M113S Users Manual. MERLIN STEALTH M113S Electric Fence Energizer GROUP OF COMPANIES. PDF created with pdffactory trial version

Similar documents
GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer. Users Manual

SPECTRA 1727 USER S GUIDE

636 and 646 Keypads. User s Manual

Protégé Eclipse LED Keypad User Manual PRT-KLES

Digiplex LED Keypads. User s Manual

The Icon Series. User Guide. CDV25 Version 1.0. Iconopm1.pm

LCD and 16-Zone LED Keypads. User s Manual

CD6102 / CD6102 OC / CD6102-2

10-Zone Spectra LED Keypads

642 LCD Keypad. User Manual

Introduction... 1 System Overview... 1 System Diagram... 2

Version 1.03 January-2002 USER S MANUAL

EasyLoader. End User Manual

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.

INSTRUCTION MANUAL PC255O

INSTRUCTION MANUAL PC255O

INSTALLATION MANUAL PC56O. Version 1.OA

KFP-CF Series Operation Manual

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function

VX SERIES Wireless Thermostat with Occupancy Sensor

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Digiplex LED Keypads User s Manual

Automatic Phone-Out Home Monitoring Systems

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

The Vanguard System TM VM-2900 Air Seeder Monitor. Operator s Manual

BACKUP BATTERY INSTALLATION INSTRUCTIONS

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

ion Genesis Pump Controller

JA-63 Profi User manual

2-Port alarmcharge Hub - Manual

AXI LED USER MANUAL (REV. 1.0)

Security Alarm System Owner's Guide 8 sector CDS Dialler 8-24 sector Control Dialler 8-24 sector Control Securitel Version 1.0 lcopm.

L900 series USER MANUAL

KP600F/L LED/LCD KEYPADS. Owner's Manual. Use with AV6500 & SP850 Control panels

Watchguard WGAP864 User Manual

640 Series Advanced Remote Vehicle Security System

User s Information Guide R2A

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

External Wireless Sounder

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

G34 AU1B (External Ultrasonic Sensor) Version 3

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

ZM1 User Manual JVA TECHNOLOGIES.

Auto Dialer. Manual E-921APQ E-921GPQ

Washable HEPA Air Cleaner with PlasmaWave Technology

Solution 880 Operators Manual. Issue 1.00

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

PRO-TEC SYSTEM ONE. Trailer Security Systems Model # PTS-2. Photo includes PTS-2 with optional pager unit

Contents. Glossary

Installation, Operation & Service Manual

PowerWave-16. Users Operating and Programming Guide Version P/N Rev. B N.A July 2002

IDS816 User Manual H Issued January 2009

For Quick Set-Up go to Page 14

ZLM4 OEM Technical Manual

External Wireless Sounder

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

Wireless Keypad GKP-S8M

HILLS Series LED Code Pad User Manual

- User Brochure Programmable Thermostat 510

Using Your GEM-P400 Security System H

SCORPION Z16040C, Z8040C and Z5120C

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

INSTRUCTION MANUAL P Heating and 1 Cooling

Premier Hazard STC Instructions

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

FW-RA-LED Remote Multiplex Annunciator Panels

DTS SECURITY P.O.BOX 3399 Base plate-mounting EDENVALE instructions 1610 TELEPHONE

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

NESS 5000 SERIES DIALLER

RR-PM1200 OPERATING AND PROGRAMMING GUIDE

6502B RF Distribution

Wireless Keypads LKP(E)S8M Series

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Introduction... 1 System Overview... 1 System Diagram... 2

Instruction Manual US PAT: 6,824,069 6,786,421. Models: CT03TS21 CTO3TS32 CTO3TS32H

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

Using Your. Security System With LED Keypad S5030, S5031, S5032

User s Manual For Model Aero-551 (Rev. Orig.)

Solution Ultima Series Operators Manual ISSUE 1.00

Model 3901T / 3902T / 3903T

Protégé EliteSuite Eclipse LED Keypad Installation Manual ELT-KLES

5000 SERIES 8 ZONE INSTRUCTION MANUAL

Paradox Security System Graphic Dept - PRINTED IN CANADA. keypad entries in memory. arming permits movement in pre-selected,

Intruder alarm system Operating Instructions

Model: M30. Owner s Operation Manual. For correct operation, please read this manual to familiarise yourself with the features.

