~,oeti. Report VN Classification Report. Reference

Similar documents
~~oeti. Report VN71 O Classification Report. Reference

Report VNLF Test Report

Report VNNF Test Report

Report Test Report

Report Classification Report on Burning Behaviour

TFI Report Classification

Analysis Report

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

TFI Report Classification

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Analysis Report

BCTC CARPET TECHNICAL CENTRE

Reaction to fire classification report No C-rev.1

Reaction to fire classification report No C

Test Report No

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

TFI Report Reaction to fire test

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

Additional reaction to fire classification report No H

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

BS EN ISO : 2010

Shipboard incinerators with capacities up to 4000 kw

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Centexbel. General certification regulations. Construction products

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

Review Fire Test Report

DELTA Classification Report

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

Test Report: ICL/H18/9039 Rev 1

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

BS EN ISO : 2010

Classification Report

ISO INTERNATIONAL STANDARD. Non-destructive testing Penetrant testing Part 2: Testing of penetrant materials

BS EN ISO : 2010


ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

ISO INTERNATIONAL STANDARD

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

3th International Conference in Warsaw "MODERN TRENDS OF FIRE PROTECTION IN ROLLING STOCK"

Üntel is ready for CPR

Centrum stavebního inženýrství a.s.

ISO INTERNATIONAL STANDARD

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE

Additional Reaction to Fire Classification Report

Procedure for the Approval of New Fire Detection and Alarm Technologies

ISO INTERNATIONAL STANDARD

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

ISO INTERNATIONAL STANDARD. Footwear Test methods for whole shoe Washability in a domestic washing machine

+ = FIRE LABORATORY INTRODUCTION. APPLUS+ LGAI - Our company history. High Technology Knowledge. Customer Confidence. Branding

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

Contact person Date Reference Page Richard Johansson P (2) Fire Research

ISO INTERNATIONAL STANDARD

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

TECHNICAL SPECIFICATION

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

Loss Prevention Standard

This document is a preview generated by EVS

EUROPUMP ATEX Guideline Part II

ISO 1806 INTERNATIONAL STANDARD. Fishing nets Determination of mesh breaking force of netting

MEDIUM-DENSITY HOUSING # 7. Fire safety

INTERNATIONAL STANDARD

Cable Ties JULY The electronic pdf version of this document found through is the officially binding version

ISO/TS TECHNICAL SPECIFICATION. Fire detection and alarm systems Part 9: Test fires for fire detectors

IMO Resolution MSC 61(67): Annex 1: Part 2

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

Chief Operating Officer Giampiero Belcredi

Resilient, textile and laminate floor coverings - Classification (ISO 10874:2009)

Conformity assessment procedures for the Alarm Components Scheme

ISO 2411 INTERNATIONAL STANDARD. Rubber- or plastics-coated fabrics Determination of coating adhesion

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

Review of reports and data for Aero-Therm thermal reflective coating. Prepared for: Mr Craig Clement Director

Glass fibre rovings - Non-metallic materials

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

REACTION TO FIRE TESTS FOR BUILDING PRODUCTS DETERMINATION OF THE HEAT OF COMBUSTION ACCORDING TO STN EN ISO 1716: 2003

Centrum stavebního inženýrství a.s.

This document is a preview generated by EVS

FIRST-CLASS IN TRAINS

Test Report: ICL/CR15/11/087

PUBLIC SUMMARY REPORT OF THE EGOLF EN 13823

YOUR GUIDE TO UNDERSTANDING CPR

INTERNATIONAL STANDARD

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

ISO/TS TECHNICAL SPECIFICATION

ISO INTERNATIONAL STANDARD

gent warn nfire No, 16209C Reaction to fire class ification report lntroduction Owner of the classification report

Significance of the Construction Products Regulation, including for data centers WHITEPAPER

ISO INTERNATIONAL STANDARD

HazLoc Essential Guides:

Transcription:

