Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Similar documents
RGE 13 A T - 1 A

13 GEP A L P - 1 A

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal

15CHPX. DAVE LENNOX SIGNATURE COLLECTION Residential - R-410A - Variable Speed Blower

MERIT SERIES Up Flow / Horizontal

2 shp 13 lc 1 36 t - 1 a

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

Corp L2 Revised

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

T P A 120 S 4 S N 1 Y

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

TECHNICAL SPECIFICATIONS

T CLASS ROOFTOP UNITS 60HZ Bulletin No July 2008 Supersedes August 2007

TECHNICAL SPECIFICATIONS

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

PRPDF16 PRODUCT SPECIFICATIONS PRP DF P A SINGLE STAGE GAS VALVE TWO STAGE COMPRESSOR VARIABLE SPEED BLOWER

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Commercial High-Efficiency Condensing Units

UNIT INFORMATION. Corp L7. Gauge Manifold Attachment... Page 30 Parts Arrangement... Page 8

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

Visit us at For the latest technical information,

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

High Heat COP. High/Low Stage

TGA WARNING CAUTION ROOFTOP UNITS. Service Literature. Table of Contents

PAJ3. Product Specifications

50TM TFF COMBINATION HEATING/COOLING UNITS

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

50TM COMBINATION HEATING/COOLING UNITS

MERIT SERIES Downflow

Lennox 8 Series Single Zone - R-410A

PAR5. Product Specifications

T S A 048 S 4 N 4 1 T

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

MACH N-407 Heat Pump Air-Cooled Chiller

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

V8MS Mode Selection Box for VRA Heat Recovery - 60HZ

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

48PGD/E/F/L/M/N PG20-28

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

Product Data. Fig. 1 - Unit 50VR -A

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

ELITE SERIES Downflow - High Efficiency Blower Motor

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Commercial High-Efficiency Condensing Units

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

DAVE LENNOX SIGNATURE COLLECTION WITH SILENTCOMFORT TECHNOLOGY

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

HIGH EFFICIENCY AIR HANDLER

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

4YCC3048A3096A /3/ /

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

14 AC x

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PACKAGE AIR CONDITIONER

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

CB X 32 mv

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

TECHNICAL SPECIFICATIONS

DCG Commercial. Submittal Data Form

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Bosch BVA Series Air Handler

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

Transcription:

PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type HPP = Packaged Heat Pump SEER - 3.00 to 5 Tons Cooling Capacity - 3,000 to 56,000 Btuh Heating Capacity -,600 to 54,000 Btuh Optional Electric Heat - 5 to 0 kw 3 HPP 36 A P - A Service Level Minor Revision Number Nominal Cooling Capacity 4 = tons 30 =.5 tons 36 = 3 tons 4 = 3.5 tons 48 = 4 tons 60 = 5 tons Voltage 30 = 08/30V-phase-60hz Major Design Sequence A = st Generation 3-PHASE MODELS Unit Type RHP = Packaged Heat Pump RHP 3 A 36 T - A Service Level Nominal SEER Series A = st generation Nominal Cooling Capacity 36 = 3 tons 48 = 4 tons 60 = 5 tons Minor Revision Number Voltage T = 08/30V-3phase-60hz F = 460V-3phase-60hz

