SPRINKLER SYSTEMS DESIGN GUIDE AUTOMATED WATERING SYSTEMS FOR GREENHOUSE AND NURSERY

Similar documents
Sprinkler Systems Design Guide

Dan Fogger/Mister.

FOGGER INSTALLATION. com. www. NURSERY/GREENHOUSE. Reduce greenhouse temperatures, increase humidity levels or help promote propagation. SENNINGER.

N E T A F I M U S A. A Labor Saving. Drip System. for Watering. Potted Plants. 6Nf1AflM. IRRIGATl6N-MART ' GROW MOOE WITH LESS.

Hanging Basket Watering Systems

Tavlit solutions for Oil Palm Tree Irrigation

Simply drop into your water butt and use a hose and spray gun as easily as using the tap. Much easier than using a watering can!

Greenhouses. 4/25/2018 DUBI SEGAL

FREE How to get up and running using waterwise drip irrigation.

Lowering Application Intensity

DRIP IRRIGATION. Smart Water Use. Features & Benefits

com LOWER APPLICATION INTENSITY www. MECHANIZED IRRIGATION

DIY. Home Irrigation Installation Planner

Green Rope End Post Cap

OPTIMIZING PERFORMANCE IN SPRAY OPERATIONS

Atomizing Nozzle Humidifiers. Designed for Air Handling Systems, and Manufacturers, Processors and Distributors of Humidity Sensitive Products.

AKIMist E Dry Fog Humidifier General Installation Manual

DIY GUIDE.

Irrigation Tech II HYDRAULIC TROUBLESHOOTING

DuraSpray V Viton gaskets and seals. Model Industrial. DuraSpray

Low Pressure Sprinkler and Fan Cooling System Design for Dairy Facilities

Sprinkler Troubleshooting

WOBBLER TECHNOLOGY Irrigating Orchards and Groves

Casper Hoop House Workshop 12 Ft. x 36 Ft. Del Jimenez. 12ft x 36ft Hoop House 2

Irrigation for Lawns and Gardens

SMART Irrigation practices and NEW technology

The Intelligent Use of Water: Water Efficient System Overview

EVAPORATIVE COOLING AND HUMIDIFICATION. High-Pressure System Wetted Media System

Winter covers. tuboclima

Nursery Planning. Nursery Planning

Chapter 5. Editor. Ted W. van der Gulik, P.Eng. Senior Engineer. Authors. Stephanie Tam, P.Eng. Water Management Engineer

New. Products. 2017/2018 Season

Automatic Watering System. Easy Step-By-Step Planning and Installation Guide

Steam Injection Humidifiers for use with steam boilers PRODUCT CATALOG

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

FOGGING & HUMIDIFICATION PAPER STORAGE TEXTILE MILLS LIQUID STORAGE TANKS AIR DUCTS PRODUCE STORAGE ROOMS GREENHOUSES HATCHERIES CONCRETE PIPE CURING

FOGGING & HUMIDIFICATION PAPER STORAGE TEXTILE MILLS LIQUID STORAGE TANKS AIR DUCTS PRODUCE STORAGE ROOMS GREENHOUSES HATCHERIES CONCRETE PIPE CURING

Low Volume Irrigation

EXPRESS BOOM ASSEMBLY

Bringing water to life.

CHECKLIST BMPs for FIELD NURSERIES REGULATIONS, SITE SELECTION, WATER MANAGEMENT

High Pressure Fog System

CALU Nursery Stock Workshop Talgoed Nurseries, Conwy Valley 6 th February 2008

Creating A Waterwise Landscape. Conservation Garden Park South 1300 West West Jordan, UT

Name and affiliation of the author: Professor M M M Najim Department of Zoology and Environmental Management, University of Kelaniya

Uniform temperature in the root

CLIMATRON GROWTH CABINETS

Lecture-11. Plant propagation structures

6-7/8" 4" wide (cutout) 9-3/4" long. Optional Rough-in Brackets BR55 metal rough-in brackets are designed to claim the space during drywalling.