~,oeti Report VN710 140527.2 Classification Report ~ ~ 1so111:e 1102s "\ Applicant EGETAEPPER A/S lndustrivej Nord 25 7400-Herning Denmark Reference Lenette Ormstrup Application Classification of burning behaviour according to EN 13501-1. Test material "PA-WT" {CH-s1) Material used in testing was anonymized for laboratory purposes. A detailed sample list is contained in the report. Issuing and Signatures Number of pages contained: 8 Original Issue/ Vienna 12.06.2018 / da2 / 201 Authorised for Institute Ing. Hannes Vittek ÖTI - Institut für Ökologie, Technik und Innovation GmbH I Spengergasse 20, 1050Vienna, Austria tel +43 1 5442543-0 I fax +43 1 5442543-10 I email office@oeti.at I FN 326826b I VAT No. ATU65149029 UniCredit Bank Austria AG I IBAN AT941200023410378800 I BIC BKAUATWW I EORI ATEOS1000015903 Es gelten ausschließlich unsere Allgemeinen Geschäftsbedingungen I Only our general terms and conditions apply Member oftestex Group

VN710 140527.2 2 / 8 Contents 1 Order... 2 1.1 Chronology... 2 2 Introduction... 2 3 Details of classified building product... 2 3.1 General... 2 3.2 Description of the building product... 3 4 Test reports and test results for the proof of the classification... 5 4.1 Test report... 5 4.2 Test results... 6 5 Classification and field of application... 7 5.1 Reference for classification... 7 5.2 Classification... 7 5.3 Field of application... 7 6 Limitations... 7 6.1 Notice... 7 7 Remarks... Fehler! Textmarke nicht definiert. 1 Order 1.1 Chronology Date Received Order 05.04.2018 13.04.2018 Classification of burning behaviour according to EN 13501-1. 2 Introduction This classification report defines the classification assigned to the building product group PA-WT (C fl s1) in accordance with the test methods fixed in EN 13501-1. 3 Details of classified building product 3.1 General The building product group PA-WT (C fl s1) is defined as flooring, the classification is valid for the end use application described under point 5.3.

VN710 140527.2 3 / 8 3.2 Description of the building product The building product group PA-WT (C fl s1) is defined according EN 14041 as following. Type Textile floor coverings with pile according to EN 1307 Dimensions Rolls Manufacturing technique Tufted Surface structure Cut pile Backing Woven Secondary Backing Pile material 100% Polyamide Total weight 2150 3550 g/m² Total thickness 7,0 15,5 mm Pile weight 750 2000 g/m² Pile thickness 4,5 13,0 mm Type Textile floor coverings with pile according to EN 1307 Dimensions Rolls Manufacturing technique Tufted Surface structure Loop pile Backing Woven Secondary Backing Pile material 100% Polyamide Total weight 2050 2750 g/m² Total thickness 5,0 8,0 mm Pile weight 440 1100 g/m² Pile thickness 3,0 4,0 mm Type Textile floor coverings without pile according to EN 1307 Dimensions Rolls Manufacturing technique Woven (flat woven) Surface structure Loop similar (plain, ribbed and structured) Backing Woven Secondary Backing Pile material 100% Polyamide Total weight 1800 2600 g/m² Total thickness 3,0 4,5 mm Pile weight 345 700 g/m² The applicant of this classification report guarantees the observance of the instructions for building product groups according EN 14041 as well as the observance of the instructions of the product specification according to EN 1307.

