LEAKSTOPPER RANGE Multizone water leak detection systems

Similar documents
LEAKSTOPPER 1 Single zone water leak detection system

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

DCS-100. intelligent damper control & monitoring system

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Leak Detection and Flood Prevention

DMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual

Excel-EN Conventional Fire Control Panel

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

CONTENTS NBM-06 Bell (6") Page 1

Intelligent Security & Fire Ltd

Silent Alert Fire Safe System

New Silent Alert Fire Safe System

Accessible Toilet Alarm

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

BC3250. Blowdown Controller

Public Safety DAS Annunciator Panel

Application, Installation, Operation & Maintenance Manual

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

WARNING FIRE DOOR CLOSING

MINERVA MZX125 Digital Addressable Fire Detection System

An introduction to... Sigma

Installation and user manual for the BiWire / Conventional Repeater Panel

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Excellence in Level Measurement

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

Operation and Maintenance Manual

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Disabled Persons Toilet Alarm Kit

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

The complete conventional fire warning system

"ESDDR" Series Electric Humidifier

2G & 3G GSM Wireless Beam Alarm

Multi-Gas-Controller MGC2

Fire detection and alarm

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Installation, Operating and Maintenance Manual

HYTEK ATEX APPROVED TANK ALARM

TECHNICAL DATA OBSOLETE

FSTP2-2-wire 2 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS2 Issue 01 April 2012

Intelligent addressable fire alarm control panel

Centro-Matic Automated Lubrication Systems System Controls

ALARMLINE ANALOGUE Linear Heat Detection System

FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual

MINERVA MZX125. Digital Addressable Fire Detection System

Please do not hesitate to contact us with any enquiries.

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

FEC400 Series. Installation Manual

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

INPUT / OUTPUT MINI MODULES

2G & 3G GSM Door Contact Alarm

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

FSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS4 Issue 01 April 2012

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS)

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

D3 Wireless temperature alarm & monitoring system family. tek-troniks


AT10.1 Series Microprocessor-Controlled Float Battery Charger (single phase input)

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

Instructions for the fan motor control system with integrated wiring terminals SILVER C

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

Alarm Panel Operating Instructions

Power Flame Incorporated

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Solution F2. Fire Alarm Control Panels one step ahead.

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Instructions for the fan motor control system, SILVER C

Installation Instructions for W2H Series Signals

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Smoke Vent Control Panel PCB4 V4 Installation Manual

HEATFAST HF9101-V1 AMBIENT SENSING TRACE HEATING THERMOSTAT

DIESEL Engine Fire Pump Controllers Features

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

Operating Instructions. For. Alarm Control Module. Model SSR 500

Conventional Fire Control Panel

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

INSTALLATION MANUAL SOUNDER MODELS RIALTO L LS X LSX TRIADE L LS QL QLS LIDO L X LS LSX

CONDENSATE MANAGEMENT SYSTEMS

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

Addressable and Conventional Fire Protection

EXTINGUISHING AGENT RELEASE MODULE

Consumer Products Catalog

Flostop TS D7E and A8E. Operation Manual

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

Installation Instructions 4 Zone Fire Panel

Fratech Multipath-IP

APM110 LOW AIR VELOCITY ALARM

Transcription:

LEAKSTOPPER RANGE Multizone water leak detection systems WHAT DOES THE PRODUCT DO? The LeakStopper detects water leaks and instantly triggers an alarm to warn you. It is capable of monitoring between 2 and 64 (more if required) areas simultaneously. If more than one of these areas has a leak, the LeakStopper can show this. HOW DOES IT WORK? Each zone on the alarm panel can be connected to a water detection sensor. This can be a sensor tape, a probe, an in-line sensor or a pad. Should water touch any of these, it will signal the panel to set off an alarm. Using a multizone panel allows a number of different areas or a large area to be defined into zones. Should a leak occur in any of these, the LeakStopper will indicate where it is. HOW DOES IT DETECT WATER? Water (unless purified) contains contaminants such as ions and salts and it s these within the water that are conductive. The sensors (conductors) used for leak detection are separated by a carrier and the water acts as a path for a very low electrical signal to pass from one to the other. It is this action that triggers the alarm. WHAT OUTPUTS ARE AVAILABLE? 3 X 2 amp Volt free changeover common alarm relay. Will switch state on any zone detecting an alarm. Useful for connection to an external sounder/beacon, for switching on a pump or triggering a SMS text dialler. Ideal for connection to a BMS. 2 amp individual zone relays (2 per zone) will switch only when a particular zone detects a leak. Ideal for connection to valves on water supplies. 12VDC output for running low voltage devices directly from the panel up to 500mA. Power fail relay will switch should the mains power be interrupted. Output connector for Echo repeater panel used for remote monitoring in a different location to the main panel location. Sensor Types: Sensor Tape: Available in 1m, 2m, 3m, 5m and 10m lengths. Plug and socket connections mean any length can be made up by simply connecting the various cable lengths together. Sensor Probe: Adjustable height from the floor between 0 and 25mm. Protective cover helps stop accidental damage. Multiple sensors can be linked in series to cover large areas. Sensor Pad: Ideal for placing in drip trays, under shower trays etc. Little bigger than a matchbox, these sensors can be linked together in series. Inline Tee Sensor: perfect for putting in the overflow pipes to detect and signal an alarm if a tank becomes too full.. Intelli-Probe: Used when the distance from the alarm panel is over 100m. can be configured as a junction box to plug in sensor tape, a probe or to connect a sensor pad to.. www.envirotechalarms.com 0330 1595933 enquiries@envirotechalarms.com