OUTDOOR COOLING PRODUCTS

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

PVC glue & SABA cleaner

EVAPORATIVE COOLING AND HUMIDIFICATION. High-Pressure System Wetted Media System

Cooling Systems for Georgia Dairy Cattle. Dr. John W. Worley, Extension Engineer

IRRIGATION METHODS for the Home Vegetable Garden

CLOSE SPACING LEPA BUBBLERS

MLVH MINI AUTOFOG CF COLDFOGGER

Drip Irrigation Kit Installation Manual

CI/SfB (11.1) (11.3) Common Arrangement R12. Uniclass D1372/L141. Trinter TM. Erosion Control Mat. Geosynthetics

HIGH-PRESSURE ATOMIZING SYSTEM. Humidification and adiabatic cooling. Energy efficient Reduces cooling load Multiple zone capabilities

in-bench PITCHER rinser installation intructions

PRODUCT CATALOGUE V1.3

DIVISION 32 EXTERIOR IMPROVEMENTS

18A GREENHOUSE ACCESSORIES. Sturdi-Built Greenhouse Mfg. Co., SW Boones Ferry Rd., Portland, OR 97219

Selecting the Right Sprayer

Steam Injection Humidifiers for use with steam boilers PR0DUCT CATALOG

COMMERCIAL & INDUSTRIAL Evaporative Air Conditioning Systems

GARLIC FARMING. Ecological Requirements

TECHNICAL DATA MODEL V-HIP SPECIFIC APPLICATION ATTIC SPRINKLER VK660

Eco- Tunnels. Sustain Your Health / Sustain Your Life

Greenhouse Temperature Management

MICRO IRRIGATION Installation Guide. Installation hints Wetta product guide Design your own irrigation system

CMG GardenNotes #714 Irrigating the Vegetable Garden. Garden Irrigation. Checking Soil Moisture Content

NEW GENERATION INTELLIGENT CHILLER BOOSTER, ADIABATIC PRE-COOLING SYSTEM

IRRIGATION EQUIPMENT LTD. The Perfect Solution for Water Filtration and Irrigation Problems

Cost Free Landscape Water Conservation Ideas

5 Selecting Sprinklers and Spacing Ranges

Introductory Vegetable Production Part 2. Growing Season Conditions CROP PRODUCTION / GROWING SEASON. Seeds vs. Transplants. Planting Considerations

OSCAR-LOWeFLOW Treatment System Design Manual January 2018

Braemar evaporative cooling So clever, so quiet, so cool

TABLE OF CONTENTS. MANUAL Standalone soilless barrel.

GARDENA Watering Systems 2012

173 Index of Materials

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

NEW GENERATION INTELLIGENT ADIABATIC PRE-COOLING SYSTEM

NILEATOR ATOR. Dyna-Fog ANILE. Cold Fog ULV Aerosol Applicator. Instruction Manual For Operation, Service and Maintenance

Portable Vacuum Systems and Accessories Developed with Innovative Features for Ease of Use High Quality Electric and Pneumatic Models

Installation Guide & Owner s Manual

DIFFERENT SPRAYERS AT A GLANCE

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

Management strategies for saline irrigation Considerations for citrus production

culus Listed: Category VNIV Refer to the Approval Chart on page 3. VK697 Attic Upright Sprinkler Specifications:

2shelving. 3cupboards & work stations. 4kinetic mobile shelving. 5technic shelving. 7cabinets

RP10 & GTS10 Systems 2. Septic Tanks & Grease Traps 4. OK1 Controllers, Pumps & Blowers 6. Recommended Service Spare Parts 7-8

USE OF A LOWER RATE WHEN APPLIED ON CEREALS AT THE HERBICIDE TIMING (FEEKES 4-6) - AL, AR, AZ ETC.

