Mechanical Compliance Certificate

Similar documents
COMcheck Software Version Mechanical Compliance Certificate

COMcheck Software Version Mechanical Compliance Certificate

COMcheck Software Version Mechanical Compliance Certificate

COMcheck Software Version Mechanical Compliance Certificate

COMcheck Software Version

HVAC Mandatory Provisions Part II, Page 1

COMcheck Software Version Review Mechanical Compliance Certificate

COMcheck Software Version Mechanical Compliance Certificate

COMcheck Software Version Mechanical Compliance Certificate

COMcheck Software Version Interior Lighting Compliance Certificate

COMcheck Software Version Interior Lighting Compliance Certificate

2009 IECC Commercial Mechanical Requirements

August 15, 2013 Page 1 of 19

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

ONTARIO BUILDING CODE AND SUPPLEMENTARY STANDARD SB-10 PROJECT INFORMATION. Mechanical Designer Information*

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

1 - This title will copy onto other forms Date

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SESSION Michigan Energy Code (MEC) Update (3 Technical) Per SMACNA Standard (TAB, Duct Design) and ASHRAE ( ) ASHRAE Detroit Members:

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

August 27, Section 3.2 Definitions. On page 11 delete the following definition:

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

2006 Washington State Nonresidential Energy Code Compliance Form Washington State Nonresidential Energy Code Compliance Forms Revised July 2007

Job Name Control Systems Description Date

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

2011 Manitoba Energy Code for Buildings (MECB) PART 5, Heating, Ventilating and Air-conditioning Systems

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

HVAC Controls Upgrades: Requirement Details ( )

b.) Technical Information:

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

ASHRAE/IESNA Standard

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

HVAC Controls Upgrades: Requirement Details ( )

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

PRE-PRINT APPENDIX E GREEN MECHANICAL CODE SUPPLEMENT

Inspection Phase Three. Mechanical, Electrical & Plumbing Section 503

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

Application of the 2012 North Carolina Energy Conservation Code

Digital Precise Air Control - DPAC

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

Gil Rossmiller. In the construction industry for over 30 years. ICC IRC Plumbing & Mechanical Code Development Committee

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

UNIFIED FACILITIES GUIDE SPECIFICATIONS

TESTING, ADJUSTING AND BALANCING

2009 Washington State Non-Residential Energy Code Scott Rushing, PE, LEED AP - Rushing Company Lisa Rosenow, CSBA, LEED AP NEEC

EADQUARTERS. Technical Report One. Stephanie Kunkel Mechanical Option

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)

C.E.P., C.E.M, C.I.P.E.

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

City of Duluth Festival Center 04/25

CHAPTER 4. HVAC DELIVERY SYSTEMS

Energy Recovery with Cooling and Heating Model ERCH

Agenda and Objectives

Computing Services Center

INDEX. ADDITIONS AND ALTERATIONS Defined Requirements ADMINISTRATION AND ENFORCEMENT... Chapter 1 AIR ECONOMIZERS

Your Home. Jacco & Assoc.

10+ HVAC Troubleshooting Tips for Healthcare Facilities Jerry Hirsch JCI Facility O&M Performance Development Manager.

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

DX-9100 Applications from Engineering Services

Verasys System Operation Overview Technical Bulletin

Feature Summary. I. System

Table of Contents. List of Figures and Tables. Executive Summary: 3 ASHRAE Standard 62.1 Section 6 Analysis 7

SEQUENCE OF OPERATION GUIDELINE. AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT

Technical Assignment 1

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

Energy-Efficiency Measures List

Design Considerations For Dedicated OA Systems BY HUGH CROWTHER, P.ENG, MEMBER ASHRAE; YI TENG MA, ASSOCIATE MEMBER ASHRAE

Union County Vocational - Technical Schools Scotch Plains, New Jersey

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

HVAC Trajectories toward Zero

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

ASHRAE Standard 90.1 Energy Requirements Wrap-Around Heat Pipes

SECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW...