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

IMPORTANT SAFETY INFORMATION:

Remote Vehicle Control System. Security and Convenience System

ZM20 OEM Technical Manual

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

- User Brochure tekmarnet 4 Setpoint Control 161

INSTALLATION & OPERATION MANUAL

32-Zone Wireless Transceiver Control Panel MG5000. User s Guide

Owner s Manual. PIR-1 IR Learner

Transcription:

GROUP OF COMPANIES MERLIN STEALTH M113S Electric Fence Energizer M113S Users Manual Revision 1.0 Date: 29 January 2007

Table of Contents FOREWORD.... 3 GUARANTEE.... 4 INTRODUCTION.. 5 OPERATION WITHOUT A KEYPAD. 5 OPERATION WITH A KEYPAD.. 5 USING YOUR KEYPAD KEYPAD.. 6-10 FENCE INDICATOR LIGHTS 11 WHAT THE ENERGIZER LIGHTS INDICATE 12 WHAT THE KEYPAD LIGHTS INDICATE 13 DOCUMENT REVISION HISTORY. 14 No user serviceable parts inside the energizer. 2

Foreword FOREWORD The Merlin Range of energizers has evolved over the past fifteen years. The energizers are designed to comply with the latest international specifications. In order to offer some product flexibility the embedded software in the energizers may change. The latest version of documentation and energizer features can be viewed on our website at: www.nemtek.com The M113S Energizer has patented energy control and safety features. Refer any questions and special requirements to suitably trained installers. Electric fencing can be lethal. Avoid head contact with the fence. Get the installer to explain the options of current limiting resistors, the enhanced safety features of the M113S and the low-voltage operation of the energizer. 3

Guarantee G U A R A N T E E The Merlin energizer, manufactured by IO Tech Manufacturing (Pty) Ltd, is guaranteed for a period of one year from date of sale against defects due to faulty workmanship or materials. IO Tech Manufacturing (Pty) Ltd will, at its discretion, either repair or replace a product that proves to be defective. IO Tech Manufacturing (Pty) Ltd guarantees that the product, when properly installed and used in line with the specification as determined by IO Tech Manufacturing (Pty) Ltd from time to time, will execute its function of generating a suitable potential. IO Tech Manufacturing (Pty) Ltd does not guarantee that the operation of the product will be uninterrupted and totally error free. Faulty units must be returned to Nemtek, Units 4 & 5, 64 Vervoer Street, Kya Sand, Randburg, Gauteng, South Africa OR Nemtek Security Warehouse, Unit 4, Meadowdale Park, Cnr. Herman & Dick Kemp Roads, Meadowdale, Edenvale, Gauteng, South Africa. The buyer shall pay all shipping and other charges for the return of the product to Nemtek or Nemtek Security Warehouse. L I M I T A T I O N O F G U A R A N T E E The guarantee does NOT apply to defects resulting from acts of GOD, modifications made by the buyer or any third party, misuse, neglect, abuse, accident and mishandling. E X C L U S I V E R E M E D I E S The remedies provided herein are IO Tech Manufacturing (Pty) Ltd s sole liability and the buyer s sole and exclusive remedies for breach of guarantee. IO Tech Manufacturing (Pty) Ltd shall not be liable for any special, incidental, consequential, direct or indirect damages, whether based on contact, tort, or any other legal theory. The foregoing guarantee is in lieu of any and all other guarantees, whether expressed, implied, or statutory, including but not limited to warranties of merchantability and suitability for a particular purpose. 4

