THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Similar documents
Meets all design requirements of U.S.EPA. Double pass optical system for accuracy and sensitivity. Modulated light beam to eliminate interference

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

Technical Information OUSAF44

International comparison of validation methods for dust concentration measurement

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

PRODUCT CONFORMITY CERTIFICATE

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

Technical Information OUSAF12

818 Series Low-Power Detectors

Technical Information OUSAF22

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

Technical Information OUSAF21

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

APPLIED. OMA-406R Rackmount Process Analyzer

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

PUV, PIR and PFO Series BROCHURE

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

OMA-300 Process Analyzer

Instruction Manual E4 ChamberIR Heater

CERTIFICATE of Product Conformity (QAL1 )

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

An FT-NIR Primer. NR800-A-006

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

Pyroelectric Infrared Sensor PIR

Bristol Babcock Oil Content Monitor "oil in water"

Technical Information OUSTF10

Technical Information OUSTF10

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Technical Data Sheet 5mm Infrared LED, T-1

INSTRUMENTATION FOR MARINE BLACK CARBON MEASUREMENTS

Instruction Manual Rev 2.0. OPM3000 Opacity/Dust Density Monitor Installation and Operation Manual Rev 2.0

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Using the DewTrak II Dew Point/ Humidity Transmitter

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

CLARITY II TURBIDIMETER

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

Certificate: _01 / 22 March 2013

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

Instruction Manual IM , Rev 2.0 November 2008 OPM Opacity/Dust Density Monitor.

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

FIREYE C9707A ALL FUEL SCANNER

HFID Heated Total Hydrocarbon Analyzer Module

ALK-V PHOTOELECTRIC SMOKE SENSOR

Extreme High-Intensity Sensors Thru-Beam and Fiberoptic Penetrates Many Packaging Materials for Content Verification

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

This document is a preview generated by EVS

Model DT109D Opacity Measurement System

SEC Signature Process Gas Analyzer

Certificate: / 29 April 2014

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

Class 1 laser beam sensor safe for your eyes

Optical Time Domain Reflectometry (OTDR)

Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications

Broadening IR applications through using spectral filters

Temperature dependent Components within the Pyroelectric Detector

ISO INTERNATIONAL STANDARD. Coating powders Part 13: Particle size analysis by laser diffraction

OWNERS MANUAL OPERATION GUIDE

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

M7100 Pressure Transducer

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

MXD75 Multi Channel Suspended Solids and Turbidity Transmitter

COURSE 474 CONTINUOUS EMISSION MONITORING Extended Agenda

Specifications Wavelength Range: 190 nm to 800 nm continuous

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

UV Flame Supervision System

SuperOX TM Oxygen Sensor U.S. Patent No. 5,635,044

COMPACT FLAME CONTROLLER CFC 1000

Air Resource Specialists, Inc.

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

CERTIFICATE of Product Conformity (QAL1 )

Class 1 laser beam sensor safe for your eyes

BLACKSTAR ELECTROMAGNETIC MEASUREMENT WHILE DRILLING (MWD) TOOLS

Technical Information OUSBT66

The Emergence of Triboelectric Technology

Understanding total measurement uncertainty in power meters and detectors

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Series 5000 Hydrazine Analyzer Model 60002

Turbimax CUE21 / CUE22

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

APPROVED by U.S. EPA As a Class III Equivalent Method Designation for the measurement of PM 2.5

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

Spectrum Detector, Inc.

TrueAlarm ES Analog Sensing

Installation and Operating Instructions

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor

Transcription:

Table of Contents INTRODUCTION 1 THEORY OR OPERATION 2 DESCRIPTION 5 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 SPECIFICATIONS 10 OPTIONS 11 ADDITIONAL SPECIFICATIONS AS REQUIRED BY ISO CD 11614 12 INSTALLATION CRITERIA 13 MAINTENANCE 14 PART NUMBERING AND ORDERING INFORMATION 14