LEAKSTOPPER SPECIFICATION Zones 2, 4, 8, 16, 32, 64 + Input Voltage 230VAC (5W) Outputs 3 x common alarm volt free relays + individual zone relays IP Rating 65 Maximum Coverage per Zone 100m (more when Intelli-Probe is used) Cable Rating (to sensors) 4 core 0.22mm² conductor Valve Compatibility 12VDC and 230VAC Solenoid Type Battery Backup 20 hours standby mode Typical Configuration Beacon/ Sounder LeakStopper 4 (4 zone alarm panel) Zone 1 Zone 2 Zone 3 Zone 4 Solenoid Valves (one per zone) Optional Extras Telephone Diallers Available as a landline or SMS text message system. Programmable telephone numbers. Editable messages to inform recipient what area the leak has occurred. Valves Available with BSP female s c r e w f i t t i n g s i n (1/2 )15mm, (3/4 ) 22mm, (1 ) 25mm, (1 1/4 ) 30mm, (1 ½ ) 40mm and (2 ) 50mm 1 / 2 a n d 3 / 4 W R A S approved solenoid valves. 230VAC and 12VDC options Sounder/Beacon Super bright amber beacon Load sounder Triggered when an alarm is detected by the master alarm panel Easily installs to panel with a single plug in connector Echo Repeat Panel Simulates an alarm from an alarm panel located in a different part of the building. Can be located in a reception or security area where people are present. Sounder and LED light output. Powered directly from the main alarm panel.

LEAKSTOPPER MULTIZONE RANGE Product Overview: The LeakStopper Multizone is a range of water leak detection alarm panels designed to notify that a leak has occurred and where it is. Available in any size between 2 and 64 + zones, each alarm panel has the capability to connect to sensor tape, sensor probes and/or sensor pads. The LeakStopper Multizone has individual zone relays and a battery back up as standard as well as common alarm relays. MAIN FEATURES: 100m of cable per zone (more if Intelli-Probe is used) Adjustable sensitivity for every zone Visual alarm output for each zone Sensor fault monitoring 2 x volt free relay contacts per zone Connection to BMS and valves Inbuilt audible alarm output Auto resets after leak has been dried out Supply Voltage: Self sensing 120VAC to 240VAC 40-60Hz +/- 15% SMPSU Supply Current: 3A max Current burden on standby: 35 Watts @ 230Vac +/-15% Alarm Relay: Contact rating: Fault Relay: Power Fault Relay: Contact rating: PER ZONE Alarm Relay: Contact rating: Each Sensors Inputs: Sensor Types: Maximum Cable Length: Alarm LED : Fault/Healthy: Alarm Hysteresis: Audible alarm output: Electrical Connections: DPCO volt free contact 2A@250Vac resistive SPCO volt free contact 1A@50Vac resistive (signal only NOT MAINS VOLTAGE) SPCO volt free contact 2A@250Vac resistive DPCO volt free contact 2A@250Vac resistive One set of terminals (each can take more than one sensor) terminated with a signal diode Sensor Cable, Probe Sensors, Pad Sensors, In-line sensor, Intelli-Probe Sensor 100m combined link connector cable to sensor cable per zone 5mm Flashing Red. 1 for each zone LED: 5mm TRI colour. Green zone healthy & Red zone fault Detects between 3K ohms & 20K ohms dependant on the sensitivity adjustment potentiometer 80db@10cm continuous tone All un-pluggable terminals sized 0.5-2.5mm2 cable

Housing Material: The housing is grey ABS with hinged lid. The door is lockable by six screws Dimensions (3 to 8 zones): 285mm high, 235mm wide and a depth of 105mm. Dimensions (9 to 32 zones): 600mm high 300mm wide and a depth of 132mm Dimensions (33 to 64 zones): 1200mm high 600mm wide and a depth of 132mm. Ambient Range: -10 to +50deg C, 0-90% RH condensing Battery Charge voltage: 13.6Vdc float charge sealed lead. Battery run time standby: 20 hours @ full charge dependant on condition. Country of Origin: U.K. Typical connections (LeakStopper 4 Panel shown as example): Common Alarm Relay x 2 240volt 8 amp Echo Repeat Panel Open Collector RED = +12v dc YEL = open collector BK = 0V dc Mains 230VAC L. E. N Cable Fault Relay Output 5 volt DC output Individual zone relays (2 per zone) 240volt 2 amp 12 volt DC output Sensor Connections Battery Red+ Black- Sensitivity Adjustment Mains Fail Relay Com and NO more sensitive less Installation: Mounting; The LeakStopper Multizone range of alarm panels have been designed to be surface mounted and are fixed to a wall using appropriate screws and wall fixings. Cable entry can be back, bottom, top or side entry using appropriate cable glands. Electrical Supply; A 2 amp fused spur is required adjacent to the panel in order to power it. Sensitivity adjustment; Less sensitivity may be needed on longer cable runs, each zone has independent adjustment. Testing; Wet test - this is achieved using a wet cloth placed onto the sensor tape/probe/pad to simulate a water leak (note: the sensor will need to dry before alarm will reset). Dry test - achieved using a conductive material such as silver cooking foil wrapped around the tape/probe/pad.