PIPE DREAMS 96. Aeroponic Garden IMPORTANT:

for the Programmable Humidifier Automatic Flushing Timer

DIVISION 32 EXTERIOR IMPROVEMENTS

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

Transcription:

SPRINKLER SYSTEMS DESIGN GUIDE AUTOMATED WATERING SYSTEMS FOR GREENHOUSE AND NURSERY

NETAFIM S SPRINKLERS GIVING YOU UNIFORM COVERAGE SpinNet Sprinkler VibroNet Sprinkler CoolNet Pro Superfine Mister (Grey Nozzles) 1

WHY NETAFIM SYSTEMS ARE BETTER UV WHITE PE TUBING Clean look and cooler water temperature STABILISER WEIGHT Keeps sprinkler plumb SUPER FLEX UV WHITE PE TUBING Soft, flexible 4 x 6.5mm white tubing LOW COST AND FAST PAYBACK Payback for a complete system is usually within the first season of operation. DRIP-LESS SPRINKLERS SpinNet Sprinkler offers drip-less operation - the plants below are not damaged from water dripping off the sprinkler. Check Valve prevents the sprinkler line from draining onto the plants below after shut-down and provides instantaneous on-off for accurate short cycle watering and misting. Sprinklers hang below the supply pipe, preventing wetting of the pipe and dripping onto the plants below. HIGHLY UNIFORM WATERING Increases crop uniformity. SD DEVICE Shoulder distribution MISTER, SPRAYER, SPINNER Determines wetted patterns AD (ANTI DRAIN) VALVE Prevents line drainage; provides instantaneous on-off HIGHLY DURABLE Made from the highest quality plastics with excellent Ultra-Violet (UV) resistance. Our reflective co-extruded white tubing is completely opaque to prevent algae growth, UV resistant, and can withstand heat, direct sun and harsh chemicals. LOW MAINTENANCE All sprinkler parts can be assembled and disassembled in the greenhouse without tools. Dry Area Wet Area UNIFORM COVERAGE Traditional sprinkler layout spaces the sprinklers head to head or at a spacing equal to the radius of the sprinkler throw. For larger areas, the patterns are overlapped creating both wet and dry areas. Traditional Head to Head sprinkler overlap. Inconsistant coverage patterns. Netafim two line solution. Uniform Coverage. The Netafim solution avoids the problems of the traditional sprinkler layout and achieves a high level of uniformity within a closely spaced strip of sprinklers. By designing with these strips laid out side by side, large areas can be covered uniformly. 1

DESIGN GUIDE FOR SPRINKLER & MISTING SYSTEMS STEP 1 VISUALIZE THE GREENHOUSE Evaluate the location of obstacles such as curtains or hanging baskets. Consider aisles and whether they can be wetted. Review cultural practices which might impact the height at which the sprinklers should be placed. STEP 2 SELECT A SPRINKLER HEAD FOR WATERING APPLICATIONS GO TO STEP 3 (PAGE 4) FOR MISTING, PROPAGATION OR COOLING APPLICATIONS All sprinkler solutions are based on an average sprinkler working pressure of 200 kpa and spacing between the sprinklers of 0.9m. SINGLE BENCH with VibroNet sprinklers BENCH WIDTH SPACING BETWEEN SPRINKLERS HEIGHT ABOVE CROP M M 0.6-0.9M 0.90-1.5M 1.2 0.9 VN-BL or VN-GN VN-BL or VN-GN 1.5 0.9 VN-BL or VN-GN VN-BL or VN-GN 1.8 0.9 VN-BL or VN-GN VN-BL or VN-GN ONE LINE For single bay or tunnel with SpinNet sprinklers SPACING BETWEEN BAY WIDTH SPRINKLERS HEIGHT ABOVE CROP M M 0.6-0.9M 1.2-1.5M 1.8-2.1M 3.0 0.9 R-R-BL - - 3.6 0.9 R-R-BL R-R-BL - 4.2 0.9 BR-BR-BL BR-BR-BL R-R-BL 4.6 0.9 R-R-GY BR-BR-BL R-R-BL 4.9 0.9 R-R-GY BR-Y-GY R-R-BL 5.5 0.9 R-R-GN BR-Y-GY BR-Y-GY 6.1 0.9 - R-R-GN BR-BR-GN 6.7 0.9 - R-R-GN BR-BR-GN 7. 3 0.9 - - BR-BR-GN 2