VN710 140527.2 4 / 8 The following articles are part of the building product group PA-WT (C fl s1). Article Surface Structure Manufacturing technique Total weight [g/m²] Total thickness [mm] Pile weight [g/m²] Pile thickness [mm] Contract 2018 WT Cut Tufted 2150 7,0 750 5,0 Epoca Moss WT Cut Tufted 2925 11,5 1750 9,0 Epoca Silky WT Cut Tufted 3050 11,5 1500 9,0 Epoca Texture WT Cut Tufted 2650 8,0 1100 5,5 Epoca Texture 2000 WT Cut Tufted 3550 15,5 2000 13,0 Epoca Twist WT Cut Tufted 2700 8,0 1100 5,5 Highline 1100 WT Cut Tufted 2550 8,0 1100 5,5 Highline 750 WT Cut Tufted 2250 7,0 760 4,5 Highline 910 WT Cut Tufted 2350 7,5 910 5,0 Ege Tuft 440 WT Loop Tufted 2050 5,5 440 3,0 Ege Tuft 950 WT Loop Tufted 2500 8,0 950 4,0 Epoca Chess WT Loop Tufted 2750 6,0 1100 3,0 Epoca Classic WT Loop Tufted 2350 6,5 590 4,0 Epoca Classic 1/10 WT Loop Tufted 2500 5,5 725 3,0 Epoca Frame WT Loop Tufted 2500 5,5 800 3,0 Epoca Ribs WT Loop Tufted 2100 5,0 750 3,0 Highline Loop e16 WT Loop Tufted 2100 6,5 850 3,0 Highline Loop WT Loop Tufted 2200 7,0 680 4,0 Una Tempo WT Loop Tufted 2200 5,5 500 3,0 Epoca Compact WT Loop similar Flat Woven 2600 4,0 700 -- Epoca Globe WT Loop similar Flat Woven 2350 4,0 700 -- Epoca Knit WT Loop similar Flat Woven 2100 4,0 560 -- Epoca Plait WT Loop similar Flat Woven 2400 4,0 700 -- Epoca Pro WT Loop similar Flat Woven 2450 4,0 700 -- Epoca Profile WT Loop similar Flat Woven 2350 3,5 625 -- Epoca Rasp WT Loop similar Flat Woven 2100 4,5 700 -- Epoca Stucture WT Loop similar Flat Woven 2400 4,5 700 -- Rawline WT Loop similar Flat Woven 1800 3,4 345 -- Una Casa WT Loop similar Flat Woven 2200 3,5 400 -- Una Micro WT Loop similar Flat Woven 2400 3,0 550 --

VN710 140527.2 5 / 8 4 Test reports and test results for the proof of the classification For building product groups preliminary trials with the heaviest/thickest and lightest/thinnest quality have to be carried out (for the most unfavourable case a complete test has to be carried out) respectively the test results of these "border-qualities" are used for the judgement. The classification is done according to the worst case ("Highline 750 WT, Epoca Chess WT, Una Micro WT ). 4.1 Test report Laboratory DBI Article Highline 750 WT Test report number PF13187 Date of issue 2009-11-09 Applicant Egetaepper A/S Test methods EN ISO 9239-1 and EN ISO 11925-2 Laboratory DBI Article Epoca Chess WT Test report number PF12442w Date of issue 2006-11-09 Applicant Egetaepper A/S Test methods EN ISO 11925-2 and EN ISO 9239-1 Laboratory DBI Article Una Micro WT Test report number PFA10625b Date of issue 2014-11-11 Applicant Egetaepper A/S Test methods EN ISO 11925-2 and EN ISO 9239-1

VN710 140527.2 6 / 8 4.2 Test results Highline 750 WT Ignitability, EN ISO 11925-2 Test results (Mean Value) Number of tests Flame spread 150 mm yes 6 Burning behaviour, EN ISO 9239-1 Critical radiant flux 6,0 kw/m² 3 Integral of smoke obscuration 44 %.min 3 Epoca Chess WT Ignitability, EN ISO 11925-2 Flame spread 150 mm yes 6 Burning behaviour, EN ISO 9239-1 Critical radiant flux 5,3 kw/m² 3 Integral of smoke obscuration 385 %.min 3 Una Micro WT Ignitability, EN ISO 11925-2 Flame spread 150 mm yes 6 Burning behaviour, EN ISO 9239-1 Critical radiant flux 6,0 kw/m² 3 Integral of smoke obscuration 140 %.min 3

