 3 4 030 25 35 23 036 27 37 27 3 8 042 29 37 27 7 8 048 29 37 27 060 39 37 27 1 1 8 1 Includes fan guard B PHYSICAL AND ELECTRICAL DATA - (1 Phase) H1RC018 H1RC024 H1R060C SUPPLY VOLTAGE 208/230-1-60 NORMAL VOLTAGE RANGE 1 187 to 252 MIN. CIRCUIT AMPACITY 11.7 14.1 17.4 19.4 25.0 28.2 37.4 MAX. OVERCURRENT DEVICE AMPS 2 20 20 25 30 35 40 60 COMPRESSOR TYPE INERTIA INERTIA INERTIA INERTIA INERTIA INERTIA SCROLL COMPRESSOR AMPS RATED LOAD 9.0 10.9 13.5 14.8 19.2 21.8 28.9 LOCKED ROTOR 48 60 75 81 87 105 169 CRANKCASE HEATER NO NO NO NO NO NO NO FAN MOTOR AMPS RATED LOAD 0.5 0.5 0.5 0.9 0.9 0.9 1.3 MIN. FIELD IRE SIZE AG 60 C COPPER CONDUCTORS 14 12 12 12 10 10 8 MAX. IRE LENGTH FEET BASED 208V 100 130 105 100 120 105 123 ON 3% VOLTAGE DROP 230V 110 145 118 105 130 115 136 FAN DIAMETER INCHES 18 18 18 22 22 22 22 RATED HP 1/12 1/12 1/12 1/6 1/6 1/6 1/4 FAN MOTOR NOMINAL RPM 1,100 1,100 1,100 830 830 830 830 NOMINAL CFM 1,850 1,850 1,850 3,300 3,300 3,300 3,450 FACE AREA SQ. FT. 9.15 9.15 8 15.72 17.03 17.03 23.58 ROS DEEP 1 1 1 1 1 1 1 FIN / INCH 18 18 18 18 18 18 18 LIQUID LINE OD 3/8 3/8 3/8 3/8 3/8 3/8 3/8 VAPOR LINE OD 3/4 3/4 3/4 3/4 7/8 7/8 1-1/8 CHARGE (LBS-OZ) 3 4-3 4-12 4-12 6-2 6-9 7-10 10-7 CHARGE PER FOOT, OZ 0.68 0.68 0.68 0.68 0.70 0.70 0.76 OPERATING EIGHT, LBS. 123 131 148 157 178 184 198 1 Utilization range A in accordance with ARI standard 110. 2 Dual element fuses or HACR circuit breaker. 3 The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant calculated, using the difference in length multiplied by the per foot value. 10 Unitary Products Group

ACCESSORIES Refer to Price Manual for specific model numbers. Compressor Blanket - Designed to further reduce the normal operating sound and is required to meet Canadian sound levels for units of three tons and below. Stub Adapters - Available to adapt sweat connect units to quick connect coils or sweat connect coils to quick connect units. Precharged Line Sets - Available in 15, 25, 35 and 50 foot lengths for connection of quick connect models. Outdoor liquid ends have F-6 connectors, vapor ends have F-11 connectors. Indoor liquid ends have M-6 connectors, vapor ends have M-11 connectors. All indoor vapor ends are provided with a 90 bend. A 30 foot line set with straight ends is available for splicing to other lines for longer runs. All vapor lines are insulated with 1/2 sponge rubber. Blower Time Delay - Available to increase efficiency when installed. Installs on indoor section and maintains blower for approximately one minute after cooling thermostat has been satisfied. Hard Start Kit (Single Phase Units) - provides required starting torque for used with thermal expansion valve. 550.48-TG1Y Outdoor Thermostat - 2TD06700124 - Consists of an adjustable outdoor thermostat and relay in a vented enclosure. It provides additional second stage control of the supplemental resistance heat. (balance point control) Room Thermostats - One of the following thermostat may be used with these systems. 2ET07700324 - Programmable electronic 1H/1C Manual change over. 2TH07700124 - One Stage Heat / One Stage Cool, manual changeover, non-programmable TXV Kit - Must be used to obtain system performance. Not required with GHT or GUT coils which have TXV factory installed. Model Kit Req d. Model Kit Req d. H1RC018 1TV0601 1TV0602 H1RC024 1TV0601 1TV0603 1TV0602 1TV0603 H1RC060 1TV0604 TYPICAL INSTALLATION - HRC018 THRU 060 60" OVERHEAD CLEARANCE 18" SERVICE ACCESS CLEARANCE EATHERPROOF DISCONNECT SITCH THERMOSTAT TO OR AIR HANDLER TERMINAL BLOCK NEC CLASS 1 IRING NEC CLASS 2 IRING 10" CLEARANCE AREA TO INDOOR SEAL OPENING(S) ITH PERMAGUM OR EQUIVALENT CONTROL ACCESS PANEL NOTE: ALL OUTDOOR IRING MUST BE EATHERPROOF TYPICAL FIELD IRING ALL FIELD IRING TO BE IN ACCORDANCE ITH NATIONAL ELECTRICAL CODE (NEC) AND/OR LOCAL CODES POER IRING 208/230-1-60 24 VOLT CONTROL IRING OR AIR HANDLER TERMINAL BLOCK C Y R G POER CONTROL FACTORY CONTACTOR TERMINALS GROUND SCRE HRC CONDENSING * Y R G * Terminal is only required on systems with heat. ROOM THERMOSTAT ALL OUTDOOR IRING MUST BE EATHERPROOF. USE COPPER CONDUCTORS ONLY. Unitary Products Group 11

MATCHING INDOOR COMPONENTS Add-On Coils - For Furnace Application Typical Applications ➀ UPFLO M3UF 3 6 ➀ UPFLO G1UA, G3UA or G2UT 1 2 4 5 ➂ HORIZONTAL M3HD Air Handlers - For Non-Furnace Application F1RC or F1RP FAN S ➁ DONFLO G3CN ➁ DONFLO G3CF N1VS, N2AH N4AH or N1FA, N3FA BLOER G3HC or G1FC ➃ UPFLO ➅ HORIZONTAL ➃ UPFLO ➄ DONFLO ➅ HORIZONTAL Unitary Products Group P.O. Box 1592, York, Pennsylvania USA 17405-1592 Subject to change without notice. Printed in U.S.A. Copyright by York International Corporation 1996. All Rights Reserved. 550.48-TG1Y Supersedes: 550.48-TG1Y (1095)