BK 46. Installation Instructions Steam Trap BK 46

Similar documents
MK 45 A. Stainless Steel Design. Installation Instructions Steam Trap MK 45 A

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

GESTRA Steam Systems ER 50-1, ER Installation Instructions Level electrode

GESTRA. Program for Universal Connections. The Smart Solutions

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode

SMK 22 SMK SMK SMK 22-82

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

TRG 5-6x. GESTRA Steam Systems. Installation Instructions

BK 45 BK 45-U BK 45-LT BK 46

GESTRA Steam Systems NRGS 11-2, NRGS Installation Instructions Level Electrode Types

TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57

NRG NRG NRG NRG

Installation & Operating Instructions

Level Electrode NRG NRG Original Installation Instructions English

Temperature Sensor TRG Original Installation Instructions English

THERMODYNAMIC STEAM TRAP

Steam Traps and Steam Trap Testing

Level Electrode NRG Original Installation Instructions English

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

FT14 Ball Float Steam Trap (Screwed)

Operating and installation instructions

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Conductivity Electrode LRG Original Installation Instructions English

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

FT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

Model: 1100 Float-Controlled Condensate Trap, PN 25

GESTRA Information A 1.5

GESTRA Information A 1.7

INSTALLATION, OPERATION

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

GESTRA Steam Systems OR Installation Instructions Oil & Turbidity Detector OR 52-7

FLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25)

Mechanical seals external, single or double, to DIN EN 12756

GESTRA. Steam traps and monitoring equipment. The right choice in every case

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

Installation and Maintenance Manual Forbes Marshall Bucket Trap FMBT50

Product overview. the optimum components for every application

INSTALLATION, OPERATION

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

GESTRA. Product Overview. The optimum components for every application

GESTRA. Product Overview. The optimum components for every application

INSTALLATION, OPERATION

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

MFP14 Automatic pumps. for condensate and other industrial fluids

GESTRA. Steam Traps and Steam Trap Testing. For all applications

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

LIQUIDATOR UMT-TD Series Thermodynamic

GESTRA Steam Systems NRS English. Installation Instructions Level Switch NRS 1-51

THERMODYNAMIC STEAM TRAPS

Installation and Maintenance Manual

LIQUIDATOR 450 SERIES

THERMODYNAMIC STEAM TRAPS

! WARNING. Before using product, read and understand instructions.

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

Liquid Drainers LIQUID DRAINERS

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Instructions for Installation, Operation, Care and Maintenance

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.

MFP14 Automatic pumps for condensate and other industrial fluids

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

CD-33/CD-33S Controlled Disc Steam Traps

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

STEAM TRAPS

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

THERMOSTATIC STEAM TRAPS

SuperKlean Washdown Products

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

FLOW HEATER 32E X 2R IMPORTANT GENERAL INFORMATION: SPECIFICATION. Instruction Manual. Article number: 045a-105 Electric heating capacity:

Inverted Bucket Steam Traps

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

1592P01. for liquids in piping DN

Yarway Narvik Steam Desuperheater Series 4300 TempLow

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

TECHNICAL DATA. Wet 26a. February 22, 2009

Water level controller and limiter

HKF 8180 Operating instructions

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

Installation of Glass Lined Equipment

PIP PNE00004 Steam Trap Guidelines

1. Description INSTRUCTION FOR BLAST COOLER TYPE COOL 250. Material

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

GESTRA Steam Systems NRS For TWO Electrodes. English. Installation Instructions Level Switch NRS 1-50

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES. Manufacturer

Transcription:

BK 46 Installation Instructions 810645-00 Steam Trap BK 46 1

Capacity Chart 2 1 Fig. 1 1 2 Max. discharge capacity of hot condensate Max. discharge capacity of cold condensate 2

Design A B C D D E E1 F G H I Fig. 2 J 3

Key A B C D E Hexagon-head screw M10x25, EN 24027 made of 1.7225 Name plate Cover Regulator Bush (interference fit, not a spare part) E1 Protective sleeve against wear (interference fit, not a spare part) F Cover gasket 40 x 48 x 2 G Body H Strainer I Plug gasket A 24 x 29 J Strainer plug 4

5

Contents Page Important Notes Use... 7 Important safety note... 7 Danger...7 Explanatory Notes Scope of supply... 8 Description... 8 Function... 8 Technical data... 9 Name plate and ratings...10 Installation BK 46...10 Flanged design...10 Screwed-socket design...10 Socket-weld design...11 Heat treatment of welds...11 Operation Factory setting...11 Maintenance Check steam trap...12 Clean/replace regulator and nozzle insert...12 Clean/replace strainer...12 Torques...13 Spare Parts Spare parts list...13 6

