UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Similar documents
UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Design & Construction Standards, Revised January

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

1 Exam Prep NFPA 14 Stand Pipe Systems Questions and Answers (Plumbing Contractors)

DIVISION 21 FIRE SUPPRESSION

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

Western Michigan University Facilities Management Engineering Division

CONSTRUCTION REQUIREMENTS

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

New Construction Fire Inspection Process

Fire Protection System Impairment Procedure

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

MONTECITO FIRE PROTECTION DISTRICT

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)

Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System

McMAHON FP200 OUTAGAMIE COUNTY ADMINISTRATION CENTER S. WALNUT & W. 8TH, APPLETON, WI ALTERATION / ADDITION

I. Scope: II. Environmental Health and Safety Fire Alarm System Impairment Program - Guideline Revision Date: April, 2018

UBC Technical Guidelines Section Edition Fire Protection General Requirements Page 1 of 6

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

WALL ESCUTCHEON PIPE SEAL WITH APPROVED FIRE CAULKING (SEE SPECIFICATIONS) NOTE: 12" 12" 24"

Backflow Prevention for Fire Sprinkler Systems. State of Illinois Plumbing Code

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

Deluge/Preaction Systems Annotated Instructor s Guide

A. This section includes design and performance information for fire protection and suppression systems.

Deluge/Preaction Systems Annotated Instructor s Guide

Expectations (continued)

False Sense of Security???

5.07 Air Replenishment Systems

1 Exam Prep. Questions and Answers

Inspection of Fire Sprinkler Systems. NFPA 25, Inspection, Testing & Maintenance of Water Based Fire Protection Systems

SECTION : FIRE PROTECTION SYSTEMS

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT SERVICES UNIT CONTRATOR INFORMATION PACKET

Sprinkler Inspection Certificate

Winnipeg Fire Department Fire Prevention Branch

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

EXHIBIT D ATTACHMENT G - UNIT PRICING DMS-14/15-039B - SIMPLEXGRINNELL, LP FIRE SPRINKLER SYSTEM INSPECTIONS YEARS 1-5

PLAN REVIEW CHECKLIST

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

Global Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

FIRE SUPPRESSION SPRINKLER SYSTEM

2. Welding Materials and Procedures shall conform to the ASME Code.

CONSTRUCTION SERVICES GUIDE FOR UNIVERSITY OF FLORIDA FACILITIES

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers,

Safety Practices Fire Protection Equipment Cold Weather

Fire Sprinkler Submittal Requirements and Acceptance Testing

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review

FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT

FIRE SPRINKLER SYSTEMS POLICY

S a n F r a n c i s c o F i r e D e p a r t m e n t B u r e a u o f F i r e P r e v e n t i o n & I n v e s t i g a t i o n 1 of 8 P a g e

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

DIVISION 21 - FIRE SUPPRESSION

FIRE SPRINKLER SYSTEMS POLICY

9/15/ Cantara Lane Vista, CA (760)

Osceola County Department of Fire Rescue and Emergency Medical Services

Emergency Evacuation Plan. Tiffany Tower Plot W2 Jumeirah Lakes Towers

Quick Guide for Fire Sprinkler Inspection Requirements Key Deficiencies with NFPA References NFPA & NFPA 13/

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

DIVISION 21 - FIRE SUPPRESSION

SECTION WET-PIPE SPRINKLER SYSTEMS

Hot Work Policy and Procedures

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

OPERATION AND INSTRUCTION MANUAL NORCLEAN POWERED EDDY CURRENT VACUUM RECOVERY SYSTEM WITH WATER TRAP OPTION

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7

APPENDIX H (DESIGN SUBMISSION CRITERIA)

Environmental Health & Safety

Facilities Management

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

THE BASICS OF BUILDING FIRE PROTECTION DESIGN. RES Symposium April 18, 2017

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

Revised March 2015 Fire Alarm Systems Verification. Schedule I(A) Services. *Manditory Site visit required*

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

Gas Station & C Store SECTION CWM Job No

COURSE OUTLINE Fire Protection Systems

RESIDENTIAL MULTI-USE FIRE SPRINKLER SYSTEMS PERMIT SUBMITTAL REQUIREMENTS

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

SECTION : FIRE ALARM & DETECTION SYSTEMS

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

DUQUESNE UNIVERSITY. Fire Protection System Impairment Program (Red etag Permit)

SECTION WATER BASED FIRE SUPPRESSION SYSTEMS

ADDENDUM #1 ITB# Fire Protection Maintenance Services Responses to Clarification Questions 10/06/2015

Life Safety Plan Updated January 2017

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

SUMMARY. Building receiving sprinkler credit: SPRINKLERED. Grade: 68. Percent of Building Sprinklered: 100% Sprinkler Demand Met: 91%

UNIVERSITY. Facilities Management

PURPOSE OF THE PROCEDURE

Transcription:

