Fire Prevention Systems

Similar documents
Technologies Fire Prevention Systems. Oxeo Prevent Oxygen Reduction System Active Fire Prevention using natural Nitrogen

How can you minimize consequential damages in case of a fire?

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

FoamFatale INTRODUCTION OF A NOVEL HIGH END TECHNOLOGY FOR LARGE ATMOSPHERIC STORAGE TANK FIRES. TFEX 1 Ltd.

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

Element C3.4 Fire Fighting Equipment

Safe, Effective, Environment-friendly

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

Oxeo extinguishing systems

Fire suppression systems for server rooms and data centres

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp)

automatic FiReFighTing SYSTeMS in PainT booths

FIRE SUPPRESSION SYSTEM

ODS & SGG Alternatives for the Fire Protection Industry 2018

Performance Based Fire Protection With Water Mist

creative thinking : powerful solutions The new True Energy Vaccine Refrigerator with Sure Chill technology

Safe Operation Manual. Honeywell IQ Force Gas Detector

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-75 VSD+ (7-75 kw/ hp)

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM

High flying fire protection HI-FOG for aircraft hangars

THE WORLD LEADER. in special hazard fire suppression solutions

Atlas Copco. Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp)

What is HI-FOG? The natural enemy of fire

Fire Prevention Plan Program

CO2 COCO GAS FLOODING SYSTEM

What extinguishes fires without pressure peaks?

STANDARDS FOR ACTIVE FIRE PROTECTION. Stewart Kidd Loss Prevention Consultancy Ltd

Ceasefire Watermist Hydrant Systems

AUTOMATIC FIREFIGHTING SYSTEMS IN HOSPITALS

Aspirating Smoke Detection (ASD) Systems Fire Detection

Protecting Critical Facilities Against Explosions

AUTOMATIC FIREFIGHTING SYSTEMS IN KITCHENS

Protecting Facilities Against Explosions. Since 1956

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

GAS EXTINGUISHING SYSTEM INERT GAS. Argotec with carbon dioxide. Safe for certain.

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS

How can I protect invaluable assets and the environment from the effects of a fire?

Carbon Dioxide Extinguishing Systems Fighting fire with CO2

Water Mist Fire Suppression

Deluge & Preac tion Systems

SECURITY BLANKET Foam Fire Protection Products

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

MRI Advanced Cooling System

Product Supply, Hire & Service. Complete Safety Solutions for the Oil, Gas, Marine & Energy Industries. Safer.Smarter.Tyco.

Section - III SYSTEMS DESCRIPTION

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK

Fire protection solutions for ships and offshore facilities

Climate Control System

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

TWO TIMES THE FIGHT Twin-Agent Fire Suppression Systems

Affordable fire suppression solutions

Fire Prevention Plan Program Prepared by: Allied Insurance Brokers, Inc.

PAFSS Fire Suppression Systems from Jactone. Automatic Fixed Fire Suppression Systems. JACTONE.COM/PAFSS +44 (0)

1998 Expedition/Navigator Workshop Manual

Explosion Venting and Suppression of Bucket Elevator Legs, G90-990

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI

FIRE MARSHAL REGULATIONS

DRY BULK HANDLING SYSTEM

This document is a preview generated by EVS

RIM SEAL SYSTEMS E-BOOK

Fire protection for emergency power supply

Fire Suppression Systems

Air to Water SPLIT TYPE & MONOBLOCK TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING. High Power model Comfort model Compact model

With CV Technology products and care, you ll be better protected from dust explosions.

Creating a safer world!

Sinorix Silent Extinguishing Technology protecting the quiet way

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

Guidance. Service of Hydrocarbon Refrigerant Equipment in a Retail Environment

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

Identify RISKS. Design SOLUTIONS. Prevent DISASTERS

Hazardous Material Safety Program

Amerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.

Fire protection for rolling stock. Innovative solutions from Siemens Building Technologies. Answers for infrastructure and cities.

Peerless Boilers. Series MI. Residential Gas Boilers

Fire Prevention Plan for McGrath Health and Wellness Center 1714 Cleneay Avenue

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems

INTERNATIONAL STANDARD

An Overview of Extinguishing Systems for Computer Equipment

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

Rust, corrosion and leakages threaten even the best network. Only Quality Air Solutions. in optimal shape. air distribution

The Importance of Flame Retardant. Jackson Liu, 3M Taiwan

Corrosion in Fire Sprinkler Systems Increasing Your Liability, Increasing Your Costs, and Shortening System Life

UniVario Industrial Fire Detectors Versatile in Application

XC10 combined fire detection and extinguishing control

A comprehensive systems-level approach in cabin design minimizes fire potential and helps ensure passenger safety. aero quarterly qtr_04 11

Inert Gas Fire Extinguishing System

Peerless Boilers. Peerless Pinnacle. High Efficiency Stainless Steel Boilers

CO 2 EXTINGUISHING SYSTEMS

designed for rail 5000 Series

PESIT-Bangalore South Campus

Active fire prevention OxyReduct

XC10 combined fire detection and extinguishing control

FireIce & FireIce Shield F.A.Q.

