FDOOT221, FDO221, FDT221

Similar documents
FDOOT241-9, FDOOT241-A, FDO241, FDT241

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

OH720, OP720, HI720, HI722

FDOOT241-A9-Ex Multisensor fire detector

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

Interbases. Sinteso FDSB221, FDSB228, FDSB229

Input module, input/output module

OOH740-A9-Ex Multisensor fire detector

Input module, input/output modules

Multi line separator module

OOH740-A9-Ex Multi-sensor fire detector

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

OOH740, OOHC740 Automatic fire detectors

Output module (230 V)

Mimic display driver, LED ribbon cable

ASA linear smoke detector

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

DM1131 / DM1133 / DM1134 Manual call points

OH110, OP110, HI110 Automatic fire detectors

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

DT1101A / DT1102A / DO110xA Automatic fire detectors

Radio fire detection system

FDBZ290 Air sampling smoke detection kit

FDBZ290 Air sampling smoke detection kit

SWING radio fire detection system

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

FDCIO223 (ES 45) Transponder

FC2040. Fire control panel. Sinteso. FS20 series, MP6

FDCL221-M Multi line separator module

Fire control panel for modernization

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

Fire control panels FC360

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

FDCL221-Ex Line adapter (Ex)

FDOOT221, FDOOT241-A3, FDOOT241-A4, FDOOT241-8, FDOOT241-9, FDOOT241-A9, FDO241, FDO221, FDT241, FDT221 Automatic fire detectors Technical Manual

FC2020 Fire control panel

Fire control panels FC726 FC726-XA

DF1101-Ex Infrared flame detector

OH110, OP110, HI110. Automatic Fire Detectors. Automatic Fire Detector For collective and conventional detector lines

Test units and accessories

DF1151-Ex Infrared flame detector

FDBZ290 Air sampling smoke detection kit Technical Manual

FD20 Sinteso Detector system

FDOOT241-A9-Ex Automatic fire detector Technical Manual

Room thermostat with 24-hour time switch and large LCD

DC1192 Input /Output module

Test units and accessories

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

FC724 Fire control panel

FT2080 Fire terminal (Touch) Mounting Installation

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Desigo Fire Safety intelligent detectors for complete safety

Frost Protection Thermostat

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

FT2080 Fire terminal (Touch) Mounting Installation

FC723 Fire control panel

FDCW241 Radio gateway Mounting

DOW1171 / DCW1151 Radio fire detection system

OH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual

Electronic timeswitch

FDL241-9 Linear smoke detector Mounting Commissioning

FC724 Fire control panel

FC722 Fire control panel

FC722 Fire control panel

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

FDA241, FDA221 Siemens ASD

Test units and accessories

Call stations and extensions

FDA241, FDA221 Siemens ASD

FDM273 Radio manual call point Mounting

Synova TM product catalog.

For internal use only. Distribution (please mark): Product Solution Multi-channel x

Sinteso TM product catalog.

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

1592P01. for liquids in piping DN

XC10 combined fire detection and extinguishing control

FS20 Fire detection system

Flush-mounted room thermostat

Room Temperature Controllers

Duct Temperature Sensors

FDS229 Alarm sounder with supplementary optical indication Technical Manual

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

FP120-Z1 Power supply kit A (70 W) Technical Manual

Fire & Security Products. Siemens Building Technologies Group

XC10 combined fire detection and extinguishing control

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

RVL479. Heating Controller. for use with a partner unit

FDCL221 Line separator

Fire protection for rolling stock. Innovative solutions from Siemens Building Technologies. Answers for infrastructure and cities.

FDCI221, FDCIO221 Input module, input/output module Technical Manual

Semi flush-mount room thermostats

FDM221, FDM223, FDM224, FDM223H, FDM224H Manual call points

XC10 Extinguishing control panels

Room Temperature Sensors

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Room Temperature Controller

Transcription:

Sinteso C-LINE FDOOT221, FDO221, FDT221 Automatic fire detectors For the automatically addressed detector bus FDnet The ideal fire detector for every application Signal processing with detection algorithms (DA) Early and reliable detection when fires occur Highly developed immunity to deceptive phenomena 2018-06-15 Control Products and Systems

Properties Features Resistant to environmental and interfering influences such as dust, fibers, insects, moisture, extreme temperatures, electromagnetic interference, corrosive vapors, vibration, artificial aerosols, and atypical fire phenomena Shock resistant, theft protection as an accessory Signal processing with detection algorithms Proven immunity to faults in power electronics Protected electronics, high-quality components Sophisticated sensors and electronic monitoring Internal alarm indicator (IAI), 360 visibility, alignment not necessary Integrated line separator The same detector base can be used for every type of detector 'One-man' testing, commissioning, diagnostics, and maintenance Exchange the detector without resetting the parameters Exchange the detector without a ladder at heights up to 8 m Ecological benefits: Environmentally friendly processing Reusable materials Electronic parts and synthetic materials can be easily separated Multi-sensor smoke detector FDOOT221 Multi-sensor smoke detector consisting of: Point detector with additional heat sensors Detector dust cap to protect the point detector during the construction phase Function Functions according to the scattered light principle with two sensors: Optical forward and backward scattering Opto-electronic measuring chamber: Obstructs disruptive extraneous light but can be relied upon to detect both light and dark smoke particles Two additional heat sensors increase the fire detector's immunity to deceptive phenomena. Selectable detection behavior thanks to different parameter sets For early detection of flaming fires of solid and liquid substances as well as of smoldering fires For early and reliable fire detection in an environment with deceptive phenomena Can be used addressed 2