Zoned Rooftop Systems. Light commercial packaged rooftop systems from Trane

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Benefits Offered by Passive Dehumidification Wheel Speed Control

8 5.11: Finned-Tube Coils and Heat Exchangers : Humidifiers and Water Spray Systems : Access for Inspection, Cleaning, and Maintenance

Advanced Installation and Configuration Instructions

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

AHRI Certification Program Scopes - COOLING

Power and Energy Management Solutions

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP RECIRCULATION AIR WITH ECONOMIZER

Model 8142 and 8142NC Fresh Air Ventilator Installation and Operating Instructions

Appendix 13. Categories of Cooling and Heating systems

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Pharmaceutical Facility Design

Cleveland Clinic Design Standards MECHANICAL SYSTEMS DESIGN GUIDELINES HVAC AIR DISTRIBUTION PART I - GENERAL 1.1 SUMMARY

UFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas

REPRODUCTION/DISTRIBUTION IS PROHIBITED. Energy-Savings Strategies for. Rooftop

Transcription:

COMcheck Software Version 4.0.7.0 Mechanical Compliance Certificate Project Information Energy Code: Location: Climate Zone: Project Type: 90.1 (2013) Standard Austin, Texas 2a (weather data: TBD) New Construction Construction Site: 6800 Burleson Road Building 3 Austin, TX 78744 Owner/Agent: Designer/Contractor: Ethan Wagner MEJ & Associates, Inc. 811 Barton Springs Road Suite 700 Austin, TX 78704 (512) 457-8771 Mechanical Systems List Quantity System Type & Description 1 CRAC/ACCU1_4 (Single Zone): Cooling: 1 each - Computer Room AC Downflow Unit, Capacity = 140 kbtu/h, Air-Cooled Condenser, No Economizer, Economizer exception: Computer Room Applications Proposed Efficiency = 2.36 SCOP-127, Required Efficiency: 2.10 SCOP-127 Fan System: FAN SYSTEM 1 Server -- Compliance (Motor nameplate HP method) : Passes Fans: CRAC/ACCU1_4 Supply, Constant Volume, 6200 CFM, 3.1 motor nameplate hp, 80.0 fan efficiency grade Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.0.7.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Ethan Wagner, P.E. Name - Title Signature Date Page 1 of 9

COMcheck Software Version 4.0.7.0 Inspection Checklist Energy Code: 90.1 (2013) Standard Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section 4.2.2, 6.4.4.2.1, 6.7.2 [PR2] 1 4.2.2, 8.4.1.1, 8.4.1.2, 8.7 [PR6] 2 6.7.2.4 [PR5] 1 Plan Review? Comments/Assumptions Plans, specifications, and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. Plans, specifications, and/or calculations provide all information with which compliance can be determined for the electrical systems and equipment and document where exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. Detailed instructions for HVAC systems commissioning included on the plans or specifications for projects >=50,000 ft2. Page 2 of 9

Footing I Foundation Inspection? Comments/Assumptions 6.4.3.7 Freeze protection and snow/ice Dcomplies I I [F09]3 melting system sensors for future Dooes Not connection to controls. O D 1 1I High Impact (Tier 1) I 2 I Medium Impact (Tier 2) I 3 I Low Impact (Tier 3) Data filename: G:\6800 Burleson, 8310\CTECC, L1 2017\mechanicai\MECH COMCHECK.cck Page 3 of 9

6.4.1.4, 6.4.1.5 [ME1] 2 6.4.3.4.1 [ME3] 3 6.4.3.4.5 [ME39] 3 6.4.3.4.4 [ME5] 3 6.4.3.8 [ME6] 1 6.5.3.2.1 [ME40] 2 6.4.4.1.1 [ME7] 3 6.4.4.1.2 [ME8] 2 Mechanical Rough-In Inspection HVAC equipment efficiency verified. Non-NAECA HVAC equipment labeled as meeting 90.1. Stair and elevator shaft vents have motorized dampers that automatically close. Enclosed parking garage ventilation has automatic contaminant detection and capacity to stage or modulate fans to 50% or less of design capacity. Ventilation fans >0.75 hp have automatic controls to shut off fan when not required. Demand control ventilation provided for spaces >500 ft2 and >25 people/1000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. DX cooling systems >= 75 kbtu/h (>= 65 kbtu/h effective 1/2016) and chilled-water and evaporative cooling fan motor hp >= ¼ designed to vary indoor fan airflow as a function of load and comply with operational requirements. Insulation exposed to weather protected from damage. Insulation outside of the conditioned space and associated with cooling systems is vapor retardant. HVAC ducts and plenums insulated. Where ducts or plenums are installed in or under a slab, verification may need to occur during Foundation Inspection. Plans Verified Efficiency: R- Field Verified Efficiency: R-? 6.4.4.1.3 HVAC piping insulation thickness. in. in. [ME9] 2 Where piping is installed in or under a slab, verification may need to occur during Foundation Inspection. 6.4.4.1.4 [ME41] 3 6.4.4.2.1 [ME10] 2 Thermally ineffective panel surfaces of sensible heating panels have insulation >= R-3.5. Ducts and plenums sealed based on static pressure and location. Comments/Assumptions See the Mechanical Systems list for values. See the Mechanical Systems list for values. Page 4 of 9