Revision No.: 1 Page 1 of 5 I. PURPOSE This procedure identifies how to conduct a sprinkler system main drain test for ACF sprinkler system. This test requires two FSU personnel to complete. One in the fire pump room and one in WCC stairwell G-0700NW. II. PERSONNEL AFFECTED Fire Safety Unit (FSU) III. DEFINITIONS EH&S- Environmental Health and Safety Department of the University of Rochester Fire Safety Unit Representatives of the University Fire Marshal s Office out of the EH&S department. IV. RESPONSIBILITIES The Fire Safety Unit representative conducting this test is responsible for following the proper procedures related to these systems and for contacting Public Safety when the test begins and ends. Failure to do so may result in injury, damage or prevent the proper operation of equipment. V. PROCEDURES A. Contact the University Public Safety Communications Center and advise them you will be testing the sprinkler system main drain in ACF and WCC and to ignore water flow alarms from those fire alarm panels. B. Contact facilities work center (ext. 34567) and advise them you will testing the sprinkler system main drain in ACF and WCC. C. Disable ACF (room 1-1017) and WCC (room 1-0709) fire alarm panels per the fire alarm disconnect/reconnect procedures. D. Proceed to the ACF fire pump room (room G-1475A). E. Shut both the fire pump and the jockey pump off for the test per Fire Pump disconnect procedure. F. Close pet cock and remove the gauge from the supply side. Open pet cock and purge any excess debris/air from the port before installing the calibrated gauge.

Revision No.: 1 Page 2 of 5 G. Proceed to WCC G-0700 NW stairwell and open Butter fly valve FPV-04-G-0700NW and close Butter fly valve FPV-03-G-0700NW. Connect a short length of 2 ½ inch hose between the 2 valve off the stand pipe system to the valve for the discharge. Verify no one is sitting on the bench at the drain discharge outside the door from the stairwell. H. Open the 2 standpipe valve in G-0700NW stairwell to release the pressure from the weekly pump test to street pressure. Person in the fire pump room will monitor the pressure. I. Close the 2 standpipe valve. J. Observe and document the static pressure on the supply side and Start Test Time on Appendix 1. K. Open the 2 standpipe valve fully and watch the supply side calibrated pressure gauge to see how much lower the pressure drops. When the pressure stabilizes, note and document the residual pressure on Appendix 1. L. When the pressure gauge stops dropping and stabilizes, close the standpipe valve fully, note the time on Appendix 1 as Time Test Completed. M. Watch the calibrated gauge as it returns to match the actual street pressure and record static pressure and time on Appendix 1 under Time System Stabilized. N. The flow-testing portion is completed. O. The pressure should not drop 10%. If so, refer to Fire Marshal. Example: Street pressure is 60 psi X 10 % = 6 psi. The calibrated gauge should not drop past 54 psi during the stabilized timed flow test. P. In stairwell WCC G-0700 NW close Butter fly valve FPV-04-G-0700NW, and open Butter fly valve FPV-03-G-0700NW Q. Once the main drain is closed, turn the jockey pump back on and wait for the system pressure to return to normal. Caution: If the fire pump is turned on, it will activate and slam the system pressure quickly and possibly cause damage and/or multiple flow alarms. R. Remove the calibrated gauge from the street side. Open the pet cock and purge any excess debris/air from the port before re-installing the system gauge.

Revision No.: 1 Page 3 of 5 S. Complete the Main Drain-UR test form (Appendix 1). Turn this form into the Fire Marshal for review. T. Once the entire system pressure is returned to normal, turn the fire pump back on and return WCC (1-0709) and AC F (1017) fire alarm panels back to normal per the system disconnect/reconnect procedures. U. Contact the University Public Safety Communication Center and advise them the test is completed. V. Contact facilities work center (ext. 34567) and advise them the test is completed. VI. REFERENCES NFPA 25 (2014) Standard for Inspection, Testing and Maintenance of Water-Based Fire Protection Systems VII. APPENDICES/FORMS Appendix 1 (I:/fire/Main Drain/Main Drain Blank Form.xls) VIII. REVISION HISTORY Date Revision No. Description 4/18/2013 New Initial development of this policy 8/17/2017 1 Complete re-write

Revision No.: 1 Page 4 of 5 Appendix 1 DATE SYSTEM TEST POINT VALVE MODEL BUILDING LOCATION TEST FREQUENCY VALVE NUMBER TEST INFORMATION STATIC PRESSURES RESIDUAL PRESSURES PSI (BELOW CHECK VALVE) PSI (BELOW CHECK VALVE) SYSTEM FLUSHED PIPING SATISFACTORY SYSTEM INSPECTED VALVE OPERATED START TEST TIME STOP TEST TIME RECOVERY TIME FINAL STATIC PRESSURE SPRINKLER HEAD INFORMATION PSI TIME SYSTEM STABILIZED SPARE HEADS PROVIDED CHANGING TOOLS CLEAN OF DEPOSITS SPECIAL HEADS IDENTIFIED NUMBER OF HEADS PENDANT UPRIGHT PENDANT HEADS GREATER THAN 8' AFF HAVE CAGES

Revision No.: 1 Page 5 of 5 SPRINKLER SIGNAGE INFORMATION SIDEWALL SIGNAGE IDENTIFYING FLOW DIRECTION LABELS AREA ON PIPING OF PROTECTION HYDRAULIC CALCULATIONS FIRE DEPT CONNECTION ON RISER PROPERLY IDENTIFIED COMMENTS/CORRECTIVE ACTIONS INSPECTOR