INTRODUCTION This manual is intended to acquaint you with the Model 107 In-Line Diesel Exhaust Smokemeter by explaining the theory of operation, providing technical descriptions of the unit, smokemeter specifications, installations criteria, and ordering information. Existing federal regulations have been established on a quality level for exhaust emissions during diesel engine manufacturing. Many state and local agencies, charged with the protection of the environment are implementing regulations that are intended to ensure that a high standard of emissions is maintained throughout the life of the vehicle. Nearly all regulations define diesel exhaust quality in term of the opacity of the smoke plume. The Model 107 Smokemeter was designed to meet or exceed all performance specifications for diesel exhaust smokemeters advanced by the Society of Automotive Engineers and the International Standards Organization as well as the U.S. Environmental Protection Agency as established by the following: 1. SAE J1157, Measurement Procedure for Evaluation of Full-Flow, Light-Extinction Smokemeter Performance, dated August 1976. 2. SAE J1243, Diesel Emission Production Audit Test Procedure dated October 1978. 3. ISO CD 11614, Apparatus for the measurement of the opacity and for the determination of the light absorption coefficient of exhaust gas from internal combustion engines, dated March 1992. 4. U.S. EPA 40CFR86.884-9, Emission Regulations for Diesel Exhaust Emissions, dated, 1999. 5. 1999/96/EC, European Community Heavy Duty Diesel Exhaust Emissions, dated, 1999. 6. ISO/TC 70/SC 8/WG 1/ N 65, Euro 3 technical annex III, Appendix 4, Section5; General Description of Opacimeter, dated May 1997. The instrument described herein is designed for use in any of the following three modes: Federal cycle opacity measurement for compliance with emission regulations. Exhaust emission research and engine design studies. Engine production line emission testing and quality assurance. 1

THEORY OF OPERATION The basic principle utilized by the Model 107 in measuring smoke density is the attenuation of the intensity of a collimated light beam by smoke aerosol absorption and scattering from a diesel engine exhaust. Measurement is accomplished by passing light pulses through the engine exhaust stream and detecting the loss in light transmission due to exhaust smoke and a photoelectric detector. The relative light energy loss is translated into both OPACITY and SMOKE DENSITY (K) signals, which are displayed digitally at the control unit. In figure 1, the LED light source of intensity I 0, and condensing lens produce a collimated light beam which passes through the center of the smoke column. Some of the light is absorbed or scattered by smoke aerosols, thus reducing the intensity of the light that reaches the detector focusing lens and the photodiode to I. The light intensity reduction can be expressed as: 2

A parameter, K, the smoke density, has been defined as : K=naQ The smoke opacity, defined as one minus the fraction of light transmitted, and the smoke density can thus be related as follows: I/I 0 = e -KL = T/100-1 - N/100 N = (1 - I/I 0 ) 100 = OPACITY (%) K = (-1)/L) Ln (1 - N/100) = SMOKE DENSITY (m -1 ) The relationship between the Opacity, N, and the smoke density, K, for the various Model 107 exhaust diameters and shown in Table1. Table 1 Smoke Density K 2" (.0447M)N % 3" (.0701m) N% 4" (.0955m) N% 6" (.137m)*N % 8" (.188m)*N % 10¾" (.254m)*N % 12¾" (.304m)* N% 18" (.432m)* N% 24" (.588m)*N % 28" (.690m)*N % 0.00 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.50 2.2 3.4 4.7 6.6 9.0 11.9 14.1 19.5 25.5 29.1 1.50 6.5 10.1 13.3 18.6 24.6 31.7 36.6 47.7 58.5 64.5 3.50 14.5 21.8 28.4 38.1 48.2 58.9 65.5 78.0 87.2 91.1 10.00 36.0 50.4 61.5 74.6 84.7 92.1 95.2 -- -- -- 11.50 40.2 55.3 66.7 79.3 88.5 94.6 97.0 -- -- -- *NOTE: The Effective Optical Path Length (EOPL) is not necessarily the exact I.D. of the stack, due to purge air effects. See following section "Effects of purge air on optical path length". The purpose of the smokemeter is to measure a characteristic of the engine smoke, inherently relatable to smoke as observed by the human eye. The fundamental characteristic that determines smoke obscuration of light is the smoke density, K; however, this parameter is not independently measurable. The opacity of the smoke on the other hand can be easily measured and the smoke density calculated electronically. As indicated by the above equation, for a given smoke density the light intensity decreases exponentially with path length. This fact should be kept in mind, if the Model 107 is being used in exhaust lines with an engine port of diameter different that the Smokemeter. As an example, consider an engine with a 2-inch diameter exhaust with the 6-inch diameter M107 suitably attached by means of an expansion section. The smoke density, K107, measured in the 6-inch diameter Smokemeter is the same as K e, the smoke density of the engine exhaust. However, the measured opacity, N107, will be greater in the Smokemeter than would be measured in the 2-inch engine exhaust line because of the greater path length. If, for instance, the measured opacity is 6.6% in the M107, the engine exhaust opacity is only 2.2% for a 2-inch diameter. Again, this relationship is shown in Table 1. 3