TWO LINES For single bay or tunnel with SpinNet sprinklers BAY WIDTH SPACING BETWEEN SPRINKLERS SPACE BETWEEN SPRINKLER LINES HEIGHT ABOVE CROP M M M 0.6-0.9M 1.2-1.5M 1.8-2.1M 6.1 0.9 3.3 R-R-BL - - 6.7 0.9 3.6 R-R-BL R-R-BL - 7.3 0.9 3.6 R-R-BL R-R-BL R-R-BL 7.9 0.9 4.2 BR-BR-BL R-R-BL R-R-BL 8.5 0.9 4.6 BR-BR-BL R-R-BL R-R-BL 9.1 0.9 4.9 R-R-GY R-R-GY BR-BR-BL 9.7 0.9 5.2 R-R-GN R-R-GY BR-BR-BL 10.3 0.9 5.5 R-R-GN R-R-GY BR-BR-BL 11.0 0.9 5.8 R-R-GN R-R-GY R-R-GN 11.6 0.9 6.1 BR-BR-GN R-R-GN R-R-GN SPINNET SPRINKLER AD Valve ORDERING GUIDE QUICK CODE TYPE DESCRIPTION FLOW RATE VN-BL VibroNet Blue Nozzle 40 VN-GN VibroNet Green Nozzle 50 L/HR R-R-BL SpinNet Red SD, Red Nozzle, Blue Low Trajectory swivel 70 SD (Shoulder Distributor) Nozzle Body Swivel BR-BR-BL SpinNet Brown SD, Brown Nozzle, Blue Low Trajectory swivel 90 R-R-GY SpinNet Red SD, Red Nozzle, Grey Flat Trajectory swivel 70 BR-Y-GY SpinNet Brown SD, Yellow Nozzle, Grey Flat Trajectory swivel 90 R-R-GN SpinNet Red SD, Red Nozzle, Green High Trajectory swivel 70 BR-BR-GN SpinNet Brown SD, Brown Nozzle, Green High Trajectory swivel 90 All of the above require a 63000-003000 = AD Valve (Purple pin) 2 Bar opening pressure WHICH ONE TO ORDER CODE SD AD VALVE SPRINKLER HEAD VN-BL - 63000-003000 64300-001000 VN-GN - 63000-003000 64300-005000 R-R-BL 63000-014300 63000-003000 64200-026000 BR-BR-BL 63000-014350 63000-003000 64200-027000 R-R-GY 63000-014300 63000-003000 64200-007000 BR-Y-GY 63000-014350 63000-003000 64200-008000 R-R-GN 63000-014300 63000-003000 64200-017500 BR-BR-GN 63000-014350 63000-003000 64200-020000 3

DESIGN GUIDE FOR SPRINKLER & MISTING SYSTEMS STEP 3 SELECT A SPRINKLER HEAD FOR MISTING, PROPAGATING & COOLING APPLICATIONS VIBRONET SPRINKLER FOR MISTING LARGER AREAS The VibroNet sprinkler with blue nozzle is used when a light mist is required for watering, for example when germinating seeds. Excellent uniformity can be achieved with sprinkler spacings between 0.9m - 1.5m, with an elevation of 0.6m to 1.5m. The VibroNet sprinkler can be used upright or upside down. PART NUMBER DESCRIPTION FLOW RATE L/HR 64300-001000 VibroNet Sprinkler with Blue Nozzle 40 64300-005000 VibroNet Sprinkler with Green Nozzle 50 COOLNET PRO SUPERFINE MISTER FOR PROPAGATION & HUMIDITY CONTROL The CoolNet Pro superfine mister is the best nozzle for propagation. It creates a zone of saturated humidity that is ideal for rooting. Average droplet size is 65 micron at 4 Bar. refer to pages 8-9 for recommendations on how to use this product for propagation (humidifying) and cooling. PART NUMBER DESCRIPTION FLOW RATE L/HR 63100-058300 CoolNet Pro Sprinkler x4 Grey Nozzles 30 (4 x 7.5L/Hr) 4