FEATURES CONTENTS Accessories Dimensions... Blower Data...9 Cooling Ratings...8 Dimensions... Electrical Data - -Phase...4 Electrical Data - 3-Phase...5 Electric Heat Data...7 Features... Heating Ratings...8 Installation Clearances...3 Model Number Identification... Options / Accessories...6 Specifications - -Phase Models...4 Specifications - 3-Phase Models...5 WARRANTY NOTE - Warranty below for 3HPP models refers to non-residential applications. Compressor - Five year limited warranty. All other covered components - One year. APPROVALS AHRI Certified to AHRI Standard 0/40-008. ETL listed. Units are Certified by AHRI. Packaged unit and components within bonded for grounding to meet safety standards required by ETL. Optional electric heaters are UL listed for the U.S. and Canada and are rated and tested according to DOE test procedures and FTC labeling regulations. Each unit test operated at the factory before shipment ensuring dependable operation at start-up. APPLICATIONS Designed for outdoor installations at ground level or rooftop applications. SUPPLY AIR BLOWER Direct Drive Blower Each blower assembly statically and dynamically balanced. Multi-speed, direct drive blower motor. Change in blower speed is easily accomplished by simple wiring change on blower motor. Blower assembly easily removed for servicing. See Blower Performance tables. REFRIGERATION SYSTEM R-40A Refrigerant Non-chlorine, ozone friendly, R-40A. Unit pre-charged with refrigerant. See Specifications table. Indoor and Outdoor Coils Copper tube with aluminum fin coils. Indoor Coil Drain Pan Corrosion resistant plastic drain pan. Outdoor Coil Fan Weather protected heavy duty outdoor coil fan motor with coated steel fan blades for long life. Internally mounted. Totally enclosed motor. Fan guard constructed of corrosion-resistant coated steel. Reversing Valve 4-way interchange reversing valve effects a rapid change in direction of refrigerant flow resulting in quick changeover from cooling to heating and vice versa. High Pressure Switch Shuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting. Protects compressor from excessive condensing pressure. Automatic reset. CONTROLS Electronic blower control. Single pole contactor (3HPP models). 3-Pole Double-Break Contactor (RHP3 models). Trade available components. Defrost Control Defrost control furnished as standard equipment. Gives a defrost cycle for every 30, 60, or 90 minutes (adjustable) of compressor on time at outdoor temperatures below 35 F. Field-selectable, quiet shift setting reduces compressor noise during the defrost cycle. Sensor mounted on liquid line determines when defrost cycle is required and also when to terminate cycle. Anti-short cycle, timed-off control incorporated into the board. 4 Volt Transformer 40VA transformer furnished and factory installed in control area. Options / Accessories Thermostat See Thermostat bulletins in Controls section and Lennox Price Book for a complete list of thermostats. 3HPP-RHP3 - to 5 Ton Packaged Heat Pumps / Page

FEATURES COMPRESSOR Scroll compressor on all models. Overload protected. Resiliently mounted on rubber mounts. CABINET Conditioned areas insulated with foil faced insulation to minimize heat loss and reduce operating sound levels. Powder paint for maximum durability. Easy service access. Coated steel wire guard provides complete coil protection. Interchangeable panels for horizontal to downflow airflow conversion furnished (shipped for horizontal). Three-Phase Models Only - Factory installed wiring harness for optional Economizer allows fast and easy electrical connections. Economizer must be field wired when used with single phase models. AIR FILTER (not furnished - required) Filter rails for mounting inch filter are furnished in cabinet. Filter is not furnished and must be field provided. See Specifications Table for sizes. OPTIONS / ACCESSORIES ROOF CURB Roof Curb, Downflow Nailer strip furnished, mates to unit, shipped knocked down. See dimension drawing. ECONOMIZER Downflow or horizontal, parallel gear-driven action return air and outdoor air dampers, plug in connections to unit, nylon bearings, neoprene seals, 4-volt, fullymodulating, spring return motor, adjustable minimum damper position. Barometric relief dampers furnished in downflow economizer. NOTE - Downflow economizer is not available for 3HPP48 and 3HPP60 single-phase models. ELECTRIC HEAT Field install internal to unit cabinet. Available in several voltages and kw sizes. Helix wound nichrome heating elements exposed directly in air stream resulting in instant heat transfer, low element temperatures and long service life. Cutoff limit control provides positive protection in case of excessive temperatures. Easy plug-in connections for low voltage control wiring. OUTDOOR AIR DAMPER Manual or motorized. Perforated air intake panel replaces existing duct cover on unit. 0 to 5% (fixed) Manual outdoor air damper has adjustable damper slide. Motorized outdoor air damper has motorized damper assembly with adjustable damper slide. Outdoor air hood with cleanable filter included. INSTALLATION CLEARANCES in. mm Front (electric heat access) 4 60 Right Side (blower access) 4 60 Left Side (indoor coil access) 4 60 Back 0 0 Top 48 9 3HPP-RHP3 - to 5 Ton Packaged Heat Pumps / Page 3

