Low Wall Back Shelf Exhaust Canopy

Similar documents
LABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY

REQUIREMENTS FOR HOOD PLANS

MSYS 4490 AC Systems

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

SECTION COMMERCIAL-KITCHEN HOODS

COMMERCIAL KITCHEN SUPPRESSION SYSTEMS INFORMATION PACKET

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

2015 ICC Commercial Cooking Systems

MECHANICAL EXHAUST VENTILATION SYSTEMS OPERATIONAL GUIDELINES-REVISED 2003

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

Direct Gas-Fired Make-Up Air

Energy-Saving Demand Ventilation System

EVALUATION SUBJECT: GILES RECIRCULATING (VENTLESS) HOODS

Duo-Aire. VAC-1 Vertical Air Curtain Wall Hood Single Plenum

Contents Chapters 4 & 5 of the 2012 Michigan Mechanical Code CHAPTER 4, MMC: VENTILATION CHAPTER 5, MMC: EXHAUST SYSTEMS

MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361)

Chapter One Commercial Kitchen Fires

Modular Supply Make-Up Air Unit

2012 ICC Commercial Kitchen Hoods

Kitchen Ventilation Hood Permit Application

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

Modular Heating & Ventilating Unit Model IGX-HV

IMC Significant Changes Summary Tier I

CHAPTER 5: EXHAUST SYSTEMS

COMMERCIAL KITCHEN FIRE SAFETY

BETTER BUILDINGS BY DESIGN CONFERENCE 2008 Designing a Sustainable Commercial Kitchen FEBRUARY 13 BURLINGTON, VERMONT

Indirect Gas-Fired Make-Up Air

FOUNDATIONS OF MODERN KITCHEN VENTILATION (CKV) DESIGN HANDBOOK

Commercial Kitchen Exhaust Requirements Kitchen Exhaust for Food Service Operations

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

THE IDEAL SOLUTION FOR KITCHENS

Imperial Cal Products, Inc.

Direct Fired Heater Model AD Specification

Dear Concessionaire,

JSKI Installation-, adjustment and user guide

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

Mobile Vendors Bulletin

COMPETITIVE INITIATIVE POWDER COATING SPRAY SYSTEM MINES TECHNICAL SPECIFICATION

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Imperial. Cal. Products, Inc. Installation Instructions & Warranty Information. 425 Apollo Street Brea, CA

All the products you need for. Engineered Kitchen Ventilation Systems.

Imperial. Read Before Starting Installation!

MECHANICAL EXHAUST VENTILATION SYSTEMS FOR RETAIL FOOD FACILITIES. Design, Calculations, and Operational Guidelines

Food Service Establishment Plan Review Form

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

2012 INTERNATIONAL FUEL GAS CODE VENTS

FOOD SERVICE EQUIPMENT REBATES

Notable Changes in the Mechanical Codes

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

Inspection Checklist Mechanical Rough in

UMC 2012 ( ): Item # 38

Chilled Water DOAS Fan Powered Terminal Units

Inspection Checklist Mechanical Final

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Product Specifications. Vertical Floor Consoles By First Co.

Table of Contents. Laboratory Fume Hoods. UniFlow Fume Hood Systems. Fume Hood System Components. Custom Hoods, Enclosures & Cabinets

Ships and marine technology Fireextinguishing. of galley cooking equipment

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

2012 International Mechanical Code Significant Changes. About the Significant Changes

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR GAS FIRED OVEN

Cleveland Clinic Design Standards MECHANICAL SYSTEMS DESIGN GUIDELINES HVAC AIR DISTRIBUTION PART I - GENERAL 1.1 SUMMARY

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

Canning Shed/Facility Equipment Specifications

Ventless Operation Supplement GBF-D-VH

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

Table of Contents. Safety Information Content Checklist Measurements Preparation Installation

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2000 EDITION

Types of Detection. Fusible Link Detection - Most Common

ICC CODE CORNER 2015 International Fire Code

SECTION DUCTWORK

EXHAUST FAN SCHEDULE

Over-the-Range Microwave

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

MECHANICAL EXHAUST VENTILATION SYSTEMS Design, Calculations, and Operational Guidelines

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

RGE 13 A T - 1 A

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind Professional Series Liners

KITCHENS: Planning for Appliances, Lighting and Other Equipment

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Owner and Maintenance Guide Models Equipped with K250 Blower

IVI WARNINGS: Must be followed carefully to avoid personal injury. [VL

ENTERPRISE HOT DOG CART

10-year industry best core warranty. 5-year warranty on balance of unit.