STEP 4 SELECT A SPRINKLER BASE Netafim offers a selection of three bases to connect the sprinkler, mister or superfine mister to the supply pipe. HANGING SPRINKLER ASSEMBLY Used for connection to Polyethylene (PE) Tubing with Netafim sprinklers, misters and superfine misters. PART NUMBER DESCRIPTION 63000-003570 15cm Dropper assembly with Stabiliser 63000-004060 30cm Dropper assembly with Stabiliser 63000-004450 46cm Dropper assembly with Stabiliser 63000-005860 60cm Dropper assembly with Stabiliser 63000-007160 90cm Dropper assembly with Stabiliser 63000-008350 120cm Dropper assembly with Stabiliser VibroNet Sprinkler 1/2 Adaptor 1/2 ADAPTER Used for connection to rigid pipe with 1/2 threaded connections and Netafim sprinklers. RETROFIT ADAPTER Used to connect Netafim sprinklers and superfine misters to other manufacturer s fittings. PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION 63000-001200 1/2 BSPF to F Press fit 63000-002510 Retrofit adaptor suitable for Mini sprinklers 5

DESIGN GUIDE FOR SPRINKLER & MISTING SYSTEMS STEP 5 SIZE THE SPRINKLER SUPPLY PIPE Netafim UV White PE tubing offers a cool look, cooler water temperature and enhanced plant growth. Use the chart below to select the correct sprinkler supply size. Low density polyethylene is strongly recommended. POLY PIPE SIZING (mm) SPRINKLER NOZZLE FLOW RATE LENGTH OF SPRINKLER SUPPLY PIPE COLOUR L/PH 7.5M 15M 22M 30M 38M 45M CoolNet Pro Grey 30 19mm 19mm 19mm 19mm 19mm 19mm VibroNet Blue 40 19mm 19mm 19mm 19mm 19mm 19mm VibroNet Green 50 19mm 19mm 19mm 19mm 25mm 25mm SpinNet Nozzle/SD Red/Red 70 19mm 19mm 19mm 25mm 25mm 25mm SpinNet Nozzle/SD Brown/Brown 90 19mm 19mm 19mm 25mm 25mm 32mm SpinNet Nozzle/SD Yellow/Brown 90 19mm 19mm 19mm 25mm 25mm 32mm STEP 6 SIZE THE DISTRIBUTOR AND MAINLINE The remaining piping and system components are sized based upon the maximum flow they will receive. Use the Flow Per Sprinkler Line chart to determine the flow of a single sprinkler supply pipe for the length of run in your design. If more than one sprinkler line will be operated at once, be sure to multiply the flow by the number of lines when sizing the system pipes and components. Pipe size recommendations are guidelines only. For distributor lines over 12m, mainlines over 30m or when slopes are a factor, please consult a design professional. DISTRIBUTOR AND MAINLINE PIPE SIZING PIPE SIZE MAXIMUM* INCHES MM L/PH 1/2 15 1,350 3/4 20 2,200 1 25 3,800 1 1/4 32 6,000 1 1/2 40 8,000 2 50 12,000 *Assumes PVC Class 12 and 1.5 m per second water velocity 6 FLOW PER SPRINKLER LINE (LPH) AVERAGE SPRINKLER NOZZLE FLOW COLOUR LPH 7.5M (9) LENGTH OF SPRINKLER SUPPLY PIPE #1 (NUMBER OF SPRINKLERS #2) CoolNet Pro Grey 30 270 510 750 1,020 1,260 1,500 VibroNet Blue 40 360 680 1,000 1,360 1,680 2,000 VibroNet Green 50 450 850 1,250 1,700 2,100 2,500 SpinNet Nozzle/SD Red/Red 70 630 1,190 1,750 2,380 2,940 3,500 SpinNet Nozzle/SD Brown/Brown 90 810 1,530 2,250 3,060 3,780 4,500 SpinNet Nozzle/SD Yellow/Brown 90 810 1,530 2,250 3,060 3,780 4,500 #1 Based on Poly Pipe Sizing (mm) Chart Above. #2 - Sprinklers spaced at 0.9m 15M (17) 22M (25) 30M (34) 38M (42) 45M (50)