Important Notes Use Use steam trap BK 46 only for the discharge of condensate in steam lines within the admissible pressure/temperature ratings. Check the chemical resistance and suitability of the steam trap for the application in question. Important Safety Note The steam trap may only be installed by qualified staff. Qualified staff are those persons who through adequate training in engineering, the use and application of equipment in accordance with regulations concerning steam systems, and first aid & accident prevention have achieved a recognised level of competence appropriate to the installation and commissioning of this device. Danger The trap is under pressure during operation. When disassembling or opening the trap, loosening the plug or regulator, hot water and steam may escape. This presents the risk of severe burns to the whole body. Installation and maintenance work should only be carried out when the system is depressurized: isolate the trap from both upstream and downstream pressure. The trap becomes hot during operation. This presents the risk of severe burns to hands and arms. Installation and maintenance work should only be carried out when the system is cold. Sharp edges on internal parts present a danger of cuts to hands. Always wear industrial gloves for installation and maintenance work. 7

Explanatory Notes Scope of Supply BK 46 1 Steam trap type BK 46 1 Installation manual Description Thermostatic steam trap with corrosion-resistant thermostatic element (Duo stainless steel bimetallic regulator) unaffected by waterhammer. With Y-type strainer, nonreturn valve and asbestos-free cover gasket (graphite). Installation in any position. The standard version discharges condensate with virtually no banking-up. Function During start-up of the plant the Duo stainless steel plates are flat. The service pressure acts in the opening direction, the valve is completely open. As the condensate temperature rises, the plates deflect, drawing the stage nozzle towards the closed position. As the condensate temperature sinks, the deflection of the Duo stainless steel plates decreases and the steam trap opens at the adjusted opening temperature. The thermostatic and spring characteristics of the stack of plates are balanced such that condensate is always discharged at a given undercooling temperature. The trap provides automatic air-venting at start-up and during operation. BK 46 can also be used for thermal air-venting in steam systems. 8

Technical Data Pressure/temperature ratings BK 46, PN 40 Max. service pressure PMA [barg] 35 32 28 [psig] 508 464 406 Related temperature TMA [ C] 300 335 450 [ F] 572 634 842 Max. differential pressure (inlet pressure minus outlet pressure) PMX 32 barg (464 psig) Materials Body Cover Screws Body gasket Regulator Other internals DIN New designation Old designation 15 Mo 3 (1.5415) 15 Mo 3 (1.5415) 42 CrMo 4 (1.7225) Graphite Stainless steel Stainless steel ASTM A 182 F 1 (DIN equivalent) 1 ) A 182 F 1 (DIN equivalent) 1 ) A 193 B 7 1 ) Physical and chemical properties comply with DIN grade. ASTM nearest equivalent grade is stated for guidance only. 9

Explanatory Notes continued Name Plate / Ratings Reference point for ultrasonic functional test Nominal size Regulator Standard design Ratings acc. to EN ISO 26552 For further specifications according to EN 19 see trap body. Fig. 4 Installation BK 46 The steam trap BK 46 can be installed in any position. In the case of a horizontal installation, make sure that the cover is at the top. Flanged Design 1. Take care of correct position of installation. 2. Take care of flow direction. The flow arrow is on the trap body. 3. Consider space required for opening trap. When the trap is installed a minimum space of 70 mm is required for removing cover C. 4. Remove plastic plugs. They are only used as transit protection. 5. Clean seating surfaces of both flanges. 6. Install steam trap. Screwed-Socket Design 1. Take care of correct position of installation. 2. Take care of flow direction. The flow arrow is on the trap body. 3. Consider space required for opening trap. When the trap is installed a minimum space of 70 mm is required for removing the cover C. 4. Remove plastic plugs. They are only used as transit protection. 5. Clean female thread of screwed sockets. 6. Install steam trap. 10

Installation continued Socket-Weld Design 1. Take care of correct position of installation. 2. Take care of flow direction. The flow arrow is on the trap body. 3. Consider space required for opening trap. When the trap is installed a minimum space of 70 mm is required for removing the cover C. 4. Remove plastic plugs. They are only used as transit protection. 5. Remove regulator as described under Maintenance. 6. Clean socket-weld ends. 7. Arc-weld trap only manually (welding process 111 and 141 in accordance with DIN EN 24053). Attention Only qualified welders certified e. g. according to DIN EN 287 may weld the steam trap into pressurized lines. Do not insulate the steam trap. Heat Treatment of Welds A subsequent heat treatment of the welds is not required. Operation Factory Setting The factory setting ensures that the steam trap works without loss of live steam and with virtually no banking-up of condensate. Any modification of the default setting will displace the opening and closing curve of the trap towards the saturation curve and would result in loss of live steam and/or could lead to a substantial undercooling which would give rise to condensate banking-up. We therefore highly recommend not to change the factory setting. 11