SPECIFICATIONS - -PHASE MODELS General Data Model No. 3HPP4A 3HPP30A 3HPP36A 3HPP4A 3HPP48A 3HPP60A Cooling Performance Heating Performance (High Temp) Heating Performance (Low Temp) Nominal Tonnage.5 3 3.5 4 5 Total capacity - Btuh 3,000 8,000 34,600 40,000 46,000 56,000 Total unit watts 090 545 345 3636 48 5090 SEER (Btuh/Watt) 3.00 3.00 3.00 3.00 3.00 3.00 EER (Btuh/Watt).00.00.00.00.00.00 Total capacity - Btuh,600 7,000 33,600 39,000 44,000 54,000 Total unit watts 80 6 85 3363 390 4798 COP 3.5 3..5 3.5 3.4 3.3 3.3 HSPF Region IV 7.7 7.7 7.7 7.7 7.7 7.7 Total capacity - Btuh 3,000 6,000 0,00,400 6,800 34,000 Total unit watts 733 040 575 985 374 4335 COP..3.3...3 Sound Rating Number (db) 77 77 77 80 80 80 Refrigerant Type R-40A R-40A R-40A R-40A R-40A R-40A Charge 5 lbs. 0 oz. 7 lbs. 3 oz. 7 lbs. 6 oz. 8 lbs. 4 oz. 9 lbs. 0 oz. 9 lbs. 6 oz. Condensate drain size (fpt) - in. 3/4 3/4 3/4 3/4 3/4 3/4 Outdoor Coil Fan Motor horsepower /4 /4 /4 /3 /3 /3 Diameter - in. & No. of blades 8-4 8-4 8-4 - 3-3 - 3 Indoor Blower Blower wheel size dia. x width - in. 0 x 8 0 x 8 0 x 8 0 x 0 0 x 0 0 x 0 5 Filter Dimensions (filter and rails not furnished) Motor horsepower / / / 3/4 3/4 3/4 () 4 x 8 x () 30 x 30 x Net weight of basic unit - lbs. 35 35 35 447 455 455 Shipping weight of basic unit ( Pkg.) - lbs. 338 365 365 46 470 470 Electrical characteristics (60 hz) ELECTRICAL DATA - -PHASE 08/30V-ph-60hz Line voltage data - 60hz phase 08/30V 08/30V 08/30V 08/30V 08/30V 08/30V 3 Maximum overcurrent protection (amps) 30 30 35 45 50 60 4 Minimum Circuit Ampacity.3.3 6. 30.4 34.7 40.5 Compressor Rated load amps.8.8 6.6 8.3.8 6.4 Locked rotor amps 58.3 64 79 7 34 Outdoor Coil Fan Motor Full load amps....7.7.7 Indoor Blower Motor Full load amps 4. 4. 4. 5.8 5.8 5.8 NOTE-Extremes of operating range are plus and minus 0% of line voltage. AHRI Certified to AHRI Standard 0/40 Cooling Ratings - 95 F outdoor air temperature and 80 F db/67 F wb entering indoor coil air. High Temperature Heating Ratings - 47 F db/43 F wb outdoor air temperature and 70 F entering indoor coil air. Low Temperature Heating Ratings - 7 F db/5 F wb outdoor air temperature and 70 F entering indoor coil air. Sound Rating Number rated in accordance with test conditions included in AHRI Standard 70. 3 HACR type circuit breaker or fuse. 4 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 5 Filters are not furnished and must be field provided. 3HPP-RHP3 - to 5 Ton Packaged Heat Pumps / Page 4

