IP Access FACP Adapters. Installation Guide. Entrada2DMK - IP Access FACP Adapter Kit. Kit Includes: Entrada2DMR - IP Access FACP Receiver

Similar documents
ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Installation Guide for models:

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for models:

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Rack Mount Series Installation Guide

Series. Access Power Controllers. Installation Guide

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

AL600ULADA. NAC Power Extender. Installation Guide

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Access Power Controllers with Power Supplies

AL800ULADA. NAC Power Extender. Installation Guide

SP-1000X. Panic Device Power Controller Installation Guide. Rev

AL600ULX Series. Power Supply/Charger. Installation Guide

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AL602ULADA AL802ULADA AL1002ULADA

more than just power! Altronix is the professional security industry s leading manufacturer

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

PDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual

Public Safety DAS Annunciator Panel

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

MODEL B2 INSTALLATION MANUAL

RELEASE DEVICE CONTROLS

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

FEC403EN Installation Manual

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

PDD-FT-3. Fire Panel Interface With EOL Trigger. Installation and Specifications Manual

Interface and EOL Modules 8

4100U City and Relay Cards Installation Instructions

Staff Alert Panel. Installation Guide. Using the Touchpad Exit Controller B

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Duct smoke housings, 4-wire D341/D341P and D342/D342P

LORAIN CIP 4890/48120 DC Power System

Power Supplies. Overview

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

EMERGENCY POWERHUBB NODE INSTALLATION AND OPERATION GUIDE

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

WM3000 WIRELESS MODULES

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

ACL TC 200 TEMPERATURE CONTROLLER

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

SensorHawk 4 PoE. For more information please visit us at or call us at 1 (800)

EX41922-T Hardened Unmanaged 2-port 10/100/1000BASE PoE + 2-port 100/1000 SFP Ethernet Switch. User s Guide

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

Connections. Application Note Jeronimo Rd. Irvine, CA February 20, 2008 Document Number AN0108, Rev A.1

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

SPEC SHEET. Simple Expansion Solutions ZONE EXPANSION MODULES: SINGLE AND MULTIPLE POINT

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

QD-ENG-68 Controller for Thermoelectric Thermal Management

Oxygen (O2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Booster Power Supply Manual

Long-Range Barrier Sensors

F220-B6PS/M. Installation Guide. Addressable Detector Bases

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

KT-100 Door Controller

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

D7053. Installation Instructions Multiplex Input/Output Module

Vocia VACIE. Reference Guide

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

Danfoss gas detection units

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

FEC400 Series. Installation Manual

SITESTAR CABINET DESCRIPTION

Duct smoke housing, 2-wire D340/D340P

PFC-4064 Conventional Fire Alarm Panel

Product Manual SZ1145

Off-Grid CyboInverter Installation Guide. For CI-Mini-1200H Solar Mini-Inverter for Electric Water Heaters

Control Panels D9412GV4/D7412GV4/D7212GV4. Approved Applications Compliance Guide

Long Range Radio Alarm Transmitter

July 14, 1999 DF C-100.

SELECT-A-HORN/STROBE SERIES

Transcription:

IP Access Adapters Installation Guide Entrada2DMK - IP Access Adapter Kit Kit Includes: - IP Access Receiver - IP Access Transmitter I.T.E. 43KC Doc. No. IIEntrada2DMK Rev. 062015 More than just power. TM