Introduction INTRODUCTION The energizer should ideally be operated by means of a remote keypad. This enables the user to have access to many energizer features and offers the greatest security. It can, however, be operated by means of a Nemtek tab or a remote on/off switch. OPERATION WITHOUT A KEYPAD Turning the energizer On/Off: Unless the feature has been disabled by the installer, the energizer can be turned On or Off by holding the Nemtek plastic tab over the corresponding logo on the fascia of the unit. Remove the tab on noticing the energizer turning On or Off. After an alarm occurs: Switch the unit off with the Nemtek tab or remote key-switch. This will silence the siren ( if it has not already timed-out), internal beeper and will switch the strobe off. One of the alarm lights will be flashing or remain lit to indicate the source of the alarm. A permanently lit indicator notifies the user that the fault no longer exist. In the latter case simply turning the energizer On again will clear the memory condition. A flashing alarm light illustrates that the fault condition persist. In this case rectify the condition which caused the alarm. To reset and clear the memory condition turn the energizer On and Off and On again. Only if the alarm condition is resolved will the energizer operate without alarm activation. OPERATION WITH A KEYPAD The energizer may be operated via a remote keypad. In this case the Nemtek tab becomes optional. ( Installer programmable). In order to provide different access levels to the energizer and its functions different types of user are defined. A master user has full control of the energizer and may bypass different alarm functions. The master user may change the pin identification number for all the users. There is only one master user with a default PIN of 1234, user #0. There are three normal users and three reset users. A normal user may turn the energizer On/Off and reset alarm conditions but not change the functionality of the energizer. User #1,#2 and #3. For 5

Using your KEYPAD security reasons they have no default codes and must be assigned by the master user. A reset user may only reset the alarms but not change the On/Off state of the energizer. User #4,#5,#6. For security reasons they have no default codes and must be assigned by the master user. The embedded Linux platform will be made commercially available during 2007 that will provide connectivity to the energizer and a history of all events including user intervention. The three different users in the normal operators allows for three eight hour shifts to be monitored. The energizer will restore its condition to its previous state should there be a total power failure i.e. mains failure and battery flat. Note that the Gate inputs are active even when the energizer is switched off. Use the Gate Bypass function if these inputs are to be ignored. USING YOUR KEYPAD SWITCH THE FENCE ON / OFF (Master/Normal User) To switch the fence On or Off, enter your four digit PIN followed by the # key. If the red ON light is lit or flashing, the fence is energized. Don t pause for more than 5 seconds while entering the digits, or the control panel will reject your PIN number. If you make a mistake while entering your PIN, press the # key and start again. An incorrect PIN will cause the control panel to beep 5 times. The default master (User # 0) PIN is 1 2 3 4. AFTER AN ALARM OCCURS Enter your PIN (all users) and press the # key. This will silence the buzzer and siren. It will switch the fence off. One of the ALARM lights will flash or stay lit to indicate the source of the alarm. A flashing indicator illustrates that the fault condition persists. A permanently lit 6

Using your KEYPAD indicator notifies the user that the fault no longer exists. In the latter case simply turning the energizer on again will clear the memory condition. If the flashing alarm condition cannot be resolved, the alarm will be activated irrespective of the number of times the unit is turned On or Off. The Master user can bypass alarm conditions. A reset user will only reset the alarm outputs and not change the On/Off state of the energizer. CHANGE THE VOLTAGE ON THE FENCE Enter your PIN (master only) and press the * key, enter the digit 3, then press the # key. When the fence is on and in low voltage mode, the red ON light will flash. The red ON light will stay permanently lit if the fence is in high voltage mode. Use the low voltage mode when children are in the fence vicinity. BYPASS THE FENCE ALARM Enter your PIN (master only) and press the * key, enter the digit 1, then press the # key. The FENCE ALARM light will start flashing slowly to confirm the fence alarm is bypassed. To cancel the bypass, repeat the same sequence of keys. BYPASS THE SIREN AND STROBE LIGHT (SILENT ALARM) Enter your PIN (master only) and press the * key, enter the digit 4, then press the # key. The beeper in the control panel will still be active. UN-BYPASS THE SIREN AND STROBE LIGHT Enter your PIN (master only) and press the * key, enter the digit 7, then press the # key. MAKE THE GATE ALARM IMMEDIATE(Both Gates) Enter your PIN (master only) and press the * key, enter the digit 2, followed by the digit 7, then press the # key. The GATE ALARM light will start flashing, with a cadence of one flash every 5 seconds, to confirm the gate alarm is immediate. 7