SPECIFICATIONS - 3-PHASE MODELS General Data Model No. RHP3A36 RHP3A48 RHP3A60 Cooling Performance Heating Performance (High Temp) Heating Performance (Low Temp) Nominal Tonnage 3 4 5 Total capacity - Btuh 34,600 46,000 56,000 SEER (Btuh/Watt) 3.0 3.0 3.0 EER (Btuh/Watt).0.0.0 Total capacity - Btuh 33,600 44,000 54,000 COP 3.5 3.3 3.3 HSPF Region IV 7.7 7.7 7.7 Total capacity - Btuh 0,00 6,800 34,000 COP.3..3 Sound Rating Number (db) 79 80 80 Refrigerant Type R-40A R-40A R-40A Charge 7 lbs. 6 oz 9 lbs. 0 oz. 9 lbs. 6 oz. Condensate drain size (fpt) - in. 3/4 3/4 3/4 Outdoor Coil Fan Motor horsepower /4 /3 /3 Motor rpm 075 075 075 Diameter - in. & No. of blades 8-4 - 3-3 Indoor Blower Motor horsepower / 3/4 3/4 Blower wheel size dia. x width - in. 0 x 8 0 x 0 0 x 0 5 Filter Dimensions (filter not furnished) () 4 x 8 x () 30 x 30 x () 30 x 30 x Shipping weight of basic unit ( Pkg.) - lbs. 370 480 480 Electrical characteristics (60 hz) ELECTRICAL DATA - 3-PHASE 08/30V-3ph or 460V-3ph Line voltage data - 60hz 3 phase 08/30V 08/30V 460V 08/30V 460V 3 Maximum overcurrent protection (amps) 5 35 5 40 0 4 Minimum Circuit Ampacity 8.3 4.6 7.4 3.9 Compressor Rated load amps 0.4 3.7 6. 5.9 7.7 Locked rotor amps 73 83. 4 0 5 Outdoor Coil Fan Motor Full load amps..7.7 Indoor Blower Motor Full load amps 4. 5.8 3. 5.8 3. NOTE-Extremes of operating range are plus and minus 0% of line voltage. AHRI Certified to AHRI Standard 0/40 Cooling Ratings - 95 F outdoor air temperature and 80 F db/67 F wb entering indoor coil air. High Temperature Heating Ratings - 47 F db/43 F wb outdoor air temperature and 70 F entering indoor coil air. Low Temperature Heating Ratings - 7 F db/5 F wb outdoor air temperature and 70 F entering indoor coil air. Sound Rating Number rated in accordance with test conditions included in AHRI Standard 70. 3 HACR type circuit breaker or fuse. 4 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 5 Filters are not furnished and must be field provided. 3HPP-RHP3 - to 5 Ton Packaged Heat Pumps / Page 5

OPTIONS / ACCESSORIES Item Description Model Number Catalog Number Unit Model No 4 30 36 4 48 60 electric heat -Phase 5 kw 08/40V-ph-60hz AHSA05A- 40K65 X X X X X X 7 kw 08/40V-ph-60hz AHSA07A- 40K66 X X X X X X 0 kw 08/40V-ph-60hz AHSA0A- 40K67 X X X X X X 5 kw 08/40V-ph-60hz AHSA5A- 40K68 X X X X X X 0 kw 08/40V-ph-60hz AHSA0A- 40K69 X X X 3-Phase 0 kw 08/40V-3ph-60hz AHSA0B-.8007 X X X 460V-3ph-60hz AHSA0C-.804 X X 5 kw 08/40V-3ph-60hz AHSA5B-.8008 X X X 460V-3ph-60hz AHSA5C-.805 X X ECONOMIZER Downflow AECON85-.85395 X X X AECON86-.85396 X X X Horizontal AECON87-.85397 X X X AECON88-.85398 X X X OUTDOOR AIR DAMPER Manual ADMPR45-.8574 X X X ADMPR66-.8593 X X X Motorized ADMPR46-.8575 X X X ADMPR67-.8594 X X X ROOF CURBS ACURB6-.8599 X X X ACURB63-.85300 X X X NOTE - Catalog and model numbers shown are for ordering field installed accessories. X = Field installed. Optional for three-phase models only. 3HPP-RHP3 - to 5 Ton Packaged Heat Pumps / Page 6