Effects of Purge Air on Optical Pathlength The purge air system introduces clean air into the emitter/detector support modules in a way that protects the lenses from smoke deposition and at the same time will not change the smoke light path-length. The air directed across the lenses, flows through the support tube at a rate, which prevents smoke penetration of the tube, and exhausts into the main exhaust flow. The optimum flow rate for protection without path-length alteration has been experimentally determined to be 3 SCFM (Standard Cubic Feet per Minute). The purge air velocity entering the exhaust plume is approximately 12 feet per second (1.5 SCFM through each 5/8" port). Smokemeters should be matched to engine sizes that produce velocities greater than 30 feet per second so that the purge air will have no effect on the smoke optical path-length. See Figure 2. 4

DESCRIPTION The rugged construction and advanced electronic design make the Model 107 well suited to serve as the standard for measurement of engine emission quality assurance. The Model 107 Smokemeter consists of the following major components: In-line Sensor Unit including emitter/detector modules, sensor module mounts, air purge line and fittings, basic flow pipe with heat shield, pipe flanges for customer welding to mating exhaust line pipe, and clamps for joining flow pipe mating pipes. Control Unit including rack mount chassis and power cord. Interconnecting Cable (50 ft.) for connecting Control Unit and Sensor Unit electrically. 5

SENSOR UNIT - MECHANICAL The sensor unit provide a stable mount for the light emitter and detector modules as well as containment of the exhaust gasses as the flow from the engine to the outside atmosphere. The mechanical core basic sensor unit is a can formed of a stainless steel pipe with mounting flanges on both ends for adaptation to the engine exhaust system. The rigid emitter/detector support ring is spring-mounted to the can providing thermal isolation for the optical elements from the hot exhaust flow pipe. Further temperature isolation is afforded for the optical elements (emitter and detector) by water-cooled sensor mounts which extend radially from the support ring and by a cylindrical stainless steel radiation shield which is mounted concentrically with the basic flow pipe. Customer supplied clean compressed air is directed across the lenses of the optical system to prevent smoke deposition. Modular construction allows the sensor unit to be assembled, installed and adjusted easily. SENSOR UNIT The mechanical core basic sensor unit is a can formed of a stainless steel pipe with mounting flanges on both ends for adaptation to the engine exhaust system. 6

The Model 107 is currently available with 2", 3", 4", 6", 8", 10 ¾", 12 ¾", 18", 24" and 28" exhaust can diameters. Actual can dimensions are as follows: O.D I.D. CAN LENGTH 2" (5.08cm) 1.760" (4.47cm) 15" (38.1cm) 3" (7.62cm) 2.760" (7.01cm) 15" (38.1cm) 4" (10.16cm) 3.760" (9.55cm) 15" (38.1cm) 6" (15.25cm) 5.760" (14.63cm) 15" (38.1cm) 8" (20.32cm) 7.760" (19.71cm) 15" (38.1cm) 10.75" (27.3 cm) 10.482" (26.62cm) 15" (38.1cm) 12.75" (32.39cm) 12.438" (31.59cm) 15" (38.1cm) 18" (45.7cm) 17.624" (44.8cm) 15" (38.1cm) 24" (60.96cm) 23.624" (60cm) 15" (38.1cm) 28" (71.12cm) 27.624" (70.17cm) 15" (38.1cm) 7

