Magnet Clamping Systems

Similar documents
AIR CLAMP VALVE UNIT OPERATION PANEL CONTROL UNIT AIR CLAMP SYSTEM

Compact Ultra Low Temperature Chamber

Thermal Shock Chamber TSE 11

Vacuum Interrupters. Outstanding vacuum-related manufacturing techniques of MEIDEN has

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

Superior Temperature Control. world of innovation

Unlocking the Potential of Blood TSCD II. Next-Generation Terumo Sterile Tubing Welder

Liquid to Liquid Thermal Shock Chamber TSB 21 TSB 51

Faster Temperature (& Humidity) Chamber

Control Panel Basics Volume 1

Signal Tower. See More, Do More!

Superior Temperature Control. world of innovation

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

hgate Product Catalog

Superior Temperature Control. world of innovation

nugate Product Catalog

Utility. Improved functionality and ease-of-use for bias testing. The chamber interior is formed for easier specimen loading

TEMPRO Mold Temperature Controllers. Superior Temperature Control. Technology working for you.

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Forma 1400 Series Class II, Type A2 Biological Safety Cabinet. Superior Ergonomics, Uncompromising Safety

DOUBLE COLUMN GRINDING MACHINE. ACC-CH iq SERIES

Bench-Top Type Temperature (& Humidity) Chamber

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Faster Temperature (& Humidity) Chamber

MD-S7000. All Electric Injection Molding Machine NIIGATA MACHINE TECHNO CO.,LTD.

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

Sensepoint XCL Fixed Gas Detector

LCF Touch. Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet. Application. Security Advice Caution.

ignored. Denotes content that may result in bodily injury and physical damage when ignored.

Ultrasonic Level Measurement nivopuls FDU 10 S

Ck056. Disassemble and wash type Quick Connect Couplings. Easy Wash Type HACCP. supporting product. Products Comply with RoHS Directive

T5000 T5000 LCD Digital Fan Coil Thermostat--More Models

Temperature Controllers TW, TO, TP Series

SHAKING WATER BATHS ENGLISH

Leak Detector [HELIOT 710 Series]

Performance. TCC-150 provides uniform temperature load, and highlyrepeatable temperature change rate. Conformity to JEDEC JESD22-A104-B standard test

WALL MOUNTED TYPE ROOM AIR-CONDITIONER

Monitored Pneumatic Valves On Series Ported Manifold

Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities.

Heat Recovery Ventilator

Metalarm Metal Detectors. Model TR, BR, PL, PL2 and VC and HH-10 ERIEZ. ...Only from Eriez. Features:

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E

NXM2G Installation and Operating Manual

Productivity and sewing quality are combined at the highest level ever.

Electronic eyelet button holer RH-9820

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

½ Monitored Pneumatic Valves On Series Ported Manifold

Section 7: Cable Glands & Duct Seals.

DWF Series IP68 DECORATIVE WATER FEATURES.

INSTALLATION & OPERATION MANUAL

IN-SITU ZIRCONIA OXYGEN ANALYZER

Level gauges Series LS Level indicator, switch and transmitter for liquids

Silane Coupling Agents. Combination of Organic and Inorganic Materials

OPERATION MANUAL (Web Site Downloaded only)

Environmental Stress Chamber AR series

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

Circuit Protector. GCP Series. Features. Electromagnetic Overcurrent Protection. Approvals. AC/DC Dual Voltage. Easily Identified ON/OFF Indicator

Comprehensive Catalog of Environmental Equipment

Ceiling Mount Temperature Sensor

Water Circulator (Chiller) & Cold Trap

U5300 Industrial Pressure Transducer

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

PACIFIC HVAC Air conditioner. Authorized Daikin Split systems & VRV contractor. Tel:

Door Release Power Supply

IN-SITU ZIRCONIA OXYGEN ANALYZER

M2500 Engine Controller Installation Manual

Condensate removal pumps

TEMPORARY SPECIFICATION FOR REFERENCE

Figure 1 TWM1000 Electromagnetic Flow Converter. 1. Large, illuminated graphic display with intuitive operation 2. For AC and DC operation

Gas Detection. Touchpoint Plus. A whole new control experience

Industrial cooling systems LT

MXSU - Selection table 3-core Kits / X-section

VACUUM FOR HIGHER QUALITY. In plastic injection molding

F3SJ Overview. Three Versions available to meet your exact safety needs. Safety Light Curtains NEW! Introducing the F3SJ Series

ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor

T8000 Series T8600 MODBUS Touch Screen Thermostat

Address: 2857 Sherwood Heights Dr. Unit 2, Oakville, ON, Canada. L6J 7J9 Toll free: LOGIKA

FULL AUTOMATIC EXTINGUISHING SYSTEM FOR INDUSTRIAL MACHINERY YAC-3A. Table of Contents

LC-3DPRINT BOX. Instruction For Use. LC-3DPrint Box

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

CII FCAC-150 Series Relay

Wafer Beveling Machine. Delivery Specification

HeaCo (Heat & Cool) Mold Temperature Control System. HeaCo Installation Manual. HeaCo Installation Manual. Unibell Korea Sep.

47LV BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL DC INPUT DIGITAL PANEL METER MODEL. (4 1/2 digit, LED display type)

OX100/OX102. Limiting-current type Oxygen Analyzer. Bulletin 11M10A01-03E

Leakage detection sensor

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Comprehensive Catalog of Environmental Equipment

Compressed Air Packages

MAYEKAWA MFG. CO., LTD Botan Koto-ku, Tokyo , JAPAN TEL:(81) FAX:(81)

Intense, cold and dry Efficient disinfection of packaging materials Premium UV solutions from Heraeus Noblelight

IN-SITU ZIRCONIA OXYGEN ANALYZER <HART communication>

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

DESCRIPTION FEATURES WARNINGS APPLICATIONS

AE500 Instruction Manual

The World's Longest-distance * Detection

AL-KO CONTROL TECHNOLOGY THE SIMPLE ROUTE TO CONTROL

Hi-spec Design model. Photo : LT series

JM Series. 7-inch Touchscreen Intercom

Transcription:

New Magnet Clamping Systems The World's Thinnest (37mm) Magnet Clamp!! (model MEG) Magnet clamping systems that ensure safety in operations. Large reduction in mold changing time.

MOLD ALARM MAGNET

MEK 150 2-7 S 13001

φ

Magnet Clamping Systems Power Unit m od e l MEC Features Operation Panel Magnetic Force Indicator This six-level illuminated indicator makes the invisible magnetic force visible. Located in the Operation Panel, it makes confirmation of Interlock Operation Panel communicates with the IMM to prevent operational sufficient force easily possible during operation. errors before they happen. An alarm sounds when magnetic force falls below 75%. The risk of mold dropping due to operational error is established. MAGNETIC FORCE GAUGE Display of Mold and IMM Status 100% The operation panel lamps indicate the presence of a mold, and if mold opening and mold closing are 90% operating properly. 80% Superior Performance 75% Simple operation leads to improved performance. 50% Compact 25% The operation panel fits in the palm of one s hand for ease of operation. 0% Magnetic Force Indicator Display Features Control Box Clamping Process Indicator (C.P.I.) The new C.P.I. clearly shows the type of error the clamp is experiencing, greatly simplifying recovery operations. For larger machines, there are multiple sensor coils that relay magnetic performance data, making it easy to identify the underperforming area. Superior Protection The MEC/MEW Power Units have an IP (Ingress Protection) rating of IP5X, a level that protects against the entry of dust particles, ensuring proper functionality. Compliance Friendly Clamping Process Indicator 固定 金型 MOLD プレート 異常 ALARM 可動 マグネット MAGNET The MEC/MEW units can comply with the standards of each country of operation. Magnet Burn-Out Protection If the magnets are activated or deactivated six times within a oneminute period, the operational function shuts down to avoid system burn-out. Functionality returns after 180 seconds. Wiring Clamping Process Indicator High-Speed Model model MEW Made-to-Order The MEW Power Unit cuts in half the time needed to activate/deactivate the magnets. Especially for larger magnetic clamping systems with many magnets to be activated/deactivated, this is a suitable option when shortened clamp-changing time is essential. 11 The cable connectors have been redesigned to make installation of the unit easier.