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET

OPERATION, MAINTENANCE & & INSTALLATION MANUAL For. ELXC AND ELXC-UV ELXC-UVi SERIES VENTILATORS

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Owner and Maintenance Guide for M Line Range Hoods with M600/M1200 Blowers

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

Transcription:

ITEM NO. 710 Powerline Road Suite H Deerfield Beach, FL 33442 (954) 570-9860 (800) 322-8730 FAX (954) 570-9865 Low Wall Back Shelf Exhaust Canopy Model LW APPLICATION Wall mounted canopy style ventilator for use over medium duty equipment suitable for interior ceiling heights less than 8 6 by recessing into false ceiling. PRODUCT SPECIFICATIONS Furnish Hood Depot s ventilator model LW (ventilator without fire damper at the inlet slot) as shown on plans, with a depth of and an overall length of and to meet the following requirements: GENERAL DESCRIPTION: Ventilator is a conventional filter-type hood with continuous array of baffle U.L. Classified filters along the entire ventilator length. Ventilators up to 12 to include semi-concealed pitched gutter which slopes to removable grease cup. Ventilators over 12 include two pitched gutters that slope to removable grease cups located at each extreme end. Ventilator shall include means for hanging. CONSTRUCTION MATERIALS: The ventilator shall be 18 gauge all-stainless steel construction. A number 4 finish shall be provided on all exposed surfaces. LIGHT FIXTURES: Ventilator shall be equipped with U.L. Listed 100 Watt Dome Incandescent or Recessed 150 Watt Incandescent or Recessed Fluorescent fixtures. Light fixtures shall be prewired to a single point of connection at the factory. APPROVALS: Ventilator to be U.L. Listed, listed by NSF, and in accordance with all recommendations of NFPA 96. The ventilator must meet all applicable codes. DESCRIPTION These LW Series models are high velocity, low wall-mounted canopy ventilators which are U.L. Listed under the category of Exhaust Hood Without Exhaust Damper. Units are available in custom depths depending on particular cooking battery layout. All models include a full array of U.L. classified grease removing filters and a grease collecting gutter sloped to a removeable grease cup at either end. OPERATION When properly operated and maintained, the liquefied grease is drained off into a container for periodic removal and cleaning. MAINTENANCE At periodic intervals (such as the end of each cooking day) the filters are to be removed and cleaned. They may be washed in a dishwasher, hand washed or soaked and rinsed. AIR SUPPLY GUIDELINES Appropriately conditioned supply air must be mechanically delivered to the space to replace exhausted air. Generally 80% is so delivered with the remaining 20% flowing naturally from adjoining areas. EXHAUST/SUPPLY FAN UNITS Exhaust fan(s) and supply fan(s) are available. See fan section of catalog or web site for design information. Fans must be designed for Hood Depot air volumes and static pressure drop for the entire system and must be in compliance with local codes. Exhaust fan(s) should be properly sized and include UL762 listings Discharge ducts should be vertical when possible and located away from air intakes Supply fan(s) should be equipped with throw-away or cleanable type filters Exhaust and supply fans require a magnetic starter switch with 120 Volt holding coil and should be electrically interlocked for simultaneous operation Exhaust and supply fans should be operated through a listed kitchen hood control panel FIRE PROTECTION NFPA 96 and most other codes require a fire extinguishing system for protection of both the duct collar and plenum areas of ventilators and for the protection of cooking equipment such as fat fryers, griddles, ranges and broilers which may be source of ignition of grease. Check with local fire authorities for exact requirements. OPTIONAL EQUIPMENT Consult Hood Depot regarding custom services addressing: Exhaust Fans, Supply Fans and rooftop units HEPA Intake Units Fire protection systems Top Enclosure Skirts Heat Recovery Units S/S Filters Reduced Throat (low air volume) Ventilators Wall Panels Utility Distribution Systems (UDS) 3 Left or Right Standoffs Air Purification Systems Fluorescent Lights Listed Control Panels Demand Ventilation ASTM 2519 High Efficiency Filters *For full model number add canopy depth and height in inches as suffix (Example: Model LW-2630 for hood size 26 deep x 30 high) Page 34