VN710 140527.2 7 / 8 5 Classification and field of application 5.1 Reference for classification This classification has been carried out in accordance with EN 13501-1. 5.2 Classification Due to the results of the tests carried out, the building product group PA-WT (C fl s1) can be classified as following. Burning behaviour C fl Smoke emission s1 Classification C fl-s1 5.3 Field of application The classification is valid for the building product group described in point 3 under the following end use conditions. Application Subfloors Installation Horizontal laid floor covering in form of rolls Not burnable subfloors of euroclass A1fl or A2fl with a density of at least 1350 kg/m³. glued Adhesive Polyacrylat-copolymer dispersion adhesive ( ege 90RH / Uzin UZ 57 ) Note: According to EN13501-1(a) the stated classification is valid for the tested floor covering together with the tested adhesive, as well as for all other adhesives of the same generic type as the tested adhesive. 6 Limitations 6.1 Notice This classification document does not represent type permission or certifying the product. If a building product should be CE marked according to system 3 of the attestation of conformity systems, the classification stated with this report is suitable as a basis for the declaration of the producer according to the attestation of conformity system 3, together with a CE marking in the context of the directive relating to construction products. If the manufacturer plans a CE marking in connection with conformity system 3, he has to give an explanation, which has to be attached to the relevant documents. This explanation confirms, that there are no the specific materials, production processes or procedures (e.g. no additives of flame retarding materials, delimitation of organic components or additions of fillers), which are improving the burning behaviour to reach the obtained fire classification. As a consequence from this, the manufacturer drew the conclusion that the system 3 of the attestation of conformity systems is appropriate. The testing laboratory therefore has played no role in the sampling procedure, although the testing laboratory keeps appropriate references from the manufacturer ready, in order to pursue the examined samples.

VN710 140527.2 8 / 8 7 Remarks Validity There are no regulations concerning duration of validity in the individual test standards. As the results of the examinations refer only to the submitted and examined samples, the report is valid for these for an unlimited period. A period of validity specified as part of an expert evaluation is in the discretion of the consultant or the OETI. The applicability of results and expert evaluations for materials not tested is in the responsibility of the applicant. Whereby an apportionment of results as well as any specified period of validity can only be done for identically constructed products and only as long as the product produced unchanged. Possible national or international restrictions concerning the terms of usability of test and classification reports have to be considered; this is not the responsibility of the test laboratory. Sample Material Results of performed tests only refer to the sample material provided. Without explicit written other agreement testing is destructive and the sample material is transferred to the property of ÖTI, which is entitled to freely decide on storage and disposal. Issuance The valid first issue is done in paper and has single-handed signatures. For reference purposes and filing an unsigned electronic duplicate can be delivered in pdf format. Duplicates and translations will be marked accordingly on the cover sheet. Quality management, Accreditation and Notification All tests and services are performed under a quality management system according to EN ISO/IEC 17025 respectively EN ISO/IEC 17065. OETI is accredited as Testing Laboratory and Certification Body for products. It also is a Notified Body for several directives with the registration number 0534 (see http://ec.europa.eu/enterprise/newapproach/nando/). Accreditation was provided by Akkreditierung Austria. The scope of accreditation is listed on www.oeti.biz. Due to the system for the mutual recognition of national accreditations (ILAC/IAF), this accreditation is valid worldwide. In this report individual non-accredited test procedures are marked with *. However, the analysis was also carried out for these parameters at the same level of quality as for the accredited parameters. According to the decree on the use of the accreditation mark ( AkkZV ) the accredited Conformity Assessment Body is the only one to use the accreditation mark. Application of the registration number of the Notified Body: As to personal protective equipment (PPE) the requirements of Regulation (EU) 2016/425 have to be kept. With construction products the application is only permitted within the declaration of performance for CE-marking. Copyright and Usage Notes It is pointed out, that any alterations, amendments or falsifications of reports not authorized by the issuer of the report will be prosecuted as civil and criminal offences; this especially to the appropriate requirements of ABGB, UrhG, UWG and criminal law and their respective international equivalents. Reports are protected under international copyright laws. Written consent of the OETI is required for publications (also in excerpt) and reference to tests for public relation purposes. Reports may only be reproduced in full length. End of report