SENSOR UNIT - ELECTRICAL A light emitting diode (LED), thermal compensator and a collimating lens are mounted in one of the removable sensor modules that extends from the support ring. The LED is rugged, highly efficient and therefore, is not subject to failure caused by vibration or age. A green LED with a maximum light intensity at 570 nm is used, to comply with accepted smokemeter specifications. A photodetector consisting of a photodiode and a preamplifier is mounted in the other sensor module along with a focusing lens for measurement of the transmitted light. The photodiode is used because of its excellent dynamic range and response, high output and excellent reliability. The smoke opacity reading is unaffected by background ambient light in the pipe due to the pulsed LED light source, (with an approximated 2% duty cycle at 600 Hz), and the AC coupled photodetector signal within the control unit. The measured photodetector signal thus represents only the pulsed light from the LED. Extraneous light is ignored. 8

CONTROL UNIT - MECHANICAL All operating controls and the indicating meter are mounted in a 16" (40.64cm) long x 3" (7.62cm) high x 6" (15.24cm) deep chassis, which is designated for a standard electronic equipment rack mount 19" (48.26cm) long x 3 1/2" (8.89cm) high. The chassis contains a regulated power supply, amplifier, and cable terminations. MODEL 107 CONTROL UNIT CONTROL UNIT - ELECTRICAL The control unit has been constructed for reliability and ease of operation. The unit operates over a wide range of input voltages from 100 VAC to 240 VAC and from 50 to 60 Hz. 9

PERFORMANCE SPECIFICATIONS OPACITY SCALE: 0 to 100% Range 0.1% Resolution ±0.5% of full-scale opacity due to non-linearity, 24-hour drift, etc., ±0.3% (absolute) during any 4 hour test period. Accuracy SMOKE DENSITY K SCALE: Range 0 to 19.99 m -1 Resolution 0.01 m -1 Accuracy ±0.05 m -1 to smoke density of 2 m -1 ; ± 3% of readings above 2 m -1 READOUT: 3 1/2 Digit Display (Filtered) RECORDER OUTPUTS: 10 mv per % (Opacity), 0 to 1 VDC Full Scale, 100 mv per m -1 (Smoke Density), 0 to >10 VDC Full Scale, Response time, 0.01 seconds to 90% LIGHT SOURCE: Angle of Projection Spectral Output Pulse Rate Light Emitting Diode (GREEN) 99% within 3 degrees, half angle 520 to 610 nm: Peak = 570 nm (GREEN) 600 Hz RECEIVER: Angle of View Spectral Response Silicon Photodiode 99% within 3 degrees, half angle 400 to 1100 nm 10

Performance Specifications (Continued) Operating Temperatures: Control Unit Sensor Unit Cooling Water 10 º C to 50 º C 50 º C Max. Cell Ambient - without cooling water 70 º C Max. Cell Ambient - with cooling water 800 º C Max. Gas Temperature 25 º C to 45 º C, with a flow rate of approximately.3 gallons per minute Power: 100 VAC to 240 VAC (Selectable), 50 to 60 Hz,10 Watts Stack Diameter: 2", 3", 4", 6", 8", 10¾ ", 12¾ ", 18", 24", 28" Effective Optical Length: 2" =.0447m 6" =.137m 12¾ =.304m 3" =.0701 m 8" =.188m 18" =.432m 4" =.0955m 10¾" =.254m 24" =.588m 28" =.690m Control Unit Dimensions: 19" (48.3 cm) wide x 3.5" (8.9 cm) high x 6" (13.6 cm) deep Options Available Linearity Calibration Unit, Option CO-1 In-Situ linearity calibration unit, with 3 neutral density filters (nominal values of 10%, 20% and 40%). 1 Second Bessel Filter for K Provides an analog output of 0-10 Volts which corresponds to 0-20K. For conformance to Euro III specifications. ISO-Pak Gas Temp. probe (TC shielded probe with TC connector), and exhaust gas Pressure Tap. Inclusion of this option allows the unit to meet ISO Smokemeter specifications (ISO 11614). Correction of K (m -1 ) To 100 º C Gas Temp: Corrects K (m -1 ) Smoke Density to 100 º C Gas Temperature. 11