Powerful and reliable. Also for high ambient temperatures. weco Compact chillers

Transcription:

Fire Prevention Systems 01

A Revolution in Fire Safety FirePASS is a revolutionary fire prevention technology. It has the unique ability to create a breathable oxygen-reduced (hypoxic) environment which prevents flame ignition and, at the same time, is safe and healthy for human occupants. The FirePASS technology guarantees: Unmatched fire safety FirePASS prevents fire proactively instead of suppressing it after it has started and damage has already occurred. Absolute safety for human beings FirePASS produces and uses breathable air for fire pre - vention thus avoiding any hazard to human occupants and any damage to the prevented rooms and their content. Environmental friendliness FirePASS uses natural, ambient air as its resource no chemicals, no gases or similar are involved. The FirePASS agent is simply hypoxic (oxygen-reduced) air. Nothing is added. The revolutionary concept of FirePASS technology and its various applications are protected by patents worldwide. The FirePASS group is the only legal manufacturer and vendor of systems providing breathable fire-prevention environments. Why be reactive when you can be proactive?! 01

The FirePASS approach Configuration of FirePASS systems 1% Hypoxic air is produced by partly filtering out oxygen from am bient atmospheric air. A schematic view on the standard configuration of FirePASS hypoxic air venting systems: 78% 21% of oxygen. By ventilating a room with this oxy genreduced air a hypoxic fire preven- Fresh ambient air ) enriched air ) Permanent normal Atmosphere (at all altitudes) 84% 1% 15% tion en vironment is established. Typically, such a FirePASS prevention environment suitable for human life but is not sufficient to support combustion. The respective partial pressure of oxygen corresponds to COMPRESSION UNIT Machine room AIR SEPARATION UNIT CONTROL UNIT Air ) One or several protected areas OXYGEN MONITOR FirePass Prevention Environement Oxygen Nitrogen Other Safe working conditions Most common flammable solid materials and liquids cannot be However, humans easily tolerate an oxygen-reduced atmosphere as in natural, ambient air). Anybody traveling on a modern passenger airplane has experienced oxygen concentrations corresponding - Bolivia, without showing any impairment of their physiological functions. Scientific research has proven that working in such hypoxic conditions does not impose any health hazards on healthy human beings. How FirePASS works - Ambient air is drawn into the hypoxic generator where it is purified and turned hypoxic. - The air ventilates the entire room, inhibiting any common fire ignition. - Hypoxic air leaks from the room, thus completing the flow and ventilating the facility. - A control unit monitoring the room with oxygensensors permanently ensures a stable hypoxic environment in the room. FirePASS uses natural, ambient air as its agent to prevent fire 02 03

Custom Fit Technology Characteristics of FirePASS systems FirePASS offers a large variety of hypoxic air venting systems that can fit any application. They range from self contained units for smaller volumes to big systems for huge buildings. FirePASS systems can protect single or multiple rooms and compartments Two examples: Hypoxic Air Generator Unit FP-8000 Twin System FirePASS hypoxic air venting systems will be designed, engineered and manufactured to the requirements and specifications of our customers. FirePASS systems are guaranteed to offer the following features: - Every system is equipped with a touch panel control unit, which can be located remotely and is able to communicate with Building Management Systems. - O -room monitoring units are provided in the required number. - An inbuilt battery assures the function of the control and alarm system even in the case of general power failure. - The compression units are equipped with highly reliable compressors, refrigerant dryers, separate condensate cleaners and buffer vessels. - Each hypoxic air generator unit has a 3-stage pre-filtering and a moisture alarm. - 3-phase 400v and 50Hz power supply (other voltages and frequencies on request). - Every system is fully mounted and tested. - The layout and skid size of the system may be adjusted to specific requirements and size of the particular location. - All systems can be configured as Twin-Systems, offering full redundancy of compression and generator units to improve failure safety. 04 05