Overview: Altronix Entrada2DMK IP access adapter kit is specifically designed to interface with Network Door Controllers. They route power (PoE/PoE+) from a PoE switch or Midspan to the Network Door Controller and accommodate up to two (2) Fail-Secure strikes or Fail-Safe mag locks. The receiver features a supervised Fire Alarm Disconnect which releases locking devices while maintaining power to the Network Door Controller. The Fire Alarm Interface feature allows multiple units to be interconnected enabling any or all to be affected from a single trigger input. Specifications: Agency Listings: UL/cUL Listed for Information Technology Equipment (UL 60950-1). UL Listed for Access Control System Units (UL 294). CSFM - California State Fire Marshal Approved. CE - European Conformity. Input Power: For UL 60950-1 applications, use a UL Listed Endspan/ Midspan LPS limited power source. For UL 294 applications, use a UL 294 Listed PoE Midspan or Endspan (IEEE 802.3af/at). Power : Both lock outputs are selectable for either 12VDC or 24VDC and rated @ 8W (12V/667mA, 24V/333mA) each maximum (16W combined). Total power rated @ 30W (PoE and lock power). Trigger Input: 12VDC-24VDC shutdown trigger (Receiver). Two (2) independent 12VDC-24VDC access control trigger inputs (Transmitter). Fire Alarm Disconnect: Supervised Fire Alarm Disconnect is selectable for Normally Open (N.O.) or Normally Closed (N.C.) trigger input. Ethernet: Connectivity: RJ45. Wire type: 4-pair CAT-5e or higher structured cable. Distance: 100m max. Speed: 10/100BaseT. LED Indicators: : to RJ45 connector: Green - Remote Aux. OFF, Yellow - N/A. Midspan/Endspan Input RJ45 connector: Yellow - PoE UP, Green - N/A. : Network Door Controller RJ45 connector: Yellow - 1, Green - 2. Input from RJ45 connector: Green - PoE, Yellow - PoE Input. Environmental: See Temp. specifications and Humidity in Technical Specifications chart pg. 2. Mechanical: Dimensions (H x W x D approx.): 3.5 x 3.5 x 1 (88.9mm x 88.9mm x 25.4mm). Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application. Entrada is not intended to be connected to outside plant leads and must be installed indoors within the protected premises. Entrada is intended for indoor use only. (Fig. 1, pg. 4): 1. Mount Receiver in the desired location utilizing the unit s mounting hole. Use a #6 fastener with the proper wall anchor (ie. Ribbed Plastic, Drywall Anchor) when securing to the wall. Note: Anchoring fasteners should accommodate a minimum of 3 lbs. Unit should be located in proximity to the Midspan/Endspan (head end). 2. Before connecting structured cable from midspan or endspan to RJ45 jack marked [Midspan or Endspan] shut power off on the Midspan or Endspan. Note: Structured cable between the Midspan or Endspan and the should be a minimum of 26 AWG. 3. Connect structured cable from to RJ45 jack marked [ Transmitter]. 4. Connect alarm output relay to terminals marked [Supervised Fire Alarm Input Trigger] on. Place a 10K resistor (supplied) at the alarm output relay wired in series for a Normally Closed (N.C.)or wired in parallel for a Normally Open (N.O.) circuit (Fig. 4, pg. 6). To connect multiple units from a single refer to (Fig. 5, pg. 7). 5. To manually release locking devices a 12VDC-24VDC trigger may be applied to terminals marked [Shutdown Trigger] (Fig. 1, pg. 4). - 2 - Entrada2DMK