1. Take heed of the note Danger on page 7. 2. Undo body screws A. Remove cover C from the body G. 3. Remove and clean regulator D. 4. Replace regulator D in case of visible signs of wear or damage. 5. Clean body, internals and all gasket surfaces. 6. Apply heat-resistant lubricant to all threads and the seating surface of the nozzle insert and the cover (use for instance WINIX 2150). 7. Screw in regulator and tighten with a torque of 90 Nm. 8. Replace gasket F if there are visual signs of damage. Use the same cover C. Always replace gasket F when using a new cover C or the cover of another steam trap. 9. Put cover onto the body. Tighten body screws A alternately and in several steps to a torque of 25 Nm. 1. Take heed of note Danger on page 7. 2. Unscrew sealing plug J and remove strainer H. 3. Clean strainer, sealing plug and gasket seats. 4. Exchange strainer and sealing plug in case of visible signs of wear or damage. 5. Exchange gasket I if damaged. 6. Apply heat-resistant lubricant to the thread of the sealing plug (use for instance WINIX 2150). 7. Replace gasket I and strainer H and tighten sealing plug J with a torque of 120 Nm. 12 Maintenance The thermostatic steam trap BK 46 does not require any special maintenance. However, if used in new installations which have not been rinsed it may be necessary to check and clean the trap. Check Steam Trap You can check the steam trap BK 46 for steam loss during operation using the ultrasonic measuring unit VAPOPHONE or the test unit TRAPtest. The reference points are at the name plate on the cover. see Fig. 4 Should you detect any loss of live steam clean the trap and/or replace the regulator. Clean/Replace Regulator and Nozzle Insert Tools Spanner A. F. 16 mm to DIN 3113, form B Spanner A. F. 22 mm to DIN 3113, form B Torque spanner 20 120 Nm to DIN ISO 6789 Clean/Replace Strainer Tools Spanner A. F. 30 mm to DIN 3113, form B Torque spanner 20 120 Nm to DIN ISO 6789 WINIX is a registered trademark of WINIX GmbH, Norderstedt

Maintenance continued Torques Item D A Designation Regulator Body screws Torque [Nm] 090 025 J Sealing plug 120 All torques given in the table are based on an ambient temperature of 20 C. Spare Parts Spare Parts List Item Designation Stock code D F Regulator 375 464 H I J Strainer set, complete 375 113 F I Cover gasket*) 40 x48 x 2, graphite Plug gasket*) A24 x 29, stainless steel 375 159 375 162 *) Minimum purchasing quantity 50 pcs. Contact your local dealer for smaller quantities. 13

GESTRA Gesellschaften GESTRA Companies Sociétés GESTRA Sociedades Gestra Società GESTRA Vertretungen weltweit Agencies all over the world Représentations dans le monde entier Representaciones en todo el mundo Agenzie in tutto il mondo España GESTRA ESPAÑOLA S.A. Luis Cabrera, 86-88 E-28002 Madrid Tel. (091) 00 3459152 / 5 152 032 032 Fax (091) 003491/4136747; 4 136 (091) 5152036 5 036 E-mail: gestra@gestra.es France France Invensys Flow Control France Flowserve SASFlow Control S. A. S. 10 Avenue du Centaure, BP 8263 F-95801 CERGY PONTOISE CEDEX Tél. (01) 0 0334.43.26.60 31 / 43 60 Fax (01) 00331/34432687 34.43.26.87 E-mail: gnation@flowserve.com gnation@gestra.fr Polska GESTRA POLONIA Spolka z o.o. Ul. Schuberta 104, P. O. Box 71 PL-80-172 Gdansk Tel. (058) 00 48306 58 / 306 10 0210 02 oder 306 10 10 Fax (058) 00 48306 58 / 306 10 0310 03 oder 306 33 00 E-mail: gestra@gestra.pl Portugal Portugal GESTRA PORTUGUESA VALVULAS LDA. Av. GESTRA Dr. Antunes PORTUGUESA Guimarães, VALVULAS 1159 LDA. P-4100 Av. Dr. Antunes Porto Guimarães, 1159 Tel. Porto (022) 4100-082 6 19 87 70 Fax Tel. (022) 0035122/6198770 6 10 75 75 E-mail: Fax 00351 gestra@gestra.pt 22 / 6 10 75 75 E-mail: gestra@gestra.pt Italia Italia Invensys Flow Control Division Italgestra S.r.l. Italgestra S.r.l. Via Carducci 125 Via Carducci 125 l-20099 Sesto San Giovanni (MI) l-20099 S.S. Giovanni (MI) Tel. 00 39 02 / 24 10 12.1 Tel. (02) 24 10 12 1 Fax 00 39 02 / 24 10 12.460 Fax (02) 24 10 12 460 E-mail: info@italgestra.it E-mail: info@italgestra.it GESTRA GmbH Postfach 10 54 60 D-28054 Bremen Hemmstraße Münchener Str. 130 77 D-28215 Bremen Tel. +49 (0) 421 35 03-0 Fax +49 (0) 421 35 03-393 E-mail gestra.gmbh@gestra.de Internet www.gestra.de An A Unit Invensys of Flowserve company Corporation 810645-00/201c 2001 GESTRA GmbH Bremen Printed in Germany 14