ELECTRIC HEAT DATA -PHASE Packaged Unit Model No. Electric Heat Size Input Minimum Circuit Ampacity Minimum Circuit Ampacity Maximum Overcurrent Protection Maximum Overcurrent Protection kw Catalog No. Volt kw Circuit Circuit Circuit Circuit 3HPP4A 3HPP30A 3HPP36A 3HPP4A 3HPP48A 3HPP60A 3-PHASE RHP3A36 5 kw 40K65 7 kw 40K66 0 kw 40K67 5 kw 40K68 5 kw 40K65 7 kw 40K66 0 kw 40K67 5 kw 40K68 0 kw 40K69 0 kw.8007 5 kw.8008 40 5.0 3. - - - 35 - - - 08 3.7 7.8 - - - 30 - - - 40 7.0 4.7 - - - 50 - - - 08 5..3 36.8 - - - 40 - - - 40 0.0 57.3 - - - 60 - - - 08 7.5 50.3 - - - 60 - - - 40 5.0 57.3 6 60 30 08.3 50.3.5 60 5 40 5.0 33.3 - - - 35 - - - 08 3.7 9.9 - - - 30 - - - 40 7.0 43.8 - - - 50 - - - 08 5..3 38.9 - - - 40 - - - 40 0.0 59.4 - - - 60 - - - 08 7.5 5.4 - - - 60 - - - 40 5.0 59.4 6 60 30 08.3 5.4.5 60 5 40 0.0 59.4 5. 60 60 08 5.0 5.4 45. 60 50 08 7.5 3. 35 - - - - - - 40 0.0 35. 40 - - - - - - 08.3 44. 45 - - - - - - 40 5.0 50. 60 - - - - - - 0 kw.8007 08 7.5 33.3 35 - - - - - - 40 0.0 37.3 40 - - - - - - RHP3A48 RHP3A60 5 kw.804 480 0.0 9.0 0 - - - - - - 08.3 46.3 50 - - - - - -.8008 40 5.0 5.4 60 - - - - - -.805 480 5.0 5.8 30 - - - - - - Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. HACR type breaker or fuse. 3HPP-RHP3 - to 5 Ton Packaged Heat Pumps / Page 7

