LEAKSTOPPER 1 Single zone water leak detection system

Similar documents
LEAKSTOPPER RANGE Multizone water leak detection systems

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Excel-EN Conventional Fire Control Panel

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

Leak Detection and Flood Prevention

DMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual

DCS-100. intelligent damper control & monitoring system

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Installation and user manual for the BiWire / Conventional Repeater Panel

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Intelligent Security & Fire Ltd

Accessible Toilet Alarm

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Silent Alert Fire Safe System

CONTENTS NBM-06 Bell (6") Page 1

HYTEK ATEX APPROVED TANK ALARM

New Silent Alert Fire Safe System

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Multi-Gas-Controller MGC2

The complete conventional fire warning system

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Excellence in Level Measurement

BC3250. Blowdown Controller

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

Installation, Operating and Maintenance Manual

Public Safety DAS Annunciator Panel

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS)

EXTINGUISHING AGENT RELEASE MODULE

Installation, Operation and Maintenance Manual

Application, Installation, Operation & Maintenance Manual

Disabled Persons Toilet Alarm Kit

ANALOX 3000 Carbon Monoxide Monitor

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

OPERATION AND INSTALLATION MANUAL

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Operation and Maintenance Manual

WARNING FIRE DOOR CLOSING

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Product Data Sheet. Merlin GDP2. Gas Safety Products. Merlin GDP2. Installation, operating and maintenance 23/08/2016. S&S Northern Ltd 1

Fire detection and alarm

Centro-Matic Automated Lubrication Systems System Controls

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

CW9000 Wireless Fire System. Installation Manual

CONDENSATE MANAGEMENT SYSTEMS

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2

Addressable and Conventional Fire Protection

Alarm Panel Operating Instructions

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

Installation Instructions 4 Zone Fire Panel

PANTHER. Condensate removal pump Installation and operating guide

OPERATION / INSTALLATION

An introduction to... Sigma

900 Quadrant Steam Shower Cabin with 6 Body Jets

FEC400 Series. Installation Manual

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

TECHNICAL DATA OBSOLETE

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

FSTP2-2-wire 2 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS2 Issue 01 April 2012

ALARMLINE ANALOGUE Linear Heat Detection System

D3 Wireless temperature alarm & monitoring system family. tek-troniks

"ESDDR" Series Electric Humidifier

DIESEL Engine Fire Pump Controllers Features

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

APM110 LOW AIR VELOCITY ALARM

Brivis Service Manual

2G & 3G GSM Wireless Beam Alarm

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

DISABLED TOILET / EMERGENCY ASSISTANCE ALARMS

Technical Specification

2G & 3G GSM Door Contact Alarm

aquilar - leak detection solutions

4 wire conventional alarm system

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

SIL725 Safety Annunciator

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

EFBW series - BiWire Ultra control panel

ACCURATE ELECTRONICS INC

Conventional Fire Detection

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Power Flame Incorporated

FSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS4 Issue 01 April 2012

Smoke Vent Control Panel PCB4 V4 Installation Manual

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

System 800 Addressable Fire Detection & Alarm System

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Transcription:

LEAKSTOPPER 1 Single zone water leak detection system WHAT DOES THE PRODUCT DO? The LeakStopper 1 detects the presence of water in environments where it is not supposed to be. Should water be detected the alarm panel will trigger an internal buzzer and an LED will start to flash. There are also a number of volt free relays that will switch when water has been detected. HOW DOES IT WORK? Water (unless purified) contains contaminants such as ions and salts and it s these within the water that are conductive. The sensors (conductors) used for leak detection are separated by a carrier and the water acts as a path for very low electrical signal to pass from one to the other. It is this action that triggers the alarm. 187mm Sensor Types (examples): 122mm WHAT OUTPUTS ARE AVAILABLE? 3 X 2 amp Volt free changeover common alarm relay. Will switch state on detecting an alarm. Perfect for connection to a BMS, an external sounder/beacon, for switching on a pump or triggering a telephone dialler. 12VDC output for running low voltage devices directly from the panel. Power fail relay will switch should the mains p o wer be interrupted. Output connector for Echo repeater panel used for remote monitoring in a different location to the main panel location. Mute button - silences the panel after an alarm has been triggered as well as used to reboot the panel should a fault occur. Onboard LED outputs for System Healthy, Power On, Water Leak Detected, Line Fault and Power Fail. Sensitivity adjustment allows the system to be set according to the environment it s installed in. 12VDC 1.2 ah Battery back up 20 hours in standby mode. Sensor Tape: Available in 1m, 2m, 3m, 5m and m lengths. Plug and socket connections mean any length can be made up by simply connecting the various cable lengths together. Sensor Probe: Adjustable height from the floor between 0 and 25mm. P ro tective cover h e l p s stop accidental damage. Multiple sensors can be linked in series to cover large areas. Sensor Pad: Ideal for placing in drip trays, under shower trays etc. Little bigger than a matchbox, this sensor can be linked together in series. Inline Sensor: perfect for putting in the overflow pipes to detect and signal an alarm if a tank becomes too full.. www.envirotechalarms.com 01249 659588 enquiries@envirotechalarms.com