Model LW Low Wall Backshelf High Velocity Exhaust Canopy Model LW Model LW Perspective View (N.T.S.) Engineering Data EQUIPMENT TYPE: LIGHT LOAD...Steamers, ovens, kettles (under 20 Gals.), open burner ranges, griddles, electric fryers MEDIUM LOAD...Kettles (under 60 Gals.), hot top ranges, woks, upright broilers, gas fryers Electrical An optional Hood Depot Control Panel can be provided for each exhaust fan. A contactor or motor starter will be provided for each fan. See section Control Panels in our catalog or visit our web site for more information. Static Pressure Static pressure drops across ventilator: Model LW...0.75 W.G. at the duct collar Canopy Hanging Weights Hood Depth 26 29 (Other depths avaiable) Wgt. per lin. ft. (LBS) 50 55 Airflow Data U.L. Listed for 250CFM / L.F. Contact factory for design criteria for specific appliance line layout designed for more CFM / L.F. (if equipment includes ranges fryers or griddles). Sizes Available Canopies available in widths of 26 and 29. Height is 30. Custom widths and heights available; contact factory. Lengths Available Hood lengths available from 4 0 to 16 0 in 6 increments. For lengths 6 6 to 12 0 the maximum offset from centerline and/or make-up air openings to end of hood shall not exceed 6 0. Lengths from 12 0 to 16 0 shall incorporate two exhaust ducts, each not to exceed 6 0 on center. Filters and lights are added in proportion to length. End View Elevation / Cutaway Page 35

ITEM NO. 710 Powerline Road Suite H Deerfield Beach, FL 33442 (954) 570-9860 (800) 322-8730 FAX (954) 570-9865 Low Wall Back Shelf Exhaust Canopy with Rear Supply Plenum Model LWB APPLICATION Wall mounted canopy style ventilator for use over medium duty equipment suitable for interior ceiling heights less than 8 6 by recessing into false ceiling. DESCRIPTION These LWB Series models are medium velocity wall-mounted canopy ventilators which are U.L. Listed under the category of Exhaust Hood Without Exhaust Damper. Units are available in custom depths depending on particular cooking battery layout. All models include a full array of U.L. classified grease removing filters and a grease collecting gutter sloped to a removeable grease cup at either end. OPERATION When properly operated and maintained, the liquefied grease is drained off into a container for periodic removal and cleaning. MAINTENANCE At periodic intervals (such as the end of each cooking day) the filters are to be removed and cleaned. They may be washed in a dishwasher, hand washed or soaked and rinsed. PRODUCT SPECIFICATIONS Furnish Hood Depot s ventilator model LWB (ventilator without fire damper at the inlet slot) as shown on plans, with a depth of and an overall length of and to meet the following requirements: GENERAL DESCRIPTION: Ventilator is a conventional filter-type hood with continuous array of baffle U.L. Classified filters along the entire ventilator length. Ventilators up to 12 to include semi-concealed pitched gutter which slopes to removable grease cup. Ventilators over 12 include two pitched gutters that slope to removable grease cups located at each extreme end. Ventilator shall include means for hanging. CONSTRUCTION MATERIALS: The ventilator shall be 18 gauge all-stainless steel construction. A number 4 finish shall be provided on all exposed surfaces. AIR SUPPLY GUIDELINES Appropriately conditioned supply air must be mechanically delivered to the space to replace exhausted air. Generally 80% is so delivered with the remaining 20% flowing naturally from adjoining areas. EXHAUST/SUPPLY FAN UNITS Exhaust fan(s) and supply fan(s) are available. See fan section of catalog or web site for design information. Fans must be designed for Hood Depot air volumes and static pressure drop for the entire system and must be in compliance with local codes. Exhaust fan(s) should be properly sized and include UL762 listings Discharge ducts should be vertical when possible and located away from air intakes Supply fans fan(s) should be equipped with throw-away or cleanable type filters Exhaust and supply fans require a magnetic starter switch with 120 Volt holding coil and should be electrically interlocked for simultaneous operation Exhaust and supply fans should be operated through a listed kitchen hood control panel FIRE PROTECTION NFPA 96 and most other codes require a fire extinguishing system for protection of both the duct collar and plenum areas of ventilators and for the protection of cooking equipment such as fat fryers, griddles, ranges and broilers which may be source of ignition of grease. Check with local fire authorities for exact requirements. LIGHT FIXTURES: Ventilator shall be equipped with U.L. Listed 100 Watt Dome Incandescent or Recessed 150 Watt Incandescent or Recessed Fluorescent fixtures. Light fixtures shall be prewired to a single point of connection at the factory. APPROVALS: Ventilator to be U.L. Listed, listed by NSF, and in accordance with all recommendations of NFPA 96. The ventilator must meet all applicable codes. OPTIONAL EQUIPMENT Consult Hood Depot regarding custom services addressing: Exhaust Fans, Supply Fans and rooftop units HEPA Intake Units Fire protection systems Top Enclosure Skirts Heat Recovery Units S/S Filters Reduced Throat (low air volume) Ventilators Wall Panels Utility Distribution Systems (UDS) 3 Left or Right Standoffs Air Purification Systems Fluorescent Lights Listed Control Panels Demand Ventilation ASTM 2519 High Efficiency Filters *For full model number add canopy depth and height in inches as suffix (Example: Model SWLV-6024 for hood size 60 deep x 24 high) Page 36