COOLING RATINGS Model 3HPP4A 3HPP30A 3HPP36A RHP3A36 3HPP4A 3HPP48A RHP3A48 3HPP60A RHP3A60 Indoor Temp DB/WB ºF Outdoor Temp - DBºF 65 8 95 05 5 Btuh S/T kw Btuh S/T kw Btuh S/T kw Btuh S/T kw Btuh S/T kw 85/7 8,00 0.59.60 6,500 0.6.89 5,300 0.65.0 3,700 0.68.33,800 0.7.3 80/67 6,500 0.67.59 5,000 0.70.85 3,000 0.74.09,400 0.76.3 9,00 0.8.30 75/63 5,000 0.7.58,600 0.74.87 0,700 0.76.08 9,00 0.8.30 7,00 0.85.9 75/57 3,00.00.56,600.00.84 0,500.00.05 8,800.00.7 6,900.00.5 85/7 33,700 0.6.97 3,900 0.64.30 30,500 0.67.56 8,00 0.70.84 5,900 0.73.8 80/67 3,00 0.68.96 9,900 0.7.7 8,000 0.75.55 5,700 0.79.8,500 0.84.79 75/63 30,00 0.7.95 7,400 0.76.8 5,00 0.79.53,600 0.84.79 9,900 0.88.77 75/57 7,900.00.9 6,00.00.5 4,900.00.50,500.00.76 0,000.00.73 85/7 4,800 0.6.39 39,400 0.63.8 37,500 0.65 3.5 35,700 0.68 3.50 33,00 0.70 3.49 80/67 39,400 0.68.37 37,500 0.7.80 34,600 0.74 3.4 3,000 0.76 3.47 9,500 0.80 3.43 75/63 37,00 0.7.36 33,900 0.75.79 3,500 0.77 3. 9,400 0.8 3.45 6,00 0.86 3.4 75/57 34,300.00.3 3,300.00.75 30,800.00 3.08 8,900.00 3.40 6,00.00 3.36 85/7 46,300 0.64.69 44,600 0.66 3. 43,00 0.68 3.64 40,600 0.70 4.06 37,800 0.7 4.0 80/67 44,000 0.7.68 43,00 0.74 3.8 40,000 0.76 3.63 38,000 0.78 3.98 34,000 0.8 4.03 75/63 4,00 0.74.67 39,00 0.77 3.7 36,900 0.79 3.56 33,800 0.83 3.96 30,600 0.87 3.98 75/57 38,300.00.63 38,800.00 3.5 35,600.00 3.56 33,00.00 3.94 30,400.00 3.95 85/7 54,400 0.65 3.0 5,00 0.66 3.7 50,00 0.67 4.9 47,00 0.69 4.66 43,500 0.7 4.7 80/67 5,900 0.7 3.08 49,500 0.73 3.64 46,000 0.76 4.8 43,500 0.78 4.55 38,400 0.80 4.65 75/63 49,900 0.73 3.06 45,600 0.76 3.64 4,300 0.78 4.09 38,700 0.8 4.55 34,300 0.85 4.60 75/57 45,00.00 3.0 4,800.00 3.63 40,900.00 4.0 37,900.00 4.53 34,00.00 4.56 85/7 68,500 0.60 3.87 64,500 0.6 4.6 6,300 0.63 5.7 57,500 0.65 5.76 5,300 0.66 5.75 80/67 64,800 0.66 3.83 60,800 0.68 4.49 56,000 0.70 5.09 53,000 0.7 5.6 45,300 0.77 5.6 75/63 60,900 0.69 3.8 54,500 0.7 4.50 49,600 0.75 5.03 45800 0.78 5.56 40,500 0.8 5.5 75/57 56,400.00 3.75 5,700.00 4.45 49,800.00 4.99 45,500.00 5.53 40,300.00 5.50 HEATING RATINGS Model Outdoor Temp - DB/WB ºF 0/0 7/5 35/33 47/43 6/56 Btuh kw Btuh kw Btuh kw Btuh kw Btuh kw 3HPP4A 0,00.7 3,000.73 5,400.7,600.80 6,00.87 3HPP30A 0,700.03 6,000.04,00.4 7,000.6 3,700.33 3HPP36A RHP3A36 5,900.53 0,00.58 4,900.66 33,600.8 40,00.93 3HPP4A 9,600.9,400.99 6,600 3.0 39,000 3.36 46,800 3.48 3HPP48A RHP3A48 3HPP60A RHP3A60 3,900 3.57 6,800 3.74 9,300 3.73 44,000 3.9 5,900 4.08 5,00 4.30 34,000 4.34 4,00 4.3 54,000 4.78 64,800 5.03 3HPP-RHP3 - to 5 Ton Packaged Heat Pumps / Page 8