Using your KEYPAD MAKE THE GATE ALARM IMMEDIATE(Gate 1) Enter your PIN (master only) and press the * key, enter the digit 2, followed by the digit 7, followed by the digit 1, then press the # key. The GATE ALARM light will start flashing, with a cadence of one flash every 5 seconds, to confirm the gate alarm is immediate. MAKE THE GATE ALARM IMMEDIATE(Gate 2) Enter your PIN (master only) and press the * key, enter the digit 2, followed by the digit 7, followed by the digit 2, then press the # key. The GATE ALARM light will start flashing, with a cadence of one flash every 5 seconds, to confirm the gate alarm is immediate. MAKE THE GATE ALARM DELAYED(Both Gates) Enter your PIN (master only) and press the * key, enter the digit 2, followed by the digit 4, then press the # key. The default gate delay is 4 minutes. MAKE THE GATE ALARM DELAYED(Gate 1) Enter your PIN (master only) and press the * key, enter the digit 2, followed by the digit 4, followed by the digit 1, then press the # key. The default gate delay is 30 seconds. MAKE THE GATE ALARM DELAYED(Gate 2) Enter your PIN (master only) and press the * key, enter the digit 2, followed by the digit 4, followed by the digit 2, then press the # key. The default gate delay is 30 seconds. BYPASS THE GATE ALARM(Gate 1 and Gate 2) Enter your PIN (master only) and press the * key, enter the digit 2, then press the # key. The GATE ALARM light will start flashing slowly to confirm that the gate alarm is bypassed. To cancel the bypass, repeat the same sequence of keys. BYPASS THE GATE ALARM (Gate 1) Enter your PIN (master only) and press the * key, enter the digit 2, followed by the digit 1, then press the # key. To cancel the bypass, repeat the same sequence of keys. 8

Using your KEYPAD BYPASS THE GATE ALARM (Gate 2) Enter your PIN (master only) and press the * key, enter the digit 2, followed by the digit 2, then press the # key. To cancel the bypass, repeat the same sequence of keys. TURN THE GATE CHIME ON (Gate1) Enter your PIN (master only) and the * key, enter the digit 2, enter the digit 8, enter the digit 1, then press the # key. If the chime is on, the keypad will beep three times if the gate opens and twice if it closes. TURN THE GATE CHIME OFF (Gate1) Enter your PIN (master only) and the * key, enter the digit 2, enter the digit 8, enter the digit 2, then press the # key. No audible indication of gate opening or closing. TURN THE GATE CHIME ON (Gate2) Enter your PIN (master only) and the * key, enter the digit 2, enter the digit 8, enter the digit 3, then press the # key. If the chime is on, the keypad will beep three times if the gate opens and twice if it closes. TURN THE GATE CHIME OFF (Gate2) Enter your PIN (master only) and the * key, enter the digit 2, enter the digit 8, enter the digit 4, then press the # key. No audible indication of gate opening or closing. BYPASS THE SERVICE ALARM Enter your PIN (master only) and press the * key, enter the digit 9, then press the # key. The SERVICE ALARM light will start flashing slowly to confirm that the service alarm is bypassed. To cancel the bypass, repeat the same sequence of keys. The energizer will indicate a service alarm if the battery voltage is low. 9

Using your KEYPAD MANUAL BATTERY TEST Enter your PIN (master only) and press the * key, enter the digit 6, then press the # key. The keypad will beep four times indicating the battery test has started. This test disables the mains input for 20 minutes and monitors the battery voltage. If the battery voltage falls below an acceptable level during this test the battery service light will come on, provided the bypass is not enabled, and indicates the battery needs replacing. It is advisable to have the energizer running in High Voltage mode during this test. It is advisable to test battery condition at least twice a year. (If the auto battery test feature is enabled by the installer, the timing sequence will be re-initiated.) CHANGING A USER PIN Master PIN User (0-6) New PIN New PIN Enter your master PIN, press the * key, enter the digit 0, then press the # key. Enter the user number (0-6), and push the # key. User number 0 is the master PIN that has system configuration rights i.e. bypass of alarm conditions etc. Enter that user s new PIN and press the # key. Enter the new PIN again and press the # key. If the new PIN is accepted, the control panel will beep four times. If you make a mistake while programming, or if the system rejects the new PIN, the control panel will beep five times. ALTERING THE KEY-PAD INDICATOR BRIGHTNESS: The brightness of the keypads can be increased or decreased by pressing and holding the 1 or 7 keys respectively. The key-pad will beep while the indicator brightness is changing. No user PIN is required for this operation. 10