Mechanical Rough-In Inspection Plans Verified Field Verified? Comments/Assumptions 6.4.4.2.2 [ME11] 3 Ductwork operating >3 in. water column requires air leakage testing. 6.5.2.3 [ME19] 3 Dehumidification controls provided to prevent reheating, recooling, mixing of hot and cold airstreams or concurrent heating and cooling of the same airstream. 6.5.2.4.1 [ME68] 3 Humidifiers with airstream mounted preheating jackets have preheat auto-shutoff value set to activate when humidification is not required. 6.5.2.4.2 [ME69] 3 Humidification system dispersion tube hot surfaces in the airstreams of ducts or airhandling units insulated >= R- 0.5. 6.5.2.5 [ME70] 3 Preheat coils controlled to stop heat output whenever mechanical cooling, including economizer operation, is active. 6.5.3.5 [ME72] 2 Motors for fans >= 1/12 hp and < 1 hp are electronicallycommutated motors or have a minimum motor efficiency of 70%. These motors are also speed adjustable for either balancing or remote control. 6.5.3.3 [ME42] 3 Multiple zone VAV systems with DDC of individual zone boxes have static pressure setpoint reset controls. See the Mechanical Systems list for values. 6.5.4.2 [ME25] 3 HVAC pumping systems >10 hp designed for variable fluid flow. 6.5.6.1 [ME56] 1 Exhaust air energy recovery on systems meeting Tables 6.5.6.1-1, and 6.5.6.1-2. 6.5.7.1.1 [ME32] 2 Kitchen hoods >5,000 cfm have make up air >=50% of exhaust air volume. 6.5.7.1.2 [ME46] 3 Conditioned supply air to space with a kitchen hood shall not exceed the greater of a) supply flow required to meet space heating or cooling, or b) hood exhaust flow minus the available air transfer from available spaces. Page 5 of 9

Mechanical Rough-In Inspection Plans Verified Field Verified? Comments/Assumptions 6.5.7.1.5 [ME49] 3 Approved field test used to evaluate design air flow rates and demonstrate proper capture and containment of kitchen exhaust systems. 6.5.8.1 [ME34] 2 Unenclosed spaces that are heated use only radiant heat. 6.4.3.9 [ME63] 2 Heating for vestibules and air curtains include automatic controls that shut off the heating system when outdoor air temperatures > 45F. Vestibule heating systems controlled by a thermostat in the vestibule with setpoint <= 60F. 6.5.10 [ME73] 3 Doors separating conditioned space from the outdoors have controls that disable/reset heating and cooling system when open. Page 6 of 9

8.4.2 [EL10] 2 10.4.1 [EL9] 2 Rough-In Electrical Inspection? Comments/Assumptions At least 50% of all 125 volt 15- and 20-Amp receptacles are controlled by an automatic control device. Electric motors meet requirements where applicable. Page 7 of 9

6.4.3.1.2 Thermostatic controls have a 5 F [FI3] 3 deadband. 6.4.3.2 [FI20] 3 6.4.3.3.1 [FI21] 3 6.4.3.3.2 [FI22] 3 6.4.3.6 [FI6] 3 6.7.2.1 [FI7] 3 6.7.2.2 [FI8] 3 6.7.2.3 [FI9] 1 6.7.2.4 [FI10] 1 10.4.3 [FI24] 2 Final Inspection? Comments/Assumptions Temperature controls have setpoint overlap restrictions. HVAC systems equipped with at least one automatic shutdown control. Setback controls allow automatic restart and temporary operation as required for maintenance. When humidification and dehumidification are provided to a zone, simultaneous operation is prohibited. Humidity control prohibits the use of fossil fuel or electricity to produce RH > 30% in the warmest zone humidified and RH < 60% in the coldest zone dehumidified. Furnished HVAC as-built drawings submitted within 90 days of system acceptance. Furnished O&M manuals for HVAC systems within 90 days of system acceptance. An air and/or hydronic system balancing report is provided for HVAC systems serving zones >5,000 ft2 of conditioned area. HVAC control systems have been tested to ensure proper operation, calibration and adjustment of controls. Elevators are designed with the proper lighting, ventilation power, and standby mode. Page 8 of 9

Page 9 of 9