BLOWER DATA 3HPP4A BLOWER PERFORMANCE Horizontal Airflow Air Volume at Specific Blower Taps (cfm) External Static Pressure in. w.g. Tap (Fan Only) Tap (Low Static) Tap 3 (High Static) Tap 4 (Low Static Tap 5 (High Static 0.0 640 830 950 900 060 0.30 460 800 90 870 030 0.40 370 760 880 830 980 0.50 - - - 70 840 800 960 0.60 - - - 640 800 730 930 0.70 - - - 600 750 690 90 0.80 - - - 570 700 640 860 NOTE - All air data measured external to unit with dry coil and less filter. For downflow air volume, add 0.0 in. w.g. to duct static. Taps 4 and 5 are used with Optional Electric Heat. Refer to Electric Heat nameplate for proper heat tap selection 3HPP30A BLOWER PERFORMANCE Horizontal Airflow Air Volume at Specific Blower Taps (cfm) External Static Pressure in. w.g. Tap (Fan Only) Tap (Low Static) Tap 3 (High Static) Tap 4 (Low Static Tap 5 (High Static 0.0 650 030 50 0 50 0.30 550 000 0 070 0 0.40 490 970 080 040 080 0.50 430 930 050 000 050 0.60 - - - 900 00 970 00 0.70 - - - 860 980 950 980 0.80 - - - 80 960 90 960 NOTE - All air data measured external to unit with dry coil and less filter. For downflow air volume, add 0.0 in. w.g. to duct static. Taps 4 and 5 are used with Optional Electric Heat. Refer to Electric Heat nameplate for proper heat tap selection. 3HPP36A AND RHP3A36 BLOWER PERFORMANCE Horizontal Airflow Air Volume at Specific Blower Taps (cfm) External Static Pressure in. w.g. Tap (Fan Only) Tap (Low Static) Tap 3 (High Static) Tap 4 (Low Static Tap 5 (High Static 0.0 650 40 30 40 30 0.30 590 00 60 00 60 0.40 500 50 30 50 30 0.50 430 00 00 00 00 0.60 - - - 060 60 060 60 0.70 - - - 00 0 00 0 0.80 - - - 980 080 980 080 NOTE - All air data measured external to unit with dry coil and less filter. For downflow air volume, add 0.0 in. w.g. to duct static. Taps 4 and 5 are used with Optional Electric Heat. Refer to Electric Heat nameplate for proper heat tap selection. 3HPP-RHP3 - to 5 Ton Packaged Heat Pumps / Page 9

BLOWER DATA 3HPP4A BLOWER PERFORMANCE Horizontal Airflow Air Volume at Specific Blower Taps (cfm) External Static Pressure in. w.g. Tap (Fan Only) Tap (Low Static) Tap 3 (High Static) Tap 4 (Low Static Tap 5 (High Static 0.0 780 450 650 50 650 0.30 690 370 570 430 570 0.40 60 80 50 380 50 0.50 540 00 440 90 440 0.60 - - - 0 360 0 360 0.70 - - - 060 60 50 60 0.80 - - - 990 60 090 60 NOTE - All air data measured external to unit with dry coil and less filter. For downflow air volume, add 0.0 in. w.g. to duct static. Taps 4 and 5 are used with Optional Electric Heat. Refer to Electric Heat nameplate for proper heat tap selection. 3HPP48A AND RHP3A48 BLOWER PERFORMANCE Horizontal Airflow Air Volume at Specific Blower Taps (cfm) External Static Pressure in. w.g. Tap (Fan Only) Tap (Low Static) Tap 3 (High Static) Tap 4 (Low Static Tap 5 (High Static 0.0 860 650 800 650 800 0.30 760 600 750 600 750 0.40 690 550 690 550 690 0.50 640 500 630 500 630 0.60 - - - 440 570 440 570 0.70 - - - 370 470 370 470 0.80 - - - 90 330 90 330 NOTE - All air data measured external to unit with dry coil and less filter. For downflow air volume, add 0.0 in. w.g. to duct static. Taps 4 and 5 are used with Optional Electric Heat. Refer to Electric Heat nameplate for proper heat tap selection. 3HPP60A AND RHP3A60 BLOWER PERFORMANCE Horizontal Airflow Air Volume at Specific Blower Taps (cfm) External Static Pressure in. w.g. Tap (Fan Only) Tap (Low Static) Tap 3 (High Static) Tap 4 (Low Static Tap 5 (High Static 0.0 000 80 950 80 950 0.30 900 790 90 790 90 0.40 800 730 860 730 860 0.50 750 670 800 670 800 0.60 - - - 630 700 630 700 0.70 - - - 530 560 530 560 0.80 - - - 380 360 380 360 NOTE - All air data measured external to unit with dry coil and less filter. For downflow air volume, add 0.0 in. w.g. to duct static. Taps 4 and 5 are used with Optional Electric Heat. Refer to Electric Heat nameplate for proper heat tap selection. 3HPP-RHP3 - to 5 Ton Packaged Heat Pumps / Page 0