Options Available (Continued) Purge Air Filter: Norgren F-40-200-AOTA Berkeley P/N 44-0715-01 Purge Air Regulator: Norgren R11-200-RGL Berkeley P/N 44-0716-01 Recorder Output: (Opacity): 0 to 5VDC, Full Scale 1 to 5 VDC, Full Scale 0 to 10 VDC, Full Scale 0 to 5 VDC, 0 to 30% 0 to 10VDC, 0 to 30% Additional Specification as Required by ISO CD 11614 Exhaust Flow Limits: Exhaust Gas Pressure: Scavenge Air Pressure: Physical Response Time: Electrical Response Time: Response Time of Temperature Sensor: (Required for correction of K to 100 0 C) Min: 30 ft. per Sec. Max: None (as long as exhaust gas pressure is maintained to ±1 kpa from P atm practically 100 ft. per Sec. ±1 kpa from P atm >4 PSIG <8 PSIG as measured at the "Y" connection to the sensor mounts (see page 13); Flow controlled by design 3 SCFM (Standard Cubic Feet per Minute). T p = <.05 sec. T e = <.01 sec. T t = >1 0 <2 0 C/second 12

Installation Criteria The installation drawing 88-0995-01 Rev D outlines the important criteria in installing the Model 107 Smokemeter. To install the Sensor Unit in the exhaust system, a straight section of pipe is removed and the adapter flanges are installed so that the spacing between them is 15 inches (38.1cm). The unit is placed in the open section and held in place with the clamps provided. Straight sections of pipe should precede and follow the Sensor Unit to ensure uniform flow conditions in the measuring section. If required, transitions from other size pipes, forward and aft of the straight sections should be made with conical sections using half-angles no greater than 12". The air supply for the air purge system should be as oil-free as possible with high quality air filters, such as the Norgren filter, installed as close to the Sensor Unit as is practical. The recommended air pressure as measured at the yoke in the air purge line is 5 psi, although pressures as low as 4 psi have been used successfully. The compressor volume flow will be approximately 3 CFM. 13

MAINTENANCE The Model 107 Smokemeter is relatively maintenance-free. However, the area requiring the most attention is the sensor modules' air purge system. Oil and moisture filters must be kept in good operating condition. Oil film on the lenses resulting in 1% to 2% opacity is not always visible to the eye. A periodic check and cleaning of the lenses is recommended. ORDERING INFORMATION MODEL 107 Control Unit: Indicate Line Voltage. Choose From 100v, 220v, Or 240v. Choose Can Size And Indicate Vertical Or Horizontal Installation. Indicate Required Options From Below. Opacity Recorder Output Options (maximum of 2 outputs) 0-5 Volt 0-100% Opacity 1-5 Volt 0-100% Opacity 0-10 Volt 0-100% Opacity 0-5 Volt 0-30% Opacity 0-10 Volt 0-30% Opacity Additional Options: Smoke Density (K) Recorder Output Temperature T/C Probe and Pressure Tap (Iso-Pak) 100 C Gas Temperature Correction Of K 1 Second Bessel Filter For K C-01 Linearity Calibrator Slide Alignment Tube For Optics SEE PRICE LIST FOR COMPLETE LISTING OR AVAILABLE ITEMS Order the Purge Air Filter and Regulator separately: Purge Air Filter: P/N 44-0715-01 (Order separately) Purge Air Regulator P/N 44-0016-01 (Order separately) Thank you for your interest in our product. Please feel free to contract us for additional information. 14

TELONIC BERKELEY, Inc 1080 La Mirada Court Vista, CA 92081 Phone: (760) 744-8350 Fax: (760) 744-8360 Web: Email: www.telonicberkeley.com info@telonicberkeley.com 15