Smoke detector FDO221 Smoke detector consisting of: Point detector Detector dust cap to protect the point detector during the construction phase Function Functions according to the scattered light principle with one sensor: Optical forward scattering Opto-electronic measuring chamber: Obstructs disruptive extraneous light but can be relied upon to detect both light and dark smoke particles Selectable detection behavior thanks to different parameter sets For early detection of flaming fires as well as smoldering fires Can be used addressed Heat detector FDT221 Heat detector consisting of: Point detector Detector dust cap to protect the point detector during the construction phase Function Two redundant heat sensors: If one of the two sensors fails, the fire detector still conforms to the highest response class Measures the operating temperature and the temperature inside the detector housing so that temperature rise can be detected. Selectable detection behavior thanks to different parameter sets For monitoring rooms in which rapid temperature rise is to be expected in the event of a fire or if optical detection is difficult Can be used addressed Dummy detector FDX291 To cover bases that are left empty for prolonged periods of time 3

Type Overview Type Designation Order no. Weight [kg] Point detector FDOOT221 Multi-sensor smoke detector A5Q00001566 0.105 FDO221 Smoke detector A5Q00001565 0.104 FDT221 Heat detector A5Q00001567 0.086 Accessories FDX291 Dummy detector S54319-F2-A1 0.120 You will find information about detector bases and accessories in document 007775. Product documentation Document ID Title 007004 Technical manual Automatic fire detectors FDOOT221, FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-8, FDOOT241-9, FDOOT241-A9, FDO241, FDO221, FDT241, FDT221 007775 Data Sheet Detector bases and accessories FDB22x, FDB20x, FDB241, FDB251, FDB281, FDB299 008164 Equipment overview Sinteso Detector system FD20 008331 List of compatibility (for 'Sinteso ' product line) 009409 Data sheet Colored detectors, bases and base attachment FDO.., FDOOT, FDT, FDB Related documents such as environmental declarations, CE declarations, etc., can be downloaded at the following Internet address: https://siemens.com/bt/download 4

Installation Easy, time-saving, and top quality mounting Detector base FDB221 for surface-mounted and recess-mounted supply lines Detector base FDB222 for flush mounting, only for recess-mounted supply lines Extra-long mounting slits allow existing drill holes from other systems to be reused A large opening in the detector base makes it easy to feed the cables through. Screwless connection terminals (spring clip principle) Detector line can be connected without any tools The wire can be inserted easily by hand The detector can be mounted in the base easily by hand or using a detector exchanger The alarm indicator (AI) is centered in the detector, which makes alignment of the detector superfluous 1 2 3 5 4 1 Mounting slits 4 Alarm indicator 2 Screwless connection terminals 5 Opening for cable entry 3 Detector base You will find more information about detector bases and accessories in document 007775. Disposal The device is considered an electronic device for disposal in accordance with the European Guidelines and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. 5

Technical data Operating voltage (modulated) FDOOT221 FDO221 FDT221 DC 12 33 V Operating current (quiescent) 190 230 A 180 230 A 130 200 A External alarm indicators which can be connected Without sounder base With sounder base Communication protocol System compatibility 2 1 FDnet FS20, AlgoRex, SIGMASYS Operating temperature -10 +60 C -10 +60 C Depending on the parameter settings: -10 +50 C -10 +70 C Storage temperature Air humidity (short-term moisture condensation permitted) Color Protection category (IEC 60529) With detector base FDB221/- AA, FDB222, FDB291 Base FDB221 and sealing element FDBZ295 Base attachment humid FDB293 and base attachment wet FDB295 Standards CEA 4021 EN 54-7 EN 54-17 Approvals: VdS LPCB FM DNV GL (Marine) G204006 126bg/01 3029351 MEDB00003UK -30 +75 C 95 % rel. ~RAL 9010 pure white IP43 IP44 IP44 EN 54-7 EN 54-17 G204018 126bf/01 3029351 MEDB00003UK EN 54-5 EN 54-17 G204020 126bj/01 3046115 MEDB00003UR Permissible wind speed Max. 5 m/s Max. 5 m/s - 6

07 07 07 0786 FDOOT221 Siemens Schweiz AG; Theilerstrasse 1a CH-6300 Zug Technical data: see doc. 007004 FDOOT221 - Point type smoke detector incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-7 / EN 54-17 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or https://siemens.com/bt/download DoP No.: 0786-CPR-20006; DoC No.: CED-FDOOT221 0786 FDO221 Siemens Schweiz AG; Theilerstrasse 1a CH-6300 Zug Technical data: see doc. 007004 FDO221 - Point type smoke detector incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-7 / EN 54-17 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or https://siemens.com/bt/download DoP No.: 0786-CPR-20001; DoC No.: CED-FDO221 0786 FDT221 Siemens Schweiz AG; Theilerstrasse 1a CH-6300 Zug Technical data: see doc. 007004 FDT221 - Point type heat detector incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-5 / EN 54-17 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or https://siemens.com/bt/download DoP No.: 0786-CPR-20003; DoC No.: CED-FDT221 Dimensional drawing 100 100 54.6 45.7 45.7 With base FDB221 for surface-mounted cable entry With base FDB222 for flush mounting 7

Issued by Siemens Switzerland Ltd Division International Headquarters Theilerstrasse 1a CH-6300 Zug Tel. +41 58 724 2424 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2014 Technical specifications and availability subject to change without notice. 8 Document ID Manual FD20 Edition 2018-06-15 Register 2