Model No. Indication Features Specifications External Dimensions External Dimensions Control Box Operation Panel Interlock Operating Procedure Model No. Indication Control Box / Operation Panel Magnet Clamping Systems Magnet Plate MEC 07 4 2 - V S 1 2 - J 1 2 3 2 8 7 6 5 4 Power Unit Power Unit Mounting Bracket Safety Chain 1 Attractive Time Cautions MEC : Standard MEW : High Speed 1 1. Please contact us for the details of MEW high speed model. 2 Box Size 4 : For 1 / 2 / 4 Discharge Common Use B : For 12 Discharge 8 : For 8 Discharge D : For 16 Discharge 3 Design No. 2 : Revision Number 4 Mold Change System V : Vertical Loading H : Horizontal Loading 5 Operating Temperature S : 0 120 Standard 6 The Number of Discharge 1 : 1 Discharge 8 : 8 Discharge 2 : 2 Discharge B : 12 Discharge 4 : 4 Discharge D : 16 Discharge 7 Voltage 2 : AC200V 50 / 60Hz 2 8 Indication Language 2. Please contact us for voltage other than 200V (50/60Hz). 3 J : The control box is written in both Japanese and English, while the remote operation panel is written in Japanese only. E : The control box is written in both Japanese and English, while the remote operation panel is written in English only. C : Both the control box and the remote operation panel are written in Chinese only. 3. Please contact us for indication language other than Japanese, English and Chinese. Specifications Model No. MEC / MEW Operating Temperature 0 55 (Based on JIS-C0025) Operating Voltage AC200V (50 / 60Hz) Permitted Range of Voltage±10% Withstand Voltage AC1000V (10mA/1 min.) Resistant Vibration Environment Protection Level Paint Color Notes : 1G/10 150Hz (Based on IEC60068/JIS-C0040) IP5X (Based on IEC60529 : 2001) Mansel 5PB4/4 (Japan Paint Color 75-40H) 1. For any specifications other than those described in "Model No. Indication" and "Specifications" sections, please contact us. "-Z " is added to the end of model in case of special execution. 2. Please contact us for specifications for North America. 12

φ φ φ φ

MOLD ALARM MAGNET MOLD ALARM MAGNET MOLD ALARM MAGNET MOLD ALARM MAGNET MOLD ALARM MAGNET

MOLD ALARM MAGNET MOLD MAGNET ALARM MOLD ALARM MAGNET MOLD ALARM MAGNET MOLD ALARM MAGNET MOLD ALARM MAGNET

MEJ 003 0-08

MES 100 1 - BC - 05-00

φ

Quick Ejector Rod model PME The ejector rod has been divided into a base rod and an attachment rod for speed, simplicity and ease-of-use when changing ejector patterns. No tools are required, allowing changes in mere seconds. Changing Ejector Rods Move the ejector plate Pull out the attachment Arrange them in the new Ejector rod patternchange fully forward. rods by hand. pattern. in seconds! Exchange start Two seconds progress Four seconds progress Completed in about five seconds 1 1. The changing time varies with molding machine size, ejector rod length, work environment, or else. For quick ejector rod details, please contact your KOSMEK representative, visit the KOSMEK website at [http://www.kosmek.com], or refer to the quick ejector rod catalog. HEAD OFFICE BRANCH OFFICE (U.S.A.) MEXICO REPRESENTATIVE OFFICE BRANCH OFFICE (EUROPE) BRANCH OFFICE (INDIA) THAILAND REPRESENTATIVE OFFICE 1-5, 2-Chome, Murotani, Nishi-ku, Kobe 651-2241 TEL.+81-78-991-5162 FAX.+81-78-991-8787 KOSMEK (U.S.A.) LTD. 650 Springer Drive, Lombard, IL 60148 USA TEL. +1-630-620-7650 FAX. +1-630-620-9015 KOSMEK USA Mexico Office Blvd Jurica la Campana 1040, B Colonia Punta Juriquilla Queretaro,QRO 76230 Mexico TEL.+52-442-161-2347 KOSMEK EUROPE GmbH Schleppeplatz 2 9020 Klagenfurt am Wörthersee Austria TEL.+43-463-287587 FAX.+43-463-287587-20 KOSMEK LTD - INDIA F 203, Level-2, First Floor, Prestige Center Point, Cunningham Road, Bangalore -560052 India TEL.+91-9880561695 67 Soi 58, RAMA 9 Rd., Suanluang, Suanluang, Bangkok 10250 TEL. +66-2-300-5132 FAX. +66-2-300-5133 http://www.kosmek.com FOR FURTHER INFORMATION ON UNLISTED SPECIFICATIONS AND SIZES, PLEASE CALL US. SPECIFICATIONS IN THIS LEAFLET ARE SUBJECT TO CHANGE WITHOUT NOTICE. JQA-QMA10823 CAT.NO.MEK002-04-GB Printed in Japan KOSMEK HEAD OFFICE 2013. 03 First 1Ry 2017. 06 4th 1Ry