STEP 7 SIZE THE HEAD CONTROL COMPONENTS The components should be sized according to the flow range shown in the Filter, Valve & Pressure Regulator sizing chart (see below). The pipe connecting to the components can be of a different size. FILTER & VALVE SIZING FILTER & VALVE MAXIMUM FLOW UNIT SIZE CODE L/PH Electric Valve AC 5,500 3/4 (20mm) Globe 71640-007320 Electric Valve AC 10,000 1 (25mm) Globe 71640-007390 Electric Valve AC 24,000 1 1/2 (40mm) Globe 71640-007530 Electric Valve AC 40,000 2 (50mm) Globe 71640-001650 Disc Filter 2,500 3/4 (20mm) 70640-001200 Disc Filter 4,500 1 (25mm) 70640-002090 Disc Filter 9,000 1 1/2 (40mm) Super 70640-003400 Disc Filter 20,000 2 (50mm) Leader 70640-005340 Disc Filter 20,000 2 (50mm) Dual 70640-004700 Disc filter is 120 Mesh/130 Micron PRESSURE REGULATOR SIZING PRESSURE REGULATOR FLOW RANGE UNIT SIZE CODE LPH Pressure Regulator 25m spring 800-4,500 Planet 3/4 (20mm) 30500-001600 1,600-9,000 Planet 1 1/2 (40mm) 30520-001600 3,200-18,000 Planet 2 (50mm) 4 Port 30540-001600 FLOW CONTROL HEAD ASSEMBLY ORDER: 1. VALVE 2. FILTER 3. PRESSURE REGULATOR *Size of components vary based on flow rate. Valve Filter Pressure Regulator STEP 8 STARTING UP A SYSTEM FOR THE FIRST TIME The most important point to remember when starting up a new system is to flush the mainlines. Debris from construction can otherwise be washed into the sprinklers, causing a plug or improper operation. To properly flush a system, first connect all the pipes and assemblies, except the sprinklers with Check Valves. Next, open the ends of the distributor line and the sprinkler supply pipes. Close them off, one by one, starting with the opening closest to the head control, and proceeding to the most distant opening. Only after complete flushing should the sprinklers with Check Valves be attached to the assemblies. 7

COOLNET PRO SUPER FINE MISTER INSTALLATIONS PROPAGATION BENCHES INFORMATION Space between CoolNet Pro sprinklers 0.9m 0.9M TO 1.2M BENCH The height of the superfine mister assembly should be 0.45m to 0.75m above the propagation material. The distance between the superfine mister assemblies should be 0.9m. (Place the lateral above the centre of a 0.9m to 1.2m bench.) WIDE BENCH For wide benches (up to 2.4m) use two lines of superfine misters equally distanced from the center of the bench. For large areas, use one row of superfine misters for every 1.2m width of area to be misted. Height above tables 0.45-0.75m 45 OFFSET 4-way crosses should be placed at 45 angles to one another. Above head view of single row of CoolNet Pro Sprinklers. Above head view of dual rows of CoolNet Pro Sprinklers. 8

COOLNET PRO SUPER FINE MISTER INSTALLATIONS HUMIDIFICATION AND COOLING INFORMATION COOLING CONSIDERATIONS INCLUDE: Place the CoolNet Pro sprinkler as high as possible Avoid spraying against the roof or structure Prevent precipitation by adjusting the cycle time Space between units 0.9-3.0m GENERAL SPACING AND OPERATION FOR HUMIDIFYING AND COOLING Height above tables 1.2m (generally higher is better) Space between lines 2.0-4.0m Distance Between CoolNet units (m) 0.9 1.5 2.0 3.0 2.0 3.0 Distance Between Laterals (m) 2.0 3.2 3.0 3.0 4.0 4.0 CoolNet 4 x 7.5 L/Ph Pulse time (sec) 1 3 5 10 20 30 CoolNet 4 x 7.5 L/Ph Interval time (sec) 74 91 120 150 355 345 GENERAL SPACING AND OPERATION CONSIDERATIONS INCLUDE: In order to maximize the cooling effect, exhaust fans are recommended to exchange the air about 20 times per hour. These recommendations are general and should be applied in accordance with local conditions and limitations. Duration of pulse and interval is to be fine-tuned according to local conditions; the timing provided is just a starting point. For crops that are not sensitive to wetting, the pulse can be prolonged, and/or the interval shortened. Other spacing can certainly be used with CoolNet Pro; the spacings above give some reference points between spacing and operation intervals. 9

WWW.NETAFIM.COM.AU WWW.NETAFIM.CO.NZ NETAFIM SPRINKLER SYSTEM DESIGN GUIDE FEBRUARY 2018