ters etc. Any damage to equipment or interruption of operation immediately causes huge costs and incidental damages. FirePASS systems completely eliminate any risk of data losses and system down times caused by fire. Typical Applications FirePASS achieves the ultimate goal in FirePASS eliminates the FirePASS is perfect for A change of use in the fire pro tection: Fire prevention. While all risk of having damage cool storages: It is easy protected area doesn t other systems only react when fire and caused to delicate goods to install and delivers create any need for damage is already occurring, FirePASS is and food by fire, smoke continuous protection changes to the FirePASS proactive and still allows access and per- or extinguishing agents. even at very low tempe- installation. manent occupation of the fire-prevented ratures without any risk room at all times. of freezing water-pipes, valves or nozzles. industrial similar areas Control rooms typically contain the core steering elements of complex activities. Any loss of control may cause immense costs, damages and, in FirePASS assures continuous operation and allows permanent access and occupation without interruption thus avoiding any loss of control. some cases even hazard In any situation in which the highest level of fire protection is essential, FirePASS is the first choice. Amongst many other ap- to many human beings. Even a brief black-out is intolerable. plications this applies for high value technical installations like servers, telecommunications and control rooms where un- Documents, historic artifacts, paintings, etc. are FirePASS not only prevents the outbreak of any interrupted operation is a must, for ex- all irreplaceable goods fire and avoids collateral ample, or for irreplaceable items such as of high real or ideational damage by extinguishing museum exhibits and archived documents value. They are destroyed agents, but also reduces and for valuable goods on store. or strongly damaged by deterioration due to the fire, water, smoke and reduced oxygen content chemicals. of the hypoxic air pro- 06 duced.

Further FirePASS applications Implementing FirePASS systems - Electrical switching and battery rooms - Confined spaces on ships - Offshore platforms - Safe vaults - Libraries - Ammunition bunkers - Cable tunnels and many, many more. FirePASS not only prevents the damage of goods and equipment but also annihilates environmental risks and collateral damages of fire and fire extinguishing systems. FirePASS is easily installed in already existing premises as well as in newly built spaces. When planning for a FirePASS system the following should be known: - FirePASS systems consume little space compared to conventional systems and don't need any distribution piping within the protected spaces. The only requirement is simple, zero-pressure piping to each protected area and to the ambient air outside as well as wiring of the oxygen monitoring units in the protected areas. - The protected areas should be equipped with highly sen sitive smoke detectors. - A comfortable, breathable atmosphere is created inside the con fined spaces by the constant ventilation with fresh hypoxic air. - The highly reliable hypoxic air generators need very little maintenance cycle of 6 months is typical. - FirePASS systems can be used as an alternative, but also as a complementary or supplementary option which enhances the conventional fire-safety means without interfering with their performance. - Note: The protected areas have to be confined spaces that are well sealed in order to minimize the permanent leakage of air in and out of the room. All spaces included in the fire prevention must have split-type air cooling or closed, dedicated air recirculation systems. 08 09

1. Certainty of avoiding the outbreak and spread of fire 2. Retaining access to protected areas at any time 3. Proactive and permanent fire protection to secure business processes and valuable goods 4. Protecting multiple hazards with just one system Fire protection without any interruption no refilling or replacement needed 6. Absolute safety for human beings through using breathable air as the agent no nitrogen-injection 7. Environmentally friendly no chemicals used 8. Scalable to any size of protected areas and number of compartments no design limitations 9. Very small foot-print and little building space needed 10. Easy to install and maintain 11. No excessive piping, no nozzles, no pressurized cylinders or pipes, no leaking, no expensive refilling 12. No damages by fire, released water, foam or other extinguishing agents, no false discharges, no discharge failures 13. No loss of work time through activated fire alarm systems, no disruption of working processes, no consequential costs 14. No closing of unusable areas due to fire damages, clean-up or repair

History of FirePASS 2011 FirePASS has a large and constantly growing network of partners ensuring local presence and quick service response. Currently Fire PASS partners offer consulting, sales, maintenance, repair and customer support in more than 60 countries worldwide. 2010 FirePASS International AG is founded to market FirePASS Switzerland, and additional production centers located in Netherlands and the United States of America.»The revolutionary FirePASS hypoxic air technology is the first and best choice for fire protection in any enclosed space. The unique approach of using breathable air guarantees unmatched fire safety and absolute safety for human beings at the same time.«2009 Boeing Company and Honeywell International obtain a license from FirePASS for the use of its technology in airplanes. Ludwig W. Allgoewer President & CEO 2008 First commercial installations of FirePASS systems are realized in Norway, Spain and the USA. 2007 The United States Federal Aviation Administration (FAA) adopted FirePASS technology for protecting fuel tanks on all commercial airplanes. 12 2006 The inventor Igor Kotlyar receives the first regis trations for his patents regarding FirePASS technology and its applications. 13

FirePASS International AG Rötelistrasse 12 9000 St. Gallen Switzerland www.firepass.ch Phone +41 (0)