Model LWB Low Wall Style Back Shelf Exhaust Canopy with Rear Supply Air Plenum Model LWRP Perspective View (N.T.S.) Engineering Data EQUIPMENT TYPE: LIGHT LOAD...Steamers, ovens, kettles (under 20 Gals.), open burner ranges, pasta cookers, fryers MEDIUM LOAD...Kettles (under 60 Gals.), hot top ranges, gas fryers, griddles, braising pans Electrical An optional Hood Depot Control Panel can be provided for each exhaust fan. A contactor or meter starter will be provided for each fan. See section Control Panels in our catalog or visit our web site for more information. Static Pressure Static pressure drops across ventilator: Model LWB...0.75 W.G. at the duct collar Canopy Hanging Weights Hood Depth 42 48 54 60 (Other depths avail.) Wgt. per lin. ft. (LBS) 50 55 65 70 Airflow Data Light & Medium duty: Cooking surfaces to 400 = 250 cfm / lf. Heavy duty: Cooking surfaces to 850 = 280 cfm / lf. CFM criteria can vary and a higher cfm/lf is sometimes factory advised; contact us for airflow recommendation for your specific appliances Sizes Available Canopies available in widths of 40, 48, 54 and 60. Height can be 24 or 30 depending on ceiling height. Custom widths and heights available; contact factory. Lengths Available Hood lengths available from 4 0 to 16 0 in 6 increments. For lengths 6 6 to 12 0 the maximum offset from centerline and/or make-up air openings to end of hood shall not exceed 6 0. Lengths from 12 0 to 16 0 shall incorporate two exhaust ducts, each not to exceed 6 0 on center. Filters and lights are added in proportion to length. End View Elevation / Cutaway Page 37