SensorTape Product Overview: The sensor tape used with the LeakStopper water leak detection alarms has been specifically designed to detect the presence of water. Category Type: 4C Sensor Cable Orange Conductor Material: Stainless steel wire Conductor Diameter: 0.40mm x 2 Insulation Material: PVC Insulation Diameter: 1.8mm(+/-0.10mm) x 4 twisted Compliant: Voltage rating: RoHS2 (2011/65/EU) -20 C to +80 C 5Volts @ 10 Milliamps Cross section: Conductors Carriers 4mm Connectors: Plug Socket Screw Lock Screw Lock

Sensor Probe Product Overview: The sensor probe is a height adjustable water leak detection sensor for use in areas susceptible to leaks. It s contained in a rigid plastic housing to offer protection against possible damage. The floor brackets allow for vertical adjustment of the sensor height from the floor. This is particularly useful if the probes are used in an environment where a small amount of liquid is permissible due to a manufacturing or cleaning process. Enclosure: Enclosure dimensions: Enclosure rating: Height Adjustment: Probe Material: Probe Diameter: Voltage at probe: High impact ABS plastic, 2.5mm thick, lid and base incorporates tongue and groove sealing system with neoprene gasket. Lid fixing screws are M4 stainless steel. 82mm x 80mm x 55mm IP65 and NEMA4 (dust and hose proof) 0mm to 25mm Stainless steel 3mm 5 volts @ 10 micro amps -10 C to +40 C Height adjusted to 25mm Height adjusted to 0mm Connection Block

Sensor Pad The sensor pad is ideal for using in the drip trays of equipment where water is produced by process of condensation. Typically used where air cooling is fundamental to keeping an environments temperature stable such as data centres or comms rooms. This low profile sensor can be simply placed face down in the drip tray under an AHU or CRAC unit. A number of pads can be connected in series to allow several drip trays to be monitored by a single alarm panel or one zone of a multizone panel. Enclosure: Enclosure dimensions: Pad Material: Pad Dimensions: Voltage at probe: ABS 55mm x 55mm x 40mm Tinned Copper 55mm x 55mm 5 volts @ 10 micro amps -10 C to +40 C Typical Installation:

Inline Tee Sensor Probe The tee sensor has been designed to go into the over flow pipes on break tanks, toilet cistern and header tanks. The sensor is located inside the tee piece and gets installed on the overflow pipe with the sensor at the bottom. Any water that travels down the pipe and into the tee sensor will make contact with the conductors of the sensor and set off the alarm. Tee Piece: Tee Piece Sizes: Tee Piece Materials: Probe Material: Probe Diameter: Voltage at probe: Speed-fit plumbing fitting 15mm, 22mm, 28mm (other sizes are available) Plastic or Brass Stainless steel 3mm 5 volts @ 10 micro amps -10 C to +40 C Typical Installation: Float operated valve Overflow pipe with tee sensor Stop valve Break tank Solenoid valve Pump set

Intelligent Sensor Junction Box Product Overview: This is a microprocessor controlled intelligent sensor designed to detect water leaks. The internal processor continuously analyses the environment for the presence of water and on detection triggers an alarm. In this instance, the onboard LED will switch from Green (all healthy) to Red and an internal relay will switch that can be used to signal back to an Envirotech Alarms master panel. It has been designed to work as a stand alone sensor or for installations where there are very long cable runs. Input voltage: Current consumption: Enclosure: Enclosure dimensions: Enclosure rating: Height Adjustment: Sensor Type: Max cable run length: Relay Contact: Voltage at probe: 6VDC to 30VDC (can be powered directly from the main alarm panel) 24VDC (30mA max and 5mA on standby) High impact ABS plastic, 2.5mm thick, lid and base incorporates tongue and groove sealing system with neoprene gasket. Lid fixing screws are M4 stainless steel. 82mm x 80mm x 55mm IP65 and NEMA4 (dust and hose proof) 0mm to 25mm Probe/tape/pad 600m 1 amp 50 VDC 5 volts DC @ 10 micro amps -10 C to +40 C + positive 6V to 30VDC - negative 0VDC Normally Closed Common Normally Open Volt free changeover relay Sensor Tape Input www.envirotechalarms.com 0330 1595933 enquiries@envirotechalarms.com