DIMENSIONS - INCHES (MM) R 3-/ (89) E Supply Return (RHP3A 48 and 60 Models Only) Return Q G -/ (38) A F J Return D F Supply F H B F BACK VIEW 5-/ (40) -5/8 (6) G K TOP VIEW (5) 4 (0) Coil Access Panel L Condensate Drain 3/4 NPT C LEFT SIDE M N P Power Supply -/8 (9) Low Voltage Entry 7/8 () Electric Heat Power Entry RIGHT SIDE Blower Access Panel Rigging Holes (8) Model No. 3HPP4A 3HPP30A 3HPP36A RHP3A36 3HPP4A 3HPP48A 3HPP60A RHP3A48 RHP3A60 A B C D E F G H in mm in mm in mm in mm in mm in mm in mm in mm 3-/ 86 46-/ 8 46-/ 8 45-5/8 59 45-5/8 59 7-/ 445 -/ 9 4 0 34-/ 876 55-/ 40 50-/ 83 54-5/8 387 49-5/8 60 -/ 546 305 6-/4 59 Model No. 3HPP4A 3HPP30A 3HPP36A RHP3A36 3HPP4A 3HPP48A 3HPP60A RHP3A48 RHP3A60 J K L M N P Q R in mm in mm in mm in mm in mm in mm in mm in mm 4 0-3/4 44 5-5/8 397 7-3/4 705 4-7/8 63 9-3/4 48 - - - - - - - - - - - - 5-5/8 43-3/8 60 7-/8 435 9-3/4 756 6-7/8 683 5-/ 394 305 -/ 546 3HPP-RHP3 - to 5 Ton Packaged Heat Pumps / Page

ACCESSORIES DIMENSIONS - INCHES (MM) ECONOMIZER DAMPERS - DOWNFLOW FOR 4, 30 AND 36 MODELS FOR 4, 48 AND 60 MODELS 0 (54) 8 (457) 4 (60) Fresh Air Hood with Filter 8-/4 (78) 6-5/8 (4) -3/4 (34) ECONOMIZER DAMPERS - HORIZONTAL Barometric Relief Damper (Underneath) Fresh Air Hood with Filter 9 (483) 9 (483) Barometric Relief Damper (Underneath) NOTE - Downflow economizer is not available for 48 and 60 single-phase models. 9-/ (4) -/4 (565) 6 (660) A Model No. A B in mm in mm 4, 30, 36 7-5/8 448 -/ 9 4, 48, 60-3/4 55 -/4 3 4 (60) (305) 6 (660) B Economizer Adapter (Shipped attached to economizer) FRESH AIR DAMPERS MANUAL MOTORIZED Perforated Air Intake Panel (Replaces existing duct cover on 4-48-60 models) 3-3/4 (349) Air Intake Hood Air Intake Hood 3-3/4 (349) 5 (7) Adjustable Air Slide Damper Motorized Damper Assembly Adjustable Air Slide Damper 5 (7) Perforated Air Intake Panel (Replaces existing duct cover on 4-48-60 models) 3HPP-RHP3 - to 5 Ton Packaged Heat Pumps / Page

ACCESSORIES DIMENSIONS - INCHES (MM) ROOF CURB F D C 0-/ (67) E (5) -/ (38) A 4 (356) B Model No. 3HPP4A 3HPP30A 3HPP36A RHP3A36 3HPP4A 3HPP48A 3HPP60A RHP3A48 RHP3A60 A B C D E F in mm in mm in mm in mm in mm in mm 40 06 40 06 7-/ 445 0 508 8 457 -/ 546 44-/8 49 45 8 457 3-/ 597 3-/ 597 3 584 3HPP-RHP3 - to 5 Ton Packaged Heat Pumps / Page 3

REVISIONS Sections Accessories Dimensions Description of Change Revised C dimension for roof curb. Visit us at www.lennox.com For the latest technical information, www.lennoxcommercial.com Contact us at -800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 04 Lennox Industries, Inc.