LEAKSTOPPER SPECIFICATION Zones 1 Input Voltage 230VAC (5W) Outputs 3 x common alarm volt free relays + individual zone relays IP Rating 65 Maximum Coverage per Zone 0m (more when Intelli-Probe is used) Cable Rating (to sensors) 4 core 0.22mm² conductor Valve Compatibility 12VDC and 230VAC Solenoid Type Battery Backup 20 hours standby mode Typical Configuration LeakStopper 1 (Single zone alarm panel) Solenoid Valve Optional Extras Telephone Diallers Available as a landline or SMS text message system. Programmable telephone numbers. Editable messages to inform recipient what area the leak has occurred. Valves Available with BSP female s c r e w f i t t i n g s i n (1/2 )mm, (3/4 ) 22mm, (1 ) 25mm, (1 1/4 ) 30mm, (1 ½ ) 40mm and (2 ) 50mm 1 / 2 a n d 3 / 4 W R A S approved solenoid valves. 230VAC and 12VDC options Sounder/Beacon Super bright amber beacon Load sounder Triggered when an alarm is detected by the master alarm panel Easily installs to panel with a single plug in connector Echo Repeat Panel Simulates an alarm from an alarm panel located in a different part of the building. Can be located in a reception or security area where people are present. Sounder and LED light output. Powered directly from the main alarm panel.

LEAKSTOPPER 1 RANGE Product Overview: The LeakStopper 1 is a water leak detection alarm panel designed to notify that a leak has occurred. Each alarm panel has the capability to connect to sensor tape, sensor probes and/or sensor pads. The LeakStopper 1 has 3 output relays and a battery back up as standard. MAIN FEATURES: 0m of cable per zone (more if Intelli-Probe is used) Adjustable sensitivity for every zone Visual alarm output for each zone Sensor fault monitoring 3 x volt free relay contacts Connection to BMS and valves Inbuilt audible alarm output Auto resets after leak has been dried out Supply Voltage: Self sensing 120VAC to 240VAC 40-60Hz +/- % SMPSU Supply Current: 3A max Current burden on standby: 35 Watts @ 230Vac +/-% Alarm Relay: Contact rating: Fault Relay: Power Fault Relay: Contact rating: PER ZONE Alarm Relay: Contact rating: Each Sensors Inputs: Sensor Types: Maximum Cable Length: Alarm LED : Fault/Healthy: Alarm Hysteresis: Audible alarm output: Electrical Connections: DPCO volt free contact 2A@250Vac resistive SPCO volt free contact 1A@50Vac resistive (signal only NOT MAINS VOLTAGE) SPCO volt free contact 2A@250Vac resistive DPCO volt free contact 2A@250Vac resistive One set of terminals (each can take more than one sensor) terminated with a signal diode Sensor Cable, Probe Sensors, Pad Sensors, In-line sensor, Intelli-Probe Sensor 0m combined link connector cable to sensor cable 5mm Flashing Red. 1 for each zone LED: 5mm TRI colour. Green zone healthy & Red zone fault Detects between 3K ohms & 20K ohms dependant on the sensitivity adjustment potentiometer db@cm continuous tone All un-pluggable terminals sized -2.5mm2 cable