ITEM NO. 710 Powerline Road Suite H Deerfield Beach, FL 33442 (954) 570-9860 (800) 322-8730 FAX (954) 570-9865 APPLICATION Low Wall Back Shelf Air Heavy Duty Exhaust Canopy Model LWZ Wall mounted backshelf style ventilator for use over medium duty equipment suitable for interior ceiling heights less than 8 6 by recessing into false ceiling. DESCRIPTION These LWZ Series models are for medium/high velocity wall-mounted backshelf ventilators which are U.L. Listed under the category of Exhaust Hood Without Exhaust Damper. Units are available in custom depths depending on particular cooking battery layout. All models include a full array of U.L. classified grease removing filters and a grease collecting gutter sloped to a removeable grease cup at either end. OPERATION When properly operated and maintained, the liquefied grease is drained off into a container for periodic removal and cleaning. MAINTENANCE At periodic intervals (such as the end of each cooking day) the filters are to be removed and cleaned. They may be washed in a dishwasher, hand washed or soaked and rinsed. PRODUCT SPECIFICATIONS Furnish Hood Depot s ventilator model LWZ (ventilator without fire damper at the inlet slot) as shown on plans, with a depth of and an overall length of and to meet the following requirements: GENERAL DESCRIPTION: Ventilator is a conventional filter-type hood with continuous array of baffle U.L. Classified filters along the entire ventilator length. Ventilators up to 12 to include semi-concealed pitched gutter which slopes to removable grease cup. Ventilators over 12 include two pitched gutters that slope to removable grease cups located at each extreme end. Ventilator shall include means for hanging. CONSTRUCTION MATERIALS: The ventilator shall be 18 gauge all-stainless steel construction. A number 4 finish shall be provided on all exposed surfaces. LIGHT FIXTURES: Ventilator shall be equipped with U.L. Listed 100 Watt Dome Incandescent or Recessed 150 Watt Incandescent or Recessed Fluorescent fixtures. Light fixtures shall be prewired to a single point of connection at the factory. APPROVALS: Ventilator to be U.L. Listed, listed by NSF, and in accordance with all recommendations of NFPA 96. The ventilator must meet all applicable codes. AIR SUPPLY GUIDELINES Appropriately conditioned supply air must be mechanically delivered to the space to replace exhausted air. Generally 80% is so delivered with the remaining 20% flowing naturally from adjoining areas. EXHAUST/SUPPLY FAN UNITS Exhaust fan(s) and supply fan(s) are available. See fan section of catalog or web site for design information. Fans must be designed for Hood Depot air volumes and static pressure drop for the entire system and must be in compliance with local codes. Exhaust fan(s) should be properly sized and include UL762 listings Discharge ducts should be vertical and located away from air intakes Supply fan(s) should be equipped with throw-away or cleanable type filters Exhaust and supply fans require a magnetic starter switch with 120 Volt holding coil and should be electrically interlocked for simultaneous operation Exhaust and supply fans should be operated through a listed kitchen hood control panel FIRE PROTECTION NFPA 96 and most other codes require a fire extinguishing system for protection of both the duct collar and plenum areas of ventilators and for the protection of cooking equipment such as fat fryers, griddles, ranges and broilers which may be source of ignition of grease. Check with local fire authorities for exact requirements. OPTIONAL EQUIPMENT Consult Hood Depot regarding custom services addressing: Exhaust Fans, Supply Fans and rooftop units ASTM 2519 High Efficiency Filters Fire protection systems HEPA Intake Units Heat Recovery Units Top Enclosure Skirts Reduced Throat (low air volume) Ventilators S/S Filters Utility Distribution Systems (UDS) Wall Panels Air Purification Systems 3 Left or Right Standoffs Listed Control Panels Fluorescent Lights Demand Ventilation *For full model number add canopy depth and height in inches as suffix (Example: Model LWZ-34 for hood size 34 deep) Page 38

Model LWZ Low Wall Style Back Shelf Heavy Duty Exhaust Canopy Model LWZ Perspective View (N.T.S.) Engineering Data EQUIPMENT TYPE: MEDIUM LOAD...Kettles (under 60 Gals.), hot top ranges, gas fryers, griddles HEAVY LOAD...Charbroilers, high grease equipment Electrical An optional Hood Depot Control Panel can be provided for each exhaust fan. A contactor or motor starter will be provided for each fan. See section Control Panels in our catalog or visit our web site for more information. Static Pressure Static pressure drops across ventilator: Model LWZ...0.625 W.G. at the duct collar Canopy Hanging Weights Hood Depth 42 48 54 60 (Other depths avail.) Wgt. per lin. ft. (LBS) 50 55 65 70 Airflow Data Light & Medium duty: Cooking surfaces to 400 = 171 cfm / lf. Heavy duty: Cooking surfaces to 600 = 309 cfm / lf. CFM criteria can vary and a higher cfm/lf is sometimes factory advised; contact us for airflow recommendation for your specific appliances Sizes Available Canopies available in widths of 26, 29, 32 and 34. Custom widths available; contact factory. Lengths Available Hood lengths available from 4 0 to 16 0 in 6 increments. For lengths 6 6 to 12 0 the maximum offset from centerline and/or make-up air openings to end of hood shall not exceed 6 0. Lengths from 12 0 to 16 0 shall incorporate two exhaust ducts, each not to exceed 6 0 on center. Filters and lights are added in proportion to length. End View Elevation / Cutaway Page 39