MERLIN S What the Energizer lights indicate Fence Indicator s FENCE INDICATOR LIGHTS The M113S energizer monitors the fence with every pulse. A finite amount of energy is used to excite the fence. Depending on the current magnitude of a fence pulse a second pulse may be used to excite the fence and effectively double the output energy. The occurrence of the second pulse is indicated by the illuminating of the HIGH POWER indicator. Under normal fence operating conditions the GOOD indicator should flash once a second. As the fence becomes loaded due to excessive vegetation or moisture the Check indicator may start flashing. If the loading becomes severe, the HIGH POWER indicator will also start flashing and possibly the ALARM indicator as well. When this occurs the voltage on the fence may change considerably because the available output energy has doubled. The fence indicator lights may cycle between ALARM / CHECK and GOOD as the effectiveness of the fence is maintained. Should the fence loading be such that the fence voltage is insufficient to be a deterrent then the ALARM indicator will remain lit or have a fast flash and the alarm outputs, if enabled, will activate. FENCE1 Fence voltage acceptable Fence voltage questionable. Inspect fence and do maintenance. If lit permanently the fence dropped below acceptable voltage levels. Flashing intermittently in conjunction with the HIGH POWER indicator indicates severe loading on the fence. HIGH POWER An indication that the output energy of the energizer is being doubled due to fence loading. Continuous operation of the HIGH POWER indicator is to be avoided. Either there is excessive vegetation or fault on the fence. The HIGH POWER indicator will only flash briefly if a short is presented to the energizer. The energizer would detect this as a potential head/body shock that can be lethal and reduce, or if installer configured stop, any further energy from exciting the fence. 11

What the Energizer lights indicate WHAT THE ENERGIZER LIGHTS INDICATE Condition: Power On Fence Good Fence Check Fence Alarm Gate (1 or 2) High Power Service Remarks FENCE GOOD ON ON OFF OFF OFF OFF OFF FENCE OFF ON OFF OFF OFF OFF OFF OFF OFF FENCE OFF ON OFF MAINS FAILURE LOW VOLTAGE MODE FENCE CHECK OFF FAST MAY Fence on, working properly Fence off, working properly Fence turned off with alarm condition active System on battery power Energizer switched to low voltage Check Fence Remove vegetation FENCE ALARM FENCE BYPASS GATE OPEN GATE BYPASS GATE IMMEDIATE SILENT ALARM GATE2 CONTROLS FENCE VOLTAGE FAST FAST 1 EVERY 5 SECONDS Gate2 LONG EVERY 5 SECONDS MAY 1 SHORT EVERY 5 SECONDS Problem on fence Fence alarm switched off Gate is open Gate alarm switched off Appropriate gate input is in immediate mode. Siren or strobe light not activated by alarm! Gate 2 closed: fence in lowvoltage mode Gate 2 open: fence in highvoltage mode BATTERY VOLTAGE LOW OFF No mains, Faulty fuse ALARM MEMORY (ON) (ON) (ON) Old alarm. Enter PIN # SERVICE ALARM BYPASS SERVICE ALARM FAST Service alarm switched off No mains, battery flat, faulty fuse 12

What the Keypad lights indicate WHAT THE KEYPAD LIGHTS INDICATE Condition: Power Good On Fence Gate (1 or 2) Service FENCE GOOD ON ON ON OFF OFF OFF FENCE OFF ON OFF OFF OFF OFF OFF FENCE OFF MAINS FAILURE LOW VOLTAGE MODE FENCE ALARM FENCE BYPASS GATE OPEN GATE BYPASS GATE IMMEDIATE SILENT ALARM GATE2 CONTROLS FENCE VOLTAGE ALARM MEMORY SERVICE ALARM BYPASS SERVICE ALARM ON OFF OFF OFF FAST FAST 1 EVERY 5 SECONDS Gate2 LONG EVERY 5 SECONDS 1 SHORT EVERY 5 SECONDS Remarks Fence on, working properly Fence off, working properly Fence turned off with alarm condition active System on battery power Energizer switched to low fence voltage Problem on fence Fence alarm switched off Gate is open Gate alarm switched off Appropriate gate input is in immediate mode. Siren or strobe light not activated by alarm! Gate 2 closed: fence in low-voltage mode Gate 2 open: fence in high-voltage mode (ON) (ON) (ON) Old alarm. Enter PIN # FAST No main, battery flat, faulty fuse 13

Document Revision History DOCUMENT REVISION HISTORY Revision 1.0 29 January 2007 End of document 14