Housing Material: The housing is grey ABS with hinged lid. The door is lockable by six screws Dimensions (3 to 8 zones): 285mm high, 235mm wide and a depth of 5mm. Dimensions (9 to 32 zones): 600mm high 300mm wide and a depth of 132mm Dimensions (33 to 64 zones): 1200mm high 600mm wide and a depth of 132mm. Ambient Range: - to +50deg C, 0-90% RH condensing Battery Charge voltage: 13.6Vdc float charge sealed lead. Battery run time standby: 20 hours @ full charge dependant on condition. Country of Origin: U.K. Connections (LeakStopper1 Panel): Mains 230VAC N. E. L Battry Fuse 1 amp Voltage adjustment potentiometer 13.6VDC Echo Repeat Panel Open Collector RED = +12v dc YEL = open collector BK = 0V dc Power fail relay 240volt 2 amp 12 volt DC output Battery Sensitivity Adjustment more sensitive less Additional relays x2 240volt 8 amp Cable Fault Relay Output Sensor Connections + / - Installation: Mounting; The LeakStopper 1 alarm panel has been designed to be surface mounted and are fixed to a wall using appropriate screws and wall fixings. Cable entry can be back, bottom, top or side entry using appropriate cable glands. Electrical Supply; A 2 amp fused spur is required adjacent to the panel in order to power it. Sensitivity adjustment; Less sensitivity may be needed on longer cable runs, each zone has independent adjustment. Testing; Wet test - this is achieved using a wet cloth placed onto the sensor tape/probe/pad to simulate a water leak (note: the sensor will need to dry before alarm will reset). Dry test - achieved using a conductive material such as silver cooking foil wrapped around the tape/probe/pad.

SensorTape Product Overview: The sensor tape used with the LeakStopper water leak detection alarms has been specifically designed to detect the presence of water. Category Type: 4C Sensor Cable Orange Conductor Material: Stainless steel wire Conductor Diameter: 0.40mm x 2 Insulation Material: PVC Insulation Diameter: 1.8mm(+/-0.mm) x 4 twisted Compliant: Temperature rating: Voltage rating: RoHS2 (2011/65/EU) -20 C to + C 5Volts @ Milliamps Cross section: Conductors Carriers 4mm Connectors: Plug Socket Screw Lock Screw Lock

Sensor Probe Product Overview: The sensor probe is a height adjustable water leak detection sensor for use in areas susceptible to leaks. It s contained in a rigid plastic housing to offer protection against possible damage. The floor brackets allow for vertical adjustment of the sensor height from the floor. This is particularly useful if the probes are used in an environment where a small amount of liquid is permissible due to a manufacturing or cleaning process. Enclosure: Enclosure dimensions: Enclosure rating: Height Adjustment: Probe Material: Probe Diameter: Voltage at probe: Temperature rating: High impact ABS plastic, 2.5mm thick, lid and base incorporates tongue and groove sealing system with neoprene gasket. Lid fixing screws are M4 stainless steel. 82mm x mm x 55mm IP65 and NEMA4 (dust and hose proof) 0mm to 25mm Stainless steel 3mm 5 volts @ micro amps - C to +40 C Height adjusted to 25mm Height adjusted to 0mm Connection Block

Sensor Pad The sensor pad is ideal for using in the drip trays of equipment where water is produced by process of condensation. Typically used where air cooling is fundamental to keeping an environments temperature stable such as data centres or comms rooms. This low profile sensor can be simply placed face down in the drip tray under an AHU or CRAC unit. A number of pads can be connected in series to allow several drip trays to be monitored by a single alarm panel or one zone of a multizone panel. Enclosure: Enclosure dimensions: Pad Material: Pad Dimensions: Voltage at probe: Temperature rating: ABS 55mm x 55mm x 40mm Tinned Copper 55mm x 55mm 5 volts @ micro amps - C to +40 C Typical Installation:

Inline Tee Sensor Probe The tee sensor has been designed to go into the over flow pipes on break tanks, toilet cistern and header tanks. The sensor is located inside the tee piece and gets installed on the overflow pipe with the sensor at the bottom. Any water that travels down the pipe and into the tee sensor will make contact with the conductors of the sensor and set off the alarm. Tee Piece: Tee Piece Sizes: Tee Piece Materials: Probe Material: Probe Diameter: Voltage at probe: Temperature rating: Speed-fit plumbing fitting mm, 22mm, 28mm (other sizes are available) Plastic or Brass Stainless steel 3mm 5 volts @ micro amps - C to +40 C Typical Installation: Float operated valve Overflow pipe with tee sensor Stop valve Break tank Solenoid valve Pump set

Solenoid Valves NORMALLY OPEN SOLENOID VALVES 2 way servo assisted 230VAC and 12VDC solenoid brass valves BSP Size Orifice Size (mm) Flow KV Lts/min Min Pressure (bar) Max Pressure (bar) Max Working (bar) Seals Max Media Temp C 3/8 13 40.0 ½ 13 40.0 3/4 13 165.0 1 25 165.0 1 1/4 38 367 1½ 38 500 2 50 600 2½ 65 50 0.3 3 75 13 0.3 Common Alarm Relay (1) taken off 230VAC supply to alarm panel live switch wire Normally Open (NO) Common L 2 E N 1 240VAC