(Fig. 1, pg. 4): Factory Settings: Disconnect is enabled and Lock power outputs are set for 12VDC. If these settings meet your requirement, skip to Step 5. 1. Remove the four (4) screws from the cover. 2. For 24VDC lock outputs slide dip switch marked [SW1] to OFF (1) position, for 12VDC lock outputs slide dip switch marked [SW1] to position (Fig. 3a, pg. 5). 3. To disable Disconnect for either or both lock outputs slide the corresponding dip switches marked [S2] to the position, to enable Disconnect for either or both lock outputs slide the corresponding dip switches marked [SW2 (1), SW2 (2)] to the OFF position (Fig. 3a, pg. 5). 4. Replace cover and secure it with four (4) screws. 5. Mount Transmitter in the desired location utilizing the unit s mounting hole. Use a #6 fastener with the proper wall anchor (ie. Ribbed Plastic, Drywall Anchor) when securing to the wall. Note: Anchoring fasteners should accommodate a minimum of 3 lbs. Unit should be located in proximity to the Locking Devices. 6. Connect structured cable from Listed Door Controller to the RJ45 jack marked [Network Door Controller]. 7. Connect locking devices to the terminals marked [Lock Power s + 1, + 2 ], carefully observing polarity. Note: All interconnecting devices must be UL Listed and low-voltage Class 2 power-limited. 8. Connect wet trigger output(s) from Listed Door Controller to the terminals marked [Wet Trigger Input + 1, + 2 ], carefully observing polarity. Note: To ensure proper operation the Listed Door Controller must be programmed to apply power to the terminals marked [Wet Trigger Input] to release Fail-Safe devices (Mag Locks) or programmed to remove power from the to release Fail-Secure devices (Strikes). 9. Connect structured cable from to RJ45 jack marked [ Receiver]. Note: System should be tested at least once a year. Parameter Input Power Requirements Indicators Environmental Conditions Regulatory Compliance Weights (approx.) Description Technical Specifications: For UL 60950-1 applications, use a UL Listed Endspan/Midspan LPS limited power source. For UL 294 applications, use a UL 294 Listed PoE Midspan or Endspan (IEEE 802.3af/at). : Midspan or Endspan RJ45 connector: Yellow - PoE UP. Transmitter RJ45 connector: Green - Remote Aux. OFF. : Listed Door Controller RJ45 connector: Green - 2, Yellow - 1. Receiver RJ45 connector: Green - PoE, Yellow - PoE Input. Operating Ambient Temperature: : 32ºF to 122ºF (0ºC to 50ºC). : For 16W @ 12VDC or 24VDC output: 20ºC to 50ºC ( 4ºF to 122ºF). For 14W @ 12VDC or 24VDC output: 20ºC to 55ºC ( 4ºF to 131ºF). Storage Temperature: 20ºC to 75ºC ( 4ºF to 167ºF). Total power DC output plus PoE output not to exceed 30W. Relative humidity: 85%, +/ 5% Operating Altitude: 304.8 to 2,000m. UL/CUL Listed for: Information Technology Equipment (UL 60950-1). UL Listed for: Access Control System Units (UL 294). Compliance with IEEE 802.3 (at or af) specifications were not verified as part of UL294/B. CSFM - California State Fire Marshal Approved. CE - European Conformity. : Product: 0.25 lbs. (0.11kg) Shipping: 0.42 lbs. (0.19kg) : Product: 0.48 lbs. (0.22kg) Shipping: 0.66 lbs. (0.30kg) Entrada2DMK - 3 -

Fig. 1 UL 294 Listed PoE Midspan or Endspan Shutdown Trigger + --- A B C D A Green - Remote Aux. - OFF B Yellow - N/A C Yellow - PoE UP D Green - N/A Transmitter Supervised Fire Alarm Input Trigger Lock Power s + --- + --- Receiver E F G H E Yellow - 1 F Green - 2 G Green - PoE H Yellow - PoE Input Listed Door Controller Wet Trigger Input + --- + --- - 4 - Entrada2DMK

1, Voltage and Fire Alarm Disconnect Options: Switch Description (Factory Set) OFF SW1 NC Dry Contact Supervised Switch Description OFF SW1 Voltage 12VDC 24VDC SW2 1 & 2 Fire Alarm Disconnect Fire Alarm Disconnect Disabled Fire Alarm Disconnect Enabled Fig. 2 - PC Board Fig. 2a - - Dry Contact/Supervised Switch (Factory set to ) --- SW1--- - Dry Contact OFF - Supervised --- SW1--- - Dry Contact OFF - Supervised 1 1 Fig. 3 - PC Board Fig. 3a 1 2 --- SW2--- --- SW1 --- 12V OFF 24V 1 --- SW1 --- 12V OFF 24V Voltage Selector Switch 1 2 --- SW2--- Fire Alarm Disconnect Switches Entrada2DMK - 5 -

Typical Application: Supervised Fire Alarm Input Trigger Lock Power Wet Trigger Input 1 2 1 2 PoE+ Endspan or Midspan Shutdown Trigger Category-5e 100m 10K EOL C NO Alarm Relay 10K EOL NC C N.O. Trigger or N.C. Trigger Mag Lock Strike Lock Lock 1 Lock 2 Listed Door Controller Fig. 4-6 - Entrada2DMK

N.C. Connecting Multiple Units to a Single : Supervised Fire Alarm Input Trigger N.C. Midspan or Endspan Midspan or Endspan 10K EOL NO C N.O. Trigger Alarm Relay or C N.C. Trigger 10K EOL NC N.C. Midspan or Endspan Fig. 5 (Last unit) Entrada2DMK - 7 -

Notes: Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA phone: 718-567-8181 fax: 718-567-9056 website: www.altronix.com e-mail: info@altronix.com Lifetime Warranty Made in U.S.A. IIEntrada2DMK B20R MEMBER - 8 - Entrada2DMK